MCC 


omponents
RL201
21201 Itasca Street Chatsworth THRU

  !"# RL207
$
%    !"#

Features 2 Amp
• Low Cost
• Low Leakage Silicon Rectifier
• Low Forward Voltage Drop
• High Current Capability 50 to 1000 Volts

DO-15
Maximum Ratings
• Operating Temperature: -55°C to +150°C
• Storage Temperature: -55°C to +150°C
• Typical Thermal Resistance (R θJA) 40°C/W

MCC Device Maximum Maximum Maximum D

Catalog Marking Recurrent RMS DC


Number Peak Reverse Voltage Blocking
Voltage Voltage
RL201 --- 50V 35V 50V A
RL202 --- 100V 70V 100V Cathode
Mark
RL203 --- 200V 140V 200V
RL204 --- 400V 280V 400V B

RL205 --- 600V 420V 600V


D
RL206 --- 800V 560V 800V
RL207 --- 1000V 700V 1000V

Electrical Characteristics @ 25°C Unless Otherwise Specified


Average Forward IF(AV) 2A TA = 75°C
Current DIMENSIONS
Peak Forward Surge IFSM 60A 8.3ms, half sine INCHES MM
Current DIM MIN MAX MIN MAX NOTE
A .230 .300 5.80 7.60
Maximum IFM = 2.0A; B .104 .140 2.60 3.60
Instantaneous VF 1.0V TA = 25°C C .026 .034 .70 .90
D 1.000 --- 25.40 ---
Forward Voltage
Maximum DC
Reverse Current At IR 5.0µA TA = 25°C
Rated DC Blocking 50µA TA = 100°C
Voltage
Typical Junction CJ 20pF Measured at
Capacitance 1.0MHz, VR=4.0V
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%

www.mccsemi.com
RL201 thru RL207
Figure 1
MCC
Typical Forward Characteristics
20
Figure 2
10 Forward Derating Curve
6 3.0

4
2.5
2
25°C
2.0
µAmps 1

.6
1.5
Amps
.4
1.0
.2

.1 .5
Single Phase, Half Wave
.06 60Hz Resistive or Inductive Load
0
.04 0 50 75 100 125 150 175

°C
.02
Average Forward Rectified Current - Amperesversus
.01 Ambient Temperature - °C
.2 .4 .6 .8 1.0 1.2
Volts
Instantaneous Forward Current - MicroAmperesversus
Instantaneous Forward Voltage - Volts

Figure 3
Junction Capacitance

100
60
40

20
pF TJ=25°C
10

6
4

1
.1 .2 .4 1 2 4 10 20 40 100 200 400 1000
Volts

Junction Capacitance - pFversus


Reverse Voltage - Volts

www.mccsemi.com
RL201 thru RL207 MCC
Figure 4 Figure 5
Typical Reverse Characteristics Peak Forward Surge Current
10 120

6 100
4
80
2
TJ=100°C 60
1
Amps
40
.6

.4 20

.2 0
1 2 4 6 8 10 20 40 60 80 100
Amps .1 Cycles
.06
Peak Forward Surge Current - Amperesversus
.04 Number Of Cycles At 60Hz - Cycles

TJ=25°C
.02

.01

.006

.00
4
.002

.001
20 40 60 80 100 120 140

Volts
Instantaneous Reverse Current - Ampsversus
Percent Of Rated Peak Reverse Voltage - Volts

www.mccsemi.com