Field Report-Shamekh DG2
* PROBLEM FOUND
* ATTENDED THE GENSET,WALK AROUND INSPECTION CARRIED OUT.
* REMOVED THE VALVE TOP COVER AND INSPECTED FOR ANY LOOSE CONNECTION ,NOTHING FOUND.
* PERFORMED INJECTOR SOLENOID TEST FOUND INJECTOR NO:2 HAVING SHORT CIRCUIT(ATTACHED
THE TEST REPORT IN MAIL)
* FOUND THAT THE CODE : Cylinder #2 Injector : Other Failure Mode & Cylinder #4 Injector : Other
Failure Mode , ARE IN ACTIVE MODE.
* FOUND INJECTOR NO2 INJECTOR SOLENOID IS DEFECTED.
* PROBLEM CAUSES
* ON THE PREVIOUS REPORT ON 20/03/2021 SUSPECTED THE POSSIBLE CAUSES CAN INJECTORS
HARNESS & INJECTORS.