Download as pdf or txt
Download as pdf or txt
You are on page 1of 128

Product Data Sheet 00813-0100-4761; DS-4010

ProBar® Flowmeter
WHEN COMPARED WITH TRADITIONAL
DP FLOW MEASUREMENT, THE
PROBAR FLOWMETER OFFERS
GREATER VALUE AND PERFORMANCE
HIGH PERFORMANCE
• ±0.5% of rate reference accuracy
• 10:1 flow turndown
• Liquids
• Gases and steam (Consult Factory)

ProBar®
• 4—20mA and HART® flow outputs
REDUCED INSTALLATION COSTS
• Installation time reduced by 90%
• Fugitive emission points reduced by 80%
• NEW 2-line scalable display
REDUCED OPERATING COSTS
• Significantly lower pressure drop than
orifice or vortex meters
• Low operating costs
• Low maintenance costs
HIGH RELIABILITY
• ISO 9001 company
• NIST Traceable Calibration

COMPLETE POINT SOLUTIONS™ We complement our field instruments with a wide


Complete Point Solutions provides fully engineered range of technologies; including, manifolds,
measurement solutions, combining best product and primary elements, process flanges and seals, and
practices for improved performance, reliability, temperature sensors and accessories.
and cost of ownership.
Complete Point Solutions is designed to provide you
The capability of the world’s finest industrial with Best-in-Class equipment — allowing you to
measurement instrumentation is further increased save on installation costs, and improve the reliability
by combining it with a premier offering of and capability of your process.
complimentary products. This system is engineered
and assembled by Rosemount Inc. to make it Take advantage of our vast experience in process
easy for you to specify and order the correct measurement, and start improving your process
equipment for your process measurement needs. with Complete Point Solutions.

Flow-247
ProBar® Flowmeter

PROBAR
FLOWMETER
PROBAR FLOWMETER- - - - - - - - - - - - - - - - - - - - - - - - - - 251
REINVENTING DP FLOW MEASUREMENT - - - - - - - - - - - - - 251

Per fo rm a nc e
THE PROBAR FLOWMETER - - - - - - - - - - - - - - - - - - - - - - 252

B e ne fits
LOW INSTALLATION COSTS - - - - - - - - - - - - - - - - - - - - - - 254
LOW OPERATING COSTS - - - - - - - - - - - - - - - - - - - - - - - - 255
ProBar®

F e atu re s
FEATURE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 256
BENEFIT- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 256

I n s tal l at i on
( Fo l l ow th e P I PE S P l a n for Q ua l i t y I n s tal lat ion .)
PIPE ORIENTATION - - - - - - - - - - - - - - - - - - - - - - - - - - - 257
INSIDE PIPE DIAMETER (ID) - - - - - - - - - - - - - - - - - - - - - 257
PIPE PENETRATION - - - - - - - - - - - - - - - - - - - - - - - - - - - 257
ELECTRONIC MOUNTING - - - - - - - - - - - - - - - - - - - - - - - 258
STRAIGHT RUN - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 258

S iz ing a nd H ow To Ord er
1. CHOOSE A MOUNTING METHOD - - - - - - - - - - - - - - - - - 259
2. CHOOSE A SENSOR SIZE - - - - - - - - - - - - - - - - - - - - - - 260
3. VERIFY MODEL AND SENSOR SIZE - - - - - - - - - - - - - - - 261
4. CHOOSE THE M ODEL OOPTIONS - - - - - - - - - - - - - - - - - 263
5. VERIFY PROCESS AND PIPE INFORMATION - - - - - - - - - - 264

Flow-248
Rosemount Inc.

PROBAR
FLOWMETER
O rde ri n g I n fo rm a ti o n— Mo d el PB R
MODEL PBR+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - - 265
MODEL PBR+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - - 267
MODEL PBR+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - - 270
MODEL PBR+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - - 273
O rde ri n g I n fo rm a ti o n— Mo d el PB F
MODEL PBF+15S/16S - - - - - - - - - - - - - - - - - - - - - - - - - 281
MODEL PBF+25S/26S - - - - - - - - - - - - - - - - - - - - - - - - - 284
MODEL PBF+25H/26H - - - - - - - - - - - - - - - - - - - - - - - - 287
MODEL PBF+35S/36S - - - - - - - - - - - - - - - - - - - - - - - - - 293

ProBar®
MODEL PBF+45S/46S - - - - - - - - - - - - - - - - - - - - - - - - - 296
MODEL PBF+45H/46H - - - - - - - - - - - - - - - - - - - - - - - - 299
MODEL PBF+45M/46M - - - - - - - - - - - - - - - - - - - - - - - - 302
O rde ri n g I n fo rm a ti o n— Mo d el PN T
MODEL PNT+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 310
O rde ri n g I n fo rm a ti o n— Mo d el PN F
MODEL PNF+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 312
MODEL PNF+10H - - - - - - - - - - - - - - - - - - - - - - - - - - - - 314
MODEL PNF+10M - - - - - - - - - - - - - - - - - - - - - - - - - - - 316
O rde ri n g I n fo rm a ti o n— Mo d el PN W
MODEL PNW+10S - - - - - - - - - - - - - - - - - - - - - - - - - - - 318
O rde ri n g I n fo rm a ti o n— Mo d el PH T
MODEL PHT+15S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 325
MODEL PHT+25S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 328
MODEL PHT+35S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 331
O rde ri n g I n fo rm a ti o n— Mo d el PH F
MODEL PHF+15S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 340
MODEL PHF+25S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 343
MODEL PHF+25H - - - - - - - - - - - - - - - - - - - - - - - - - - - - 346
MODEL PHF+25M - - - - - - - - - - - - - - - - - - - - - - - - - - - 349
MODEL PHF+35S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 352
MODEL PHF+45S - - - - - - - - - - - - - - - - - - - - - - - - - - - - 355
MODEL PHF+45H - - - - - - - - - - - - - - - - - - - - - - - - - - - - 358
MODEL PHF+45M - - - - - - - - - - - - - - - - - - - - - - - - - - - 361

S p ec i fi c a ti o ns
FUNCTIONAL SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - 371
PERFORMANCE SPECIFICATIONS- - - - - - - - - - - - - - - - - - - 372
PHYSICAL SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - - - 373
SENSOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 373

Flow-249
ProBar® Flowmeter
ProBar®®

Flow-250
Rosemount Inc.

PROBAR®
Flowmeter

ProBar®
PROBAR FLOWMETER Dieterich Standard, Inc. has REINVENTING DP
joined with Rosemount Inc. to FLOW MEASUREMENT
The ProBar flowmeter is a provide the latest technology in
highly accurate insertion DP flow solutions. Rosemount Inc. By combining integrated
flowmeter. It measures is the technology leader in electronics with insertion
volumetric flow rate for liquids, offering the highest performance flowmeter technology, the
gases, and steam in line sizes and highest quality in DP ProBar flowmeter provides the
from ½-inch to 72 inches. With transmitters. The 3051CD™ lowest total cost of any precision
fully integrated Rosemount® provides 0.075% accuracy, 100:1 flowmeter. Installation costs are
electronics and the Annubar® rangeability, and the best stability reduced by insertion through a
sensor, the ProBar flowmeter of any industrial transmitter. In small tap into existing piping,
provides a ±0.5% of rate the years since its introduction, and no plumbing is required
reference accuracy over a the 3051CD has become the new between the electronics and the
10:1 flow turndown. By fully standard in DP sensing sensing element. Due to the
calibrating the integral ProBar technology. aerodynamic shape of the
flowmeter, Dieterich Standard, sensing element, the ProBar
Inc. has eliminated the “percent As a member of the Rosemount flowmeter provides low
of full scale” accuracy and Inc. team, Dieterich Standard, operating costs. In addition, the
turndown limitations associated Inc. combines 3051CD based sensor is insensitive to wrap,
with differential pressure electronics with the latest in wear, and plugging. When
(DP) technology. DP primary technology— compared with traditional DP
Diamond II+ Annubar primary flow measurement, the ProBar
flow element. flowmeter offers greater value
and performance. Together,
Dieterich Standard, Inc. and
Rosemount Inc. are reinventing
DP flow measurement.

Flow-251
ProBar® Flowmeter

Performance

THE PROBAR FLOWMETER Compared to Traditional


DP Flow Measurement
Reference Accuracy ± 0.5%
When compared to traditional DP flow measurement,
and Turndown 10:1 ProBar flowmeter improves the “percent of full scale”
The ProBar flowmeter has better performance errors caused by the transmitter at high turndowns,
than vortex, insertion turbine, or DP flowmeters. and error caused by the primary element over the
Based on proven technology and NIST traceable entire turndown. When comparing a ProBar flowmeter
calibration, the ProBar flowmeter is far superior to an orifice plate and DP transmitter at a 10:1 flow
to “percent of full scale” DP flowmeters. turndown, the ProBar flowmeter maintains a ±0.5%
reference accuracy while the errors caused by “percent
of full scale” limitations of the transmitter can lead
to a 5% inaccuracy.
ProBar®

FIGURE 1. Accuracy % Rate.

Sensor Design is Based on Proven


Annubar Primary Flow Element Technology
The ProBar flowmeter is based on DP flow
measurement technology. A DP is generated FIGURE 4. ProBar DP Flow Measurement.
across the third generation Diamond II+ Annubar
sensor. The linearity of the Diamond II+ is the
key to the ProBar flowmeter’s accuracy and
turndown capabilities. The DP signal generated is
proportional to the flow rate in accordance with
Bernoulli’s Theorem.

2 2
V1
---------- + P1
------- = V2
---------- + P2
-------
2gc ρ 2gc ρ

FIGURE 2. Bernoulli’s Theorem.

FIGURE 3. Diamond II+ Design.


Diamond II+ design provides a fixed separation point
for linear, repeatable performance.

Flow-252252
Rosemount Inc.

Smart electronics Patented Characterization Process


linearize the
flowmeter over a wide
flow turndown. With The ProBar flowmeter is calibrated over a wide
ProBar flowmeter turndown in a NIST traceable calibration flow
electronics, the laboratory. A characterization curve is formed and
specifications can be
maintained for five programmed into the electronics. The result is a
years with no linearized flowmeter that matches the actual
adjustments. A volumetric flow rate with a +0.5% reference accuracy.
4—20mA output
proportional to flow
rate and HART C ha ract eriza tio n Test
communications
is standard.

Integrated 1
manifold for 2
F l ow Tu rn do wn
isolation and
calibration
3
4

ProBar®
5

Verif i catio n Test


Optional integral F l ow Tu rn do wn
RTD (not shown)
FIGURE 6. Patented Characterization Process.

Patented The Probar Flowmeter Calibration Process


Pak-Lok®
mounting
for safe 1. Reference flow is introduced to the ProBar
installation The sensor spans the entire flowmeter in a NIST traceable laboratory.
or optional pipe and senses the flow 2. The ProBar flowmeter output is recorded
flange profile. Calibrated in a NIST
mounting over flow range.
traceable flow laboratory, it
has proven reliable in 3. Statistical regression analysis is used to
hundreds of thousands arrive at the characterization curve.
of applications. 4. The Characterization curve is programmed
into the ProBar flowmeter electronics via
patented process.
5. The ProBar flowmeter is tested a second time
for verification of +0.5% of rate accuracy — a
calibration test record is generated.

Test Data
The ProBar flowmeter calibration process provides
an actual calibration test record that shows the
ProBar flowmeter maintains +0.5% accuracy over a
10:1 flow turndown at reference conditions. Each
ProBar flowmeter comes with a certified NIST
traceable report that shows the results from the
Dieterich Standard, Inc. flow laboratory.

FIGURE 5. ProBar Flowmeter Diagram. FIGURE 7. Certified NIST Traceable Report.

Flow-253
ProBar® Flowmeter

Benefits

LOW INSTALLATION COSTS Compare ProBar Flowmeter


Installation Costs
Compare ProBar Flowmeter Installation
When compared to an orifice and vortex installation,
The ProBar flowmeter offers low installation costs the ProBar flowmeter saves installation and
when compared to traditional DP flow measurement. hardware costs while offering superior accuracy and
The fully integrated electronics and sensor eliminate turndown. The larger the line size, the more value
fittings, tubing, valves, manifolds, adapters, and the ProBar flowmeter offers.
mounting brackets and reduce welding and
installation time.
6 inch (150 mm) pipe,
See the ProBar flowmeter manual for the recommended water 300# ANSI
installation of the ProBar flowmeter. Flowmeter or sensor
Mounting hardware
ProBar®

Transmitter
Manifold, valves & bracket
Weld (mounting)
Fittings & Tubing
Wiring
Start-up (Cal/Config)

ProBar Flowmeter
Vortex
Orifice
Traditional DP ProBar Flowmeter
Installation FIGURE 9. Installation Cost Comparison.
Installation
Ref: 6”SCH40, 100# Steam, 11,300PPH

FIGURE 8. ProBar Flowmeter vs. Traditional DP. Easy Plug-And-Play Installation


The ProBar flowmeter provides the lowest cost
Traditional ProBar Flowmeter installation of any precision flowmeter. The easy
16 Fittings & tubing 0 “plug-and-play” installation of the ProBar flowmeter
4 Valves 0 includes four steps:
1 Manifold Integral
1. Drill a hole into the existing process piping.
2 Adapter unions 0
2. Weld a fitting onto the pipe.
1 Transmitter mounting 0 3. Insert the ProBar flowmeter.
bracket
4. Wire to the DCS, recorder, or HART host.
50 linear inches Welding 4 linear inches
33 Leak points 6

TABLE 1. ProBar Flowmeter vs. Traditional DP.

FIGURE 10. Plug-and-Play Installation.

Flow-254254
Rosemount Inc.

LOW OPERATING COSTS Low Maintenance Costs

Low Permanent Pressure Loss The ProBar flowmeter sensor shape is designed to
prevent wear and plugging that could affect
The ProBar flowmeter has the lowest pressure drop calibration. The electronics are the most stable in
and operating cost of any DP or vortex flowmeter. the industry and will not drift outside of the total
The aerodynamic shape of the ProBar flowmeter performance specification. Recalibration should not
does not restrict the flow like the bluff body of a be required in a five-year period, providing
vortex shedder or the restrictive opening of an significant savings in maintenance costs.
orifice plate.

ProBar®
FIGURE 13. Non-plug design.

Reliability
• ISO 9001 certified

FIGURE 11. Permanent Pressure Loss. • NIST traceable calibration


Ref: 6”SCH40, 100# Steam, 11,300PPH

• Proven technology supplied by


Energy Cost Saving leading manufacturers
Permanent pressure loss can be converted directly
into energy costs in the form of compressor costs for • 300 sales and service centers in 120 countries
gas, electrical costs for pumping liquids, and fuel
costs for generating steam. Energy savings increase • 90 years experience in flow
with line size and flow rate. The payback time for a measurement solutions
ProBar flowmeter can be as short as six months in
energy savings alone. Contact your local salesperson
for a cost savings analysis of your application. ÿþ ý
ÿþý þ
þ

ÿþýüýýý

ÿüýýý

ÿþüýýý

FIGURE 14. ProBar Flowmeter Reliability.


ÿýý

ÿý

ÿþý

4” 8” 12” 14”
(100mm) (200mm) (300mm) (400mm)

ProBar Flowmeter
Vortex
Orifice

FIGURE 12. Energy Costs.


Ref: 6”SCH40, 100# Steam, 11,300PPH

Flow-255
ProBar® Flowmeter

Features
FEATURE BENEFIT
Integral RTD Integrated Electronics Mounting

A three wire 100 Ω platinum RTD is inserted into a A single pipe


sealed, pressure retaining thermowell in the sensor. penetration allows
Connections are made through an explosion-proof measurement of
junction box. mass flow, including
temperature.
Designs by other vendors that do not provide a sealed FIGURE 15. Integral RTD.
thermowell are a potential hazard when removal
of the RTD is required. The integral RTD eliminates
hardware and installation costs.
Pak-Lok® Mounting
Pak-Lok mounting seals and secures the ProBar Allows safe and
flowmeter firmly against the inside opposite wall simple installation
ProBar®

simply and without high torque requirements. This of ProBar flowmeter.


design safely retains the sensor under high process
pressures. It also provides additional structural
support by placing the sensor in compression.
FIGURE 16. Pak-Lok Mounting.
Flanged Pipe Section
A good installation of the sensor is assured with The ProBar
the flanged pipe section option. The pipe can be flowmeter can be
made to any length for easy replacement of other mounted in a flanged
piping components. pipe section for easy
installation between
existing flanges.
FIGURE 17. Flanged Pipe Section.
Direct Mount Integral Manifold
The ProBar flowmeter electronics can be mounted Allows the
directly to the sensor by means of either a 3- or electronics to be
5-valve manifold. Upwards of 28 potential leak mounted directly
paths can be eliminated. The integral mount can to the sensor,
be used in all fluids except where the temperature eliminating costs
exceeds 500 °F (260 °C). and leak paths. FIGURE 18. Direct Mount
Integral Manifold.
Elbow Mount
ProBar flowmeter can be installed two pipe diameters ProBar flowmeter
from the centerline of an elbow and still provide good can achieve good
accuracy and repeatability: +3% without calibration. accuracy two
pipe diameters
from an elbow.
FIGURE 19. Elbow Mount.
Flo-Tap ProBar Flowmeter
Flo-Tap ProBar flowmeter is perfectly suited to Allows insertion and
retrofit applications because the Flo-Tap can retraction without
be hot-tapped without interruption of the flow, system shutdown.
and without system shutdown.
Bi-directional Flow Measurement
The symmetrical design, along with the controlled A single ProBar
separation point provided by the exclusive flowmeter can
diamond–shaped sensor means a single ProBar provide accurate FIGURE 20. Bi-directional
flowmeter is all that is required for bi-directional bi–directional Flow Measurement.
flow measurement. flow measurement.

Flow-256
Rosemount Inc.

Installation (Follow the PIPES Plan for Quality Installation.)

The performance of any flow measurement device INSIDE PIPE DIAMETER (ID)
depends greatly upon the quality of the installation.
This is also true for ProBar flowmeter. Studies have It is important to use the exact pipe ID in ProBar
shown that greater than 70% of flow measurement flowmeter installations to avoid flow measurement
problems are traceable to installation error. errors. Throat diameter is a squared factor for
Installation of ProBar flowmeter is very simple, but DP flow measurement devices. With the ProBar
attention must be paid to simple principles. These flowmeter, the pipe itself forms the throat. Using
principles are common to all DP devices and most the pipe as the throat of the meter reduces
flowmeters in general. The Dieterich Standard, Inc. permanent pressure loss and the effect of wear
acronym for these principles is “PIPES”: on the throat.

