Fuse

Features and Benefits

● Ceramic and Glass Tube

● Fast Acting and Time Lag



Rated Current:100mA~20A

Rated Voltage:125V,250Vac

● Low and High Breaking Capacity


● Physical Dimensions:Ф5x20mm,Ф3.6x10mm
Fuse

Glossary of Terms

Fuse Normal Operating Current

An overcurrent protective device with a fusible link that oper- The normal operating current of a circuit is the level of cur-
ates and permanently opens the circuit on an overcurrent rent drawn (in RMS or dc amperes) after it has been ener-
condition. gized and is operating under normal conditions. An operating
current of 80% or less of rated current is recommended for
operation at 25℃ to avoid nuisance openings. For example,
Fast Acting Fuse a fuse with a Rated Current of 1A is usually not recommend-
ed in circuits with normal operating currents of more than
A fuse which opens on overload and short circuits very 800mA. Further derating is required at elevated ambient tem-
quickly. This type of fuse is not designed to withstand tempo- peratures.
rary overload currents associated with some electrical load.
UL listed or recognized fast acting fuses would typically open
within 5seconds when subjected to 200% to 250% of its rat-
ed current. IEC has two categories of fast acting fuses:
Ampere squared seconds I2t
● F=Fast acting, opens on 10X rated current within 0.001 The melting, arcing, or clearing integral of a fuse, termed I2t,
seconds to 0.01 seconds is the thermal energy required to melt, arc, or clear a specific
● FF=Very fast acting, opens on 10X rated current within current. It can be expressed as melting I2t, arcing I2t or the
less than 0.001 seconds. sum of them, clearing I2t.

Time Lag Fuse Overload


A fuse with a built-in delay that allows temporary and harm- Can be classified as an overcurrent which exceeds the nor-
less inrush currents to pass without operating, but is so de- mal full load current of a circuit by 2 to 5 times its magnitude
signed to open on sustained overloads and short circuits. UL and stays within the normal current path.
listed or recognized time delay fuses typically open in
2 minutes maximum when subjected to 200% to 250% of
rated current. IEC has two categories of time delay fuses: Overcurrent

● T=Time Lag, opens on 10X rated current within 0.01 A condition which exists in an electrical circuit when the nor-
seconds to 0.1 seconds. mal load current is exceeded. Overcurrent take on two sepa-
rate characteristics-overloads and short circuits.

● TT=Long time Lag, opens on 10X rated current within


0.1 seconds to 1 second. Resistive load

An electrical load which is characterized by not drawing any


Rated Current significant inrush current. When a resistive load is energized,
the current rises instantly to its steady state value, without
The rated current of a fuse identifies its current-carrying ca- first rising to a higher value.
pacity based on a controllable set of test conditions. Each
fuse is marked with its rated current. This rating can be iden-
tified with a numeric, alpha, or color code mark. Color codes
can be found in each product’s data sheet.

Rated Voltage
A maximum open circuit voltage in which a fuse can be
used, yet safely interrupt an overcurrent. Exceeding the
voltage rating of a fuse impairs its ability to clear an over-
load or short circuit safely.

RMS Current

The R.M.S. (root mean square) value of any periodic current


is equal to the value of the direct current ,which flowing
through a resistance, produces the same heating effect in
the resistance as the periodic current does.
Fuse

Short Circuit
An overcurrent that leaves the normal current path and greatly exceeds the normal full load current of the circuit by a factor of
tens, hundreds, or thousands times.

Arcing Time

The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared.

Clearing Time
The total time between the beginning of the overcurrent and the final opening of the circuit at rated voltage by an overcurrent
protective device. Clearing time is the total of the melting time and the arcing time.

Selecting Overcurrent Protection


During normal load conditions, the fuse must carry the normal operating current of the circuit without nuisance openings. How-
ever, when an overcurrent occurs the fuse must interrupt the overcurrent and withstand the voltage across the fuse after inter-
nal arcing.

To properly select a fuse the following items must be considered:


● Rated Voltage (AC or DC Voltage)
● Rated Current
● Normal operating current
● Ambient temperature
● Overload conditions and opening time
● Available short circuit current
● Ampere squared seconds(I2t)
● Pulse and In-rush characteristics
● Characteristics of equipment or components to be protected
● Physical size and available board space
● Standards requirements

Selection Process

Procedure Expound

Start Prepare related design information.

The safety approvals required for fuse shall be upon to the end product. It is deter-
Safety Approval
mined initially IEC standard or UL standard.

● The space limit of circuit in design.


Dimensions ● Mounting mode.

