Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Automation Controls Catalog

TV-10/TV-15 rated
1a 30A, 2a 25A
power relays
HE RELAYS

FEATURES
Protective construction 1. Excellent resistance to contact 4. Compatible with all major safety
• Dust cover type:Plug-in, TM and Screw terminal types welding standards
• Flux-resistant type:PC board type
Owing to the pre-tension and kick-off UL, CSA, VDE and TÜV certified
mechanism, the 1 Form A passes TV- 5. Terminals are available
50 33
15 and the 2 Form A passes TV-10.
2. High-capacity and long life
Contact
TYPICAL APPLICATIONS
1 Form A type 2 Form A type
35.8
arrangement 1. Office equipment
Contact capacity 30A 25A Copiers, package air conditioners,
Electrical life
2×10 5 automatic vending machines.
(at 20 times/min.)
2. Industrial equipment
1 Form A Plug-in type Mechanical life
(at 180 times/min.)
DC type: 107, AC type: 5×106 Machine tools, molding equipment,
3. Excellent surge resistance wrapping machines, food processing
Between contacts and coil, the surge equipment, etc.
(Unit:mm)
voltage is more than 10,000 V 3. Home appliances
(when surge waveform accords with Water heaters and air heating
JEC-212-1981). equipment.

Single side stable type


Type
HE 1 Form A, 2 Form A
Insulation gap Min. 8 mm
Plug-in, TM and Screw
PC board type:
Distance between contacts* terminal types:
Min. 2.5 mm .098 inch
Min. 3 mm .118 inch
Between open contacts 2, 000 Vrms for 1 min.
Breakdown
voltage Between contact and
5, 000 Vrms for 1 min.
coil

* Reference value

CLASSIFICATION
Type PC board Plug-in TM Screw terminal
Operating funciton Single side stable
Contact arrangement 1 Form A 1 Form A 2 Form A 1 Form A 2 Form A 1 Form A 2 Form A

ORDERING INFORMATION
HE

Contact arrangement Operate voltage Terminal shape Nominal coil voltage


1a:1 Form A(Single side stable type) N:70%of nominal voltage Nil:Plug-in type DC:6, 12, 24, 48, 100, 110V
2a:2 Form A(Single side stable type) S :Screw terminal type AC:12, 24, 48, 100( 100/120) , 200( 200/240)V
Q :TM type
P :PC board type

2019.03 industrial.panasonic.com/ac/e/ ー1ー © Panasonic Corporation 2019 ASCTB183E 201903


HE

TYPES
1. PC board type (1 Form A, DC coil) (Single side stable type)
1 Form A
Nominal coil voltage
Part No.
6V DC HE1aN-P-DC6V
12V DC HE1aN-P-DC12V
24V DC HE1aN-P-DC24V
48V DC HE1aN-P-DC48V
100V DC HE1aN-P-DC100V
110V DC HE1aN-P-DC110V
Standard packing: Carton: 25 pcs.; Case: 100 pcs.

2. Plug-in type (Single side stable type)


1 Form A 2 Form A
Type Nominal coil voltage
Part No. Part No.
6V DC HE1aN-DC6V HE2aN-DC6V
12V DC HE1aN-DC12V HE2aN-DC12V
24V DC HE1aN-DC24V HE2aN-DC24V
DC type
48V DC HE1aN-DC48V HE2aN-DC48V
100V DC HE1aN-DC100V HE2aN-DC100V
110V DC HE1aN-DC110V HE2aN-DC110V
12V AC HE1aN-AC12V HE2aN-AC12V
24V AC HE1aN-AC24V HE2aN-AC24V
AC type 48V AC HE1aN-AC48V HE2aN-AC48V
100/120V AC HE1aN-AC100V HE2aN-AC100V
200/240V AC HE1aN-AC200V HE2aN-AC200V
Standard packing: Carton: 20 pcs.; Case: 100 pcs.