Pipe orientation
2
Flow = CD DP
Inside diameter

ProBar®
Pipe penetration

Electronics mounting

Straight run

PIPE ORIENTATION
The sensor must be installed in the proper
orientation relative to the pipe and the FIGURE 22. Pipe ID.
fluid measured. This must be specified at
the time of order placement. For gases, PIPE PENETRATION
the electronics must be mounted above the
pipe. For liquid and steam, the electronics The sensor mounting hole must be smooth and
must be mounted below the pipe. See the the correct size to avoid disturbing the flow profile.
I/O manual for detailed installation instructions. Drilling is the only acceptable method to properly
prepare the mounting hole. See hole size
recommendations in the manual 00809-0100-4761.
Preferred
Location
þý þý
Mounting

þý þý

ÿþý

Gas Installation Liquid or Steam Installation

FIGURE 21. Pipe Orientation.


FIGURE 23. Sensor Mounting Hole.

Flow-257
257
ProBar® Flowmeter

ELECTRONIC MOUNTING STRAIGHT RUN


Mounting of the electronics can be either integral or To obtain published accuracy, sufficient straight run
remote. Integral is preferred because of simplified is required to produce a fully developed flow profile.
installation, fewer leak points, faster response, and Shorter lengths are possible, but accuracy will be
greater accuracy. Remote mounting is required when affected. See Table 2 for recommended straight run
the process temperature exceeds 500 °F (260 °C) or requirements for the ProBar flowmeter.
when there is excessive vibration. Where remote
mounting of the electronics is required, it is Straight run requirements are also more stringent for
important that the orientation of the electronics achieving the highest accuracy. The recommended
relative to the sensor is correct. For gases, the values shown are upstream straight run requirements.
electronics must be above the sensor and for liquids, Four diameters are required downstream.
below the sensor. It is critical to review the I/O
manual on this topic and on commissioning.
Location With Vanes Without Vanes

After an elbow 8 10
ProBar®

Two elbows out of plane 8 28

After a modulating control valve 8 30

After an expansion 8 18

After a constriction 8 12

TABLE 2. Upstream Straight Run Requirements.

Integral Mounting Remote Mounting

FIGURE 24. Electronic Mounting.

Flow-258
Rosemount Inc.

Sizing and How To Order


1. CHOOSE A MOUNTING METHOD
PBR PBF

FIGURE 25. Regular Threaded FIGURE 26. Flanged.


Pak–Lok Assembly. Mounting Method

ProBar®
Mounting Method Flanged.
Threaded Pak–Lok. Pipe Sizes
Pipe Sizes 2 in. to 72 in. (50 mm to 1800 mm).
2 in. to 72 in.(50 mm to 1800 mm).
PHF PHT

FIGURE 27. High Pressure FIGURE 28. High Pressure


Flanged Flo–Tap. Threaded Flo-Tap.
Mounting Method Mounting Method
Flanged Flo–Tap for pressure Threaded Flo-Tap for pressure
equivalent to ANSI Class 600 Flanges. equivalent to ANSI Class 600 Flanges.
Pipe Sizes Pipe Sizes
2 in. to 72 in. (50 mm to 1800 mm). 2 in. to 72 in. (50 mm to 1800 mm).

PNF PNT PNW

FIGURE 29. Flanged In–Line. FIGURE 30. Threaded In-Line. FIGURE 31. Butt Weld In-Line.
Mounting Method Mounting Method Mounting Method
Flanged In–Line. Threaded In–Line. Butt Weld In–Line.
Pipe Sizes Pipe Sizes Pipe Sizes
½ in. to 2 in. (25 mm to 50 mm). ½ in. to 2 in. (25 mm to 50 mm). ½ in. to 2 in. (25 mm to 50 mm).

Flow-259
ProBar® Flowmeter

2. CHOOSE A SENSOR SIZE Conversions for Verifications of Flows


for Fluids Other Than Air and Water
The following table is a guideline for selecting
the correct sensor. 1. To convert GPM of water to GPM of any other
fluid, divide the maximum GPM by the square
root of the specific gravity of the liquid.
Sensor Pipe Sizes
GPM
10 - PNT, PNW & PNF ½ in. to 2 in.
GPM water
= -------------------------------
(DIN 15-DIN 50) other -
SG other
15/16 2 in. to 5 in.
(DIN 50-DIN 125)
2. To convert SCFM of air to SCFM of any other gas,
25/26 4 in. to 42 in.
(DIN 100-DIN 1000)
divide the max SCFM by the square root of the
specific gravity of the other gas.
35/36 10 in. to 72 in.
(DIN 200 to DIN 1800)
SCFM air
45/46 16 in. to 72 in. SCFM other = -----------------------------
ProBar®

(DIN 250 to DIN 1800) SG


other
TABLE 3. Sensors and Pipe Sizes.
3. To convert standard flow rates to actual flow
rates (gas):

Pf
35.302 × --------------------------- xACFM
( T f + 460 )
Pf = Flowing pressure (psia)
Tf = Flowing temperature (°F)

( T + 460°F )
f
ACFM × ----------------------------------- × SCFM
( P f × 35.302 )

4. To convert volume flow to mass flow:

3
GPM × DensityofLiquid ( lb ⁄ ft )
PPM = ----------------------------------------------------------------------------------------------
7.48

PPM = ACFM × DensityofGas

5. To convert U.S. to metric units:

LPM = GPM × 3.78533

lb ⁄ hr × 2.205 = kg ⁄ hr
3 SCFH
NM H = ------------------
35.37

Flow-260
Rosemount Inc.

3. VERIFY MODEL & SENSOR SIZE


Compare the maximum allowable flow below to your maximum flow rates.

Nom. Sensor 10
pipe
PNT PNF PNW
size (in
inches)
SCFM hw GPM SCFM hw GPM SCFM hw GPM
.5 180.52 1500 50.943 180.52 1500 50.943 180.52 1500 50.943
.75 307.79 1500 89.404 307.79 1500 89.404 307.79 1500 89.404
1 498.82 1500 144.9 498.82 1500 144.9 498.82 1500 144.9
1.25 765.68 1180 222.41 765.68 1180 222.41 765.68 1180 222.41
1.5 902.04 884 262.02 902.04 884 262.02 902.04 884 262.02
2 1174.9 552 341.28 1174.9 552 341.28 1174.9 552 341.28

ProBar®
Sensor 15 Sensor 16

PBR PBF PHF PBR PBF


SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM
2 1236.1 611 359.05 502.91 84.3 133.37 1555 967 451.7 1236.1 611 359.05 1322 699 384.04
2.5 1531.9 451 440.14 639.74 66.9 169.52 1886.4 699 547.95 1531.9 451 440.14 1641 529 476.68
3 2010.5 314 567.07 859.71 50.5 227.41 2408.7 478 699.65 2010.5 314 567.07 2175.3 380 623.82
3.5 2408.7 246 671.26 1046.1 41.7 276.37 2852.6 369 822.13 2408.7 246 671.26 2639.5 305 747.44
4 2816 199 777.38 1237.1 35.1 326.48 3331.3 294 944.89 2816 199 777.33 3126.9 253 876.53
5 3723.8 137 1013.6 1663.7 25.6 438.17 4364.9 195 1209.3 3723.8 137 1013.6 4213.3 180 1161.9

Sensor 25 Sensor 26

PBR PBF PHF PBR PBF


SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM
4 6263.45 1090 1819.4 2827.2 189 757.59 7347.5 1500 2134.3 6263.4 1090 1819.4 7047.5 1380 2047.1
5 8148.5 747 2366.9 3798.1 138 1017.3 10066 1140 2924 8148.5 747 2366.9 9366.4 987 2720.7
6 10088 549 2930.2 4839.5 107 1293.6 12299 816 3572.4 10088 549 2930.2 11783 749 3422.6
8 14100 346 4028.2 6867.4 71.2 1827.3 16486 489 4788.8 14100 346 4029.2 16570 494 4813.2
10 18737 235 5232.7 9125.3 50.2 2418.5 21270 318 6087.1 18737 235 5232.7 22053 348 6367.7
12 23218 174 6391.4 11299 38 2986.8 26142 228 7316.3 23218 174 6391.4 27773 263 7857.8
14 25971 147 7099.9 12665 32.6 3343.5 29131 190 8071.7 25971 147 7099.9 31411 226 8803.3
16 30390 116 8238.9 14829 26.1 3908.1 33874 147 9274.7 30390 116 8238.9 37265 182 10320
18 34880 94.2 9397.7 17017 21.4 4479.2 38584 117 10473 34880 94.2 9397.7 43086 149 11819
20 39558 77.7 10608 19311 17.8 5077.3 43384 94.5 11699 39558 77.7 10608 49210 124 13401
24 48768 55.7 12990 23901 13 6275.5 52897 66 14140 48768 55.7 12990 61463 90.6 16567
30 65577 35.6 17355 32211 8.43 8445.5 70325 41.1 18648 65577 35.6 17355 83933 59.3 22399
36 80406 25.2 21207 39598 6.03 10374 85555 28.6 22592 80406 25.2 21207 103900 42.6 27573
42 95305 18.8 25083 47023 4.53 12313 100650 21 26510 95305 18.8 25083 123750 32 32725

hw = maximum differential pressure in inches of water column. ½ in. to 24 in. Sch 40


SCFM = maximum air flow in standard cubic feet per minute 30 in. to 42 in. Sch Std.
GPM = maximum water flow in gallons per minute 48 in. to 72 in. Actual I.D.
At standard conditions: Air — 60 °F at 14.73 psia
Water — 60 °F, specific gravity 1.0, viscosity 1.12 centipoise

Flow-261
ProBar® Flowmeter

Nom. Sensor 35 Sensor 36


pipe
size (in PBR PBF PHF PBR PBF
inches)
SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM
8 20661 768 6001.4 9950.2 153 2678.7 24501 1080 7116.8 20661 768 6001.4 24387 1070 7083.8
10 26823 521 7791.3 13239 108 3547.4 31224 706 9069.8 26823 521 7791.3 32204 751 9351.3
12 32883 385 9507.2 16469 82.3 4395.6 37485 505 10088 32833 385 9507.2 39824 570 11568
14 37058 327 10589 18488 70.7 4923.8 41364 421 12015 37058 327 10589 44625 490 12962
16 43668 258 12287 21590 56.7 5760.1 48040 325 13791 43668 258 12287 52273 394 15184
18 50338 209 13998 24947 46.6 6609.8 55095 258 15553 50338 209 13998 60481 324 17429
20 57299 172 15783 28344 38.8 7496.1 62559 210 17439 57299 172 15783 69596 270 19774
24 71017 123 19303 36548 28.3 9259.1 76801 146 21031 71017 123 19303 87990 198 24491
30 96282 78.9 25837 47441 18.4 12477 103040 91.1 27763 96282 78.9 25837 121480 130 33165
ProBar®

36 118650 56 31613 58452 13.2 15348 125830 63.3 33611 118650 56 31613 151120 93.2 40783
42 141020 41.8 37402 69564 9.95 18248 148640 46.6 39491 141020 41.8 37402 181070 70.3 48505
48 163400 32.4 43205 80662 7.76 21144 171330 35.7 45353 163400 32.4 43205 211020 54.9 56240
60 208140 21.1 54825 102920 5.1 26954 216230 22.8 56991 206140 21.1 54825 270800 36.1 71712
72 253470 14.9 66623 125280 3.61 32793 261750 15.9 68822 253470 14.9 66623 330970 25.6 87327

Sensor 45 Sensor 46
PBR PBF PHF PBR PBF
SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM SCFM hw GPM
10 41878 1270 12165 20133 256 5461.5 45513 1500 13220 41878 1270 12165 45513 1500 13220
12 51142 940 14855 24994 195 6766.1 59210 1260 17199 51142 940 14855 61288 1350 17803
14 56913 797 16532 28092 168 7590.1 65325 1050 18975 56913 797 16532 68661 1160 19944
16 66100 630 19200 33012 135 8888.1 74858 808 21744 66100 630 19200 80698 939 23441
18 75353 511 21888 38019 111 10201 84461 642 24539 75353 511 21888 92738 774 26938
20 85108 422 24722 43418 93.2 11618 94565 521 27469 85108 422 24722 105460 648 30634
24 106480 303 30297 53975 68.2 14374 114620 364 33207 106480 303 30291 130590 475 37933
30 146170 194 40515 73415 44.7 19448 156190 226 43729 146170 194 40515 178800 313 51462
36 181760 138 49627 90648 32.1 23938 192700 157 52933 181760 138 49627 226020 226 63508
42 217210 103 58712 108240 24.3 28517 229510 116 62307 217210 103 58712 273660 171 75649
48 251110 78.8 67379 125770 19 33086 265390 88.6 71446 251110 78.8 67379 321370 134 87865
60 321930 51.5 85653 160730 12.5 42190 337470 56.8 89952 321930 51.5 85653 416410 88.4 112220
72 392880 36.3 103990 195900 8.86 51374 408770 39.4 108340 392800 36.3 103990 511830 62.8 136780

hw= maximum differential pressure in inches of water column. ½ in. to 24 in. Sch 40
SCFM = maximum air flow in standard cubic feet per minute 30 in. to 42 in. Sch Std.
GPM = maximum water flow in gallons per minute 48 in. to 72 in. Actual I.D.
At standard conditions: Air — 60 °F at 14.73 psia
Water — 60 °F, specific gravity 1.0, viscosity 1.12 centipoise

Flow-262
Rosemount Inc.

4. CHOOSE THE MODEL OPTIONS

Model Numbers Description Page Numbers


®
PBR+15/16S ProBar + Flowmeter—Regular (Threaded, Pak-Lok), SST page 265
PBR+25/26S ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST page 267
PBR+35/36S ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST page 270
PBR+45/46S ProBar® + Flowmeter—Regular (Threaded, Pak-Lok), SST page 273
PBF+15/16S ProBar® + Flowmeter—Flanged, SST page 281
PBF+25/26S ProBar® + Flowmeter—Flanged, SST page 284
PBF+25/26H ProBar® + Flowmeter—Flanged, Hastelloy–C page 287
PBF+25/26M ProBar® + Flowmeter—Flanged, Monel page 290
PBF+35/36S ProBar® + Flowmeter—Flanged, SST page 293
PBF+45/46S ProBar® + Flowmeter—Flanged, SST page 296
PBF+45/46H ProBar® + Flowmeter—Flanged, Hastelloy–C page 299
PBF+45/46M ProBar® + Flowmeter—Flanged, Monel page 302

ProBar®
Line Sizes—2 in. and larger
PNT+10S ProBar® + Flowmeter—In-Line Threaded, SST page 310
PNF+10S ProBar® + Flowmeter—In-Line Flanged, SST page 312
®
PNF+10H ProBar + Flowmeter—In-Line Flanged, Hastelloy-C page 314
PNF+10M ProBar® + Flowmeter—In-Line Flanged, Monel page 316
PNW+10S ProBar® + Flowmeter—In-Line Butt Weld, SST page 318
Line Sizes—½ in. to 2 in.
PHT+15S ProBar® + Flowmeter—Threaded Flo-Tap, SST page 325
PHT+25S ProBar® + Flowmeter—Threaded Flo-Tap, SST page 328
PHT+35S ProBar® + Flowmeter—Threaded Flo-Tap, SST page 331
PHF+15S ProBar® + Flowmeter—Flanged Flo-Tap, SST page 340
®
PHF+25S ProBar + Flowmeter—Flanged Flo-Tap, SST page 343
PHF+25M ProBar® + Flowmeter—Flanged Flo-Tap, Monel page 349
PHF+35S ProBar® + Flowmeter—Flanged Flo-Tap, SST page 352
PHF+45S ProBar® + Flowmeter—Flanged Flo-Tap, SST page 355
PHF+45H ProBar® + Flowmeter—Flanged Flo-Tap, Hastelloy-C page 358
PHF+45M ProBar® + Flowmeter—Flanged Flo-Tap, Monel page 361

Flow-263
ProBar® Flowmeter

5. VERIFY PROCESS AND PIPE INFORMATION


Configuration Information
When ordering a ProBar, it is important to include all of the flowing conditions and pipe information for your
application. This will ensure that you receive the correct product for your application. Please see the ProBar
Configuration Data Sheet 00806–0100–4761.

Dimension Codes
Certain dimensions are critical to the fabrication of the primary flow element assembly. The following codes
can be specified in the model callout “string” and Dieterich Standard, Inc. will build the primary flow element
assembly to suit. If no dimension is specified, cataloged components will default to standard dimensions.

ODH ODV

ODH is the outside diameter of the pipe to the top of ODV is the outside diameter of the pipe to the top of
the ProBar head (Figure 25). If this dimension is the isolation valve (Figure 27). ODV applies to
specified for a flanged, Flo–Tap, or Regular model, Flo–Tap models only, and only when the customer
ProBar®

the neck of the primary flow element just below supplies some or all of the mounting hardware.
standard dimension can be considered a minimum.
This dimension does not apply to in–line sensors or
to Model 45S.

ODV

ODH

FIGURE 27. ODV.


NL

NL is the nipple length for DNW, DNF, and DNT-10


FIGURE 25. ODH.
in-line models (Figure 28). Additional length can be
ODF specified to fit specific piping configurations. The
extra length will be applied upstream of the sensor
ODF is the outside diameter of the pipe to the face unless otherwise specified.
of the mounting flange (Figure 26). This dimension
applies only to DFF, DHF, DSF, NFF, SPF, SFF,
and SSF models. If Dieterich Standard, Inc. is not
supplying the mounting hardware, this dimension
must be specified. If Dieterich Standard, Inc.
is providing the mounting flange assembly, note
the following:

• The standard ODF is a minimum.


FIGURE 28. NL.
• The extensions must be at least 2 inches CMH
longer than the minimum ODF.
CMH is the customer mount height distance from
the outside of the pipe to the top of the appropriately
sized NPT threaded female mounting coupling
ODF
(Figure 29). Supply these values for Regular and
Flo–Tap models that are being installed in a
customer’s mounting or saddle.
FIGURE 26. ODF.
CMH

FIGURE 29. CMH.


