TDS - Auramix BCI

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Auramix BCI

constructive solutions

Organic Bipolar concrete penetrating cor-


rosion inhibiting admixture.

Uses: enables to reduce concrete porosity through water reduction


and thereby improves durability of concrete.
Auramix BCI is used as corrosion inhibiting admixture for all
reinforced concrete and not limited to Action Mechanism :

Below ground structure such as Pile, pile cap, mat Auramix BCI absorbs onto the reinforcing steel and forms a
foundation where chloride threshold value is more in the uniform protective film covering both cathodic and anodic active
soil. sites on the steel surface. This protective film prevents access
 Bridges and flyovers of chlorides, moisture and oxygen to the steel and thereby
Structures in coastal areas and submerged conditions significantly slows down the rate of corrosion.
Power plants
Technical support
Steel plants
Fosroc provides technical advisory service for on-site assis-
High rise buildings
tance and guidance on concrete mix design, optimum dosage
Structures in sea water
evaluation trials.
Pre-cast Elements
Physical Properties
Tunnels and underground structures
Appearance : Colourless to pale yellow

Standards compliance pH : 10 to 12*

Auramix BCI has been tested in accordance with various Relative Density : 1.01 to 1.04*
standards such as , ASTM G1, ASTM G3, JIS 1535 (modified) Chloride content : Nil to BS 5075
IS9103 for compressive strength, AASHTO – T259, ASTM C
* The uniformity parameters like specific gravity, pH, chloride
1202 and ASTM G109*.
content etc. will vary for specific customer requirements and
mix design. Please refer our MTC issued for specific product
configuration for measuring our product parameters that will
Advantages be constantly and consistently administered
Auramx BCI is a low dosage admixture having Dosage
 Nitrites free
Auramix BCI is recommended to use at a dosage of 3 to 5kgs/
 Improves durability of the structure m 3. It can be added separately to the concrete mixer along
 Used as a admixture: Dosage is independent of with other admixtures.
anticipated chloride levels
Compatability
Ensures steel protection even in the hardened concrete
Auramix BCI is compatible with PCE and SNF based admix-
Does not get consumed by cement hydration
tures, in addition to all types of cement, OPC, PPC, OPC &
 No adverse effect on slump retention and compressive GGBFS and OPC & Flyash, micro silica.
strength
Auramix BCI is also compatible with air entraining, waterproof-
Independent reports tested to International standards
ing, shrinkage reducing concrete admixtures.
Description.
Estimating
Auramix BCI is an unique bipolar concrete penetrating type cor-
Packaging
rosion inhibiting admixture for steel in the reinforced concrete.
It is a blend of selected amines through research which pref- Auramix BCI is available in 200kg, 240kg barrels and bulk
erentially provide protection to steel in both liquid and vapour supply.
Auramix BCI

phases. The vapours penetrate even through the hardened


concrete towards steel due to strong affinity. Auramix BCI also

page 1 of 2
Auramix BCI
Storage Additional information

Auramix BCI has a shelf life of 12 months if stored above 50C The Fosroc range of associated products includes high
0
and below 50 C in the tightly sealed original container. strength cementitious, epoxy grout, polyester resin based
mortar for rapid pre-setting of steel shims to level or for
Precautions
direct bedding of small base plates; Resin Anchoring
Health and safety instructions systems for same day anchoring of bolts in drilled holes in
concrete or rock. Also available a range of products for use
Auramix BCI should not be swallowed or allowed to come in
in construction; viz., curing compounds, release agents,
contact with skin or eyes. Suitable protective gloves and gog-
flooring systems, repair mortars, sealants and waterproofing
gles should be worn.
materials.
Splash on skin should be cleaned with water. In case of contact
Separate datasheets are available on these products.
with eyes rinse immediately with plenty of water and seek medi-
cal advice. If swallowed seek medical attention immediately do
not induce vomiting. Please refer safety datasheet before use.

Fire

Auramix BCI is water based and non- flammable.

Cleaning and disposal

Spillage of Auramix BCI should be absorbed on to sand, earth


or vermiculite and transferred to suitable container. Remnants
should be hosed down with large quantity of water. The dis-
posal of excess or waste material should be carried out in
accordance with local legislation under the guidance of the
local waste regulatory authority.

Important note :
Fosroc products are guaranteed against defective materials and manufacture and are sold
subject to its standard terms and conditions of sale, copies of which may be obtained on
request. Whilst Fosroc endeavours to ensure that any advice, recommendation specification
or information it may give is accurate and correct, it cannot, because it has no direct or
continuous control over where or how its products are applied, accept any liability either
Fosroc Chemicals directly or indirectly arising from the use of its products whether or not in accordance with
any advice, specification, recommendation or information given by it.
(India) Pvt. Ltd.
Head Office telephone fax e-mail
“Sapthagiri Palace”, No.38,
II & III Floor, 12th Cross, ++91 80-42521900 ++91 80-23551510 enquiryindia@fosroc.com
CBI Road, Ganganagar North,
Bangalore 560 024

Regional Offices

Chennai Mumbai Noida Kolkata


No. 26(old no.33), 1st Floor, MBC Park, 12th floor, Office No.12B, Unit No. 601, Highway Tower-II 304, Jodhpur Park
1st Street Postal Colony, ‘D’ Block, Near G Corp/Hyper City A-13/2, 6th Floor, Sector– 62 Kolkata 700 068
West Mambalam, Kasarwadawali, Ghodbunder Road, Gautam Buddha Nagar, Ph:+91 33-65343188
Chennai 600 033. Thane (West) 400 615 Noida 201 309, Uttar Pradesh Fax: 033-2499-0280
Ph: +91 44 24899949-94 Ph: +91 22 6229 6800 Ph: +91 120 6121900
Fax: 044-24896641 Fax: 022 62296809

www.fosroc.com
page 2 of 2 INDIA/2019/0189/A