3. TM type (Single side stable type)


1 Form A 2 Form A
Type Nominal coil voltage
Part No. Part No.
6V DC HE1aN-Q-DC6V HE2aN-Q-DC6V
12V DC HE1aN-Q-DC12V HE2aN-Q-DC12V
24V DC HE1aN-Q-DC24V HE2aN-Q-DC24V
DC type
48V DC HE1aN-Q-DC48V HE2aN-Q-DC48V
100V DC HE1aN-Q-DC100V HE2aN-Q-DC100V
110V DC HE1aN-Q-DC110V HE2aN-Q-DC110V
12V AC HE1aN-Q-AC12V HE2aN-Q-AC12V
24V AC HE1aN-Q-AC24V HE2aN-Q-AC24V
AC type 48V AC HE1aN-Q-AC48V HE2aN-Q-AC48V
100/120V AC HE1aN-Q-AC100V HE2aN-Q-AC100V
200/240V AC HE1aN-Q-AC200V HE2aN-Q-AC200V
Standard packing: Carton: 20 pcs.; Case: 100 pcs.

4. Screw terminal type (Single side stable type)


1 Form A 2 Form A
Type Nominal coil voltage
Part No. Part No.
6V DC HE1aN-S-DC6V HE2aN-S-DC6V
12V DC HE1aN-S-DC12V HE2aN-S-DC12V
24V DC HE1aN-S-DC24V HE2aN-S-DC24V
DC type
48V DC HE1aN-S-DC48V HE2aN-S-DC48V
100V DC HE1aN-S-DC100V HE2aN-S-DC100V
110V DC HE1aN-S-DC110V HE2aN-S-DC110V
12V AC HE1aN-S-AC12V HE2aN-S-AC12V
24V AC HE1aN-S-AC24V HE2aN-S-AC24V
AC type 48V AC HE1aN-S-AC48V HE2aN-S-AC48V
100/120V AC HE1aN-S-AC100V HE2aN-S-AC100V
200/240V AC HE1aN-S-AC200V HE2aN-S-AC200V
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
Note: The TM type of the screw terminals are also available.
* Terminal sockets available.

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー2ー © Panasonic Corporation 2019 ASCTB183E 201903
HE

RATING
1.Coil data
• Operating characteristics such as ‘Operate voltage’ and ‘Release voltage’ are influenced by mounting conditions, ambient temperature, etc.
Therefore, please use the relay within ± 5% of rated coil voltage.
• ‘Initial’ means the condition of products at the time of delivery.
1) AC coils
Pick-up voltage Drop-out voltage Nominal operating current Max. applied voltage
Nominal coil voltage Nominal operating power
(at 20°C 68°F) (at 20°C 68°F) [±10%] (at 20°C 68°F) (at 20°C 68°F)
12V AC 138mA 1.7VA
24V AC 70%V or less of 15%V or more of 74mA 1.8VA
110%V of
48V AC nominal voltage nominal voltage 39mA 1.9VA
nominal voltage
100/120V AC (Initial) (Initial) 18.7 to 2.1mA 1.9 to 2.7VA
200/240V AC 9.1 to 10.8mA 1.8 to 2.6VA

2) DC coils
Nominal operating
Pick-up voltage Drop-out voltage Coil resistance Nominal operating Max. applied voltage
Nominal coil voltage current
(at 20°C 68°F) (at 20°C 68°F) [±10%] (at 20°C 68°F) power (at 55°C 131°F)
[±10%] (at 20°C 68°F)
6V DC 320mA 18.8Ω 1.92W
12V DC 160mA 75Ω 1.92W
24V DC 70%V or less of 10%V or more of 80mA 300Ω 1.92W 110%V of
nominal voltage nominal voltage
48V DC 40mA 1,200Ω 1.92W nominal voltage
(Initial) (Initial)
100V DC 19mA 5,200Ω 1.92W
110V DC 18mA 6,300Ω 1.92W