The Rated Voltage of the fuse shall be greater than, or equal to the available cir-
Rated Voltage
cuit voltage.
Fuse

The interrupting rating of the fuse should exceed the Maximum Fault Current of
Interrupting Rating AC
the circuit.

Does there exist “starting current” in a circuit when the end product turns on or
Initial Selection For Fuse Type off? The “starting current” is normal for some circuit and requires the time-lag fuse
or medium time-lag fuse.

The overload current and lasting time in which a fuse must function (It may be
Upper Limit For Rated Current IU
specified on the specific protection needs of circuit by a design engineer.). Refer-
ring to the Time-Current curve, the maximum Rated Current which meet the re-
quirement would be taken as the upper limit for Rated Current IU.

● Steady state current through a fuse (based on the specific circuit).

● The difference of Rated Current for fuse designed to IEC standard and UL
standard, refer to STEADY STATE CURRENT.

● Effect of ambient temperature on current-carrying capacity of fuse, refer to


AMBIENT TEMPERATURE.

Lower Limit For Rated Current IL


● Effect of pulse (including surge currents, starting current, in-rush currents and
transients) on life time of fuse, refer to PULSE.

● “Starting current” and duration should be compared to Time-Current curve of


relevant fuse.

According to the above 5 factors, the minimum Rated Current which meets the
requirement will be as the lower limit of IL.

According to the above factors, choose the most appropriate model and rated
current.
SET Fuse Model & Rated Current
● When IU≥IL , any rating is available from the range of IL to IU.

● When IU<IL, recommend to select another type fuse.

Proving The sample shall be trial-operation in the actual circuit.

End
Fuse
熔断时间的影响
Steady State Current Effect on Opening Time
额定值的影响
Effect on Current Rating
There exist the different conditions between the actual appli- 140

ance and test conditions, such as: 120


1
2
100

Percent of Current Rating

Percent of Opening Ti me
● Fuse-holder;

熔断时间百分比
额定值百分比
80

60
● Connecting cable size; 40

20
● Contacting resistance between fuse clip and fuse, etc.
0
-80 -60 -40 -20 0 20 40 60 80 100 120

环境温度℃
Ambi ent Temperature℃

The above factors should be taken into consideration when


selecting a fuse at a 25℃ ambient temperature. To ensure (2)
the fuse operating continuously and properly, the following Effect on rating and opening time in 5In of fast acting fuse.
conditions shall be required:

● Fuse designed to IEC standard: Rated Current (In)=steady Pulse


state current of circuit/0.9.
Pulse produces thermal cycling and mechanical fatigue
which could affect the life time of fuse. The selected fuse
● Fuse designed to UL standard: Rated Current (In)=steady should have an I2T value much greater than the I2T value of
state current of circuit/0.75. pulse. Refer to Table A showing the relationship between the
life time of fuse(the endurable times of pulse shock) and U
(ratio between pulse I2T value and fuse I2T value). The I2T
Ambient Temperature value of a fuse presented in this catalog may be for your
reference. The I2T value of a pulse can be approximated
from the following formulas for a typical wave shape, refer to
The current carrying capacity tests of a fuse are performed at Table B.
25℃ and will be effected by the changes of the ambient tem-
perature. The higher the ambient temperature is, the shorter
the fuse life time will be, and the lower the current carrying
capacity will be. So the ambient temperature shall be consid- Endurable times of pulse shock U(Ratio)
ered for proper fuse selection.

Refer to the following charts showing its effect on the current 100,000 20%
carrying capacity of all kinds of fuse:
10,000 30%

1,000 40%

Note: Adequate interval(5s-10s) must be required between


熔断时间的影响
Effect on Opening Time pulse events to allow the heat from the previous event
额定值的影响
Effect on Current Rating to dissipate.
160
Table A
140 1

120 2
Percent of Current Rating

Percent of Opening Ti me

100
熔断时间百分比
额定值百分比

80

60

40

20

0
-80 -60 -40 -20 0 20 40 60 80 100 120

环境温度℃
Ambi ent Temperature℃

(1)
Effect on rating and opening time in 5In of traditional time
-lag and medium time-lag fuse.
Fuse

i1 i1 i1 i1 i1 or i1
i2

Wave Shape t1 t1 t1 t1 t1 t1 t1
Rectangle wave Trapezoid wave Triangle wave Sine wave Distortion wave Charge or Discharge wave

2
I t Formula
i12t1 (1/3)(i12+i1i2+i22)t1 (1/3)i12t1 (1/2)i12t1 (1/5)i12t1 (1/2)i12t1

Table B

Proving

The selected sample should be tested in the actual circuit to verify the right selection. The testing should include the tests un-
der normal and fault conditions to ensure that the fuse will operate properly in the circuit.
Fuse, SGF520 Series, Fast Acting, Glass Tube Φ5 X 20

