Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

WORK INSTRUCTIONS-TESTING OF PHYSICAL PROPERTIES D.O.C.

No : LAB

REF. No ASTM D 412


VALVE ADHESION
PAGE No : 1 OF 1

Equipments used :

1 Scissor / Blade

2 Tensile Tester

3 Measuring Scale.

Sample Preparation :

1 Take one sample of Cured tube (Fixed with valve).

2 Cut the Strip arround 10 mm width of valve base fixed with tube and measure the width of strip.

Procedure :

1 Separate the valve base rubber to the tube from one end with help of blade.

2 Fix the Specimen in jaws and start pulling of It , ensure that Machine Speed Should be 50mm/min .

3 When Valve-base starts getting separated from the tube , observe the Reading from Dial-Guage .

4 Record the reading when the needle of dial gauge reaches its highest.

Calculation :

-- Direct Recording of Observations , No Calculations .

PRECAUTIONS :

1 Cured tubes must be free from defect like Valve Under Cure , Valve Blister etc.

Revision History :
S. No. Revision No. Revision Date Revision Details Prepared by Checked by Approved by

01 00 01.01.2018 As per IATF : 16949

02 01 27.02.19 Updation