Flow-264
Rosemount Inc.

Ordering Information—Model PBR


MODEL PBR+15S/16S
Model Product Description
PBR+15S ProBar® + Flowmeter - Regular
PBR+16S ProBar® + Flowmeter - Regular with Opposite SIde Support

Code Line Size


020 2 in. (50 mm)
025 21/2 in. (63.5 mm)
030 3 in. (80 mm)
035 31/2 in. (89 mm)
040 4 in. (100 mm)
050 5 in. (125 mm)

Code Head Style

Remote Mount - Horizontal Line


HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST

ProBar®
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
CA2SS Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
CP2SS Needle valve, Nipple,1/2 in. Socket Weld Port, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Gate Valve - CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
1
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, /2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow,1/2 in. Socket Weld Port, SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple,1/2 in. Socket Weld Port, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT,SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in. Socket Weld Port, SST

Code Mounting Hardware


MP2C0 Pak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, CS
MP2S0 Pak-Lok, with Contoured Weld Fitting, 1/2—14 NPT, SST
MR2C0 Pak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, CS
MR2S0 Pak-Lok, No Contoured Weld Fitting, 1/2—14 NPT, SST

Code DP Ranges

0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)


1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4–20 mA with Digital Signal based on HART

Code Fill Fluid

1 Silicone
2 Inert Fill

Flow-265
ProBar® Flowmeter

MODEL PBR+15S/16S
Code Housing Material
A Epoxy-Poly-Aluminum 1/2—14 NPT
B Epoxy-Poly-Aluminum CM20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G1/2

Code Opposite Side Support (Required for Model 16S ONLY)


MS2C0 Contoured Weld Fitting and Plug, 1/2—14 NPT, CS
MS2CW Contoured Weld Fitting and Plug, 1/2 in. Socket Weld Port, CS
MS2S0 Contoured Weld Fitting and Plug, 1/2—14 NPT, SST
MS2SW Contoured Weld Fitting and Plug, 1/2 in. Socket Weld Port, SST

Code Optional Auxiliary Mounting (Mounting Alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT2C Contoured Weld Fitting, 1/2—14 NPT, CS
MT2S Contoured Weld Fitting, 1/2—14 NPT, SST
ME2C Weld Coupling, 1/2—14 NPT, CS
ME2A Weld Coupling, 1/2—14 NPT, Aluminum
ME2K Weld Coupling, 1/2—14 NPT, Copper
ProBar®

ME2P Weld Coupling, 1/2—14 NPT, PVC


ME2S Weld Coupling, 1/2—14 NPT, SST
NB20 Saddle, Double Strap, 2.35-2.56, 1/2—14 NPT, Iron
NC20 Saddle, Double Strap, 2.41-2.91,1/2—14 NPT, Iron
ND20 Saddle, Double Strap, 2.97-3.54,1/2—14 NPT, Iron
NE20 Saddle, Double Strap, 4.14-4.80,1/2—14 NPT, Iron
NF20 Saddle, Double Strap, 5.94-6.70,1/2—14 NPT, Iron

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate) - Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


L Multipoint Flow Calibration (ID <= 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PBR+15S 020 HA2S0 CA2C0 MP2C0 1 A 1 A

Flow-266
Rosemount Inc.
MODEL PBR+25S/26S
Model Product Description

PBR+25S ProBar® + Flowmeter - Regular


PBR+26S ProBar® + Flowmeter - Regular with Opposite Side Support

Code Line Size


040 4 in. (100 mm)
050 5 in. (125 mm)
060 6 in. (150 mm)
080 8 in. (200 mm)
100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line

ProBar®
HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, with 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATS0 Integral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HATSB Direct Mount, with 5-Valve Manifold, RTD,B31.1, Horizontal Line, SST
HATSD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HATSN Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, with 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, with 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVTSB Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
HVTSD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line,1/2—14 NPT, SST
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line,1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line,1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valves - CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee,1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
CA2SS Needle Valve, Elbow, ½ in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple,1/2—14 NPT, SST
CP2SS Needle valve, Nipple,1/2 in. Socket Weld Port, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Gate Valve - CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

Flow-267
ProBar® Flowmeter

MODEL PBR+25S/26S
Code Instrument Connections (Continued)
Gate Valve - SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2in. Socket Weld Port, SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2in. Socket Weld Port, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT,SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2—14 NPT,SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST

Code Mounting Hardware


MR4C0 Pak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, CS
MR4S0 Pak-Lok, No Contoured Weld Fitting, 1—11.5 NPT, SST
MP4C0 Pak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, CS
MP4S0 Pak-Lok, with Contoured Weld Fitting, 1—11.5 NPT, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)
ProBar®

Code Output
A 4–20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material

A Epoxy-Poly-Aluminum 1/2—14 NPT


B Epoxy-Poly-Aluminum CM20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G1/2

Code Opposite Side Support (Required for Model 26S ONLY)


MS4C0 Contoured Weld Fitting and Plug, 1—11.5 NPT, CS
MS4CW Contoured Weld Fitting and Plug, 1in. Socket Weld Port, CS
MS4S0 Contoured Weld Fitting and Plug, 1—11.5 NPT, SST
MS4SW Contoured Weld Fitting and Plug, 1in. Socket Weld Port, SST

Code Optional Auxiliary Mounting (Mounting Alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT4C Contoured Weld Fitting, 1—11.5 NPT, CS
MT4S Contoured Weld Fitting, 1—11.5 NPT, SST
ME4C Weld Coupling, 1—11.5 NPT, CS
ME4A Weld Coupling, 1—11.5 NPT, Aluminum
ME4K Weld Coupling, 1—11.5 NPT, Copper
ME4P Weld Coupling, 1—11.5 NPT, PVC
ME4S Weld Coupling, 1—11.5 NPT, SST
NE40 Saddle, Double Strap, 3.74-4.55OD, 1—11.5 NPT, Iron
NF40 Saddle, Double Strap, 5.94-6.7in.OD,1—11.5 NPT, Iron
NG40 Saddle, Double Strap, 8.54-10.1OD,1—11.5 NPT, Iron
NH40 Saddle, Double Strap, 10.64-12.12,1—11.5 NPT, Iron
NJ40 Saddle, Double Strap, 12.6-14.3OD,1—11.5 NPT, Iron

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2in. Pipe/Panel, SST Bolts

Flow-268
Rosemount Inc.

MODEL PBR+25S/26S
Code Optional Meters
1 LCD Meter (Rate) - Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


L Multipoint Flow Calibration (ID ≤ 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)

ProBar®
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PBR+25S 040 HAMS0 C0000 MP4C0 1 A 1 A

Flow-269
ProBar® Flowmeter

MODEL PBR+35S/36S
Model Product Description
PBR+35S ProBar® + Flowmeter - Regular
PBR+36S ProBar® + Flowmeter - Regular with Opposite Side Support

Code Line Size

080 8 in. (200 mm)


100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style

Direct and Integral Mount Heads - Horizontal Line


ProBar®

HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST


HADSB Direct Mount, with 5-Valve Manifold, B31.1,Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, with 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATS0 Integral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HATSB Direct Mount, with 5-Valve Manifold, RTD,B31.1, Horizontal Line, SST
HATSD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HATSN Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, with 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, with 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVTS0 Integral, with 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
HVTSD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line,1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
CA2SS Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
CP2SS Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Gate Valve - CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS

Flow-270
Rosemount Inc.

MODEL PBR+35S/36S
Code Instrument Connections (Continued)
Gate Valve - SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam,1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST

Code Mounting Hardware


MP6C0 Pak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, CS
MP6S0 Pak-Lok, with Contoured Weld Fitting, 11/2—11.5 NPT, SST
MR6C0 Pak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, CS
MR6S0 Pak-Lok, No Contoured Weld Fitting, 11/2—11.5 NPT, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

ProBar®
Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material

A Epoxy-Poly-Aluminum 1/2-14
B Epoxy-Poly-Aluminum CM20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G1/2

Code Opposite Side Support (Required for Model 36S ONLY)


MS6C0 Contoured Weld Fitting and Plug, 1 1/2—11.5 NPT, CS
MS6CW Contoured Weld Fitting and Plug, 1 1/2 in. Socket Weld Port, CS
MS6S0 Contoured Weld Fitting and Plug, 1 1/2—11.5 NPT, SST
MS6SW Contoured Weld Fitting and Plug, 1 1/2 in. Socket Weld Port, SST

Code Optional Auxiliary Mounting (Mounting alternatives for use when Contoured Weld Fitting is Not Specified in Mounting Hardware)
MT6C Contoured Weld Fitting,11/2—11.5 NPT, CS
MT6S Contoured Weld Fitting,11/2—11.5 NPT, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate) - Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Flow-271
ProBar® Flowmeter

MODEL PBR+35S/36S
Code Optional Hazardous Location Certificates
I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration

L Multipoint Flow Calibration (ID ≤ 10 in.)


M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
ProBar®

Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1 Dieterich Program


Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PBR+35S 120 HAMS0 C0000 MP6C0 1 A 1 A

Flow-272
Rosemount Inc.

MODEL PBR+45S/46S
Model Product Descriptions
PBR+45S ProBar® + Flowmeter-Regular
PBR+46S ProBar® + Flowmeter-Regular with Opposite Side Support

Code Line Size

100 10 in. (250 mm)


120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style

Direct and Integral Mount Heads - Horizontal Line


HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST

ProBar®
HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, with 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATS0 Integral, with 3-Valve Manifold, RTD, Horizontal Line, SST
HATSB Direct Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, SST
HATSD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HATSN Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSN Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, with 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
HVTSB Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVTS0 Integral, with 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
HVTSD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
HP2SS Parallel, Horizontal Line,1/2 in. Socket Weld Port, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line,1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
CP2SS Needle Valve, Nipple, 1/2 in. Socket Weld Port, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT,SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT,SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST

Flow-273
ProBar® Flowmeter

MODEL PBR+45S/46S
Code Mounting Hardware
MPDC0 Pak-Lok, with Contoured Weld Fitting, 3—11.5 NPT, CS
MPDS0 Pak-Lok, with Contoured Weld Fitting, 3—11.5 NPT, SST

Code DP Ranges

0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)


1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output

A 4–20 mA with Digital Signal based on HART

Code Fill Fluid

1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum 1/2—14 NPT
ProBar®

B Epoxy-Poly-Aluminum CM20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G1/2

Code Opposite Side Support (Required for Model 46S ONLY)


MSDCW Contoured Weld Fitting and Cap, 3 in. BW, CS
MSDSW Contoured Weld Fitting and Cap, 3 in. BW, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Code Optional Manifolds

3 Model 305 Manifold Bolted to Transmitter


5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in. Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate) - Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates

I5 FM Intrinsic Safety Approval


C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Flow-274
Rosemount Inc.

MODEL PBR+45S/46S
Code Optional Calibration
L Multipoint Flow Calibration (ID ≤ 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing

ProBar®
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PBR+45S 240 HAMS0 C0000 MPDC0 1 A 1 A

Flow-275
ProBar® Flowmeter
ProBar®

276
Flow-276
Rosemount Inc.

ProBar®

Flow-277
ProBar® Flowmeter
ProBar®

278
Flow-278
Rosemount Inc.

ProBar®

Flow-279
ProBar® Flowmeter
ProBar®

280
Flow-280
Rosemount Inc.

Ordering Information—Model PBF


MODEL PBF+15S/16S
Model Product Description
PBF+15S ProBar® + Flowmeter - Flanged
PBF+16S ProBar® + Flowmeter - Flanged with Opposite Side Support

Code Line Size


020 2 in. (50 mm)
025 21/2 in. (63.5 mm)
030 3 in. (80 mm)
035 31/2 in. (89 mm)
040 4 in. (100 mm)
050 5 in. (125 mm)

Code Head Style

Direct and Integral Mount Heads - Horizontal Line


HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST

ProBar®
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
Remote Mount - Horizontal Line
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in., Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
HP2SS Parallel, Horizontal Line, 1/2 in., Socket Weld Port, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in., Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in., Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, 1/2 in., Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
CP2SS Needle Valve, Nipple, 1/2 in., Socket Weld Port, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in., Socket Weld Port, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in., Socket Weld Port, SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in., Socket Weld Port, SST
SC2S0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2 in., Socket Weld Port, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Sensor Flange


FNMS0 DIN 25 PN 100, 316 SST
FLMS0 DIN 25 PN 40, 316 SST
FJMS0 DIN 25 PN 16, 316 SST
FC4S0 1 in. ANSI Class 600, RF, SST
FB4S0 1 in. ANSI Class 300, RF, SST
FA4S0 1 in. ANSI Class 150, RF, SST

Flow-281
ProBar® Flowmeter

MODEL PBF+15S/16S
Code Flanged Mount
FA4C 1 in. ANSI Class 150, Weld-Neck RF, CS
FA4S 1 in. ANSI Class 150, Weld-Neck RF, SST
FB4C 1 in. ANSI Class 300, Weld-Neck RF, CS
FB4S 1 in. ANSI Class 300, Weld-Neck RF, SST
FC4C 1 in. ANSI Class 600, Weld-Neck RF, CS
FC4S 1 in. ANSI Class 600, Weld-Neck RF, SST
FJMC DIN 25 PN 16, CS
FJMS DIN 25 PN 16, 316 SST
FLMC DIN 25 PN 40, CS
FLMS DIN 25 PN 40, 316 SST
FNMC DIN 25 PN 100, CS
FNMS DIN 25 PN 100, 316 SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output

A 4–20 mA with Digital Signal based on HART


ProBar®

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum 1/2—14 NPT
B Epoxy-Poly-Aluminum CM20
C Epoxy-Poly-Aluminum PG13.5

Code Housing Material


D Epoxy-Poly-Aluminum G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Aluminum G1/2

Code Opposite Side Support (Required for Model 16S ONLY)


MS2C0 Contoured Weld Fitting and Plug, 1/2—14 NPT, CS
MS2CW Contoured Weld Fitting and Plug, 1/2 in., Socket Weld Port, CS
MS2S0 Contoured Weld Fitting and Plug, 1/2—14 NPT, SST
MS2SW Contoured Weld Fitting and Plug, 1/2 in., Socket Weld Port, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion–Proof

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST
1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters

1 LCD Meter (Rate)- Aluminum Housing


2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion–Proof and Intrinsic Safety Approval
E5 FM Explosion–Proof Approval
K5 FM Explosion–Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion–Proof Approval

Code Optional Calibration

L Multipoint Flow Calibration (ID ≤ 10 in.)


M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration

Flow-282
Rosemount Inc.

MODEL PBF+15S/16S
Code Optional Quality Assurance
QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QM8 EN 10204 3.1B Material Certs
QT1 Hydrostatic Test EP-4017
QT8 Extended Hydro EP-4046
Typical Model Number PBF+15S 020 HAMS0 C0000 FA4S0 FA4C 1 A 1 A

ProBar®

Flow-283
ProBar® Flowmeter

MODEL PBF+25S/26S
Model Product Description
PBF+25S ProBar® + Flowmeter - Flanged
PBF+26S ProBar® + Flowmeter - Flanged with Opposite Side Support

Code Line Size

040 4 in. (100 mm)


050 5 in. (125 mm)
060 6 in. (150 mm)
080 8 in. (200 mm)
100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)

Code Head Style

Direct and Integral Mount Heads


ProBar®

HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST


HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
HAXS0 Direct Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATS0 Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
HATSB Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SST
HATSD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HATSN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
HVTSD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in., Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line,1/2—14 NPT, SST
HP2SS Parallel, Horizontal Line, 1/2 in., Socket Weld Port, SST
HPVS0 Parallel, Vertical Line,1/2 in., Socket Weld Port, SST
HPVSS Parallel, Vertical Line,1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in., Socket Weld Port, SST

Code Instrument Connections

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple,1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee,1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2— 14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, 1/2 in., Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
CP2SS Needle Valve, Nipple, 1/2 in., Socket Weld Port, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in., Socket Weld Port, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS

Flow-284
Rosemount Inc.

MODEL PBF+25S/26S
Code Instrument Connections (Continued)
Gate Valve - SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in., Socket Weld Port, SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in., Socket Weld Port, SST
SC2S0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in., Socket Weld Port, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Sensor Flange


FNPS0 DIN 40 PN 100, 316 SST
FLPS0 DIN 40 PN 40, 316 SST
FJPS0 DIN 40 PN 16, 316 SST
FC6S0 11/2 in. ANSI Class 600, RF, SST
FB6S0 11/2 in. ANSI Class 300, RF, SST
FA6S0 11/2 in. ANSI Class 150, RF, SST

Code Flanged Mount

FA6C 11/2 in. ANSI Class 150, Weld-Neck RF, CS


FA6S 11/2 in. ANSI Class 150, Weld-Neck RF, SST

ProBar®
FB6C 11/2 in. ANSI Class 300, Weld-Neck RF, CS
FB6S 11/2 in. ANSI Class 300, Weld-Neck RF, SST
FC6C 11/2 in. ANSI Class 600, Weld-Neck RF, CS
FC6S 11/2 in. ANSI Class 600, Weld-Neck RF, SST
FJPC DIN 40 PN 16, CS
FJPS DIN 40 PN 16, 316 SST
FLPC DIN 40 PN 40, CS
FLPS DIN 40 PN 40, 316 SST
FNPC DIN 40 PN 100, CS
FNPS DIN 40 PN 100, 316 SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material

A Epoxy-Poly-Aluminum 1/2—14 NPT


B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G1/2

Code Opposite Side Support (Required for Model 26S ONLY)


MS4C0 Contoured Weld Fitting and Plug, 1—11.5 NPT, CS
MS4CW Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, CS
MS4S0 Contoured Weld Fitting and Plug, 1—11.5 NPT, SST
MS4SW Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion–Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion–Proof, Axial
TXP Integral RTD, Explosion–Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Flow-285
ProBar® Flowmeter

MODEL PBF+25S/26S
Code Optional Mounting Brackets
K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters

1 LCD Meter (Rate)- Aluminum Housing


2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion–Proof and Intrinsic Safety Approval
E5 FM Explosion–Proof Approval
K5 FM Explosion–Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion–Proof Approval

Code Optional Calibration

L Multipoint Flow Calibration (ID ≤ 10 in.)


M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
ProBar®

N Multipoint Flow Calibration (12 in.)