Dimensions (mm)
A B C D(Φ) E F G D1(Φ) d(Φ)
≤6.3A:0.65±0.02
5.0 +0.15
-0 10±2 20±0.5 5 +0.05
-0 21±1 38±2 97±2 5.5±0.2
>6.3A:0.80±0.02

Key Features Agency Approvals

● Φ5mm X 20mm physical size ● CCC:1A~6.3A:2011010207516066


● Fast Acting ● CQC:8A~10A:CQC11012065997
● Low-breaking capacity Axial Leads 1A~10A:CQC11012065997
● Glass tube, Nickel-plated brass endcap construction
● VDE:1A~10A:40033351
● Designed to IEC60127-2/Sheet2.GB9364-2/Sheet2
● KC:1A~2A:SU05023-11007; 3.15A~6.3A:SU05023
● Printers
-11008; 8A~10A:SU05023-11009
● PSE:1A~5A:PSE11020385; 6.3A~10A:PSE11020386
Axial Leads 1A~5A:PSE11020387;
6.3A~10A:PSE11020388
● UL/cURus:1A~10A:E345932
Applications
● Air conditioners Time Current Curve
● Energy-saving Lighting ballasts
Reference
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays

Part Number System


S G F 520 –1A–L
Axial Lead
Rated Current
Dimensions
Fast Acting
Glass Tube
时间Time (s)

Company Code

Structure Diagrams

Element

Tube
Cap
Solder Tin

Axial Lead
电流Current (A)
Fuse, SGF520 Series, Fast Acting, Glass Tube Φ5 X 20

Specifications
Agency Approvals Environmental
Status
Model Rated Rated Interrupting Typical Maximum Typical
Current Voltage Rating DC Cold Voltage Melting
(Vac) (amps ) at Re- Drop I²t
Rated Voltage sistance (mV)★ (A²Sec)
(50Hz) (A) (mΩ)※ CCC CQC VDE KC PSE cURus RoHS REACH
SGF520-200mA 200mA 250 35 1700 ○ ○ ○ ○ ○ ○  

SGF520-250mA 250mA 250 35 1400 ○ ○ ○ ○ ○ ○  

SGF520-315mA 315mA 250 35 1300 ○ ○ ○ ○ ○ ○  

SGF520-400mA 400mA 250 35 1200 ○ ○ ○ ○ ○ ○  

SGF520-500mA 500mA 250 35 1000 ○ ○ ○ ○ ○ ○  

SGF520-630mA 630mA 250 35 650 ○ ○ ○ ○ ○ ○  

SGF520-800mA 800mA 250 35 240 ○ ○ ○ ○ ○ ○  

SGF520-1A 1A 250 35 95.00 150 1.50       

SGF520-1.25A 1.25A 250 35 80.00 150 2.59       

SGF520-1.6A 1.6A 250 35 60.00 140 4.25       

SGF520-2A 2A 250 35 50.00 140 6.24       

SGF520-3.15A 3.15A 250 35 32.00 150 8.93       

SGF520-5A 5A 250 50 19.00 120 36.00       

SGF520-6.3A 6.3A 250 63 15.00 130 46.04       

SGF520-8A 8A 250 80 12.00 125 69.12       

SGF520-10A 10A 250 100 9.00 125 144.00       

SGF520-16A 16A 250 160 120 715.35 ○ ○ ○ ○ ○  

SGF520-20A 20A 250 200 120 945.78 ○ ○ ○ ○ ○  

○-On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).

Pre-arcing Time/Current Characteristic

2.1IN 2.75IN 4IN 10IN


Rated current
Maximum Minimum Maximum Minimum Maximum Maximum

32mA~100mA 30min 10ms 500ms 3ms 100ms 20ms

Above100mA ~6.3A 30min 50ms 2s 10ms 300ms 20ms

Above 6.3A~10A 30min 50ms 2s 10ms 400ms 40ms

Above 10A~20A 30min 100ms 6s 20ms 600ms 60ms

Packaging Information

Packaging Code Description

Endcaps 10000pcs per carton.

Axial Leads 4000pcs per carton.

