DATE RECEIVED:

NOTES: 2 2a
1.) ALL STEEL GRADES TO BE S275 This shopdrawing has been examined by
2.) THE DESIGN ONLY ALLOW 10kn FOR THE IMPACT LOAD AND 1.5kPa LIVE LOAD 1120
3.) YIELD STRENGTH IF REINFORCEMENT BAR TO BE 500MPa Architect Structural Engineer M&E Engineer
ZINC FLASHING
4.) ALL WELDING AT LEAST 3mm FILLET WELD U.O.S. @ BOTH SIDES and is returned. Our examination of the drawings do not
relieve the Contractor of his responsibilities. Work shall
conform to all drawings and Specifications. The Contractor
is responsible for all correctness of dimensions and details
2 Nos. T-16 REBAR in these drawings and for the full coordination of all aspects
3mm STEEL PLATE
WELD TO I-BEAM of the work.
2 2a (MINIMUM EMBEDMENT
100 x 50 x 3mm RHS OR DEPTH 200mm)
1120 BIGGER MEMBER TO BE USED Examined, with Examined, observation Examined and
@ 125mm C/C no objection added, Resubmission resubmission required
not required

Signed : Date:
5th Storey
143080

200

200
B
WH/EK/TW/CB/05
2 Nos. T-16 REBAR
WELD TO I-BEAM
(MINIMUM EMBEDMENT TAG WELD
DEPTH 200mm) BETWEEN
ZINC FLASHING
@ BOTH SIDES 3343 RHS & I-BEAM

4 Nos. 150 x 150 x 31.1kg/m


I-BEAM OR BIGGER
3mm STEEL PLATE MEMBER TO BE USED
3941

4 Nos. 150 x 150 x 31.1kg/m


I-BEAM OR BIGGER

641
MEMBER TO BE USED
SECTION A
A 1 : 25
100 x 50 x 3mm RHS OR
BIGGER MEMBER TO BE USED D
@ 125mm C/C

1283
ZINC FLASHING 2 Nos. T-16 REBAR
@ BOTH SIDES WELD TO I-BEAM
(MINIMUM
EMBEDMENT
DEPTH 200mm) 0 05/05/21 - AY
3mm STEEL PLATE REVISION: DATE: DESCRIPTION:
DRAWN
BY :
A
WH/EK/TW/CB/05 LAND OWNER: HOUSE AND DEVELOPMENT BOARD
100 x 50 x 3mm RHS OR
BIGGER MEMBER TO BE USED

1283

5130
DEVELOPER: STUTTGART AUTO PTE.LTD
@ 125mm C/C
D OWNER'S ADDRESS: EUROKARS CENTRE 12 SUNGEIKADUT
AVENUE SINGAPORE 729648

2 Nos. T-16 5th Storey ARCHITECT:


REBAR WELD 143080
TO I-BEAM
ACLA ARCHITECTS
1283 10 ANSON ROAD #18-17 SINGAPORE 079903
TEL: +65 94234396, FAX: +65 62340158
2

5130 STRUCTURE CONSULTANT:


*NOTE:
TAG WELD TAG WELD
BETWEEN RHS
4 Nos. 150 x 150 x 31.1kg/m
I-BEAM OR BIGGER
BETWEEN EUREKA CONSULTANTS
& I-BEAM RHS & I-BEAM
MEMBER TO BE USED 18 BOON LAY WAY #09-109
641

18@TradeHub21
SINGAPORE 609966
TEL: 63169521 FAX: 63169543

M & E CONSULTANT
600 SECTION B
B 1 : 25
3943
GIMS & ASSOCIATES PTE LTD
5 9 U B I A V E 1 # 0 5 - 2 0 B I Z L I N K CENTRE
SINGAPORE 408938
EMAIL: gims@gims.com.sg

MAIN CONTRACTOR


39 KIM KEAT ROAD, WEE HUR BUILDING,
SINGAPORE 328814
TEL : (65)6258 1002 FAX : (65)6251 0039

PROJECT TITLE:
PROPOSED ERECTION OF A 8-STOREY SINGLE
PLEASE PROVIDE CONNECTIVITY USER FACTORY WITH 3 LEVELS OF BASEMENT
BETWEEN THE 2T16 AS SHOWN AND CAPPARK COMPRISING OF WORKSHOP &
PROVIDE WELDING ON THE FLANGE
BETWEEN REBAR AND I-BEAM ANCILLARY CAR SHOWROOM & ANCILLARY
5TH STOREY CRASH BARRIER (PASSENGER LIFT) OFFICE ON LOTS-00255W/ 00256V/ 00261T/
1 1 : 25
00262A/ 00263K/ 00264N MK-01 AT 11/ 13/ 15
KUNG CHONG ROAD & 12/ 14/ 16 CHANG CHARN
ROAD (BUKIT MERAH PLANNING AREA)
DRAWING TITLE:

5TH STOREY CRASH BARRIER @ PASSENGER LIFT

3D VIEW SCALE:
1 : 25
DRAWN BY:
AY
CHECKED: DATE:
05/05/21
2 DWG NO:
AN
REV:
0
WH/EK/TW/CB/05

You might also like