P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1 Dieterich Program


Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QM8 EN 10204 3.1B Material Certs
QT1 Hydrostatic Test EP-4017
QT8 Extended Hydro EP-4046
Typical Model Number PBF+25S 040 HAMS0 C0000 FA6S0 FA6C 1 A 1 A

Flow-286
Rosemount Inc.

MODEL PBF+25H/26H
Code Product Description
PBF+25H ProBar® + Flowmeter - Flanged
PBF+26H ProBar® + Flowmeter - Flanged with Opposite Side Support

Code Line Size

040 4 in. (100 mm)


050 5 in. (125 mm)
060 6 in. (150 mm)
080 8 in. (200 mm)
100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)

Code Head Style

Direct and Integral Mount Heads - Horizontal Line

ProBar®
HADH0 Direct Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-C
HADHB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-C
HADHN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C
HAMH0 Integral, with 3-Valve Manifold, Horizontal Line, Hastelloy-C
HAPH0 Direct Mount, No Manifold, Horizontal Line, Hastelloy-C
Direct and Integral Mount Heads - Horizontal Line with RTD
HATH0 Integral, with 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
HATHB Direct Mount, with 5-Valve Manifold, RTD, B31.1, Horizontal Line, Hastelloy-C
HATHD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
HATHN Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C
Direct and Integral Mount Heads - Vertical Line
HVDH0 Direct Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-C
HVDHB Direct Mount, with 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-C
HVDHN Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C
HVMH0 Integral, with 3-Valve Manifold, Vertical Line, Hastelloy-C
HVPH0 Direct Mount, No Manifold, Vertical Line, Hastelloy-C
Direct and Integral Mount Heads - Vertical Line with RTD
HVTH0 Integral, with 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C
HVTHB Direct Mount, with 5-Valve Manifold, RTD, B31.1, Vertical Line, Hastelloy-C
HVTHD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C
HVTHN Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C
Remote Mount - Horizontal Line
HA2H0 Axial, Horizontal Line, 1/2—14 NPT, Hastelloy-C
HA2HS Axial, Horizontal Line, 1/2 in., Socket Weld Port, Hastelloy-C
HP2H0 Parallel, Horizontal Line,1/2—14 NPT, Hastelloy-C
Remote Mount - Vertical Line
HPVH0 Parallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.
HV2H0 Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve - Hastelloy
CA2H0 Needle Valve, Elbow, 1/2—14 NPT, Hastelloy-C
CP2H0 Needle Valve, Nipple, 1/2—14 NPT, Hastelloy-C
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 11/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate, Vertical Line, Nipple and Tee, 1/2—14 NPT,CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT,CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS

Flow-287
ProBar® Flowmeter

MODEL PBF+25H/26H
Code Instrument Connections (Continued)
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee,1/2—14 NPT, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Sensor Flange

FC6H0 11/2 in. ANSI Class 600, RF, Hastelloy-C


FB6H0 11/2 in. ANSI Class 300, RF, Hastelloy-C
FA6H0 11/2 in. ANSI Class 150, RF, Hastelloy-C

Code Flanged Mount


FA6C 11/2 in. ANSI Class 150, Weld-Neck RF, CS
FA6S 11/2 in. ANSI Class 150, Weld-Neck RF, SST
FB6C 11/2 in. ANSI Class 300, Weld-Neck RF, CS
FB6S 11/2 in. ANSI Class 300, Weld-Neck RF, SST
FC6C 11/2 in. ANSI Class 600, Weld-Neck RF, CS
FC6S 11/2 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges
ProBar®

1 0 -.5 to 0 - 25 inH20 (0-.12 to 0-6.22 kPa)


2 0 - 2.5 to 0 - 250 inH20 (0 -.62 to 0 - 62.2 kPa)
3 0 - 10 to 0 - 830 inH20 (0 - 2.48 to 0 - 206 kPa)

Code Output
A 4— 20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum 1/2—14 NPT
B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G1/2

Code Opposite Side Support (Required for Model 26H ONLY)

MS4CW Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, CS
MS4S0 Contoured Weld Fitting and Plug, 1—11.5 NPT, SST
MS4SW Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion–Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion–Proof, Axial
TXP Integral RTD, Explosion–Proof, Parallel

Code Optional Manifolds

3 Model 305 Manifold Bolted to Transmitter


5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets

K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Flow-288
Rosemount Inc.

MODEL PBF+25H/26H
Code Optional Hazardous Location Certificates
I5 FM Intrinsic Safety Approval
C6 CSA Explosion–Proof and Intrinsic Safety Approval
E5 FM Explosion–Proof Approval
K5 FM Explosion–Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion–Proof Approval

Code Optional Calibration

L Multipoint Flow Calibration (ID ≤ 10 in.)


M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)

ProBar®
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance

QA1 Dieterich Program


Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046
Typical Model Number PBF+25H 040 HAMH0 C0000 FA6H0 FA6C 1 A 1 A

Flow-289
ProBar® Flowmeter

MODEL PBF+25M/26M
Model Product Description
PBF+25M ProBar® + Flowmeter - Flanged
PBF+26M ProBar® + Flowmeter - Flanged with Opposite Side Support

Code Line Size

040 4 in. (100 mm)


050 5 in. (125 mm)
060 6 in. (150 mm)
080 8 in. (200 mm)
100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line
ProBar®

HADM0 Direct Mount, with 5-Valve Manifold, Horizontal Line, Monel


HADMB Direct Mount, with 5-Valve Manifold, B31.1,Horizontal Line, Monel
HADMN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Monel
HAMM0 Integral, 3-Valve Manifold, Horizontal Line, Monel
HAPM0 Direct Mount, No Manifold, Horizontal Line, Monel
Direct and Integral Mount Heads - Horizontal Line with RTD
HATM0 Integral, 3-Valve Manifold, RTD, Horizontal Line, Monel
HATMB Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Monel
HATMD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, Monel
HATMN Direct Mount,5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
Direct and Integral Mount Heads - Vertical Line
HVDM0 Direct Mount, with5-Valve Manifold, Vertical Line, Monel
HVDMB Direct Mount, 5-Valve Manifold, B31.1,Vertical Line, Monel
HVDMN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
HVMM0 Integral, 3-Valve Manifold, Vertical Line, Monel
HVPM0 Direct Mount, No Manifold, Vertical Line, Monel
Direct and Integral Mount Heads - Vertical Line with RTD
HVTM0 Integral, 3-Valve Manifold, RTD, Vertical Line, Monel
HVTMB Direct Mount, 5-Valve Manifold, RTD,B31.1,Vertical Line, Monel
HVTMD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, Monel
HVTMN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
Remote Mount - Horizontal Line
HA2M0 Axial, Horizontal Line, 1/2—14 NPT, Monel
HA2MS Axial, Horizontal Line, ½ in., Socket Weld Port, Monel
HP2M0 Parallel, Horizontal Line, 1/2—14 NPT, Monel
Remote Mount - Vertical Line
HPVM0 Parallel, Vertical Line, 1/2—14 NPT, Monel
HV2M0 Axial, Vertical Line, 1/2—14 NPT, Monel
HV2MS Axial, Vertical Line, ½ in., Socket Weld Port, Monel

Code Instrument Connections

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve - Monel
CP2M0 Needle Valve, Nipple, 1/2—14 NPT, Monel
CA2M0 Needle Valve, Elbow, 1/2—14 NPT, Monel
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Yoke, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS

Flow-290
Rosemount Inc.

MODEL PBF+25M/26M
Code Instrument Connections (Continued)
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam,1 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, /2—14 NPT, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Sensor Flange


FC6M0 1½ in. ANSI Class 600, RF, Monel
FB6M0 1½ in. ANSI Class 300, RF, Monel
FA6M0 1½ in. ANSI Class 150, RF, Monel

Code Flanged Mount


FA6C 1½ in. ANSI Class 150, Weld-Neck RF, CS
FA6S 1½ in. ANSI Class 150, Weld-Neck RF, SST
FB6C 1½ in. ANSI Class 300, Weld-Neck RF, CS
FB6S 1½ in. ANSI Class 300, Weld-Neck RF, SST
FC6C 1½ in. ANSI Class 600, Weld-Neck RF, CS
FC6S 1½ in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges

ProBar®
1 0 -.5 to 0 - 25 inH20 (0 -.12 to 0 - 6.22 kPa)
2 0 - 2.5 to 0 - 250 inH20 (0 -.62 to 0 - 62.2kPa)
3 0 - 10 to 0 - 830 inH20 (0 - 2.48 to 0 - 206kPa)

Code Output

A 4–20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G½
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Code Opposite Side Support (Required for Model 26M ONLY)

MS4CW Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, CS
MS4S0 Contoured Weld Fitting and Plug, 1—11.5 NPT, SST
MS4SW Contoured Weld Fitting and Plug, 1 in., Socket Weld Port, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion–Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion–Proof, Axial
TXP Integral RTD, Explosion–Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters

1 LCD Meter (Rate)- Aluminum Housing


2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Flow-291
ProBar® Flowmeter

MODEL PBF+25M/26M
Code Optional Hazardous Location Certificates
I5 FM Intrinsic Safety Approval
C6 CSA Explosion–Proof and Intrinsic Safety Approval
E5 FM Explosion–Proof Approval
K5 FM Explosion–Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion–Proof Approval

Code Optional Calibration


L Multipoint Flow Calibration (ID ≤ 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)
ProBar®

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material - Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046
Typical Model Number PBF+25M 040 HAMM0 C0000 FA6M0 FA6C 1 A 1 A

Flow-292
Rosemount Inc.

MODEL PBF+35S/36S
Model Product Description
PBF+35S ProBar® + Flowmeter - Flanged
PBF+36S ProBar® + Flowmeter - Flanged with Opposite Side Support

Code Line Size

080 8 in. (200 mm)


100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style

Direct and Integral Mount Heads - Horizontal Line

ProBar®
HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
HAXS0 Direct Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line With RTD
HATS0 Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
HATSB Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SST
HATSD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HATSN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line With RTD
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
HVTSD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HP2SS Parallel, Horizontal Line, ½ in., Socket Weld Port, SST
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, ½ in., Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, ½ in., Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, ½ in., Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, ½ in., Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CP2SS Needle Valve, Nipple, ½ in., Socket Weld Port, SST
SP2SS Needle Valve, Nipple and Tee, ½ in., Socket Weld Port, SST
Gate Valve - CS
SC2C0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS

Flow-293
ProBar® Flowmeter

MODEL PBF+35S/36S
Code Instrument Connections (Continued)
Gate Valve - SST
SC2S0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, ½ in., Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, ½ in., Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in., Socket Weld Port, SST

Code Sensor Flanges


FNRS0 DIN 50 PN 100, 316 SST
FLRS0 DIN 50 PN 40, 316 SST
FJRS0 DIN 50 PN 16, 316 SST
FC8S0 2 in. ANSI Class 600, RF, SST
FB8S0 2 in. ANSI Class 300, RF, SST
FA8S0 2 in. ANSI Class 150, RF, SST

Code Flanged Mount


FA8C 2 in. ANSI Class 150, Weld-Neck RF, CS
FA8S 2 in. ANSI Class 150, Weld-Neck RF, SST
FB8C 2 in. ANSI Class 300, Weld-Neck RF, CS
ProBar®

FB8S 2 in. ANSI Class 300, Weld-Neck RF, SST


FC8C 2 in. ANSI Class 600, Weld-Neck RF, CS
FC8S 2 in. ANSI Class 600, Weld-Neck RF, SST
FJRC DIN 50 PN 16, CS
FJRS DIN 50 PN 16, 316 SST
FLRC DIN 50 PN 40, CS
FLRS DIN 50 PN 40, 316 SST
FNRC DIN 50 PN 100, CS
FNRS DIN 50 PN 100, 316 SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output

A 4–20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Code Opposite Side Support (Required for Model 36S ONLY)


MS6C0 Contoured Weld Fitting and Plug, 1½—11.5 NPT, CS
MS6CW Contoured Weld Fitting and Plug, 1½ in., Socket Weld Port, CS
MS6S0 Contoured Weld Fitting and Plug, 1½—11.5 NPT, SST
MS6SW Contoured Weld Fitting and Plug, 1½ in., Socket Weld Port, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion–Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion–Proof, Axial
TXP Integral RTD, Explosion–Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST
1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Flow-294
Rosemount Inc.

MODEL PBF+35S/36S
Code Optional Meters
1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion–Proof and Intrinsic Safety Approval
E5 FM Explosion–Proof Approval
K5 FM Explosion–Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion–Proof Approval

Code Optional Calibration


L Multipoint Flow Calibration (ID ≤ 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)

ProBar®
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046
Typical Model Number PBF+35S 120 HAMS0 C0000 FA8S0 FA8C 1 A 1 A

Flow-295
ProBar® Flowmeter

MODEL PBF+45S/46S
Model Product Description
PBF+45S ProBar® + Flowmeter - Flanged
PBF+46S ProBar® + Flowmeter - Flanged with Opposite Side Support

Code Line Size


100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line
ProBar®

HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST


HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
HAXS0 Direct Mount, Quantity Two, 3-Valve Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line With RTD
HATS0 Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
HATSB Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, SST
HATSD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, SST
HATSN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line With RTD
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, SST
HVTSD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HP2SS Parallel, Horizontal Line, ½ in., Socket Weld Port, SST
HA2S0 Axial, Horizontal Line, ½ in.—14 NPT, SST
HA2SS Axial, Horizontal Line, ½ in., Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line,½ in.—14 NPT, SST
HSHS0 Stack Head with Purge, Horizontal Line, ½ in.—14 NPT, SST
HPVS0 Parallel, Vertical Line, ½ in., Socket Weld Port, SST
HPVSS Parallel, Vertical Line, ½ —14 NPT, SST
HV2S0 Axial, Vertical Line, ½—14 NPT, SST
HV2SS Axial, Vertical Line, ½ in., Socket Weld Port, SST
HSVS0 Stack Head with Purge, Vertical Line, ½—14 NPT, SST

Code Instrument Connections

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, ½—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, ½—14 NPT, CS
CA2SS Needle Valve - SST
CP2S0 Needle Valve, Elbow, ½ in., Socket Weld Port, SST
SP2S0 Needle Valve, Nipple, ½—14 NPT, SST
CP2SS Needle Valve, Nipple and Tee, ½—14 NPT, SST
SP2SS Needle Valve, Nipple, ½ in., Socket Weld Port, SST
Needle Valve, Nipple and Tee, ½ in., Socket Weld Port, SST
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, ½—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS

Flow-296
Rosemount Inc.

MODEL PBF+45S/46S
Code Instrument Connections (Continued)
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, ½ in., Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, ½ in., Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½ in., Socket Weld Port, SST

Code Sensor Flanges


FBDS0 3 in. ANSI Class 300, RF, SST
FNTS0 DIN 80 PN 100, 316 SST
FLTS0 DIN 80 PN 40, 316 SST
FJTS0 DIN 80 PN 16, 316 SST
FCDS0 3 in. ANSI Class 600, RF, SST
FADS0 3 in. ANSI Class 150, RF, SST

Code Flanged Mount

FADC 3 in. ANSI Class 150, Weld-Neck RF, CS


FADS 3 in. ANSI Class 150, Weld-Neck RF, SST
FBDC 3 in. ANSI Class 300, Weld-Neck RF, CS

ProBar®
FBDS 3 in. ANSI Class 300, Weld-Neck RF, SST
FCDC 3 in. ANSI Class 600, Weld-Neck RF, CS
FCDS 3 in. ANSI Class 600, Weld-Neck RF, SST
FJTC DIN 80 PN 16, CS
FJTS DIN 80 PN 16, 316 SST
FLTC DIN 80 PN 40, CS
FLTS DIN 80 PN 40, 316 SST
FNTC DIN 80 PN 100, CS
FNTS DIN 80 PN 100, 316 SST

Code DP Ranges

0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)


1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid

1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Code Opposite Side Support (Required for Model 46S ONLY)


MSDCW Contoured Weld Fitting and Cap, 3 in., BW, CS
MSDSW Contoured Weld Fitting and Cap, 3 in., BW, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion–Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion–Proof, Axial
TXP Integral RTD, Explosion–Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Flow-297
ProBar® Flowmeter

MODEL PBF+45S/46S
Code Optional Meters
1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion–Proof and Intrinsic Safety Approval
E5 FM Explosion–Proof Approval
K5 FM Explosion–Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion–Proof Approval

Code Optional Calibration

L Multipoint Flow Calibration (ID ≤ 10 in.)


M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
ProBar®

R Multipoint Flow Calibration (18 in. to 20 in.)


S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046
Typical Model Number PBF+45S 240 HAMS0 C0000 FADS0 FADC 1 A 1 A

Flow-298
Rosemount Inc.