Endcaps Axial Leads


Fuse, SGT520 Series, Time Lag, Glass Tube Φ5 X 20

Dimensions (mm)
A B C D(Φ) E F G D1(Φ) d(Φ)
≤6.3A:0.65±0.02
5.0 +0.15
-0 10±2 20±0.5 5 +0.05
-0 21±1 38±2 97±2 5.5±0.2
>6.3A:0.80±0.02

Key Features Agency Approvals

● Φ5mm X 20mm physical size ● CCC:1A~6.3A :2011010207516067


● CQC:8A~10A:CQC11012065996
● Time Lag
Axial Leads 1A~10A:CQC11012065996
● Low-breaking capacity ● VDE:1A~10A :40033355
● KC:1A~2A:SU05023-11006; 3.15A~6.3A:SU05023
● Glass tube, Nickel-plated brass endcap construction -11004; 8A~10A:SU05023-11005
Axial Leads 1A~2A:SU05023-11006; 3.15A~6.3A:SU
● Designed to IEC60127-2/Sheet3.GB9364-2/Sheet3 05023-11004; 8A~10A:SU05023-11005
● PSE:1A~5A :PSE11020389; 6.3A~10A:PSE11020390
Axial Leads 1A~5A :PSE11020391; 6.3A~10A:PSE11
Applications 020392
● UL/cURus:1A~10A :E345932
● Printers
● Air conditioners
● Energy-saving Lighting ballasts Time Current Curve
● Power supplies Reference
● Power adapters
● Battery chargers
● TVs/Displays

Part Number System


S G T 520–1A–L

Axial Lead
Rated Current
Dimensions
Time Lag
Glass Tube
公司代码 Company Code
Time (s)

Structure Diagrams

Element

Tube
Cap
Solder Tin

Axial Lead
Current (A)
Fuse, SGT520 Series, Time Lag, Glass Tube Φ5 X 20

Specifications
Environmental
Model Rated Rated Interrupting Typical Maximum Typical Agency Approvals Status
Current Voltage Rating DC Cold Voltage Melting
(Vac) (amps ) at Re- Drop I²t
Rated Volt- sistance (mV)★ (A²Sec)
age(50Hz) (mΩ)※
(A) CCC CQC VDE KC PSE cURus RoHS REACH
SGT520-100mA 100mA 250 35 2500 O O O O O  
SGT520-125mA 125mA 250 35 2000 O O O O O  
SGT520-160mA 160mA 250 35 1900 O O O O O  
SGT520-200mA 200mA 250 35 1500 O O O O O  
SGT520-250mA 250mA 250 35 1300 O O O O O  
SGT520-315mA 315mA 250 35 1100 O O O O O  
SGT520-400mA 400mA 250 35 1000 O O O O O  
SGT520-500mA 500mA 250 35 900 O O O O O  
SGT520-630mA 630mA 250 35 300 O O O O O  
SGT520-800mA 800mA 250 35 250 O O O O O  
SGT520-1A 1A 250 35 85.00 120 5.70       
SGT520-1.25A 1.25A 250 35 56.00 120 11.20       
SGT520-1.6A 1.6A 250 35 46.00 120 20.99       
SGT520-2A 2A 250 35 38.00 120 30.80       
SGT520-3.15A 3.15A 250 35 21.00 100 103.19       
SGT520-5A 5A 250 50 12.00 100 117.50       
SGT520-6.3A 6.3A 250 63 10.00 100 230.20       
SGT520-8A 8A 250 80 8.00 100 355.84       
SGT520-10A 10A 250 100 5.50 100 570.00       
SGT520-15A 15A 250 150 100 1100.2 O O O O O  
SGT520-20A 20A 250 200 100 2735.5 O O O O O  

○-On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★-Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).

Pre-arcing Time/Current Characteristic

2.1IN 2.75IN 4IN 10IN


Rated current
Maximum Minimum Maximum Minimum Maximum Minimum Maximum

32mA~100mA 2min 200ms 10s 40ms 3s 10ms 300ms

Above100mA ~10A 2min 600ms 10s 150ms 3s 20ms 300ms

Above 10A~20A 2min 600ms 10s 150ms 3s 20ms 300ms

Packaging Information

Packaging Code Description

10000pcs per carton.


Endcaps

Axial Leads 4000pcs per carton.

