Professional Documents
Culture Documents
Ceramic and Glass Tube Fast Acting and Time Lag Rated Current:100mA~20A Rated Voltage:125V,250Vac Low and High Breaking Capacity Physical Dimensions:Ф5x20mm,Ф3.6x10mm
Ceramic and Glass Tube Fast Acting and Time Lag Rated Current:100mA~20A Rated Voltage:125V,250Vac Low and High Breaking Capacity Physical Dimensions:Ф5x20mm,Ф3.6x10mm
Glossary of Terms
An overcurrent protective device with a fusible link that oper- The normal operating current of a circuit is the level of cur-
ates and permanently opens the circuit on an overcurrent rent drawn (in RMS or dc amperes) after it has been ener-
condition. gized and is operating under normal conditions. An operating
current of 80% or less of rated current is recommended for
operation at 25℃ to avoid nuisance openings. For example,
Fast Acting Fuse a fuse with a Rated Current of 1A is usually not recommend-
ed in circuits with normal operating currents of more than
A fuse which opens on overload and short circuits very 800mA. Further derating is required at elevated ambient tem-
quickly. This type of fuse is not designed to withstand tempo- peratures.
rary overload currents associated with some electrical load.
UL listed or recognized fast acting fuses would typically open
within 5seconds when subjected to 200% to 250% of its rat-
ed current. IEC has two categories of fast acting fuses:
Ampere squared seconds I2t
● F=Fast acting, opens on 10X rated current within 0.001 The melting, arcing, or clearing integral of a fuse, termed I2t,
seconds to 0.01 seconds is the thermal energy required to melt, arc, or clear a specific
● FF=Very fast acting, opens on 10X rated current within current. It can be expressed as melting I2t, arcing I2t or the
less than 0.001 seconds. sum of them, clearing I2t.
● T=Time Lag, opens on 10X rated current within 0.01 A condition which exists in an electrical circuit when the nor-
seconds to 0.1 seconds. mal load current is exceeded. Overcurrent take on two sepa-
rate characteristics-overloads and short circuits.
Rated Voltage
A maximum open circuit voltage in which a fuse can be
used, yet safely interrupt an overcurrent. Exceeding the
voltage rating of a fuse impairs its ability to clear an over-
load or short circuit safely.
RMS Current
Short Circuit
An overcurrent that leaves the normal current path and greatly exceeds the normal full load current of the circuit by a factor of
tens, hundreds, or thousands times.
Arcing Time
The amount of time from the instant the fuse link has melted until the overcurrent is interrupted, or cleared.
Clearing Time
The total time between the beginning of the overcurrent and the final opening of the circuit at rated voltage by an overcurrent
protective device. Clearing time is the total of the melting time and the arcing time.
Selection Process
Procedure Expound
The safety approvals required for fuse shall be upon to the end product. It is deter-
Safety Approval
mined initially IEC standard or UL standard.
The Rated Voltage of the fuse shall be greater than, or equal to the available cir-
Rated Voltage
cuit voltage.
Fuse
The interrupting rating of the fuse should exceed the Maximum Fault Current of
Interrupting Rating AC
the circuit.
Does there exist “starting current” in a circuit when the end product turns on or
Initial Selection For Fuse Type off? The “starting current” is normal for some circuit and requires the time-lag fuse
or medium time-lag fuse.
The overload current and lasting time in which a fuse must function (It may be
Upper Limit For Rated Current IU
specified on the specific protection needs of circuit by a design engineer.). Refer-
ring to the Time-Current curve, the maximum Rated Current which meet the re-
quirement would be taken as the upper limit for Rated Current IU.
● The difference of Rated Current for fuse designed to IEC standard and UL
standard, refer to STEADY STATE CURRENT.
According to the above 5 factors, the minimum Rated Current which meets the
requirement will be as the lower limit of IL.
According to the above factors, choose the most appropriate model and rated
current.
SET Fuse Model & Rated Current
● When IU≥IL , any rating is available from the range of IL to IU.
End
Fuse
熔断时间的影响
Steady State Current Effect on Opening Time
额定值的影响
Effect on Current Rating
There exist the different conditions between the actual appli- 140
Percent of Opening Ti me
● Fuse-holder;
熔断时间百分比
额定值百分比
80
60
● Connecting cable size; 40
20
● Contacting resistance between fuse clip and fuse, etc.
0
-80 -60 -40 -20 0 20 40 60 80 100 120
环境温度℃
Ambi ent Temperature℃
Refer to the following charts showing its effect on the current 100,000 20%
carrying capacity of all kinds of fuse:
10,000 30%
1,000 40%
120 2
Percent of Current Rating
Percent of Opening Ti me
100
熔断时间百分比
额定值百分比
80
60
40
20
0
-80 -60 -40 -20 0 20 40 60 80 100 120
环境温度℃
Ambi ent Temperature℃
(1)
Effect on rating and opening time in 5In of traditional time
-lag and medium time-lag fuse.
