Journal of Alloys and Compounds 385 (2004) 156–159

Characteristics of titanium–hydrogen solid solution


Daigo Setoyama∗ , Junji Matsunaga1 , Hiroaki Muta,
Masayoshi Uno, Shinsuke Yamanaka
Department of Nuclear Engineering, Graduate School of Engineering, Osaka University,
2-1 Yamada-oka, Suita, Osaka 565-0871, Japan

Received 28 January 2004; received in revised form 28 April 2004; accepted 28 April 2004

Abstract

The mechanical properties of titanium–hydrogen solid solution (0–7.84 at.% H) were studied to reveal the influence of hydrogen on the
characteristics of titanium. The elastic moduli such as Young’s and shear moduli of titanium–hydrogen solid solution decreased with increasing
of hydrogen content. The influence of hydrogen content for decreasing of elastic moduli was independent of temperature. The microhardness
for the solid solution was also decreased with increasing of hydrogen content. The electronic structure of the titanium–hydrogen solid solution
was evaluated by a first principle molecular orbital calculation. The mechanical properties of titanium–hydrogen solid solution were discussed
in terms of the calculation results.
© 2004 Elsevier B.V. All rights reserved.

Keywords: Titanium–hydrogen solid solution; Molecular orbital method; Elastic modulus; Hardness

1. Introduction theoretically, using by the first principle molecular orbital


calculation [7].
Titanium and its alloys have been extensively utilized in
various fields such as chemical plants, nuclear materials [1]
and aerospace components, because the titanium alloys have
2. Experimental procedure
high chemical durability as well as high strength. The infor-
mation on the mechanical properties of titanium is therefore
The pure titanium (99.9%) polycrystalline cantilever
necessary and has therefore been studied [2–4] to develop
(45 mm × 10 mm × 1 mm) was used in the present study.
titanium-based alloys. On the other hand, titanium is paid
The modified Sievert’s UHV apparatus executed the hy-
attention as hydrogen storage material since titanium has
drogenation of the titanium. The hydrogen content of the
high affinity on hydrogen. However, it is generally said that
specimens was measured by hydrogen analyzer (HORIBA,
hydrogen pickup weakens the material strength, and the in-
EMGA-621). The details of these conditions were described
formation on the hydrogen embrittlement of titanium is still
in our previous paper [8]. The elastic moduli were obtained
inadequate. Yamanaka et al. [5,6] reported that the mechan-
by high temperature multiple elastometer (NTP, EG-HT),
ical properties of zirconium in the IV group are deteriorated
based on the cantilever characteristic vibration technique.
by hydrogen addition. Therefore, it is possible that titanium
The characteristic vibration frequencies were between 12
is also affected by hydrogen. From such points of view, the
and 16 Hz. The Vickers hardness was measured by high
mechanical properties of titanium–hydrogen solid solution
temperature Vickers hardness tester (NIKON, QM-1). The
were studied by means of not only experimentally but also
test was repeated five times on each temperature. The hy-
drogen content of the samples and the range of temperature
∗ Corresponding author. Tel.: +81-6-6979-7905;
for these tests are illustrated in the Ti–H diagram (Fig. 1).
fax: +81-6-6879-7889. The electronic structures of the hydrogen solid solu-
E-mail addresses: dsetoya@stu.nucl.eng.osaka-u.ac.jp (D. Setoyama),
j-matsunaga@stu.nucl.eng.osaka-u.ac.jp (J. Matsunaga).
tion have been evaluated by a first-principles molecular
1 Co-corresponding author. Tel.: +81-6-6879-7905; orbital (MO) calculation. The MO calculations were per-
fax: +81-6-6875-7889. formed by the DV-X␣ cluster method based on the local

0925-8388/$ – see front matter © 2004 Elsevier B.V. All rights reserved.
doi:10.1016/j.jallcom.2004.04.132
D. Setoyama et al. / Journal of Alloys and Compounds 385 (2004) 156–159 157

Fig. 1. The hydrogen content and measured temperature range of the


samples in the Ti–H phase diagram.

density function approximation. The DV-X␣ method is a


non-relativistic first principles method using Slater’s X␣
potential as the exchange-correlation term. The details of
the DV-X␣ method have been discussed at length in the
literature [9–11].