Endcaps Axial Leads


Fuse, SCF520 Series, Fast Acting, Ceramic Tube Φ5 X 20

Dimensions (mm)
A B C D(Φ) E F G D1(Φ) d(Φ)

≤6.3A:0.65±0.02
5.0+0.15 10±2 20±0.5 5 +0.05 21±1 38±2 97±2 5.5±0.2 >6.3A~10A:0.80±0.02
-0 -0
>10A:1.20±0.02

Key Features Agency Approvals

● Φ5mm X 20mm physical size


● CCC:TBA
● Fast Acting ● CQC:TBA
● VDE:TBA
● High-breaking capacity ● KC:TBA
● PSE:TBA
● Ceramic tube, Nickel-plated brass endcap construction ● cURus:TBA

● Designed to IEC60127-2/Sheet1.GB9364-2/Sheet1
Time Current Curve

Applications On-going
● Printers
● Air conditioners
● Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays

Part Number System

S C F 520–1A–L
Axial Lead
Rated Current
Dimensions
Fast Acting
Ceramic Tube
公司代码 Company Code
Structure Diagrams

Element
Filler
Tube
Cap
Solder Tin
Axial Lead
Fuse, SCF520 Series, Fast Acting, Ceramic Tube Φ5 X 20

Specifications
Environmental
Model Rated Rated Interrupting Typical Maxi- Typical Agency Approvals Status
Current Voltage Rating DC Cold mum Melting
(Vac) (amps ) at Re- Voltage I²t
Rated Volt- sistance Drop (A²Sec)
age(50Hz) (mΩ)※ (mV)★
(A) CCC CQC VDE KC PSE cURus RoHS REACH
SCF520-200mA 200mA 250 1500 3500 O O O O O  
SCF520-250mA 250mA 250 1500 2800 O O O O O  
SCF520-315mA 315mA 250 1500 2500 O O O O O  
SCF520-400mA 400mA 250 1500 2000 O O O O O  
SCF520-500mA 500mA 250 1500 1800 O O O O O  
SCF520-630mA 630mA 250 1500 1500 O O O O O  
SCF520-800mA 800mA 250 1500 1200 O O O O O  
SCF520-1A 1A 250 1500 1000 O O O O O  
SCF520-1.25A 1.25A 250 1500 800 O O O O O  
SCF520-1.6A 1.6A 250 1500 600 O O O O O  
SCF520-2A 2A 250 1500 500 O O O O O  
SCF520-2.5A 2.5A 250 1500 400 O O O O O  
SCF520-3.15A 3.15A 250 1500 350 O O O O O  
SCF520-4A 4A 250 1500 300 O O O O O  
SCF520-5A 5A 250 1500 250 O O O O O  
SCF520-6.3A 6.3A 250 1500 200 O O O O O  
SCF520-8A 8A 250 1500 200 O O O O O  
SCF520-10A 10A 250 1500 200 O O O O O  
SCF520-15A 15A 250 600 150 O O O O O  
SCF520-20A 20A 250 500 150 O O O O O  
○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).

Pre-arcing Time/Current Characteristic

2.1IN 2.75IN 4IN 10IN


Rated current
Maximum Minimum Maximum Minimum Maximum Maximum

200mA~4A 30min 10ms 2s 3ms 300ms 20ms

Above 4A ~6.3A 30min 10ms 3s 3ms 300ms 20ms

Above 6.3A~10A 30min 40ms 20s 10ms 1s 30ms

Above 10A~20A 30min 40ms 20s 10ms 1s 40ms

Packaging Information

Packaging Code Description

Endcaps 10000pcs per carton.

Axial Leads 4000pcs per carton.

Endcaps Axial Leads


Fuse, SCT520 Series, Time Lag, Ceramic Tube Φ5 X 20

Dimensions (mm)
A B C D(Φ) E F G D1(Φ) d(Φ)

≤6.3A:0.65±0.02
5.0+0.15 10±2 20±0.5 5 +0.05 21±1 38±2 97±2 5.5±0.2 >6.3A~10A:0.80±0.02
-0 -0
>10A:1.20±0.02

Key Features Agency Approvals

● Φ5mm X 20mm physical size


● CCC:TBA
● Time Lag ● CQC:TBA
● VDE:TBA
● High-breaking capacity ● KC:TBA
● PSE:TBA
● Ceramic tube, Nickel-plated brass endcap construction ● UL/cURus:TBA

● Designed to IEC60127-2/Sheet5.GB9364-2/Sheet5

Time Current Curve


Applications
Reference

● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays
Part Number System
S C T 520–1A–L
Axial Lead
Rated Current
Dimensions
Time Lag
Time (s)

Ceramic Tube
Company Code

Structure Diagrams

Element
Filler
Tube
Cap
Solder Tin
Axial Lead Current (A)
Fuse, SCT520 Series, Time Lag, Ceramic Tube Φ5 X 20