MODEL PBF+45H/46H
Model Product Description
PBF+45H ProBar® + Flowmeter - Flanged
PBF+46H ProBar® + Flowmeter - Flanged with Opposite Side Support

Code Line Size

100 10 in. (250 mm)


120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style

Direct and Integral Mount Heads - Horizontal Line


HADH0 Direct Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-C

ProBar®
HADHB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-C
HADHN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C
HAMH0 Integral, with 3-Valve Manifold, Horizontal Line, Hastelloy-C
HAPH0 Direct Mount, No Manifold, Horizontal Line, Hastelloy-C
Direct and Integral Mount Heads - Horizontal Line With RTD
HATH0 Integral, with 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
HATHB Direct Mount, with 5-Valve Manifold,RTD,B31.1, Horizontal Line, Hastelloy-C
HATHD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C
HATHN Direct Mount, with 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C
Direct and Integral Mount Heads - Vertical Line
HVDH0 Direct Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-C
HVDHB Direct Mount, with 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-C
HVDHN Direct Mount, with 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C
HVMH0 Integral, with 3-Valve Manifold, Vertical Line, Hastelloy-C
HVPH0 Direct Mount, No Manifold, Vertical Line, Hastelloy-C
Direct and Integral Mount Heads - Vertical Line With RTD
HVTH0 Integral, with 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C
HVTHB Direct Mount, with 5-Valve Manifold, RTD, B31.1,Vertical Line, Hastelloy-C
HVTHD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C
HVTHN Direct Mount, with 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C
Remote Mount - Horizontal Line
HA2H0 Axial, Horizontal Line, ½—14 NPT, Hastelloy-C
HA2HS Axial, Horizontal Line, ½ in., Socket Weld Port, Hastelloy-C
HP2H0 Parallel, Horizontal Line, ½—14 NPT, Hastelloy-C
Remote Mount - Vertical Line
HPVH0 Parallel, Vertical Line, ½—14 NPT, Hastelloy-C.
HV2H0 Axial, Vertical Line, ½—14 NPT, Hastelloy-C.
HSVH0 Stack head with purge, Vertical Line, ½—14 NPT, Hastelloy-C

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, ½—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, ½—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, ½—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, ½—14 NPT, SST
Needle Valve - Hastelloy
CP2H0 Needle Valve, Nipple, ½—14 NPT, Hastelloy-C
CC2C0 Gate Valve - CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, ½—14 NPT½—14 NPT, CS
Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST

Code Sensor Flanges


FCDH0 3 in. ANSI Class 600, RF, Hastelloy-C
FBDH0 3 in. ANSI Class 300, RF, Hastelloy-C
FADH0 3 in. ANSI Class 150, RF, Hastelloy-C

Flow-299
ProBar® Flowmeter

MODEL PBF+45H/46H
Code Flanged Mount
FADC 3 in. ANSI Class 150, Weld-Neck RF, CS
FADS 3 in. ANSI Class 150, Weld-Neck RF, SST
FBDC 3 in. ANSI Class 300, Weld-Neck RF, CS
FBDS 3 in. ANSI Class 300, Weld-Neck RF, SST
FCDC 3 in. ANSI Class 600, Weld-Neck RF, CS
FCDS 3 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges

1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)


2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid

1 Silicone
2 Inert Fill
ProBar®

Code Housing Material


A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Code Opposite Side Support (Required for Model 46H ONLY)

MSDCW Contoured Weld Fitting and Cap, 3 in., BW, CS


MSDSW Contoured Weld Fitting and Cap, 3 in., BW, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion–Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion–Proof, Axial
TXP Integral RTD, Explosion–Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets

K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate) - Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion–Proof and Intrinsic Safety Approval
E5 FM Explosion–Proof Approval
K5 FM Explosion–Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion–Proof Approval

Flow-300
Rosemount Inc.

MODEL PBF+45H/46H
Code Optional Calibration
L Multipoint Flow Calibration (ID ≤ 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing

ProBar®
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046
Typical Model Number PBF+45H 240 HAMH0 C0000 FADH0 FADC 1 A 1 A

Flow-301
ProBar® Flowmeter

MODEL PBF+45M/46M
Model Product Description
PBF+45M ProBar® + Flowmeter - Flanged
PBF+46M ProBar® + Flowmeter - Flanged with Opposite Side Support

Code Line Size

100 10 in. (250 mm)


120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style

Direct and Integral Mount Heads - Horizontal Line


HADM0 Direct Mount, with 5-Valve Manifold, Horizontal Line, Monel
ProBar®

HADMB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Monel
HADMN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Monel
HAMM0 Integral, 3-Valve Manifold, Horizontal Line, Monel
HAPM0 Direct Mount, No Manifold, Horizontal Line, Monel
Direct and Integral Mount Heads - Horizontal Line
HATM0 Integral, 3-Valve Manifold, RTD, Horizontal Line, Monel
HATMB Direct Mount, 5-Valve Manifold, RTD, B31.1, Horizontal Line, Monel
HATMD Direct Mount, with 5-Valve Manifold, RTD, Horizontal Line, Monel
HATMN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
Direct and Integral Mount Heads - Vertical Line
HVDM0 Direct Mount, with 5-Valve Manifold, Vertical Line, Monel
HVDMB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, Monel
HVDMN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
HVMM0 Integral, 3-Valve Manifold, Vertical Line, Monel
HVPM0 Direct Mount, No Manifold, Vertical Line, Monel
Direct and Integral Mount Heads - Vertical Line with RTD
HVTM0 Integral, 3-Valve Manifold, RTD, Vertical Line, Monel
HVTMB Direct Mount, 5-Valve Manifold, RTD, B31.1, Vertical Line, Monel
HVTMD Direct Mount, with 5-Valve Manifold, RTD, Vertical Line, Monel
HVTMN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
Remote Mount - Horizontal Line
HA2M0 Axial, Horizontal Line, ½—14 NPT, Monel
HA2MS Axial, Horizontal Line, ½ in., Socket Weld Port, Monel
HP2M0 Parallel, Horizontal Line, ½—14 NPT, Monel
Remote Mount - Vertical Line
HPVM0 Parallel, Vertical Line, ½—14 NPT, Monel
HV2M0 Axial, Vertical Line, ½—14 NPT, Monel
HV2MS Axial, Vertical Line, ½ in., Socket Weld Port, Monel
HSVM0 Stack Head with Purge, Vertical Line, ½—14 NPT, Monel

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, ½—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, ½—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, ½—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, ½—14 NPT, SST
Needle Valve - Monel
CP2M0 Needle Valve, Nipple, ½—14 NPT, Monel
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate, Vertical Line, Nipple and Tee, ½—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, ½—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate, Vertical Line, Nipple and Tee, Steam, ½—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, ½—14 NPT, SST

Code Sensor Flanges


FCDM0 3 in. ANSI Class 600, RF, Monel
FBDM0 3 in. ANSI Class 300, RF, Monel
FADM0 3 in. ANSI Class 150, RF, Monel

Flow-302
Rosemount Inc.

MODEL PBF+45M/46M
Code Flanged Mount
FADC 3 in. ANSI Class 150, Weld-Neck RF, CS
FADS 3 in. ANSI Class 150, Weld-Neck RF, SST
FBDC 3 in. ANSI Class 300, Weld-Neck RF, CS
FBDS 3 in. ANSI Class 300, Weld-Neck RF, SST
FCDC 3 in. ANSI Class 600, Weld-Neck RF, CS
FCDS 3 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges

1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)


2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid

1 Silicone
2 Inert Fill

ProBar®
Code Housing Material
A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Code Opposite Side Support (Required for Model 46M ONLY)

MSDCW Contoured Weld Fitting and Cap, 3 in., BW, CS


MSDSW Contoured Weld Fitting and Cap, 3 in., BW, SST

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion–Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion–Proof, Axial
TXP Integral RTD, Explosion–Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets

K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion–Proof and Intrinsic Safety Approval
E5 FM Explosion–Proof Approval
K5 FM Explosion–Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion–Proof Approval

Flow-303
ProBar® Flowmeter

MODEL PBF+45M/46M
Code Optional Calibration
L Multipoint Flow Calibration (ID ≤ 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in. to 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in. to 16 in.)
R Multipoint Flow Calibration (18 in. to 20 in.)
S Lab Flow Calibration (Average K) (18 in. to 20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA2 Certified Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
ProBar®

QM2 ASTM Material-Traceable (Sensor Only)


QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046
Typical Model Number PBF+45M 240 HAMM0 C0000 FADM0 FADC 1 A 1 A

Flow-304
Rosemount Inc.

ProBar®

Flow-305
ProBar® Flowmeter
ProBar®

306
Flow-306
Rosemount Inc.

ProBar®

Flow-307
ProBar® Flowmeter
ProBar®

308
Flow-308
Rosemount Inc.

ProBar®

Flow-309
ProBar® Flowmeter

Ordering Information—Model PNT


MODEL PNT+10S
Model Product Description
PNT+10S ProBar® + Flowmeter - In-line Threaded

Code Line Size

005 ½ in. (12.5 mm)


007 ¾ in. (19 mm)
010 1 in. (25 mm)
012 1¼ in. (31 mm)
015 1½ in. (37.5 mm)
020 2 in. (50 mm)

Code Fittings
Direct and Integral Mount Heads - Horizontal Line
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
Ordering

HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Remote Mount
HF1SS Fittings, ¼ in. Socket Weld Ports, SST
HM1S0 Fittings, ¼—18 NPT, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP1C0 Needle Valve, Nipple, ¼—18 NPT, CS
SP1C0 Needle Valve, Nipple and Tee, ¼—18 NPT, CS
Needle Valve - SST
CP1S0 Needle Valve, Nipple, ¼—18 NPT, SST
SP1S0 Needle Valve, Nipple and Tee, ¼—18 NPT, SST
SB1C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
SB1S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal Based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG 13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Flow-310
Rosemount Inc.

MODEL PNT+10S
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets


1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters

1 LCD Meter (Rate) - Aluminum Housing


2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

ProBar®
Code Optional Hazardous Location Certificates
I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Certificate
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Quality Assurance

QA1 Dieterich Program


Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PNT+10S 010 HAMS0 C0000 1 A 1 A

Flow-311
ProBar® Flowmeter

Ordering Information—Model PNF


MODEL PNF+10S
Model Product Description
PNF+10S ProBar® + Flowmeter - In-line Flanged

Code Line Size


005 ½ in. (12.5 mm)
007 ¾ in. (19 mm)
010 1 in. (25 mm)
012 1¼ in. (31 mm)
015 1½ in. (37.5 mm)
020 2 in. (50 mm)

Code Fittings
Direct and Integral Mount Heads - Horizontal Line
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
ProBar®

Direct and Integral Mount Heads - Vertical Line


HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Remote Mount
HF1SS Fittings, ¼ in. Socket Weld Ports, SST
HM1S0 Fittings, ¼—18 NPT, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP1C0 Needle Valve, Nipple, ¼—18 NPT, CS
SP1C0 Needle Valve, Nipple and Tee, ¼—18 NPT, CS
Needle Valve - SST
CP1S0 Needle Valve, Nipple, ¼—18 NPT, SST
SP1S0 Needle Valve, Nipple and Tee, ¼—18 NPT, SST
Gate Valve
SB1C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
SB1S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST

Code Flanged Mount


FAS ANSI Class 150, Weld-Neck RF, SST
FBS ANSI Class 300, Weld-Neck RF, SST
FCS ANSI Class 600, Weld-Neck RF, SST
FJS DIN PN 16, SST
FLS DIN PN 40, SST
FNS DIN PN 100, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output

A 4–20 mA with Digital Signal Based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Flow-312
Rosemount Inc.

MODEL PNF+10S
Code Housing Material
A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG 13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion-Proof

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

ProBar®
Code Optional Mounting Brackets

1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate) - Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Certificate
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PNF+10S 010 HAMS0 C0000 FAS 1 A 1 A

Flow-313
ProBar® Flowmeter

MODEL PNF+10H
Model Product Description
PNF+10H ProBar® + Flowmeter - In-line Flanged

Code Line Size

005 ½ in. (12.5 mm)


007 ¾ in. (19 mm)
010 1 in. (25 mm)
012 1¼ in. (31 mm)
015 1½ in. (37.5 mm)
020 2 in. (50 mm)

Code Fittings
Direct and Integral Mount Heads - Horizontal Line
HADH0 Direct Mount, with 5-Valve Manifold, Horizontal Line, Hastelloy-C
HADHN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C
HAMH0 Integral, 3-Valve Manifold, Horizontal Line, Hastelloy-C
HAPH0 Direct Mount, No Manifold, Horizontal Line, Hastelloy-C
HADHB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Hastelloy-C
Direct and Integral Mount Heads - Vertical Line
HVDH0 Direct Mount, with 5-Valve Manifold, Vertical Line, Hastelloy-C
ProBar®

HVDHN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C


HVMH0 Integral, 3-Valve Manifold, Vertical Line, Hastelloy-C
HVPH0 Direct Mount, No Manifold, Vertical Line, Hastelloy-C
HVDHB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, Hastelloy-C
Remote Mount
HM1H0 Fittings, ¼—18 NPT, Hastelloy-C

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP1C0 Needle Valve, Nipple, ¼—18 NPT, CS
SP1C0 Needle Valve, Nipple and Tee, ¼—18 NPT, CS
Needle Valve - SST
CP1S0 Needle Valve, Nipple, ¼—18 NPT, SST
SP1S0 Needle Valve, Nipple and Tee, ¼—18 NPT, SST
Gate Valve
SB1C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
SB1S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST

Code Flanged Mount


FAH ANSI Class 150, Weld-Neck RF, Hastelloy-C
FBH ANSI Class 300, Weld-Neck RF, Hastelloy-C
FCH ANSI Class 600, Weld-Neck RF, Hastelloy-C

Code DP Ranges
1 0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 in H2O (0-.62 to 0-62.2 kPa)
3 0-10 to 0-830 in H2O (0-2.48 to 0-206 kPa)

Code Output
A 4–20 mA with Digital Signal Based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG 13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion-Proof

Flow-314
Rosemount Inc.

MODEL PNF+10H
Code Optional Manifolds
3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets


1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate) - Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval

ProBar®
ID KEMA/CENELEC Intrinsic Safety Certificate
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PNF+10H 010 HAMH0 C0000 FAH 1 A 1 A

Flow-315
ProBar® Flowmeter

MODEL PNF+10M
Model Product Description
PNF+10M ProBar® + Flowmeter - In-line Flanged

Code Line Size

005 ½ in. (12.5 mm)


007 ¾ in. (19 mm)
010 1 in. (25 mm)
012 1¼ in. (31 mm)
015 1½ in. (37.5 mm)
020 2 in. (50 mm)

Code Fittings
Direct and Integral Mount Heads - Horizontal Line
HADMN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, Monel
HADM0 Direct Mount, with 5-Valve Manifold, Horizontal Line, Monel
HADMB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, Monel
HAMM0 Integral, 3-Valve Manifold, Horizontal Line, Monel
HAPM0 Direct Mount, No Manifold, Horizontal Line, Monel
ProBar®

Direct and Integral Mount Heads - Vertical Line


HVDMN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
HVDM0 Direct Mount, with 5-Valve Manifold, Vertical Line, Monel
HVDMB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, Monel
HVMM0 Integral, 3-Valve Manifold, Vertical Line, Monel
HVPM0 Direct Mount, No Manifold, Vertical Line, Monel
Remote Mount
HM1M0 Fittings, ¼—18 NPT, Monel

Code Instrument Connections

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP1C0 Needle Valve, Nipple, ¼—18 NPT, CS
SP1C0 Needle Valve, Nipple and Tee, ¼—18 NPT, CS
Needle Valve - SST
CP1S0 Needle Valve, Nipple, ¼—18 NPT, SST
SP1S0 Needle Valve, Nipple and Tee, ¼—18 NPT, SST
Gate Valve
SB1C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
SB1S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST

Code Flanged Mount


FAM ANSI Class 150, Weld-Neck RF, Monel
FBM ANSI Class 300, Weld-Neck RF, Monel
FCM ANSI Class 600, Weld-Neck RF, Monel

Code DP Ranges
1 0-.5 to 0-25 in H2O (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 in H2O (0-.62 to 0-62.2 kPa)
3 0-10 to 0-830 in H2O (0-2.48 to 0-206 kPa)

Code Output
A 4–20 mA with Digital Signal Based on HART

Code Fill Fluid

1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG 13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Flow-316
Rosemount Inc.

MODEL PNF+10M
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets


1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters

1 LCD Meter (Rate) - Aluminum Housing


2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

ProBar®
Code Optional Hazardous Location Certificates
I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Certificate
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Quality Assurance

QA1 Dieterich Program


Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PNF+10M 010 HAMM0 C0000 FAM 1 A 1 A

Flow-317
ProBar® Flowmeter

Ordering Information—Model PNW


MODEL PNW+10S
Model Product Description
PNW+10S ProBar® + Flowmeter - In-line Butt Weld

Code Line Size


005 ½ in. (12.5 mm)
007 ¾ in. (19 mm)
010 1 in. (25 mm)
012 1¼ in. (31 mm)
015 1½ in. (37.5 mm)
020 2 in. (50 mm)

Code Fittings

Direct and Integral Mount Heads - Horizontal Line


HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HADS0 Direct Mount, with 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, with 5-Valve Manifold, B31.1, Horizontal Line, SST
HADSN Direct Mount, with 5-Valve Manifold, NACE, Horizontal Line, SST
ProBar®

HAPS0 Direct Mount, No Manifold, Horizontal Line, SST


Direct and Integral Mount Heads - Vertical Line
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVDS0 Direct Mount, with 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Remote Mount
HF1SS Fittings, ¼ in. Socket Weld Ports, SST
HM1S0 Fittings, ¼—18 NPT, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP1C0 Needle Valve, Nipple, ¼—18 NPT, CS
SP1C0 Needle Valve, Nipple and Tee, ¼—18 NPT, CS
Needle Valve - SST
CP1S0 Needle Valve, Nipple, ¼—18 NPT, SST
SP1S0 Needle Valve, Nipple and Tee, ¼—18 NPT, SST
Gate Valve
SB1C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, CS
SB1S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, ¼—18 NPT, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4–20 mA with Digital Signal Based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly-Aluminum ½—14 NPT
B Epoxy-Poly-Aluminum CM 20
C Epoxy-Poly-Aluminum PG 13.5
D Epoxy-Poly-Aluminum G½
J 316 SST ½—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly-Aluminum G½

Flow-318
Rosemount Inc.

