This homework assignment contains 4 questions regarding specifications of various transducers. Question 1 asks about the significance of nonlinearity, hysteresis, temperature sensitivity, accuracy, sensitivity, repeatability, and linearity specifications provided for 8 different transducers. Question 2 asks about the total error due to nonlinearity and hysteresis for a pressure sensor reading of 1000 kPa. Question 3 asks about the nonlinearity error as a percentage of full scale for a thermocouple measuring between 0-400°C. Question 4 asks if a strain gauge pressure sensor would be suitable for measuring pressures from 100-105 kPa with ±5 kPa accuracy given its specifications.
This homework assignment contains 4 questions regarding specifications of various transducers. Question 1 asks about the significance of nonlinearity, hysteresis, temperature sensitivity, accuracy, sensitivity, repeatability, and linearity specifications provided for 8 different transducers. Question 2 asks about the total error due to nonlinearity and hysteresis for a pressure sensor reading of 1000 kPa. Question 3 asks about the nonlinearity error as a percentage of full scale for a thermocouple measuring between 0-400°C. Question 4 asks if a strain gauge pressure sensor would be suitable for measuring pressures from 100-105 kPa with ±5 kPa accuracy given its specifications.
This homework assignment contains 4 questions regarding specifications of various transducers. Question 1 asks about the significance of nonlinearity, hysteresis, temperature sensitivity, accuracy, sensitivity, repeatability, and linearity specifications provided for 8 different transducers. Question 2 asks about the total error due to nonlinearity and hysteresis for a pressure sensor reading of 1000 kPa. Question 3 asks about the nonlinearity error as a percentage of full scale for a thermocouple measuring between 0-400°C. Question 4 asks if a strain gauge pressure sensor would be suitable for measuring pressures from 100-105 kPa with ±5 kPa accuracy given its specifications.
Q. 1 Explain the significance of the following information given in the specification of
transducers: (a) A piezoelectric accelerometer. Non-linearity: ±0.5% of full range (b) A capacitive linear displacement transducer. Nonlinearity and hysteresis: ±0.01% of full range. (c) A resistance strain gauge force measurement transducer. Temperature sensitivity: ±1% of full range over normal environmental temperatures. (d) A capacitance fluid pressure transducer. Accuracy:±1% of displayed reading. (e) Thermocouple. Sensitivity: 0.039𝑚𝑚𝑚𝑚/℃ when the cold junction at 0℃ (f) Gyroscope for angular velocity measurement. Repeatability: ±0.01% of full range (g)Inductive displacement transducer. Linearity: ±1% of rated load (h)Load cell. Total error due to nonlinearity, hysteresis and non repeatability: ±0.1% Q.2 A pressure sensor consisting of a diaphragm with strain gauges bonded to its surface has the following information it its specification: Ranges: 0 to 1400 𝑘𝑘𝑘𝑘𝑘𝑘, 0 to 35000 𝑘𝑘𝑘𝑘𝑘𝑘 Nonlineartiy error: ±0.15% of full range Hysteresis error: ±0.05% of full range What is the total error due to non-linearity and hysteresis for a reading of 1000 𝑘𝑘𝑘𝑘𝑘𝑘 on the 0 t0 1400 𝑘𝑘𝑘𝑘𝑘𝑘 range? Q.3 A thermocouple is to be used to measure temperatures between 0 and 400℃. What will be the non-linearity error as a percentage of full scale reading at 100℃ if a linear relationship is assumed between e.m.f and temperature? 𝑒𝑒. 𝑚𝑚. 𝑓𝑓 𝑎𝑎𝑎𝑎 100℃ = 5.268𝑚𝑚𝑚𝑚; 𝑒𝑒. 𝑚𝑚. 𝑓𝑓 𝑎𝑎𝑎𝑎 400℃ = 21.846𝑚𝑚𝑚𝑚 Q.4 A strain gauge pressure sensor has the following specification: Ranges: 2 to 70 𝑀𝑀𝑀𝑀𝑀𝑀, 70 𝐾𝐾𝐾𝐾𝐾𝐾 to 1𝑀𝑀𝑀𝑀𝑀𝑀 Excitation: 10 𝑉𝑉 d.c. or a.c. (r.m.s.) Full range output: 40 𝑚𝑚𝑚𝑚 Non-linearity and hysteresis errors: ±0.5% Temperature range: −54 to +120℃ Thermal shift zero: 0.030% full range output/℃ Thermal shift sensitivity: 0.030% full range output/℃ Will it be suitable for measurement of pressure of order of 100 𝑘𝑘𝑘𝑘𝑘𝑘 to an accuracy of ±5 𝑘𝑘𝑘𝑘𝑎𝑎 in an environment where the temperature is reasonably constant at about 20℃?