Professional Documents
Culture Documents
Beam-Column Analysis: LB LP
Beam-Column Analysis: LB LP
REMARKS : Lb = 4000.00 mm
Flange Flange is Compact!! Lp = 4323.90 mm
Web Web is compact!! Lr = 20399.85 mm
Therefore, use
equation :
Lb ≤ Lp
FOR COMPACT SECTION
Proceed to condition 1
CONDITION 2 :
Mn = -32310.627 kN.m
ØMn = -29079.564 kN.m
CONDITION 3 :
Fcr = 3360.09 MPa
Mn = 823.953 kN.m
ØMn = 741.557 kN.m
@Yielding
Mn = Mp = 823.953 kN.m
ØMn = 741.557 kN.m
@Flange Local Buckling Note : Local Buckling Does Not Apply if the flange is
Flange is Compact!! Compact
Mn = 823.953 kN.m
ØMn = 741.557 kN.m
Pu/ØPn = 0.19
Pu/ØPn < 0.2
Use AISC Equation H1-1b
REMARKS:
0.89086762 ≤ 1.00
SAFE!