MODEL PNW+10S
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5-Valve Manifold, CS
6 5-Valve Manifold, SST
7 3-Valve Manifold, CS
8 3-Valve Manifold, SST

Code Optional Mounting Brackets


1 Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate) - Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

ProBar®
Code Optional Hazardous Location Certificates
I5 FM Intrinsic Safety Approval
C6 CSA Explosion Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Certificate
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Quality Assurance

QA1 Dieterich Program


Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number PNW+10S 010 HAMS0 C0000 1 A 1 A

Flow-319
ProBar® Flowmeter
ProBar®

320
Flow-320
Rosemount Inc.

ProBar®

Flow-321
ProBar® Flowmeter
ProBar®

322
Flow-322
Rosemount Inc.

ProBar®

Flow-323
ProBar® Flowmeter
ProBar®

324
Flow-324
Rosemount Inc.

Ordering Information—Model PHT


MODEL PHT+15S
Model Product Description
PHT+15S ProBar® + Flowmeter - Threaded Flo-Tap

Code Line Size


020 2 in. (50 mm)
025 21/2 in. (63.5 mm)
030 3 in. (80 mm)
035 31/2 in. (89 mm)
040 4 in. (100 mm)
050 5 in. (125 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HADS0 Direct Mount, 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
HADSN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST

ProBar®
Direct and Integral Mount Heads - Vertical Line
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVDS0 Direct Mount, 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Remote Mount - Horizontal Line
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2SS Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Packing Gland


GV3S0 Graphite, 3/4—14 NPT, SST
GV3C0 Graphite, 3/4—14 NPT, CS
GH3S0 Urethane, 3/4—14 NPT, SST
GH3C0 Urethane, 3/4—14 NPT, CS

Flow-325
ProBar® Flowmeter

MODEL PHT+15S
Code Insert/Retract

IHRS Manual, Dual, SST Rods


IHRC Manual, Dual, CS Rods

Code Isolation Valve


Gate Valve
VT3SG Gate Valve, 3/4—14 NPT, SST
VT3CG Gate Valve, 3/4—14 NPT, CS
Ball Valve
VT3SB Ball Valve, 3/4—14 NPT, SST
VT3CB Ball Valve, 3/4—14 NPT, CS

Code Mounting Hardware


MH3C0 Weld Coupling and Nipple, 3/4—14 NPT, CS
MH3S0 Weld Coupling and Nipple, 3/4—14 NPT, SST

Code DP Ranges

0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)


1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
ProBar®

2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)


3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output

A 4—20 mA with Digital Signal based on HART

Code Fill Fluid

1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly.-Alum. 1/2—14 NPT
B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof

Code Optional Manifolds

3 Model 305 Manifold Bolted to Transmitter


5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


L Multipoint Flow Calibration (ID ≤ 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration

Flow-326
Rosemount Inc.

MODEL PHT+15S
Code Optional Quality Assurance

QA1 Dieterich Program


Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHT+15S 020 HAMS0 C0000 GV3S0 IHRC VT3CG MH3C0 2 A 1 A

ProBar®

Flow-327
ProBar® Flowmeter

MODEL PHT+25S
Model Product Description
PHT+25S ProBar® + Flowmeter - Threaded Flo-Tap

Code Line Size

040 4 in. (100 mm)


050 5 in. (125 mm)
060 6 in. (150 mm)
080 8 in. (200 mm)
100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)

Code Head Style


ProBar®

Direct and Integral Mount Heads - Horizontal Line


HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HADS0 Direct Mount, 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
HADSN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATSN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HATS0 Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
HATSD Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
HATSB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVDS0 Direct Mount, 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
HVTSD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2SS Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST

Flow-328
Rosemount Inc.

MODEL PHT+25S
Code Instrument Connections (Continued)
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Packing Gland


GV5S0 Graphite, 11/4—11.5 NPT, SST
GV5C0 Graphite, 11/4—11.5 NPT, CS
GH5S0 Urethane, 11/4—11.5 NPT, SST

ProBar®
GH5C0 Urethane, 11/4—11.5 NPT, CS

Code Insert/Retract
IHRS Manual, Dual, SST Rods
IHRC Manual, Dual, CS Rods
IHDS Gear, Dual, SST Rods

Code Isolation Valve


Gate Valve
VT5SG Gate Valve, 11/4—11.5 NPT, SST
VT5CG Gate Valve, 11/4—11.5 NPT, CS
Ball Valve
VT5SB Ball Valve, 11/4—11.5 NPT, SST
VT5CB Ball Valve, 11/4—11.5 NPT, CS

Code Mounting Hardware


MH5C0 Weld Coupling and Nipple, 11/4—11.5 NPT, CS
MH5S0 Weld Coupling and Nipple, 11/4—11.5 NPT, SST

Code DP Ranges

0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)


1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output

A 4—20 mA with Digital Signal based on HART

Code Fill Fluid

1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly.-Alum. 1/2—14 NPT
B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Flow-329
ProBar® Flowmeter

MODEL PHT+25S
Code Optional Manifolds
3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST
9 Special Manifold

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
ProBar®

E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHT+25S 040 HAMS0 C0000 GV5SO IHRC VT5CG MH5C0 2 A 1 A

Flow-330
Rosemount Inc.

MODEL PHT+35S
Model Product Description
PHT+35S ProBar® + Flowmeter - Threaded Flo-Tap

Code Line Size

100 10 in. (250 mm)


120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
340 34 in. (864 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. (1520 mm)
720 72 in. (1820 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line

ProBar®
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HADS0 Direct Mount, 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
HADSN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATSN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HATS0 Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
HATSD Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
HATSB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVDS0 Direct Mount, 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
HVTSD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2SS Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST

Flow-331
ProBar® Flowmeter

MODEL PHT+35S
Code Instrument Connections (Continued)
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Packing Gland


GV8S0 Graphite, 2—11.5 NPT, SST
GV8C0 Graphite, 2—11.5 NPT, CS
GH8S0 Urethane, 2—11.5 NPT, SST
ProBar®

GH8C0 Urethane, 2—11.5 NPT, CS

Code Insert/Retract
IHRS Manual, Dual, SST Rods
IHRC Manual, Dual, CS Rods
I990 Special Insert/Retract Assembly
IHDS Gear, Dual, SST Rods

Code Isolation Valves

Gate Valve
VT8SG Gate Valve, 2—11.5 NPT, SST
VT8CG Gate Valve, 2—11.5 NPT, CS
Ball Valve
VT8SB Ball Valve, 2—11.5 NPT, SST
VT8CB Ball Valve, 2—11.5 NPT, CS

Code Mounting Hardware


MH8C0 Weld Coupling and Nipple, 2—11.5 NPT, CS
MH8S0 Weld Coupling and Nipple, 2—11.5 NPT, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material

A Epoxy-Poly.-Alum. 1/2—14 NPT


B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Flow-332
Rosemount Inc.

MODEL PHT+35S
Code Optional Manifolds
3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval

ProBar®
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHT+35S 120 HAMS0 C0000 GV8C0 IHDS VT8CG MH8C0 2 A 1 A

Flow-333
ProBar® Flowmeter
ProBar®

334
Flow-334
Rosemount Inc.

ProBar®

Flow-335
ProBar® Flowmeter
ProBar®

336
Flow-336
Rosemount Inc.

ProBar®

Flow-337
ProBar® Flowmeter
ProBar®

338
Flow-338
Rosemount Inc.

ProBar®

Flow-339
ProBar® Flowmeter

Ordering Information—Model PHF


MODEL PHF+15S
Model Product Description
PHF+15S ProBar® + Flowmeter - Flanged Flo-Tap

Code Line Size


020 2 in. (50 mm)
025 21/2 in. (63.5 mm)
030 3 in. (80 mm)
035 31/2 in. (89 mm)
040 4 in. (100 mm)
050 5 in. (125 mm)

Code Head Style


Direct and Integral Head Mount - Horizontal Line
HADS0 Direct Mount, 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
HADSN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
ProBar®

Direct and Integral Head Mount - Vertical Line


HVDS0 Direct Mount, 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Remote Mount - Horizontal Line
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections)


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2SS Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Flow-340
Rosemount Inc.

MODEL PHF+15S
Code Packing Gland
GV4SC Graphite, 1 in. ANSI Class 600, SST
GV4SB Graphite, 1 in. ANSI Class 300, SST
GV4SA Graphite, 1 in. ANSI Class 150, SST
GH4SC Urethane, 1 in. ANSI Class 600, SST
GH4SB Urethane, 1 in. ANSI Class 300, SST
GH4SA Urethane, 1 in. ANSI Class 150, SST

Code Insert/Retract
IHRS Manual, Dual, SST Rods
IHRC Manual, Dual, CS Rods

Code Isolation Valve


Gate Valve
VC4SG Gate Valve, 1 in. ANSI Class 600, SST
VC4CG Gate Valve, 1 in. ANSI Class 600, CS
VB4SG Gate Valve, 1 in. ANSI Class 300, SST
VB4CG Gate Valve, 1 in. ANSI Class 300, CS
VA4SG Gate Valve, 1 in. ANSI Class 150, SST
VA4CG Gate Valve, 1 in. ANSI Class 150, CS

ProBar®
Ball Valve
VB4SB Ball Valve, 1 in. ANSI Class 300, SST
VB4CB Ball Valve, 1 in. ANSI Class 300, CS
VA4SB Ball Valve, 1 in. ANSI Class 150, SST
VA4CB Ball Valve, 1 in. ANSI Class 150, CS
Other
FA4C 1 in. ANSI Class 150, Weld-Neck RF, CS
FA4S 1 in. ANSI Class 150, Weld-Neck RF, SST
FB4C 1 in. ANSI Class 300, Weld-Neck RF, CS
FB4S 1 in. ANSI Class 300, Weld-Neck RF, SST
FC4C 1 in. ANSI Class 600, Weld-Neck RF, CS
FC4S 1 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output

A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material

A Epoxy-Poly.-Alum. 1/2—14 NPT


B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof

Code Optional Manifolds

3 Model 305 Manifold Bolted to Transmitter


5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST
9 Special Manifold

Code Optional Mounting Brackets

K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Flow-341
ProBar® Flowmeter

MODEL PHF+15S
Code Optional Meters
1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


L Multipoint Flow Calibration (ID ≤ 10 in.)
M Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration

Code Optional Quality Assurance


ProBar®

QA1 Dieterich Program


Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHF+15S 020 HAMS0 C0000 GV4SA IHRS VA4CG 1 A 1 A

Flow-342
Rosemount Inc.

MODEL PHF+25S
Model Product Description
PHF+25S ProBar® + Flowmeter - Flanged Flo-Tap

Code Line Size

040 4 in. (100 mm)


050 5 in. (125 mm)
060 5 in. (150 mm)
080 8 in. (200 mm)
100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line

ProBar®
HADS0 Direct Mount, 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
HADSN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATSN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HATS0 Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
HATSD Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
HVTSD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CP2SS Needle Valve, Nipple, 1/2 in. Socket Weld Port, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS

Flow-343
ProBar® Flowmeter

MODEL PHF+25S
Code Instrument Connections (Continued)
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST

Code Packing Gland

GV8SC Graphite, 2 in. ANSI Class 600


GV8SB Graphite, 2 in. ANSI Class 300
GV8SA Graphite, 2 in. ANSI Class 150
GH8SC Urethane, 2 in. ANSI Class 600, SST
GH8SB Urethane, 2 in. ANSI Class 300, SST
GH8SA Urethane, 2 in. ANSI Class 150, SST

Code Insert/Retract
IHRS Manual, Dual, SST Rods
ProBar®

IHRC Manual, Dual, CS Rods


IHDS Gear, Dual, SST Rods
IHDC Gear, Dual, CS Rods

Code Isolation Valve


Gate Valve
VB8SG Gate Valve, 2 in. ANSI Class 300, SST
VB8CG Gate Valve, 2 in. ANSI Class 300, CS
VA8SG Gate Valve, 2 in. ANSI Class 150, SST
VA8CG Gate Valve, 2 in. ANSI Class 150, CS
Ball Valve
VB8SB Ball Valve, 2 in. ANSI Class 300, SST
VB8CB Ball Valve, 2 in. ANSI Class 300, CS
VA8SB Ball Valve, 2 in. ANSI Class 150, SST
VA8CB Ball Valve, 2 in. ANSI Class 150, CS

Code Flanged Mount

FA8C 2 in. ANSI Class 150, Weld-Neck RF, CS


FA8S 2 in. ANSI Class 150, Weld-Neck RF, SST
FB8C 2 in. ANSI Class 300, Weld-Neck RF, CS
FB8S 2 in. ANSI Class 300, Weld-Neck RF, SST
FC8C 2 in. ANSI Class 600, Weld-Neck RF, CS
FC8S 2 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material

A Epoxy-Poly.-Alum. 1/2—14 NPT


B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Flow-344
Rosemount Inc.

MODEL PHF+25S
Code Optional Manifolds
3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST
9 Special Manifold

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval

ProBar®
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHF+25S 080 HADSO C0000 GV8SA IHRC VA8SG FA87C 2 A 1 A

Flow-345
ProBar® Flowmeter

MODEL PHF+25H
Model Product Description
PHF+25H ProBar® + Flowmeter - Flanged Flo-Tap

Code Line Size

040 4 in. (100 mm)


050 5 in. (125 mm)
060 6 in. (150 mm)
080 8 in. (200 mm)
100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line
ProBar®

HADH0 Direct Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.


HADHB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Hastelloy-C.
HADHN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C.
HAMH0 Integral, 3-Valve Manifold, Horizontal Line, Hastelloy-C.
HAPH0 Direct Mount, No Manifold, Horizontal Line, Hastelloy-C.
Direct and Integral Mount Heads - Horizontal Line with RTD
HATH0 Integral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.
HATHB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Hastelloy-C.
HATHD Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.
HATHN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C.
Direct and Integral Mount Heads - Vertical Line
HVDH0 Direct Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.
HVDHB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Hastelloy-C.
HVDHN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C.
HVMH0 Integral, 3-Valve Manifold, Vertical Line, Hastelloy-C.
HVPH0 Direct Mount, No Manifold, Vertical Line, Hastelloy-C.
Direct and Integral Mount Heads - Vertical Line with RTD
HVTH0 Integral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C.
HVTHB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Hastelloy-C.
HVTHD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C.
HVTHN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C.
Remote Mount - Horizontal Line
HA2H0 Axial, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
HA2HS Axial, Horizontal Line, 1/2 in. Socket Weld Port, Hastelloy-C.
HP2H0 Parallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
Remote Mount - Horizontal Line
HPVH0 Parallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.
HV2H0 Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve - Hastelloy
CA2H0 Needle Valve, Elbow, 1/2—14 NPT, Hastelloy-C.
CP2H0 Needle Valve, Nipple, 1/2—14 NPT, Hastelloy-C.
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS

Flow-346
Rosemount Inc.

MODEL PHF+25H
Code Instrument Connections (Continued)
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Packing Gland


GV6HC Graphite, 11/2 in.ANSI Class 600, Hastelloy-C.
GV6HB Graphite, 11/2 in.ANSI Class 300, Hastelloy-C.
GV6HA Graphite, 11/2 in.ANSI Class 150, Hastelloy-C.

Code Insert/Retract

IHRS Manual, Dual, SST Rods


IHRC Manual, Dual, CS Rods
IHDS Gear, Dual, SST Rods
IHDC Gear, Dual, CS Rods

Code Isolation Valve

ProBar®
Gate Valve
VC6SG Gate Valve, 11/2 in. ANSI Class 600, SST
VC6CG Gate Valve, 11/2 in. ANSI Class 600, CS
VB6SG Gate Valve, 11/2 in. ANSI Class 300, SST
VB6CG Gate Valve, 11/2 in. ANSI Class 300, CS
VA6SG Gate Valve, 11/2 in. ANSI Class 150, SST
VA6CG Gate Valve, 11/2 in. ANSI Class 150, CS
Ball Valve
VB6SB Ball Valve, 11/2 in. ANSI Class 300, SST
VB6CB Ball Valve, 11/2 in. ANSI Class 300, CS
VA6SB Ball Valve, 11/2 in. ANSI Class 150, SST
VA6CB Ball Valve, 11/2 in. ANSI Class 150, CS

Code Flanged Mount


FA6C 11/2 in. ANSI Class 150, Weld-Neck RF, CS
FA6S 11/2 in. ANSI Class 150, Weld-Neck RF, SST
FB6C 11/2 in. ANSI Class 300, Weld-Neck RF, CS
FB6S 11/2 in. ANSI Class 300, Weld-Neck RF, SST
FC6C 11/2 in. ANSI Class 600, Weld-Neck RF, CS
FC6S 11/2 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges

1 0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)


2 0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)
3 0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)

Code Output

A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material

A Epoxy-Poly.-Alum. 1/2—14 NPT


B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Flow-347
ProBar® Flowmeter

MODEL PHF+25H
Code Optional Manifolds
3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
ProBar®

K5 FM Explosion-Proof and Intrinsic Safety Approval


ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHF+25H 040 HAMH0 C0000 GV6HA IHRC VA6CG FA6C 1 A 1 A

Flow-348
Rosemount Inc.

MODEL PHF+25M
Model Product Description
PHF+25M ProBar® + Flowmeter - Flanged Flo-Tap

Code Line Size

040 4 in. (100 mm)


050 5 in. (125 mm)
060 6 in. (150 mm)
080 8 in. (200 mm)
100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line

ProBar®
HADH0 Direct Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.
HADM0 Direct Mount, 5-Valve Manifold, Horizontal Line, Monel
HADMB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Monel
HADMN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Monel
HAMM0 Integral, 3-Valve Manifold, Horizontal Line, Monel
HAPM0 Direct Mount, No Manifold, Horizontal Line, Monel
Direct and Integral Mount Heads - Horizontal Line with RTD
HATM0 Integral, 3-Valve Manifold, RTD, Horizontal Line, Monel
HATMB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Monel
HATMD Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Monel
HATMN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
Direct and Integral Mount Heads - Vertical Line
HVDH0 Direct Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.
HVDM0 Direct Mount, 5-Valve Manifold, Vertical Line, Monel
HVDMB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Monel
HVDMN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
HVMM0 Integral, 3-Valve Manifold, Vertical Line, Monel
HVPM0 Direct Mount, No Manifold, Vertical Line, Monel
Direct and Integral Mount Heads - Vertical Line with RTD
HVTM0 Integral, 3-Valve Manifold, RTD, Vertical Line, Monel
HVTMB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Monel
HVTMD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Monel
HVTMN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
Remote Mount - Horizontal Line
HA2M0 Axial, Horizontal Line, 1/2—14 NPT, Monel
HA2MS Axial, Horizontal Line, 1/2 in. Socket Weld Port, Monel
HP2M0 Parallel, Horizontal Line, 1/2—14 NPT, Monel
Remote Mount - Vertical Line
HPVM0 Parallel, Vertical Line, 1/2—14 NPT, Monel
HV2M0 Axial, Vertical Line, 1/2—14 NPT, Monel
HV2MS Axial, Vertical Line, 1/2 in. Socket Weld Port, Monel

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
Needle Valve - Monel
CP2M0 Needle Valve, Nipple, 1/2—14 NPT, Monel
CA2M0 Needle Valve, Elbow, 1/2—14 NPT, Monel

Flow-349
ProBar® Flowmeter

MODEL PHF+25M
Code Instrument Connections (Continued)
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST

Code Packing Gland


GV6MC Graphite, 11/2 in. ANSI Class 600, Monel
GV6MB Graphite, 11/2 in. ANSI Class 300, Monel
GV6MA Graphite, 11/2 in. ANSI Class 150, Monel

Code Insert/Retract
ProBar®

IHRS Manual, Dual, SST Rods


IHRC Manual, Dual, CS Rods
IHDS Gear, Dual, SST Rods
IHDC Gear, Dual, CS Rods

Code Isolation Valve


Gate Valve
VC6SG Gate Valve, 11/2 in. ANSI Class 600, SST
VC6CG Gate Valve, 11/2 in. ANSI Class 600, CS
VB6SG Gate Valve, 11/2 in. ANSI Class 300, SST
VB6CG Gate Valve, 11/2 in. ANSI Class 300, CS
VA6SG Gate Valve, 11/2 in. ANSI Class 150, SST
VA6CG Gate Valve, 11/2 in. ANSI Class 150, CS
Ball Valve
VB6SB Ball Valve, 11/2 in. ANSI Class 300, SST
VB6CB Ball Valve, 11/2 in. ANSI Class 300, CS
VA6SB Ball Valve, 11/2 in. ANSI Class 150, SST
VA6CB Ball Valve, 11/2 in. ANSI Class 150, CS

Code Flanged Mount


FA6C 11/2 in. ANSI Class 150, Weld-Neck RF, CS
FA6S 11/2 in. ANSI Class 150, Weld-Neck RF, SST
FB6C 11/2 in. ANSI Class 300, Weld-Neck RF, CS
FB6S 11/2 in. ANSI Class 300, Weld-Neck RF, SST
FC6C 11/2 in. ANSI Class 600, Weld-Neck RF, CS
FC6S 11/2 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges
1 0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)
2 0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)
3 0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly.-Alum. 1/2—14 NPT
B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Flow-350
Rosemount Inc.

