DOCUMENT NUMBER Page 1 of 4

Pressure Differential Indicator CONTRACT NO: SC/TECH/020/17


OSP078-IC-DAS-8009-Rev.0
Datasheet OTEC PROJECT NO.: OSP078

United Gas Derivatives Company (UGDC)

Engineering Works for Utilizing Secondary Gas in High Pressure Mode

0 08.03.2018 Issued for Client Review S Abdo A Saleh A Fawzi


Rev Date Issuance Purpose Prep’d Chk’d App’d
Onspec Tawakol Engineering and Contracting
Engineering Works for Utilizing Secondary Gas in High Pressure Mode
Pressure Differential Indicator Datasheet

Page 2 of 4
Changes List
Date
Rev. prepared Prepared by Description
(DD-MM-YYYY)
Onspec Tawakol Engineering and Contracting
Engineering Works for Utilizing Secondary Gas in High Pressure Mode
Pressure Differential Indicator Datasheet

Page 3 of 4
Index

Sheet Description

1 Cover Page

2 Change List

3 Index

4 01-PDI-60 Datasheet
Onspec Tawakol Engineering and Contracting
Engineering Works for Utilizing Secondary Gas in High Pressure Mode
Pressure Differential Indicator Datasheet

Page 4 OF 4
Pressure Differential Indicator Datasheet

1 Instrument Tag No. 01-PDI-60 25 Gauge Dial Size 150 mm (6 inch)

26 Casing & bezel 316 SS, ENP ( Note.13 )


From GASCO GAS Supply Pipeline, Pressure
2 Service & Location Material
Differential Indicator Across (SDV-09)
27 Window Laminated Safety Glass

01-GD-P-04015-2

Housing
General

3 P&ID No. / Skid No. 28 Process Connection Size ½" NPT (M)
SHEET 2 OF 2

4 Vessel No \ Line No. Across Shutdown Valve (SDV-09) 29 Process Connection Entry Bottom

5 Type: Pressure/Vacuum/Diff. Pressure Diff. Pressure 30 Solid Front Required

6 Manufacture & Model no. VTA 31 Blow Out Protection Back

7 Standard EN-837-1 32 Enclosure IP 65

8 Process Fluid Gas 33 Valve Manifold 5 way Manifold Integral with Indicator

9 Inlet Pressure / Outlet Pressure (barg) 60/Atm 34 Valve Manifold Connection ½" NPT (F)

Manifold
10 Design Pressure (barg) 79 35 Manifold Material 316 SS, ENP ( Note.13 )
Process Data

11 Differential Pressure (bar) 0-60 36 Manifold Vent / Drain Connection ¼" NPT (F)

12 Operating Temperature ° C 40 37 Manifold Isolation Handle Removal Type with tag Isolate & Vent
Ambient Conditions

13 Design Temperature °C 85 38 Air Temp minimum °C 5

14 Entrained Soilds / Corrosion Allowance No 39 Air Temp maximum °C 40

15 Sour Service No 40 Rel. Humidity minimum % 30

16 Element Type Bourdon C Tube 41 Rel. Humidity maximum % 98

17 Element Material 316 SS, ENP ( Note.13 )

18 Movement Material 316 SS, ENP ( Note.13 )

19 Process Connection ½" NPT (M)


Element

20 Measuring Range (barg) 0 - 80 barg

21 Zero & Span Adjustment Internal

22 Static Pressure (barg) 60

23 Over range Protection % 130%

24 Accuracy ± 0.5 % or better

Notes:

1) VTA = Vendor to Advise

2) Pressure Differential Indicator shall be equiped with 5 way manifold

3) Vendor to provide complete fittings, mounting brackets sets, etc. necessary to Pressure differential Indicator installation

4) Pressure Differential Indicator shall have SS tag tied with SS wire or on the body of Pressure Differential Indicator

5) Vendor to provide spare parts required for pre-commissioning, commissioning and startup (If any)

6) All instruments shall be Ultra Violet resistance

7) Wetted parts material of tubing or any other accessories needed for each instrument shall be same as wetted parts material off the instrument.

8) Pressure Differential Indicator scale range shall be selected such that the normal pressure shall be indicated within 30 - 70% of the full range

9) Vendor to provide certificates, i.e UL/FM certificate, etc.

10) Vendor to provide calibration certificate

11) Vendor to provide a detailed installation drawings

12) Vendor to provide a complete datasheet

13) UGDC to confirm as per ENPPI class.

You might also like