Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Republic of the Philippines Document Code: CEA-BF-026

UNIVERSITY OF ANTIQUE Revision No.: 00


Sibalom, Antique
Telefax No. (036) 543-8161 Effectivity Date: 01/04/2016
E-mail: ua@antiquespride.edu.ph Page: 1 of 2

COLLEGE OF ENGINEERING AND ARCHITECTURE


cea@antiquespride.edu.ph
MIDTERM EXAMINATION
2ND Semester, AY 2020-2021
CENGG11 (Structural Steel Design)

Name:___________________________________________________________ Score__________________

I. True or false (write your answer on the space provided)


1) Steel purlins are considered beams loaded uniformly all throughout its entire length. _______________
2) Wind loads are also considered as dead load. ________________
3) Angle bars are usually used as steel purlins in a trusses system. ______________
4) Wide flanges and American standard beams are the most common steel beams. ________________
5) Non compact section are section with lateral support all throughout its entire span. __________________
6) Yield stress Fy is the capacity of steel section in Mpa. ________________
7) Compact sections are sections with lateral support. ________________
8) Steel structures are connected using bolts, rivets and welding. __________________
9) Steel structures can also be used for towers and bridges. _________________
10) Steel pipes are commonly used as steel reinforcement for columns. _______________

II. Multiple Choice (select the best answer of the choices provided, encircle the letter of your choice)
1) Wide flange section has a designation of: 6) ) For laterally supported W shape and I sections the method of
a. I b. W c. HP determining if section is compact
2) For laterally supported w shape and I sections the method of determining if d 1680 bf 170
section is compact a. < b < c. all of the
bf 170 bf 170 tw √ fy 2tf √ fy
a. > b. < c. none of the choices
2tf √ fy 2tf √ fy 7) Allowable bending stress for steel non-compact section.
choices a. 0.60 fy b. 0.66fy c. 0.50fy
3) Channels are designated as: 8) Allowable bending stress for steel compact section.
a. L b. C c. M a. 0.60 fy b. 0.66fy c. 0.50fy
4) For laterally supported W shape and I sections the method of determining if section 9) Maximum moment for three moving loads can be obtained if the midspan
is non compact of beam coincides with:
bf 170 bf 170 a. Resultant and smaller load b. Resultant and bigger load c.
a. > b. < c. none of the all of the choices
2tf √ fy 2tf √ fy 10) Formula for bending moment of steel section.
choices a. fb = Mc/I b. fb = M/Sc. all of the choices
5) Most common section used a steel purlin.
a. C section b. I section c. W section

2)

III. PROBLEM SOLVING


A simply supported beam having a span of10m A simply supported beam having a span of 8m
carries a moving load 8 kN, 3 KN and10 kN carries a uniform load of 20kN/m over its entire
respectively. Its has a fixed distance of 1.5m on length and a concentrated load P at midspan.
all the loads. Fy = 350 MPa. Properties of the beam
Fy = 375 Mpa
Properties of the beam Flange width b = 450mm
W24 x55 Flange thickness tf = 25mm
Depth = 590mm Web height d = 600mm
Flange Width = 180mm Web thickness tw= 30mm
tw = 20 mm Properties of the beam
tf = 22 mm a. Solve for I Flange width = 465mm
b. Check if compact or partially or non- Flange thickness = 25mm
compact section Web height = 570mm
a. Compute the actual bending stress and c. c. Solve for the load P at midspan Web thickness = 30mm
check if safe or not
From the maximum moment obtained above, solve
for the maximum allowable bending stress of the
beam and compare with allowable Fb=0.60Fy
(Fy=400 Mpa)

Prepared by: Checked by:

Engr. OSCAR JUN D. ALECANDO Engr. AJIMAR S. BORLAN


Subject Instructor Program Head

Approved by:
Republic of the Philippines Document Code: CEA-BF-026
UNIVERSITY OF ANTIQUE Revision No.: 00
Sibalom, Antique
Telefax No. (036) 543-8161 Effectivity Date: 01/04/2016
E-mail: ua@antiquespride.edu.ph Page: 2 of 2

Engr. Christine C. Vegafria


DEAN, CEA

You might also like