Fuse
i1 i1 i1 i1 i1 or i1
i2
Wave Shape t1 t1 t1 t1 t1 t1 t1
Rectangle wave Trapezoid wave Triangle wave Sine wave Distortion wave Charge or Discharge wave
2
I t Formula
i12t1 (1/3)(i12+i1i2+i22)t1 (1/3)i12t1 (1/2)i12t1 (1/5)i12t1 (1/2)i12t1
Table B
Proving
The selected sample should be tested in the actual circuit to verify the right selection. The testing should include the tests un-
der normal and fault conditions to ensure that the fuse will operate properly in the circuit.
Fuse, SGF520 Series, Fast Acting, Glass Tube Φ5 X 20
Dimensions (mm)
A B C D(Φ) E F G D1(Φ) d(Φ)
≤6.3A:0.65±0.02
5.0 +0.15
-0 10±2 20±0.5 5 +0.05
-0 21±1 38±2 97±2 5.5±0.2
>6.3A:0.80±0.02
Company Code
Structure Diagrams
Element
Tube
Cap
Solder Tin
Axial Lead
电流Current (A)
Fuse, SGF520 Series, Fast Acting, Glass Tube Φ5 X 20
Specifications
Agency Approvals Environmental
Status
Model Rated Rated Interrupting Typical Maximum Typical
Current Voltage Rating DC Cold Voltage Melting
(Vac) (amps ) at Re- Drop I²t
Rated Voltage sistance (mV)★ (A²Sec)
(50Hz) (A) (mΩ)※ CCC CQC VDE KC PSE cURus RoHS REACH
SGF520-200mA 200mA 250 35 1700 ○ ○ ○ ○ ○ ○
○-On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
Packaging Information
Dimensions (mm)
A B C D(Φ) E F G D1(Φ) d(Φ)
≤6.3A:0.65±0.02
5.0 +0.15
-0 10±2 20±0.5 5 +0.05
-0 21±1 38±2 97±2 5.5±0.2
>6.3A:0.80±0.02
Axial Lead
Rated Current
Dimensions
Time Lag
Glass Tube
公司代码 Company Code
Time (s)
Structure Diagrams
Element
Tube
Cap
Solder Tin
Axial Lead
Current (A)
Fuse, SGT520 Series, Time Lag, Glass Tube Φ5 X 20
Specifications
Environmental
Model Rated Rated Interrupting Typical Maximum Typical Agency Approvals Status
Current Voltage Rating DC Cold Voltage Melting
(Vac) (amps ) at Re- Drop I²t
Rated Volt- sistance (mV)★ (A²Sec)
age(50Hz) (mΩ)※
(A) CCC CQC VDE KC PSE cURus RoHS REACH
SGT520-100mA 100mA 250 35 2500 O O O O O
SGT520-125mA 125mA 250 35 2000 O O O O O
SGT520-160mA 160mA 250 35 1900 O O O O O
SGT520-200mA 200mA 250 35 1500 O O O O O
SGT520-250mA 250mA 250 35 1300 O O O O O
SGT520-315mA 315mA 250 35 1100 O O O O O
SGT520-400mA 400mA 250 35 1000 O O O O O
SGT520-500mA 500mA 250 35 900 O O O O O
SGT520-630mA 630mA 250 35 300 O O O O O
SGT520-800mA 800mA 250 35 250 O O O O O
SGT520-1A 1A 250 35 85.00 120 5.70
SGT520-1.25A 1.25A 250 35 56.00 120 11.20
SGT520-1.6A 1.6A 250 35 46.00 120 20.99
SGT520-2A 2A 250 35 38.00 120 30.80
SGT520-3.15A 3.15A 250 35 21.00 100 103.19
SGT520-5A 5A 250 50 12.00 100 117.50
SGT520-6.3A 6.3A 250 63 10.00 100 230.20
SGT520-8A 8A 250 80 8.00 100 355.84
SGT520-10A 10A 250 100 5.50 100 570.00
SGT520-15A 15A 250 150 100 1100.2 O O O O O
SGT520-20A 20A 250 200 100 2735.5 O O O O O
○-On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★-Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
Packaging Information
Dimensions (mm)
A B C D(Φ) E F G D1(Φ) d(Φ)
≤6.3A:0.65±0.02
5.0+0.15 10±2 20±0.5 5 +0.05 21±1 38±2 97±2 5.5±0.2 >6.3A~10A:0.80±0.02
-0 -0
>10A:1.20±0.02
● Designed to IEC60127-2/Sheet1.GB9364-2/Sheet1
Time Current Curve
Applications On-going
● Printers
● Air conditioners
● Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays
S C F 520–1A–L
Axial Lead
Rated Current
Dimensions
Fast Acting
Ceramic Tube
公司代码 Company Code