MODEL PHF+25M
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing

ProBar®
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHF+25M 040 HAMM0 C0000 GV6MA IHRC VA6CG FA6C 1 A 1 A

Flow-351
ProBar® Flowmeter

MODEL PHF+35S
Model Product Description
PHF+35S ProBar® + Flowmeter - Flanged Flo-Tap

Code Line Size

080 8 in. (200 mm)


100 10 in. (250 mm)
120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style


ProBar®

Direct and Integral Mount Heads - Horizontal Line


HADS0 Direct Mount, 5-Valve Manifold, Horizontal Line, SST
HADSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
HADSN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATSN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HATS0 Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
HATSD Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDS0 Direct Mount, 5-Valve Manifold, Vertical Line, SST
HVDSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
HVTSD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST
Remote Mount - Horizontal Line
HP2SS Parallel, Horizontal Line, 1/2 in. Socket Weld Port, SST
HA2S0 Axial, Horizontal Line, 1/2—14 NPT, SST
HA2SS Axial, Horizontal Line, 1/2 in. Socket Weld Port, SST
HP2S0 Parallel, Horizontal Line, 1/2—14 NPT, SST
Remote Mount - Vertical Line
HPVS0 Parallel, Vertical Line, 1/2 in. Socket Weld Port, SST
HPVSS Parallel, Vertical Line, 1/2—14 NPT, SST
HV2S0 Axial, Vertical Line, 1/2—14 NPT, SST
HV2SS Axial, Vertical Line, 1/2 in. Socket Weld Port, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
CA2C0 Needle Valve, Elbow, 1/2—14 NPT, CS
SA2C0 Needle Valve, Elbow and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CA2SS Needle Valve, Elbow, 1/2 in. Socket Weld Port, SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CA2S0 Needle Valve, Elbow, 1/2—14 NPT, SST
SA2S0 Needle Valve, Elbow and Tee, 1/2—14 NPT, SST
CP2SS Needle Valve, Nipple, 1/2 in. Socket Weld Port, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST

Flow-352
Rosemount Inc.

MODEL PHF+35S
Code Instrument Connections (Continued)
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
CB2C0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, CS
SB2C0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2S0 Outside Stem and Yoke Gate Valve, Elbow, 1/2—14 NPT, SST
SB2S0 Outside Stem and Yoke Gate Valve, Elbow and Tee, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST

Code Packing Gland


GV8SC Graphite, 2 in. ANSI Class 600
GV8SB Graphite, 2 in. ANSI Class 300
GV8SA Graphite, 2 in. ANSI Class 150

ProBar®
GH8SC Urethane, 2 in. ANSI Class 600, SST
GH8SB Urethane, 2 in. ANSI Class 300, SST
GH8SA Urethane, 2 in. ANSI Class 150, SST

Code Insert/Retract
IHRS Manual, Dual, SST Rods
IHRC Manual, Dual, CS Rods
IHDS Gear, Dual, SST Rods
IHDC Gear, Dual, CS Rods

Code Isolation Valve


Gate Valve
VB8SG Gate Valve, 2 in. ANSI Class 300, SST
VB8CG Gate Valve, 2 in. ANSI Class 300, CS
VA8SG Gate Valve, 2 in. ANSI Class 150, SST
VA8CG Gate Valve, 2 in. ANSI Class 150, CS
Ball Valve
VB8SB Ball Valve, 2 in. ANSI Class 300, SST
VB8CB Ball Valve, 2 in. ANSI Class 300, CS
VA8SB Ball Valve, 2 in. ANSI Class 150, SST
VA8CB Ball Valve, 2 in. ANSI Class 150, CS

Code Flanged Mount

FA8C 2 in. ANSI Class 150, Weld-Neck RF, CS


FA8S 2 in. ANSI Class 150, Weld-Neck RF, SST
FB8C 2 in. ANSI Class 300, Weld-Neck RF, CS
FB8S 2 in. ANSI Class 300, Weld-Neck RF, SST
FC8C 2 in. ANSI Class 600, Weld-Neck RF, CS
FC8S 2 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly.-Alum. 1/2—14 NPT
B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Flow-353
ProBar® Flowmeter

MODEL PHF+35S
Code Optional Temperature Sensors (For use with Remote Mount Head Styles)
TRR Remote Thermowell and RTD
TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST
9 Special Manifold

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


ProBar®

1 LCD Meter (Rate)- Aluminum Housing


2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHF+35S 120 HAMS0 C0000 GV8SA IHDC VA8C 1 A 1 A

Flow-354
Rosemount Inc.

MODEL PHF+45S
Model Product Description
PHF+45S ProBar® + Flowmeter - Flanged Flo-Tap

Code Line Size

100 10 in. (250 mm)


120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line
HADS0 Direct Mount, 5-Valve Manifold, Horizontal Line, SST

ProBar®
HADSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, SST
HADSN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, SST
HAMS0 Integral, 3-Valve Manifold, Horizontal Line, SST
HAPS0 Direct Mount, No Manifold, Horizontal Line, SST
HAXS0 Direct Mount, Quantity Two, 3-valve Manifold, Horizontal Line, SST
Direct and Integral Mount Heads - Horizontal Line with RTD
HATSN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, SST
HATS0 Integral, 3-Valve Manifold, RTD, Horizontal Line, SST
HATSD Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, SST
Direct and Integral Mount Heads - Vertical Line
HVDSB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, SST
HVDSN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, SST
HVMS0 Integral, 3-Valve Manifold, Vertical Line, SST
HVPS0 Direct Mount, No Manifold, Vertical Line, SST
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
Direct and Integral Mount Heads - Vertical Line with RTD
HVTS0 Integral, 3-Valve Manifold, RTD, Vertical Line, SST
HVTSB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, SST
HVTSD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, SST
HVTSN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, SST

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
CP2SS Needle valve, Nipple, 1/2 in. Socket Weld Port, SST
SP2SS Needle Valve, Nipple and Tee, 1/2 in. Socket Weld Port, SST
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST
CB2SS Outside Stem and Yoke Gate Valve, Elbow, 1/2 in. Socket Weld Port, SST
CC2SS Outside Stem and Yoke Gate Valve, Nipple, 1/2 in. Socket Weld Port, SST
SV2SS Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2 in. Socket Weld Port, SST

Code Packing Gland


GVDSC Graphite, 3 in. ANSI Class 600
GVDSB Graphite, 3 in. ANSI Class 300
GVDSA Graphite, 3 in. ANSI Class 150

Flow-355
ProBar® Flowmeter

MODEL PHF+45S
Code Insert/Retract
IHRS Manual, Dual, SST Rods
IHRC Manual, Dual, CS Rods
IHDS Gear, Dual, SST Rods
IHDC Gear, Dual, CS Rods

Code Isolation Valve

Gate Valve
VCDSG Gate Valve, 3 in. ANSI Class 600, SST
VCDCG Gate Valve, 3 in. ANSI Class 600, CS
VBDSG Gate Valve, 3 in. ANSI Class 300, SST
VBDCG Gate Valve, 3 in. ANSI Class 300, CS
VADCG Gate Valve, 3 in. ANSI Class 150, CS
VADSG Gate Valve, 3 in. ANSI Class 150, SST
Ball Valve
VBDSB Ball Valve, 3 in. ANSI Class 300, SST
VBDCB Ball Valve, 3 in. ANSI Class 300, CS
VADCB Ball Valve, 3 in. ANSI Class 150, CS
VADSB Ball Valve, 3 in. ANSI Class 150, SST

Code Flanged Mount


ProBar®

FADC 3 in. ANSI Class 150, Weld-Neck RF, CS


FADS 3 in. ANSI Class 150, Weld-Neck RF, SST
FBDC 3 in. ANSI Class 300, Weld-Neck RF, CS
FBDS 3 in. ANSI Class 300, Weld-Neck RF, SST
FCDC 3 in. ANSI Class 600, Weld-Neck RF, CS
FCDS 3 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges
0 0-0.1 to 0-3 inH20 (.0-.15 to 0 - 0.75 kPa)
1 0-.5 to 0-25 inH20 (0-.12 to 0-6.22 kPa)
2 0-2.5 to 0-250 inH20 (0-.62 to 0 - 62.2kPa)
3 0-10 to 0-830 inH20 (0-2.48 to 0-206kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly.-Alum. 1/2—14 NPT
B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Code Optional Manifolds


3 Model 305 Manifold Bolted to Transmitter
5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST
9 Special Manifold

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Flow-356
Rosemount Inc.

MODEL PHF+45S
Code Optional Meters
1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)

ProBar®
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHF+45S 240 HAMS0 C0000 GVDSA IHDS VADCG FADC 1 A 1 A

Flow-357
ProBar® Flowmeter

MODEL PHF+45H
Model Product Description
PHF+45H ProBar® + Flowmeter - Flanged Flo-Tap

Code Line Size

100 10 in. (250 mm)


120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line
ProBar®

HADH0 Direct Mount, 5-Valve Manifold, Horizontal Line, Hastelloy-C.


HADHB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Hastelloy-C.
HADHN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Hastelloy-C.
HAMH0 Integral, 3-Valve Manifold, Horizontal Line, Hastelloy-C.
HAPH0 Direct Mount, No Manifold, Horizontal Line, Hastelloy-C.
HATH0 Direct and Integral Mount Heads - Horizontal Line with RTD
HATHB Integral, 3-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.
HATHD Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Hastelloy-C.
HATHN Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Hastelloy-C.
Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Hastelloy-C.
Direct and Integral Mount Heads - Vertical Line
HVDH0 Direct Mount, 5-Valve Manifold, Vertical Line, Hastelloy-C.
HVDHB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Hastelloy-C.
HVDHN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Hastelloy-C.
HVMH0 Integral, 3-Valve Manifold, Vertical Line, Hastelloy-C.
HVPH0 Direct Mount, No Manifold, Vertical Line, Hastelloy-C.
Direct and Integral Mount Heads - Vertical Line with RTD
HVTH0 Integral, 3-Valve Manifold, RTD, Vertical Line, Hastelloy-C.
HVTHB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Hastelloy-C.
HVTHD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Hastelloy-C.
HVTHN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Hastelloy-C.
Remote Mount - Horizontal Line
HA2H0 Axial, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
HA2HS Axial, Horizontal Line, 1/2 in. Socket Weld Port, Hastelloy-C.
HP2H0 Parallel, Horizontal Line, 1/2—14 NPT, Hastelloy-C.
HPVH0 Parallel, Vertical Line, 1/2—14 NPT, Hastelloy-C.
HV2H0 Axial, Vertical Line, 1/2—14 NPT, Hastelloy-C.

Code Instrument Connections

Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve - Hastelloy
CP2H0 Needle Valve, Nipple, 1/2—14 NPT, Hastelloy-C.
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

Code Packing Gland


GVDHC Graphite, 3 in. ANSI Class 600, Hastelloy-C.
GVDHB Graphite, 3 in. ANSI Class 300, Hastelloy-C.
GVDHA Graphite, 3 in. ANSI Class 150, Hastelloy-C.

Flow-358
Rosemount Inc.

MODEL PHF+45H
Code Insert/Retract
IHRS Manual, Dual, SST Rods
IHRC Manual, Dual, CS Rods
IHDS Gear, Dual, SST Rods
IHDC Gear, Dual, CS Rods

Code Isolation Valve

Gate Valve
VCDSG Gate Valve, 3 in. ANSI Class 600, SST
VCDCG Gate Valve, 3 in. ANSI Class 600, CS
VBDSG Gate Valve, 3 in. ANSI Class 300, SST
VBDCG Gate Valve, 3 in. ANSI Class 300, CS
VADCG Gate Valve, 3 in. ANSI Class 150, CS
VADSG Gate Valve, 3 in. ANSI Class 150, SST
Ball Valve
VBDSB Ball Valve, 3 in. ANSI Class 300, SST
VBDCB Ball Valve, 3 in. ANSI Class 300, CS
VADCB Ball Valve, 3 in. ANSI Class 150, CS
VADSB Ball Valve, 3 in. ANSI Class 150, SST

Code Flanged Mount

ProBar®
FADC 3 in. ANSI Class 150, Weld-Neck RF, CS
FADS 3 in. ANSI Class 150, Weld-Neck RF, SST
FBDC 3 in. ANSI Class 300, Weld-Neck RF, CS
FBDS 3 in. ANSI Class 300, Weld-Neck RF, SST
FCDC 3 in. ANSI Class 600, Weld-Neck RF, CS
FCDS 3 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges
1 0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)
2 0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)
3 0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly.-Alum. 1/2—14 NPT
B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Code Optional Manifolds

3 Model 305 Manifold Bolted to Transmitter


5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Code Optional Meters


1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Flow-359
ProBar® Flowmeter

MODEL PHF+45H
Code Optional Hazardous Location Certificates
I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
ProBar®

W Lab Flow Calibration (Average K) (30 in.)


X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHF+45H 240 HAMS0 C0000 GVDHA IHDC VADCG FADC 1 A 1 A

Flow-360
Rosemount Inc.

MODEL PHF+45M
Model Product Description
PHF+45M ProBar® + Flowmeter - Flanged Flo-Tap

Code Line Size

100 10 in. (250 mm)


120 12 in. (300 mm)
140 14 in. (350 mm)
160 16 in. (400 mm)
180 18 in. (450 mm)
200 20 in. (500 mm)
240 24 in. (600 mm)
300 30 in. (750 mm)
360 36 in. (900 mm)
420 42 in. (1066 mm)
480 48 in. (1210 mm)
600 60 in. 1520 mm)
720 72 in. (1820 mm)

Code Head Style


Direct and Integral Mount Heads - Horizontal Line
HADM0 Direct Mount, 5-Valve Manifold, Horizontal Line, Monel

ProBar®
HADMB Direct Mount, 5-Valve Manifold, ANSI B31.1, Horizontal Line, Monel
HADMN Direct Mount, 5-Valve Manifold, NACE, Horizontal Line, Monel
HAMM0 Integral, 3-Valve Manifold, Horizontal Line, Monel
HAPM0 Direct Mount, No Manifold, Horizontal Line, Monel
Direct and Integral Mount Heads - Horizontal Line with RTD
HATM0 Integral, 3-Valve Manifold, RTD, Horizontal Line, Monel
HATMB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Horizontal Line, Monel
HATMD Direct Mount, 5-Valve Manifold, RTD, Horizontal Line, Monel
HATMN Direct Mount, 5-Valve Manifold, RTD, NACE, Horizontal Line, Monel
Direct and Integral Mount Heads - Vertical Line
HVDM0 Direct Mount, 5-Valve Manifold, Vertical Line, Monel
HVDMB Direct Mount, 5-Valve Manifold, ANSI B31.1, Vertical Line, Monel
HVDMN Direct Mount, 5-Valve Manifold, NACE, Vertical Line, Monel
HVMM0 Integral, 3-Valve Manifold, Vertical Line, Monel
HVPM0 Direct Mount, No Manifold, Vertical Line, Monel
Direct and Integral Mount Heads - Vertical Line with RTD
HVTM0 Integral, 3-Valve Manifold, RTD, Vertical Line, Monel
HVTMB Direct Mount, 5-Valve Manifold, RTD, ANSI B31.1, Vertical Line, Monel
HVTMD Direct Mount, 5-Valve Manifold, RTD, Vertical Line, Monel
HVTMN Direct Mount, 5-Valve Manifold, RTD, NACE, Vertical Line, Monel
Remote Mount - Horizontal Line
HA2M0 Axial, Horizontal Line, 1/2—14 NPT, Monel
HA2MS Axial, Horizontal Line, 1/2 in. Socket Weld Port, Monel
HP2M0 Parallel, Horizontal Line, 1/2—14 NPT, Monel
Remote Mount - Vertical Line
HPVM0 Parallel, Vertical Line, 1/2—14 NPT, Monel
HV2M0 Axial, Vertical Line, 1/2—14 NPT, Monel
HV2MS Axial, Vertical Line, 1/2 in. Socket Weld Port, Monel

Code Instrument Connections


Eliminate Instrument Connection Options (For use with Direct and Integral Mount Head Styles)
C0000 Eliminate Instrument Connection Assembly
S0000 Eliminate Instrument Connection Assembly (Steam)
Needle Valve - CS
CP2C0 Needle Valve, Nipple, 1/2—14 NPT, CS
SP2C0 Needle Valve, Nipple and Tee, 1/2—14 NPT, CS
Needle Valve - SST
CP2S0 Needle Valve, Nipple, 1/2—14 NPT, SST
SP2S0 Needle Valve, Nipple and Tee, 1/2—14 NPT, SST
Needle Valve - Monel
CP2M0 Needle Valve, Nipple, 1/2—14 NPT, Monel
Gate Valve - CS
CC2C0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, CS
SC2C0 Outside Stem and Yoke Gate Valve, Nipple and Tee, 1/2—14 NPT, CS
SV2C0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, CS
Gate Valve - SST
CC2S0 Outside Stem and Yoke Gate Valve, Nipple, 1/2—14 NPT, SST
SC2S0 Outside Stem and Yoke Gate Valve, Nipple and Tee, Steam, 1/2—14 NPT, SST
SV2S0 Outside Stem and Yoke Gate Valve, Vertical Line, Nipple and Tee, 1/2—14 NPT, SST