Specifications

Environmental
Interrupting Typical Maximum Typical Agency Approvals
Status
Rated Rating DC Cold
Voltage Melting
Model Rated Voltage (amps ) at Re-
Drop I²t
Current (Vac) Rated Volt- sistance
(mV)★ (A²Sec)
age(50Hz) (mΩ)※
(A) CCC CQC VDE KC PSE cURus RoHS REACH
SCT520-200mA 200mA 250 1500 2100 O O O O O  
SCT520-250mA 250mA 250 1500 1500 O O O O O  
SCT520-315mA 315mA 250 1500 1100 O O O O O  
SCT520-400mA 400mA 250 1500 1000 O O O O O  
SCT520-500mA 500mA 250 1500 850 O O O O O  
SCT520-630mA 630mA 250 1500 650 O O O O O  
SCT520-800mA 800mA 250 1500 500 O O O O O  
SCT520-1A 1A 250 1500 350 O O O O O  
SCT520-1.25A 1.25A 250 1500 300 O O O O O  
SCT520-1.6A 1.6A 250 1500 200 O O O O O  
SCT520-2A 2A 250 1500 190 O O O O O  
SCT520-2.5A 2.5A 250 1500 180 O O O O O  
SCT520-3.15A 3.15A 250 1500 140 O O O O O  
SCT520-4A 4A 250 1500 100 O O O O O  
SCT520-5A 5A 250 1500 100 O O O O O  
SCT520-6.3A 6.3A 250 1500 100 O O O O O  
SCT520-8A 8A 250 1500 100 O O O O O  
SCT520-10A 10A 250 1500 100 O O O O O  
SCT520-15A 15A 250 600 90 O O O O O  
SCT520-20A 20A 250 500 90 O O O O O  

○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).

Pre-arcing Time/Current Characteristic

2.1IN 2.75IN 4IN 10IN

Rated Current
Maximum Minimum Maximum Minimum Maximum Minimum Maximum

200mA~800mA 30min 250ms 80s 50ms 5s 5ms 150ms

Above 800mA ~3.15A 30min 750ms 80s 95ms 5s 10ms 150ms

Above 3.15A~10A 30min 750ms 80s 150ms 5s 10ms 150ms

Above 10A~20A 30min 750ms 80s 150ms 5s 10ms 150ms

Packaging Information

Packaging Code Description

10000pcs per carton.


Endcaps

Axial Leads 4000pcs per carton.

Endcaps Axial Leads


Fuse, SGF3610 Series, Fast Acting, Glass Tube Φ3.6 X 10

Dimensions (mm)
A B(Φ) C D(Φ) E G F(Φ)
≤6.3A:0.60±0.02
10±1 3.6±0.1 11±1 4±0.15 30±1 71±2
>6.3:0.80±0.02

Key Features Agency Approvals

● Φ3.6mm X 10mm physical size ● CCC:TBA


● CQC:TBA
● Fast Acting ● VDE:TBA
● KC:TBA
● Low-breaking capacity ● PSE:TBA
● UL/cURus:TBA
● Glass tube, Nickel-plated brass end cap construction

● Designed to IEC60127-3/Sheet3.GB9364-3/Sheet3
Current Curve

Applications On-going
● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays

Part Number System

S G F 3610–1A–L
Axial Lead
Rated Current
Dimensions
Fast Acting
Glass Tube
公司代码Company Code

Structure Diagrams

Element
Tube

Cap
Solder Tin

Axial Lead
Fuse, SGF3610 Series, Fast Acting, Glass Tube Φ3.6 X 10

Specifications

Model Rated Rated Interrupting Typical Maximum Typical Agency Approvals Environmental
Current Voltage Rating DC Cold Voltage Melting I²t Status
(Vac) (amps ) at Re- Drop (A²Sec)
Rated Volt- sistance (mV)★
age(50Hz) (mΩ)※
(A)
CCC CQC VDE KC PSE cURus RoHS REACH

SGF3610-200mA 200mA 250 35 480 O O O O O  

SGF3610-250mA 250mA 250 35 440 O O O O O  

SGF3610-315mA 315mA 250 35 400 O O O O O  

SGF3610-400mA 400mA 250 35 370 O O O O O  

SGF3610-500mA 500mA 250 35 350 O O O O O  

SGF3610-630mA 630mA 250 35 320 O O O O O  

SGF3610-800mA 800mA 250 35 300 O O O O O  

SGF3610-1A 1A 250 35 280 O O O O O  

SGF3610-1.25A 1.25A 250 35 280 O O O O O  

SGF3610-1.6A 1.6A 250 35 250 O O O O O  

SGF3610-2A 2A 250 35 240 O O O O O  

SGF3610-2.5A 2.5A 250 35 200 O O O O O  

SGF3610-3.15A 3.15A 250 35 180 O O O O O  

SGF3610-4A 4A 250 40 160 O O O O O  

SGF3610-5A 5A 250 50 150 O O O O O  

SGF3610-6.3A 6.3A 250 63 150 O O O O O  

○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).