3. Results and discussion

Fig. 2 shows the changes of Young’s moduli on hydrogen


content and temperature. The solid marks indicate the re-
sults of solid solution (␣ phase), the open marks indicate the Fig. 2. (a) Change in the Young’s modulus E for hydrogenated Ti with
hydrogen content; (b) change in the Young’s modulus E for hydrogenated
results of two phase area which consist of both precipitated Ti with temperature.
hydride and matrix (␣ + ␦ phase). In Fig. 2a, the Young’s
modulus of ␣-Ti decreased with increasing of hydrogen
content. The decreasing of the modulus was independent Therefore, the decreasing of shear modulus was fitted by
of temperature. The slope dE/dCH was −1.73 GPa/at.% H. the following equation:
Fig. 2b shows that the change of Young’s modulus on tem- G = 42.5 − 0.033T − 0.946CH (GPa) (2)
perature change. In the ␣ phase area, the Young’s modulus
also decreased with increasing of temperature, which is in where G, T, CH are shear modulus (GPa), temperature (◦ C)
good agreement with the reported tendency [3] (solid line and hydrogen content (at.%), respectively. The dashed lines
and dotted line). The decreasing of the modulus was also in the Figs. 3a and 2b are drawn by the above equation.
independent of hydrogen content. The slope dE/dT was The solid and dotted lines are from the literature [3]. The
−0.059. Therefore, the decreasing of Young’s modulus was Vickers hardness of solid solution is shown in Fig. 4. The
fitted by the following equation: Vickers hardness also decreased with hydrogen addition
and temperature. From this result, the Vickers hardness was
E = 127.9 − 0.059T − 1.73CH (GPa) (1)
fitted by the following equation:
where E, T, CH are Young’s modulus (GPa), temperature Hv = 188 + 9.55 × 10−4 T 2 − 0.71T − 1.50CH (3)
(◦ C) and hydrogen content (at.%), respectively. The dashed
lines in the Fig. 2a and b is drawn by the above equation. where Hv , T and CH are Vickers hardness, temperature
In the ␣ + ␦ phase area, the elastic moduli did not de- (◦ C) and hydrogen content (at.%), respectively. The dashed
crease with increasing of hydrogen content, because of the lines in the Fig. 4a and b is drawn by the above equation.
higher Young’s modulus of the hydride. And these results The hydrogen solution softens the mechanical properties of
are consistent with the reference data [3]. Fig. 3 shows the titanium elastically and plastically.
change of shear moduli on hydrogen content and tempera- The electronic structure of titanium–hydrogen solid so-
ture. The open and solid marks indicate the same meaning lution was evaluated by the first principle molecular orbital
in Fig. 2. It was also found that the decreasing of shear calculation. The lattice parameters and hydrogen content
modulus had same tendency as that of Young’s modulus. of the ␣ phase-titanium clusters are shown in Table 1 [12].
158 D. Setoyama et al. / Journal of Alloys and Compounds 385 (2004) 156–159

Fig. 3. (a) Change in the shear modulus G for hydrogenated Ti with


hydrogen content; (b) change in the shear modulus G for hydrogenated
Ti with temperature.

The same lattice parameters were adopted for every cluster


(Fig. 5). The hydrogen contents are 0, 2.70, 5.26, 7.69 at.%, Fig. 4. (a) Change in the Vickers hardness Hv for hydrogenated Ti with
hydrogen content; (b) change in the Vickers hardness Hv for hydrogenated
respectively. A smearing technique [13,14] was applied for Ti with temperature.
the problem in our systems containing many heavy metal
atoms. In smearing technique, the Fermi energy was cal-
culated using the Gaussian broadening technique with a
smearing parameter of 0.05 eV. Fig. 6 shows change of total
bond order between all of Ti pairs. Bond order is a crite-
rion of covalent binding [15]. The bond order between Ti
atoms decreased with the increasing of hydrogen content.
Fig. 7 shows the density of states of solid solution. The
peak of hydrogen 1s orbital can be seen around −5 eV by
the solution of hydrogen. Moreover, 3d orbital of titanium
decreased with increasing of hydrogen content. It was con-
sidered that the bonding between titanium atoms decreases

Table 1
The parameters of cluster models
Cluster model Lattice parameter (Å) Hydrogen content
(at.% H)
a-axis c-axis