Structure Diagrams
Element
Filler
Tube
Cap
Solder Tin
Axial Lead
Fuse, SCF520 Series, Fast Acting, Ceramic Tube Φ5 X 20
Specifications
Environmental
Model Rated Rated Interrupting Typical Maxi- Typical Agency Approvals Status
Current Voltage Rating DC Cold mum Melting
(Vac) (amps ) at Re- Voltage I²t
Rated Volt- sistance Drop (A²Sec)
age(50Hz) (mΩ)※ (mV)★
(A) CCC CQC VDE KC PSE cURus RoHS REACH
SCF520-200mA 200mA 250 1500 3500 O O O O O
SCF520-250mA 250mA 250 1500 2800 O O O O O
SCF520-315mA 315mA 250 1500 2500 O O O O O
SCF520-400mA 400mA 250 1500 2000 O O O O O
SCF520-500mA 500mA 250 1500 1800 O O O O O
SCF520-630mA 630mA 250 1500 1500 O O O O O
SCF520-800mA 800mA 250 1500 1200 O O O O O
SCF520-1A 1A 250 1500 1000 O O O O O
SCF520-1.25A 1.25A 250 1500 800 O O O O O
SCF520-1.6A 1.6A 250 1500 600 O O O O O
SCF520-2A 2A 250 1500 500 O O O O O
SCF520-2.5A 2.5A 250 1500 400 O O O O O
SCF520-3.15A 3.15A 250 1500 350 O O O O O
SCF520-4A 4A 250 1500 300 O O O O O
SCF520-5A 5A 250 1500 250 O O O O O
SCF520-6.3A 6.3A 250 1500 200 O O O O O
SCF520-8A 8A 250 1500 200 O O O O O
SCF520-10A 10A 250 1500 200 O O O O O
SCF520-15A 15A 250 600 150 O O O O O
SCF520-20A 20A 250 500 150 O O O O O
○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
Packaging Information
Dimensions (mm)
A B C D(Φ) E F G D1(Φ) d(Φ)
≤6.3A:0.65±0.02
5.0+0.15 10±2 20±0.5 5 +0.05 21±1 38±2 97±2 5.5±0.2 >6.3A~10A:0.80±0.02
-0 -0
>10A:1.20±0.02
● Designed to IEC60127-2/Sheet5.GB9364-2/Sheet5
● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays
Part Number System
S C T 520–1A–L
Axial Lead
Rated Current
Dimensions
Time Lag
Time (s)
Ceramic Tube
Company Code
Structure Diagrams
Element
Filler
Tube
Cap
Solder Tin
Axial Lead Current (A)
Fuse, SCT520 Series, Time Lag, Ceramic Tube Φ5 X 20
Specifications
Environmental
Interrupting Typical Maximum Typical Agency Approvals
Status
Rated Rating DC Cold
Voltage Melting
Model Rated Voltage (amps ) at Re-
Drop I²t
Current (Vac) Rated Volt- sistance
(mV)★ (A²Sec)
age(50Hz) (mΩ)※
(A) CCC CQC VDE KC PSE cURus RoHS REACH
SCT520-200mA 200mA 250 1500 2100 O O O O O
SCT520-250mA 250mA 250 1500 1500 O O O O O
SCT520-315mA 315mA 250 1500 1100 O O O O O
SCT520-400mA 400mA 250 1500 1000 O O O O O
SCT520-500mA 500mA 250 1500 850 O O O O O
SCT520-630mA 630mA 250 1500 650 O O O O O
SCT520-800mA 800mA 250 1500 500 O O O O O
SCT520-1A 1A 250 1500 350 O O O O O
SCT520-1.25A 1.25A 250 1500 300 O O O O O
SCT520-1.6A 1.6A 250 1500 200 O O O O O
SCT520-2A 2A 250 1500 190 O O O O O
SCT520-2.5A 2.5A 250 1500 180 O O O O O
SCT520-3.15A 3.15A 250 1500 140 O O O O O
SCT520-4A 4A 250 1500 100 O O O O O
SCT520-5A 5A 250 1500 100 O O O O O
SCT520-6.3A 6.3A 250 1500 100 O O O O O
SCT520-8A 8A 250 1500 100 O O O O O
SCT520-10A 10A 250 1500 100 O O O O O
SCT520-15A 15A 250 600 90 O O O O O
SCT520-20A 20A 250 500 90 O O O O O
○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
Rated Current
Maximum Minimum Maximum Minimum Maximum Minimum Maximum
Packaging Information
Dimensions (mm)
A B(Φ) C D(Φ) E G F(Φ)
≤6.3A:0.60±0.02
10±1 3.6±0.1 11±1 4±0.15 30±1 71±2
>6.3:0.80±0.02
● Designed to IEC60127-3/Sheet3.GB9364-3/Sheet3
Current Curve
Applications On-going
● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays
S G F 3610–1A–L
Axial Lead
Rated Current
Dimensions
Fast Acting
Glass Tube
公司代码Company Code
Structure Diagrams
Element
Tube
Cap
Solder Tin
Axial Lead
Fuse, SGF3610 Series, Fast Acting, Glass Tube Φ3.6 X 10
Specifications
Model Rated Rated Interrupting Typical Maximum Typical Agency Approvals Environmental
Current Voltage Rating DC Cold Voltage Melting I²t Status
(Vac) (amps ) at Re- Drop (A²Sec)
Rated Volt- sistance (mV)★
age(50Hz) (mΩ)※
(A)
CCC CQC VDE KC PSE cURus RoHS REACH
○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
Packaging Information
Endcaps TBA
Dimensions (mm)
A B(Φ) C D(Φ) E G F(Φ)
≤6.3A:0.60±0.02
10±1 3.6±0.1 11±1 4±0.15 30±1 71±2
>6.3:0.80±0.02
● Designed to IEC60127-3/Sheet4.GB9364-3/Sheet4
Time Current Curve
On-going
Applications
● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays
S G T 3610–1A–L
Axial Lead
Rated Current
Dimensions
Time Lag
Glass Tube
公司代码 Company Code
Structure Diagrams
Element
Tube
Cap
Solder Tin
Axial Lead
Fuse, SGT3610 Series, Time Lag, Glass Tube Φ3.6 X 10
Specifications
Model Rated Rated Interrupting Typical Maxi- Typical Agency Approvals Environmental
Current Voltage Rating DC Cold mum Melting I²t Status
(Vac) (amps ) at Re- Voltage (A²Sec)
Rated Volt- sistance Drop
age(50Hz) (mΩ)※ (mV)★
(A)
CCC CQC VDE KC PSE cURus RoHS REACH
○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
Packaging Information
Endcaps TBA
Dimensions (mm)
A B(Φ) C D(Φ) E G F(Φ)
≤6.3A:0.60±0.02
10±1 3.6±0.1 11±1 4±0.15 30±1 71±2
>6.3:0.80±0.02
● Designed to IEC60127-3/Sheet3.GB9364-3/Sheet3
Time Current Curve
On-going
Applications
● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays
S C F 3610–1A–L
Axial Lead
Rated Current
Dimensions
Fast Acting
Glass Tube
公司代码Company Code
Structure Diagrams
Element
Tube
Cap
Solder Tin
Axial Lead
Fuse, SCF3610 Series, Fast Acting, Ceramic Tube Φ3.6 X 10
Specifications
Model Rated Rated Interrupting Typical Maximum Typical Agency Approvals Environmental
Current Voltage Rating DC Cold Voltage Melting I²t Status
(Vac) (amps ) at Re- Drop (A²Sec)
Rated Volt- sistance (mV)★
age(50Hz) (mΩ)※
(A)
○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
Packaging Information
Endcaps TBA
Dimensions (mm)
A B(Φ) C D(Φ) E G F(Φ)
≤6.3A:0.60±0.02
10±1 3.6±0.1 11±1 4±0.15 30±1 71±2
>6.3:0.80±0.02
● Designed to IEC60127-3/Sheet4.GB9364-3/Sheet4
Time Current Curve
On-going
Applications
● Printers
● Air conditioners
● Energy-saving Lighting ballasts
● Power supplies
● Power adapters
● Battery chargers
● TVs/Displays
S C T 3610–1A–L
Axial Lead
Rated Current
Dimensions
Time Lag
Ceramic Tube
公司代码 Company Code
Structure Diagrams
Element
Tube
Cap
Solder Tin
Axial Lead
Fuse, SCT3610 Series, Time Lag, Ceramic Tube Φ3.6 X 10
Specifications
Model Rated Rated Interrupting Typical Maximum Typical Agency Approvals Environmental
Current Voltage Rating DC Cold Voltage Melting I²t Status
(Vac) (amps ) at Re- Drop (A²Sec)
Rated Volt- sistance (mV)★
age(50Hz) (mΩ)※
(A)
CCC CQC VDE KC PSE cURus RoHS REACH
○- On-going.
※- DC Cold Resistance (Measured at <10% of rated current).
★- Maximum Voltage Drop (voltage drop was measured at 20°C ambient temperature at rated current).
Packaging Information
Endcaps TBA