2. Specifications
Characteristics Item Specifications
Contact material AgSnO2 type
Contact Arrangement 1 Form A 2 Form A
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Nominal switching capacity (resistive load) 30A 277V AC 25A 277V AC
Max. switching power 8,310VA 6,925VA
Max. switching voltage 277V AC, 30V DC
Rating
Max. switching current 30A 25A
Nominal operating power DC: 1.92W, AC: 1.7 to 2.7VA
Min. switching capacity (Reference value)*1 100mA 5V DC
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Between open contacts 2,000 Vrms for 1min (Detection current: 10mA.)
Breakdown voltage
Between contact sets — 4,000 Vrms for 1min (Detection current: 10mA.)
(Initial)
Between contact and coil 5,000 Vrms for 1min (Detection current: 10mA.)
Electrical
characteristics Surge breakdown voltage*2
Min. 10,000V
(between contact and coil) (Initial)
Operate time (at nominal voltage) (Initial) Max. 30ms (excluding contact bounce time)
DC: Max.10ms (excluding contact bounce time, without diode),
Release time (at nominal voltage) (Initial)
AC: Max. 30ms (excluding contact bounce time)
Functional Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Shock resistance
Mechanical Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
characteristics Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
Vibration resistance
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Mechanical DC: Min. 107 (at 180 times/min.), AC: Min. 5×106 (at 180 times/min.)
Expected life Min. 105 (25A 277V AC)
Electrical (resistive load) (at 20 times/min.) Min. 2×105 (30A 250V AC)
Min. 2×105 (20A 250V AC)
Ambient temperature: –50°C to +55°C –58°F to +131°F
Conditions for operation, transport and storage*3 Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature),
Conditions Air pressure: 86 to 106kPa
Max. operating speed 20 times/min. (at max. rating)
PC board type: approx. 80g 2.82oz, Plug-in type/TM type: approx. 90g 3.17oz,
Unit weight
Screw terminal type: approx. 120g 4.23oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー3ー © Panasonic Corporation 2019 ASCTB183E 201903
HE

REFERENCE DATA
1 Form A Type
1. Maximum switching power 2. Life curve 3. Coil temperature rise (DC type)
Measured portion:Coil inside
Contact current:30A
100 1,000 70
50 500
60

No. of operations(×10 4)
30

Temperature rise(℃)
20℃
Contact current(A)

20
50
10 100 40℃
250V AC resistive load
50 30V DC resistive load 40 60℃
5

30
1 10
20
0.5 5
10

0 1 0
30 100 500 1,000 0 5 10 15 20 25 30 35 100 110 120
Contact voltage(V) Contact current(A) Coil applied voltage(%V)

4. Ambient temperature characteristics


Tested sample:HE1aN-120V AC, 6pcs.
(%)

30
Rate of change

20 Ave.
Ave.

10 Release
voltage

ー40 ー20 0
20 40 60 80
Ambient
(℃)
temperature
ー10

ー20
Operate voltage
ー30

2 Form A Type
1. Maximum switching power 2. Life curve 3. Coil temperature rise (DC type)
Measured portion:Coil inside
Contact current:25A
100 1,000 70
50 500
60
No. of operations(×10 4)

30 AC resistive load
Temperature rise(℃)
Contact current(A)

20 20℃
50 40℃
10 100 60℃
5 50 250V AC resistive load 40
30V DC resistive load
DC resistive load
30
1 10
20
0.5 5
10

0.1 1 0
10 30 100 500 1,000 0 5 10 15 20 25 30 35 0 100 110 120
Contact voltage(V) Contact current(A) Coil applied voltage(%V)

4. Ambient temperature characteristics


Tested sample:HE2aN-120V AC, 6 pcs.
(%)

30
Ave.
Rate of change

20 Ave.

Release
10 voltage

ー40 ー20 0
20 40 60 80
Ambient
Operate (°
temperature C)
voltage ー10

ー20

ー30

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー4ー © Panasonic Corporation 2019 ASCTB183E 201903
HE

DIMENSIONS (mm) CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website.
1. PC board type
1 Form A External dimensions Schematic (Bottom view) PC board pattern (Bottom view)
CAD Single side stable type Single side stable type
38 33 24
1 4
4.7

6 5

36.3

8.4
18.6
0.5
4
0.8 1.6 4.7 1.6 0.8
6ー2dia.
32 hole
32

Tolerance ±0.1
18.6
8.4

General tolerance
Less than 1mm:±0.1
Min. 1mm less than 3mm:±0.2
24 Min. 3mm:±0.3