Pre-arcing Time/Current Characteristic

2.1IN 2.75IN 4IN 10IN


Rated Current
Maximum Minimum Maximum Minimum Maximum Maximum

200mA~6.3A 30min 10ms 3s 3ms 300ms 20ms

Packaging Information

Packaging Code Description

Endcaps TBA

Axial Leads TBA


Fuse, SGT3610 Series, Time Lag, Glass Tube Φ3.6 X 10

Dimensions (mm)
A B(Φ) C D(Φ) E G F(Φ)
≤6.3A:0.60±0.02
10±1 3.6±0.1 11±1 4±0.15 30±1 71±2
>6.3:0.80±0.02

Key Features Agency Approvals

● Φ3.6mm X 10mm physical size ● CCC:TBA


● CQC:TBA
● Time Lag ● VDE:TBA
● KC:TBA
● Low-breaking capacity ● PSE:TBA
● UL/cURus:TBA
● Glass tube, Nickel-plated brass endcap construction

● Designed to IEC60127-3/Sheet4.GB9364-3/Sheet4
Time Current Curve

On-going
Applications

● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays

Part Number System

S G T 3610–1A–L
Axial Lead
Rated Current
Dimensions
Time Lag
Glass Tube
公司代码 Company Code

Structure Diagrams

Element
Tube

Cap
Solder Tin

Axial Lead
Fuse, SGT3610 Series, Time Lag, Glass Tube Φ3.6 X 10

Specifications

Model Rated Rated Interrupting Typical Maxi- Typical Agency Approvals Environmental
Current Voltage Rating DC Cold mum Melting I²t Status
(Vac) (amps ) at Re- Voltage (A²Sec)
Rated Volt- sistance Drop
age(50Hz) (mΩ)※ (mV)★
(A)
CCC CQC VDE KC PSE cURus RoHS REACH

SGT3610-200mA 200mA 250 35 260 O O O O O  

SGT3610-250mA 250mA 250 35 240 O O O O O  

SGT3610-315mA 315mA 250 35 220 O O O O O  

SGT3610-400mA 400mA 250 35 200 O O O O O  

SGT3610-500mA 500mA 250 35 190 O O O O O  

SGT3610-630mA 630mA 250 35 180 O O O O O  

SGT3610-800mA 800mA 250 35 160 O O O O O  

SGT3610-1A 1A 250 35 140 O O O O O  

SGT3610-1.25A 1.25A 250 35 130 O O O O O  

SGT3610-1.6A 1.6A 250 35 120 O O O O O  

SGT3610-2A 2A 250 35 100 O O O O O  

SGT3610-2.5A 2.5A 250 35 100 O O O O O  

SGT3610-3.15A 3.15A 250 35 100 O O O O O  

SGT3610-4A 4A 250 40 100 O O O O O  

SGT3610-5A 5A 250 50 100 O O O O O  

SGT3610-6.3A 6.3A 250 63 100 O O O O O  

○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).

Pre-arcing Time/Current Characteristic

2.1IN 2.75IN 4IN 10IN


Rated Current
Maximum Minimum Maximum Minimum Maximum Minimum Maximum

200mA~6.3A 2min 400ms 10s 150ms 3s 20ms 150ms

Packaging Information

Packaging Code Description

Endcaps TBA

Axial Leads TBA


Fuse, SCF3610 Series, Fast Acting, Ceramic Tube Φ3.6 X 10

Dimensions (mm)
A B(Φ) C D(Φ) E G F(Φ)
≤6.3A:0.60±0.02
10±1 3.6±0.1 11±1 4±0.15 30±1 71±2
>6.3:0.80±0.02

Key Features Agency Approvals

● Φ3.6mm X 10mm physical size ● CCC:TBA


● CQC:TBA
● Fast Acting ● VDE:TBA
● KC:TBA
● Low-breaking capacity ● PSE:TBA
● UL/cURus:TBA
● Ceramic tube, Nickel-plated brass endcap construction

● Designed to IEC60127-3/Sheet3.GB9364-3/Sheet3
Time Current Curve

On-going
Applications

● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays

Part Number System

S C F 3610–1A–L
Axial Lead
Rated Current
Dimensions
Fast Acting
Glass Tube
公司代码Company Code

Structure Diagrams

Element
Tube

Cap
Solder Tin

Axial Lead
Fuse, SCF3610 Series, Fast Acting, Ceramic Tube Φ3.6 X 10

Specifications

Model Rated Rated Interrupting Typical Maximum Typical Agency Approvals Environmental
Current Voltage Rating DC Cold Voltage Melting I²t Status
(Vac) (amps ) at Re- Drop (A²Sec)
Rated Volt- sistance (mV)★
age(50Hz) (mΩ)※
(A)