Ti36 2.9506 4.6835 0.00


Ti36H1 2.70
Ti36H2 5.26
Fig. 5. The cluster models of (a) Ti36; (b) Ti36H1 (2.70 at.% H); (c)
Ti36H3 7.69
Ti36H2 (5.26 at.% H); and (d) Ti36H3 (7.69 at.% H).
D. Setoyama et al. / Journal of Alloys and Compounds 385 (2004) 156–159 159

Fig. 8 shows the distribution of charge density around a


hydrogen atom on titanium–hydrogen solid solution cluster.
The bond between the center of hydrogen atom and the first
nearest titanium atoms (Ti(a) ) is visible, but those between
titanium atoms are not easy to see. In contrast, the bond
between the first nearest titanium (Ti(a) ) and the second
nearest titanium atoms (Ti(b) ) are formed strongly. This
distribution of the charge density is proof of decreasing of
bonding power between titanium atoms by hydrogenation.

4. Conclusion

The mechanical properties were studied for titanium–


hydrogen solid solutions. The elastic moduli such as
Young’s and shear moduli of titanium–hydrogen solid solu-
Fig. 6. Change in the total bond order of the clusters for hydrogen solid
tion decreased with increasing of hydrogen content. Solute
solution with the hydrogen content.
hydrogen was found to lead the reduction of the microhard-
ness of Ti.
The electronic structure of the titanium–hydrogen solid
solution was estimated by molecular orbital calculation. It
was found from the calculation that the solute hydrogen
atom in an interstitial site drew off the 3d electrons from the
metallic bond onto the Ti–H bond. This appears to weaken
the surrounding metallic bonds. These results provide an
explanation for the change in the mechanical properties of
Ti with hydrogen addition.

References

Fig. 7. Density of states from (a) Ti36; (b) Ti36H1; and (c) Ti36H2 cluster. [1] K. Ishiguro, K. Kawamura, H. Sonobe, M. Nodaka, T. Arai, Y. Yusa,
N. Tsunoda, Nucl. Eng. Des. 116 (1) (1989) 61–70.
[2] Handbook of International Alloy Compositions and Designations,
vol. 1.
[3] O.N. Senkov, M. Dubois, J.J. Jonas, Metall. Mater. Trans. A 27 (A)
(1996) 3963–3970.
[4] O.N. Senkov, J.J. Jonas, Metall. Mater. Trans. A 27 (A) (1996)
1877–1887.
[5] S. Yamanaka, K. Yoshioka, M. Uno, M. Katsura, H. Anada, T.
Matsuda, S. Kobayashi, J. Alloys Compd. 293/295 (1999) 23–29.
[6] S. Yamanaka, K. Yamada, K. Kurosaki, M. Uno, K. Takeda, H.
Anada, T. Matsuda, S. Kobayashi, J. Alloys Compd. 330/332 (2002)
313–317.
[7] Y. Song, Z.X. Guo, R. Yang, Philos. Mag. A 82 (7) (2002) 1345–
1359.
[8] S. Yamanaka, T. Tanaka, M. Miyake, J. Nucl. Mater. 167 (1989)
231–237.
[9] J.C. Slater, Phy. Rev. 81 (1951) 385.
[10] D.E. Ellis, H. Adachi, F.W. Averill, Sur. Sci. 58 (1976) 497.
[11] H. Adachi, M. Tsukada, C. Satoko, J. Phy. Soc. Jpn. 45 (1978) 875.
Fig. 8. The distribution of charge density for (2 0 2 3) plane of Ti36H3 [12] A. San-Martin, F.D. Manchester, The H–Ti (hydrogen–titanium) sys-
cluster. tem, Bull. Alloy Phase Diag. 8 (1987) 30–42.
[13] C. Elsasser, M. Fahnle, C.T. Chan, K.M. Ho, Phys. Rev. B 49 (1994)
13975.
because the electrons of 3d orbital used between titanium [14] R.W. Warren, B.I. Dunlap, Chem. Phys. Lett. 262 (1996) 384.
atom and hydrogen atom. This analysis can explain the [15] M. Mizuno, I. Tanaka, H. Adachi, Phys. Rev. 59 (1999) 15033–
experimental results of the softening qualitatively. 15047.