2. Plug-in type External dimensions Schematic (Bottom view)


1 Form A Single side stable type Single side stable type
CAD 2ー4.5dia. 36.4
1 4

6 5
33

R4

40 Panel cutout
8.4 10.25 50
0.8 6.35 40
#250 tab terminal 2ー4.5dia.
10.4

Tolerance ±0.1
35
3.5

0.8

General tolerance
Less than 1mm:±0.1
Min. 1mm less than 3mm:±0.2
Min. 3mm:±0.3

2 Form A External dimensions Schematic (Bottom view)


CAD Single side stable type Single side stable type
36.4
2ー4.5dia. 14.4 1 2 3 4

6 5
33

R4

Panel cutout
40
8.4 10.25 50
40
0.8 6.35
#250 tab terminal
2ー4.5dia.
10.4

Tolerance ±0.1
35
3.5

0.8

General tolerance
Less than 1mm:±0.1
Min. 1mm less than 3mm:±0.2
Min. 3mm:±0.3

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー5ー © Panasonic Corporation 2019 ASCTB183E 201903
HE
3. TM type External dimensions Schematic (Bottom view)
CAD Single side stable type Single side stable type
1 Form A 2 Form A 1 4
47.6 47.6
36.4 36.4
14.4

6 5
4.5

4.5
33
1 2 3 4

33
R4
R4

40
50 40 6 5
8.4 10.25 60 50
0.8 6.35 8.4 10.25 60
#250 tab terminal 0.8 6.35
#250 tab terminal
Panel cutout

10.4
47.6

10.4
35 2ー4.5dia.

35
Tolerance ±0.1
3.5

3.5
0.8

0.8
General tolerance
Less than 1mm:±0.1 General tolerance
Min. 1mm less than 3mm:±0.2 Less than 1mm:±0.1
Min. 3mm:±0.3 Min. 1mm less than 3mm:±0.2
Min. 3mm:±0.3

4. Screw terminal type External dimensions Schematic (Bottom view)


1 Form A Single side stable type Single side stable type
CAD 51
M4.5 14.4 1 4
17.5

6 5
21.5

2ー4.5dia. R4
16.5

Panel cutout
M3.5 33.5
40 40
2ー4.5dia.
50
7.5

Tolerance ±0.1
44.5
3.5

0.8

General tolerance
Less than 1mm:±0.1
Min. 1mm less than 3mm:±0.2
Min. 3mm:±0.3

2 Form A External dimensions Schematic (Bottom view)


CAD Single side stable type Single side stable type
51
36.4 1 2 3 4
M4 14.4
17.5

6 5
21.5

2ー4.5dia. R4
Panel cutout
16.5

33.5 40
M3.5 2ー4.5dia.
40
50

Tolerance ±0.1
7.5
44.5
3.5

0.8

General tolerance
Less than 1mm:±0.1
Min. 1mm less than 3mm:±0.2
Min. 3mm:±0.3

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー6ー © Panasonic Corporation 2019 ASCTB183E 201903
HE

MOUNTING METHOD
1. Plug-in type 2. Screw terminal type 3. Allowable installation wiring size for
screw terminal types and terminal
M4 screw
M4 screw
sockets
Washer
FASTON
#250
Washer Due to the UP terminals, it is possible to
either directly connect the wires or use
crimped terminal.

SAFETY STANDARDS
UL (Recognized) CSA (Certified) VDE (Certified)* TÜV (Certified) TV rating (UL/CSA)
Item
File No. Contact rating Cycles File No. Contact rating File No. Contact rating File No. Rating Cycles File No. Rating
1 FormA E43028 30A 277V AC 105 LR26550 30A 277V AC 40006681 30A 250V AC (cosφ =1.0) B 11 04 30A 250V AC (cosφ =1.0) 105 UL: E43028 TV-15
30A 30V DC 105 30A 30V DC 30A 250V AC (cosφ =0.4) 13461 293 30A 250V AC (cosφ =0.4) 105 CSA: LR26550 TV-15
1.5HP 125V AC 105 1.5HP 125V AC 5A 110V DC (0ms) 8A 110V DC (0ms) 105 — —
3HP 250V AC 105 3HP 250V AC — — — — —
2 FormA E43028 25A 277V AC 105 LR26550 25A 277V AC 40006681 25A 250V AC (cosφ =1.0) B 11 04 25A 250V AC (cosφ =1.0) 105 UL: E43028 TV-10
25A 30V DC 105 25A 30V DC 25A 250V AC (cosφ =0.4) 13461 293 25A 250V AC (cosφ =0.4) 105 CSA: LR26550 TV-10
1HP 125V AC 105 1HP 125V AC 5A 110V DC (0ms) 8A 110V DC (0ms) 105 — —
2HP 250V AC 105 2HP 250V AC — — — — —
*VDE: Approved for products having a different last digit of Part No. Please contact us.