CCC CQC VDE KC PSE cURus RoHS REACH

SCF3610-200mA 200mA 250 35 480 O O O O O  

SCF3610-250mA 250mA 250 35 440 O O O O O  

SCF3610-315mA 315mA 250 35 400 O O O O O  

SCF3610-400mA 400mA 250 35 370 O O O O O  

SCF3610-500mA 500mA 250 35 350 O O O O O  

SCF3610-630mA 630mA 250 35 320 O O O O O  

SCF3610-800mA 800mA 250 35 300 O O O O O  

SCF3610-1A 1A 250 35 280 O O O O O  

SCF3610-1.25A 1.25A 250 35 280 O O O O O  

SCF3610-1.6A 1.6A 250 35 250 O O O O O  

SCF3610-2A 2A 250 35 240 O O O O O  

SCF3610-2.5A 2.5A 250 35 200 O O O O O  

SCF3610-3.15A 3.15A 250 35 180 O O O O O  

SCF3610-4A 4A 250 40 160 O O O O O  

SCF3610-5A 5A 250 50 150 O O O O O  

SCF3610-6.3A 6.3A 250 63 150 O O O O O  

○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).

Pre-arcing Time/Current Characteristic

2.1IN 2.75IN 4IN 10IN


Rated Current
Maximum Minimum Maximum Minimum Maximum Maximum

200mA~6.3A 30min 10ms 3s 3ms 300ms 20ms

Packaging Information

Packaging Code Description

Endcaps TBA

Axial Leads TBA


Fuse, SCT3610 Series, Time Lag, Ceramic Tube Φ3.6 X 10

Dimensions (mm)
A B(Φ) C D(Φ) E G F(Φ)
≤6.3A:0.60±0.02
10±1 3.6±0.1 11±1 4±0.15 30±1 71±2
>6.3:0.80±0.02

Key Features Agency Approvals

● Φ3.6mm X 10mm physical size ● CCC:TBA


● CQC:TBA
● Time Lag ● VDE:TBA
● KC:TBA
● Low-breaking capacity ● PSE:TBA
● UL/cURus:TBA
● Ceramic tube, Nickel-plated brass endcap construction

● Designed to IEC60127-3/Sheet4.GB9364-3/Sheet4
Time Current Curve

On-going
Applications

● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays

Part Number System

S C T 3610–1A–L
Axial Lead
Rated Current
Dimensions
Time Lag
Ceramic Tube
公司代码 Company Code

Structure Diagrams

Element
Tube

Cap
Solder Tin

Axial Lead
Fuse, SCT3610 Series, Time Lag, Ceramic Tube Φ3.6 X 10

Specifications

Model Rated Rated Interrupting Typical Maximum Typical Agency Approvals Environmental
Current Voltage Rating DC Cold Voltage Melting I²t Status
(Vac) (amps ) at Re- Drop (A²Sec)
Rated Volt- sistance (mV)★
age(50Hz) (mΩ)※
(A)
CCC CQC VDE KC PSE cURus RoHS REACH

SCT3610-200mA 200mA 250 35 260 O O O O O  

SCT3610-250mA 250mA 250 35 240 O O O O O  

SCT3610-315mA 315mA 250 35 220 O O O O O  

SCT3610-400mA 400mA 250 35 200 O O O O O  

SCT3610-500mA 500mA 250 35 190 O O O O O  

SCT3610-630mA 630mA 250 35 180 O O O O O  

SCT3610-800mA 800mA 250 35 160 O O O O O  

SCT3610-1A 1A 250 35 140 O O O O O  

SCT3610-1.25A 1.25A 250 35 130 O O O O O  

SCT3610-1.6A 1.6A 250 35 120 O O O O O  

SCT3610-2A 2A 250 35 100 O O O O O  

SCT3610-2.5A 2.5A 250 35 100 O O O O O  

SCT3610-3.15A 3.15A 250 35 100 O O O O O  

SCT3610-4A 4A 250 40 100 O O O O O  

SCT3610-5A 5A 250 50 100 O O O O O  

SCT3610-6.3A 6.3A 250 63 100 O O O O O  

○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).

Pre-arcing Time/Current Characteristic

2.1IN 2.75IN 4IN 10IN


Rated Current
Maximum Minimum Maximum Minimum Maximum Minimum Maximum

200mA~6.3A 2min 400ms 10s 150ms 3s 20ms 150ms

Packaging Information

Packaging Code Description

Endcaps TBA

Axial Leads TBA

You might also like