Flow-361
ProBar® Flowmeter

MODEL PHF+45M
Code Packing Gland
GVDMC Graphite, 3 in. ANSI Class 600, Monel
GVDMB Graphite, 3 in. ANSI Class 300, Monel
GVDMA Graphite, 3 in. ANSI Class 150, Monel

Code Insert/Retract
IHRS Manual, Dual, SST Rods
IHRC Manual, Dual, CS Rods
IHDS Gear, Dual, SST Rods
IHDC Gear, Dual, CS Rods

Code Isolation Valve


Gate Valve
VCDSG Gate Valve, 3 in. ANSI Class 600, SST
VCDCG Gate Valve, 3 in. ANSI Class 600, CS
VBDSG Gate Valve, 3 in. ANSI Class 300, SST
VBDCG Gate Valve, 3 in. ANSI Class 300, CS
VADCG Gate Valve, 3 in. ANSI Class 150, CS
VADSG Gate Valve, 3 in. ANSI Class 150, SST
Ball Valve
ProBar®

VBDSB Ball Valve, 3 in. ANSI Class 300, SST


VBDCB Ball Valve, 3 in. ANSI Class 300, CS
VADCB Ball Valve, 3 in. ANSI Class 150, CS
VADSB Ball Valve, 3 in. ANSI Class 150, SST

Code Flanged Mount


FADC 3 in. ANSI Class 150, Weld-Neck RF, CS
FADS 3 in. ANSI Class 150, Weld-Neck RF, SST
FBDC 3 in. ANSI Class 300, Weld-Neck RF, CS
FBDS 3 in. ANSI Class 300, Weld-Neck RF, SST
FCDC 3 in. ANSI Class 600, Weld-Neck RF, CS
FCDS 3 in. ANSI Class 600, Weld-Neck RF, SST

Code DP Ranges
1 0–0.5 to 0–25 inH2O (0–0.12 to 0–6.22 kPa)
2 0–2.5 to 0–250 inH2O (0–0.62 to 0–62.2 kPa)
3 0–10 to 0–830 inH2O (0–2.48 to 0–206 kPa)

Code Output
A 4—20 mA with Digital Signal based on HART

Code Fill Fluid


1 Silicone
2 Inert Fill

Code Housing Material


A Epoxy-Poly.-Alum. 1/2—14 NPT
B Epoxy-Poly.-Alum. CM20
C Epoxy-Poly.-Alum. PG13.5
D Epoxy-Poly.-Alum. G1/2
J 316 SST 1/2—14 NPT
K 316 SST CM 20
L 316 SST PG 13.5
M Epoxy-Poly.-Alum. G1/2

Code Optional Temperature Sensors (For use with Remote Mount Head Styles)

TRR Remote Thermowell and RTD


TXR Remote Thermowell and RTD, Explosion-Proof
TRA Integral RTD, Axial Head
TRP Integral RTD, Parallel Head
TXA Integral RTD, Explosion-Proof, Axial
TXP Integral RTD, Explosion-Proof, Parallel

Code Optional Manifolds

3 Model 305 Manifold Bolted to Transmitter


5 5 Valve Manifold, CS
6 5 Valve Manifold, SST
7 3 Valve Manifold, CS
8 3 Valve Manifold, SST

Code Optional Mounting Brackets


K Coplanar Bracket, 2 in., Pipe/Panel, SST Bolts

Flow-362
Rosemount Inc.

MODEL PHF+45M
Code Optional Meters
1 LCD Meter (Rate)- Aluminum Housing
2 LCD Meter (Rate) - SST Housing
4 External LCD Rate and Total Display

Code Optional Hazardous Location Certificates


I5 FM Intrinsic Safety Approval
C6 CSA Explosion-Proof and Intrinsic Safety Approval
E5 FM Explosion-Proof Approval
K5 FM Explosion-Proof and Intrinsic Safety Approval
ID KEMA/CENELEC Intrinsic Safety Approval
ED KEMA/CENELEC Explosion-Proof Approval

Code Optional Calibration


M Multipoint Flow Calibration (ID ≤ 10 in.)
L Lab Flow Calibration (Average K) (<10 in.)
Z Special Calibration
N Multipoint Flow Calibration (12 in.)
P Multipoint Flow Calibration (14 in., 16 in.)
O Lab Flow Calibration (Average K) (12 in.)
Q Lab Flow Calibration (Average K) (14 in.-16 in.)

ProBar®
R Multipoint Flow Calibration (18 in., 20 in.)
S Lab Flow Calibration (Average K) (18 in.-20 in.)
T Multipoint Flow Calibration (24 in.)
U Lab Flow Calibration (Average K) (24 in.)
V Multipoint Flow Calibration (30 in.)
W Lab Flow Calibration (Average K) (30 in.)
X Multipoint Flow Calibration (36 in.)
Y Lab Flow Calibration (Average K) (36 in.)

Code Optional Quality Assurance


QA1 Dieterich Program
Q21 ANSI B31.1
Q23 ANSI B31.3
Q29 NACE MR-0175-91
QJ2 Special Product Drawing
QM2 ASTM Material-Traceable (Sensor Only)
QT1 Hydrostatic Test EP-4017
QT2 Dye Penetrant ES-1012
QT8 Extended Hydro EP-4046

Typical Model Number: PHF+45M 240 HAMM0 C0000 GVDMA IHDC VADCG FADC 1 A 1 A

Flow-363
ProBar® Flowmeter
ProBar®

364
Flow-364
Rosemount Inc.

ProBar®

Flow-365
ProBar® Flowmeter
ProBar®

366
Flow-366
Rosemount Inc.

ProBar®

Flow-367
ProBar® Flowmeter
ProBar®

368
Flow-368
Rosemount Inc.

ProBar®

Flow-369
ProBar® Flowmeter
ProBar®

Flow-370
Rosemount Inc.

Specifications

FUNCTIONAL SPECIFICATIONS Pressure Limits

Service(1) 0 to 1440 psig (100 barg) @ 100 °F (37.8 °C). Contact


the factory for higher pressures.
Liquid, gas, or steam.
Temperature
Pipe Sizes(2) Storage: -50 °F to 230 °F (-46 °C to 110 °C).
1/2 in. to 72 in. (12 mm to 1800 mm). With integral meter: -40 °F to 185 °F
(-40 °C to 85 °C).
Ranges(3) For HATSB, HVTSB, HADSB, and HVDSB
Range 0: 0-0.6 in. to 0-3 in. H20 head styles and regular flanged, Flo-Tap models:
(0-0.15 to 0-7.5 kPa). -40 °F to 750 °F (-40 °C to 398 °C).
Range 1: 0-0.5 in. to 0-25 in. H20 Remote mount (SST and Monel):

ProBar®
(0-0.12 to 0-7.22 kPa). -40 °F to 850 °F (-40 °C to 454 °C).
Range 2: 0-2.5 in. to 0-250 in. H20 Remote mount (Hastelloy-C):
(0-0.62 to 0-62.2 kPa).
-40 °F to 900 °F (-40 °C to 482 °C).
Range 3: 0-10 in. to 0-1000 in. H20
(0-2.48 to 0-248 kPa). Remote mount (Hastelloy-C) with remote
temperature sensor :
Indication -40 °F to 1200 °F (-40 °C to 649 °C).
Ambient: -40 °F to 185 °F (-40 °C to 85 °C).
Optional two-line, scalable digital LCD meter.
With integral meter: -4 °F to 175 °F (-20 °C to 80 °C).
Output
4-20mADC, flow rate output. Damping
Digital HART protocol superimposed on a 4–20mA Analog output response to a step input change is
signal, available to any host that conforms to the user selectable from 0 to 36 seconds for one time
HART protocol. constant. This software damping is in addition to
sensor module response time.
Power Supply
External power supply required. Operates on Turn on Time
10.5-55VDC with no load.
Performance within specification less than two
4–20mA Load Limitations seconds after power is applied.

Maximum loop resistance is determined by the Humidity Limits


voltage level of the external power supply, as shown
in the following flowmeter chart. 0 to 100% relative humidity.

1935
Load (Ohms)

1500

1000

500 Operating
Region
0
10.5 20 30 40 55
42.4 1
Voltage (V dc)

FIGURE 30. Load Limitations.


For CSA Approval, powersupply must not exceed 42.2V.

(1) Fluid density and Reynolds number corrections should be


compensated per DSI Annubar Handbook Equation #2.1-2.5.
(2) Consult the factory for line sizes > 72 inches. Multipoint
calibration is available for line sizes 1/2 in. to 36 in. Consult the
factory for calibration ranges in larger line sizes.
(3) Consult the factory for calibration ranges for range 3.
371
Flow-371
ProBar® Flowmeter

PERFORMANCE SPECIFICATIONS Ambient Temperature Effect

Accuracy(1) Per 50 °F (28 °C):

(Including linearity, hysteresis, and repeatability) • +(0.0188% URL + 0.0938% span) spans
from 1:1 to 10:1.
Multipoint calibration: + 0.5% of rate
(at reference conditions). • +(0.038% URL + 0.188% span) spans
from 10:1 to 100:1.
No Flow Calibration
For range 1: +(0.18% URL + 0.375% span).
+ 1.1% of volumetric flow rate.
Static Pressure Effect
+ 3% of volumetric flow rate, elbow mount.
Zero error (can be calibrated out at line pressure).
Flow Turndown
• 0.1% of URL/1,000 psi (6.9MPa) for line
10:1 flow turndown—multipoint calibration.(2) pressures from 0 to 2,000 psi (0 to 13.7MPa).
ProBar®

5:1 flow turndown—no calibration. • 0.2% of URL/1,000 psi (6.9MPa) for line
pressure above 2,000 psi (13.7MPa).
Stability
For range 1:0.25% of URL/1,000 psi (6.9MPa).
+ 0.25% of URL for five years.
Mounting Position Effect
Time Response (Electronics Only)
Zero shifts up to 2.5 inches ws (0.62kPa) which can
Dead time (Td): 45 milliseconds (nominal). be calibrated out. No span effect.

Time constant (Tc): 55 milliseconds. ProBar Flowmeter Operating Limitations


Update rate: 20 times per sec. (minimum).
Model Minimum Reynold’s Number (Rerod)
Vibration Effect 10 2300
½ inch 4000
Less than 0.1% of URL per g when tested from
15 Hz to 2000 Hz in any axis relative to pipe- 15/16 6500
mounted process conditions. 25/26 10000
35/36 15000
Power Supply Effect 45/46 25000
Where: ρ = fluid density in lbm/ft3
Less than 0.005% of calibrated span per volt.
Rerod = dVρ d = probe width in feet
RFI Effect m V = velocity of fluid in ft/sec
m = fluid viscosity in lbm/ft–sec
0.1% of span from 20 MHz to 1000MHz and for
®
field strength up to 30 V/m. See the ProBar Flow Handbook (DS-4012
or 00807-0100-1192) for detailed information.

(1) Calibration not available for Range 0.


Water Flow Calibration (Test condition: Water at 60 °F, 50 psig,
in sch40, sch80, or sch std pipes) in totalizing test conditions.
(2) Flow turndown is based on the upper range limit of the range
selected and may vary depending on customer application, or
ProBar operating limitations

Flow-372
Rosemount Inc.

PHYSICAL SPECIFICATIONS Electronics

Electrical Considerations Stainless steel models.


• Vent valves and process flanges: 316 SST
½ in.— 14 NPT, PG 13.5, and CM20 conduit.
HART interface connections permanently • Process isolating diaphragms: 316L SST
fixed to terminal block. • O-rings: Glass-filled TFE

SENSOR Hastelloy-C Models


• Vent valves and process flanges:
316/316L SST.
Hastelloy–C models.
Hastelloy–C (Flanged models, Sensors • Process isolating diaphragms:
10, 25/26, 45/46). Hastelloy–C models.
• O-rings: Glass-filled TFE.
Monel (Flanged models, Sensors 10, 25/26, 45/46).
Monel Models
Integral Valve and Direct Mount • Vent valves and process flanges: Monel.

ProBar®
Head Styles (3 and 5 Valve)
• Process isolating diaphragms: Monel.
Material • O-rings: Glass-filled TFE.

316 SST (Hastelloy–C and Monel options).


O–Rings
Hazardous Locations Certifications
Teflon® (Grafoil above 500 °F [260 °C]). Factory Mutual (FM) Approvals
E5 — Explosion Proof for Class I, Division 1, Groups
Bolts
B, C, and D. Dust-Ignition Proof for Class II, Division
316 SST. 1, Groups E, F, and G. Dust-Ignition Proof for Class
III, Division 1. NEMA 4X. Factory-sealed.
Flange and Isolation Valves
I5 — Intrinsically safe for use in Class I, Division 1,
316L SST. Flange pressure limits are per ANSI Groups A, B, C, and D; Class II, Division 1, Groups E,
B16.5 for 316 SST and material per SA182. Flange F, and G; Class III, Division 1 when connected in
face finish ANSI B16.5, 125 to 250 RMS. accordance with Rosemount drawings 03031-1019
and 00275-0081 (when used with HART
Packing Gland Assembly Communicator Model 275), or
00268-0031 (when used with Rosemount Model 268
Packing Gland Communicator). Temperature Code T4. Non-
316 SST. incendive for Class I, Division 2, Groups A, B, C, and
D. NEMA 4X. Factory-sealed.
Packing
Graphite AFP–127. K5 — Combination of E5 and I5. NEMA 4X.
Factory-sealed.
Flange Mounting Hardware
FM Approved Entity Parameters FM Approved for Class I, II, and III;
(Includes nuts, bolts, and gasket) 316 SST or CS. for Model 8900V (1) Division 1 and 2; Groups

VMax = 40 V dc A–G
Temperature Options IMax = 165 mA A–G
IMax = 225 mA C–G
Integral RTD IMax = 160 mA (Option Code T1) A–G
PMax = 1 W A–G
100 Ω Platinum RTD. CI = 0.01 µF (Output Code A) A–G
LI = 10 µH A–G
Remote LI = 1.05 mH (Output Code A with T1) A–G
100 Ω Platinum RTD. (1) When connected in accordance with Rosemount drawings 3031-
1019 and 00275-0081 (for use with the HART Communicator
Spring loaded with ½ —14 NPT nipple and union. Model 275), or 00268-0031 (for use with the Rosemount Model
268 Communicator.)

Thermowell: ½ in. × ½ —14 NPT, 316 SST with


½ in. CS weld couplet, u = 2 in. × 2 in.

Flow-373
ProBar® Flowmeter

Canadian Standards Association (CSA) KEMA/CENELEC


ED — Explosion Proof.
C6 — Explosion Proof for Class I, Division 1, Groups EEx d IIC T5 (Tamb = 70 C); EEx d IIC T6
C, and D. Dust-Ignition Proof for Class II, Division 1, (Tamb = 40 C).
Groups E, F, and G. Dust-Ignition Proof for Class III, Enclosure Type: IP65.
Division 1. Suitable for Class I, Division 2, Groups A,
B, C, and D. CSA Enclosure-Type 4X. Factory-sealed. ID — Intrinsically Safe.
EEx ia IIC T5 (Tamb = -45 to +40 °C); EEx ia IIC T54
Intrinsically safe for use in Class I, Division 1, Groups (Tamb = -45 to +70 °C).
A, B, C, and D when connected in accordance with Enclosure Type: IP65.
Rosemount drawings 03031-1024. Temperature Code Ui = 30V dc.
T3C. CSA Enclosure-Type 4X. Factory-sealed. Ii = 200 mA.
Pi = 0.9 W.
CSA Approved for Class Ci = 0.012 µF.
CSA Approved
Barriers for Model 8900V (2)
I, Division 1 and 2, Li = 0.
Groups

≤ 30 V, ≥ 330 V ≤ 28 V, ≥ 300 V
≤ 25 V, ≥ 200 V ≤ 22 V, ≥ 180 V
Code A
Output

A–D
ProBar®

≤ 30 V, ≥ 150 V C–D
Supply ≤ 28V, ≥ 300 V
Return ≤ 10 V, ≥ 47 V
Code M
Output

A–D
Supply ≤ 30 V, ≥ 150 V C–D
Return ≤ 10 V, ≥ 47 V

(2) When connected in accordance with Rosemount drawings


00275-0082 and 3031-1024.

May be protected by one or more of the following U.S. Patent Nos.4,559,836; 4,717,159; 5,710,370; 5,773,726; 4,633,713;
and various foreign patents. Other foreign patents issued and pending.

Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
Coplanar, MV, and Multivariable are trademarks of Rosemount Inc.
PlantWeb is a mark of the Fisher-Rosemount group of companies.
Mass ProBar, ProBar, and Annubar are registered trademarks of Dieterich Standard Inc.
HART is a registered trademark of the HART Communications Foundation.
Monel is a registered trademark of International Nickel Co.
Teflon is a registered trademark of E. I. du Pont de Nemours & Co.
Hastelloy C and Hastelloy C-276 are registered trademarks of Cabot Corp.
Windows is a trademark of Microsoft Corp.

Dieterich Standard Inc. Rosemount Inc. Fisher-Rosemount Limited Fisher-Rosemount


5601 North 71st Street 8200 Market Boulevard Heath Place Singapore Pte Ltd.
Boulder, CO 80301 Chanhassen, MN 55317 USA Bognor Regis 1 Pandan Crescent
Tel (303) 530-9600 Tel 1-800-999-9307 West Sussex PO22 9SH Singapore 128461
Fax (303) 530-7064 Telex 4310012 England Tel (65) 777-8211
Fax (612) 949-7001 Tel 44 (1243) 863 121 Fax (65) 777-0947
Fax 44 (1243) 867 5541 Tlx RS 61117 FRSPL

© 1998 Rosemount Inc. INT


ED
PR

IN
http://www.rosemount.com U. S. A.

¢00809-0100-4716;¤
00813-0100-4761 Rev. DA 11/98
Flow-374