NOTES
1. For cautions for use, please read 5. Firmly insert the receptacles so that 7. When using the push-on blocks for
“GENERAL APPLICATION there is no slack or looseness. To the screw terminal type, use crimped
GUIDELINES”. remove a receptacle, 19.6 to 39.2 N terminals and tighten the screw-down
2. The dust cover should not be (2 to 4 kg) of pulling strength is terminals to the torque below.
removed since doing so may alter the required. Do not remove more than M4.5 screw: 147 to 166.6 N⋅cm (15 to 17
characteristics. one receptacle at one time. Always kgf·cm)
3. Avoid use under severe remove one receptacle at a time and M4 screw: 117.6 to 137 N·cm (12 to 14
environmental conditions, such as pull it straight outwards. kgf·cm)
high humidity, organic gas or in dust, 6. When using the AC type, the operate M3.5 screw: 78.4 to 98 N·cm (8 to 10
oily locations and locations subjected time due to the in-rush phase is 20 ms kgf·cm)
to extremely frequent shock or or more. Therefore, it is necessary for
vibrations. you to verify the characteristics for
4. When mounting, use spring your actual circuit.
washers. Optimum fastening torque
ranges from 49 to 68.6 N·m (5 to 7
kgf·cm).

Please refer to "the latest product specifications"


when designing your product.
• Requests to customers :
https://industrial.panasonic.com/ac/e/salespolicies/

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー7ー © Panasonic Corporation 2019 ASCTB183E 201903
ACCESSORIES HE RELAYS
TERMINAL SOCKETS
FEATURES
1. Snap-in mounting to DIN rails is 3. Hold-down clips can be stored in
possible main unit
Can be inserted into 35 mm 1.378 inch Because the hold-down clips can be
wide DIN rails. Removal is easy, too. stored in the main unit, there is no need
2. Sure and easy wiring to remove them when, for example,
The use of UP terminals makes wiring wiring is changed.
exceptionally easy and sure.

TYPES
No. of poles Types Part No.
For 1 Form A Single side stable type JH1-SF
For 2 Form A Single side stable type JH2-SF
Standard packing: Carton: 10 pcs.; Case: 50 pcs.

SPECIFICATIONS
Item Specifications
Arrangement 1 Form A 2 Form A
Max. continuous current 30A 250V AC 20A 250V AC
Breakdown voltage (initial) 2,000 Vrms for 1min (between terminals) (Detection current: 10mA.)
Insulation resistance Min. 100MΩ (between poles)
Heat resistance 150°C ±3°C 302°F ±37.4°F for 1 hour
Note: Do not insert or remove while powered on.

DIMENSIONS (mm) CAD The CAD data of the products with a “CAD” mark can be downloaded from our Website.
1 Form A and 2 Form A types
External dimensions Panel cutout
CAD
M3.5×4 screw M4×4 screw Lot No.
7.2

40
9

11
14.4
60
22

2ー4.2 dia. hole


( or 2ーM4 screw hole)
11
9

9.2

10.25 8.4 16 Relay mounting diagram


23
3

4.5dia.
34
4 70

Note: The JH1-SF( 1 Form A single side stable type) does not have receptacles (tooth rests) for
61
numbers 2, 3, 7, and 8.
The JH2-SF( 2 Form A single side stable type) does not have receptacles (tooth rests)
for numbers 7 and 8.

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー8ー © Panasonic Corporation 2019 ASCTB259E 201903
HE Relay Terminal Sockets

MOUNTING METHOD
1. Relay mounting 2. Installing to a DIN rail 3. Removing from a DIN rail

Push

Flat-head screwdriver

NOTES
1. Be careful not to drop the relay. It is 4. When fixing the terminal socket with
made of heat-hardened resin and may screws, to avoid torque damage and
break. distortion, apply torque within the
2. Be sure to tighten the screw-down ranges shown below.
terminals firmly. Loose terminals may M3.5 screws: 0.784 to 0.98 N·m (8 to 10
lead to the generation of heat. kgf·cm)
3. When the 1 Form A is used in M4 screws: 1.176 to 1.37 N·m (12 to 14
situations covered by the Japanese kgf·cm)
Electrical Appliance and Material
Control Law, the use of 5.5 mm2
cabling and 30 A current is not
allowed. Consequently, the circuit
should be less than 20 A.

Please refer to "the latest product specifications"


when designing your product.
• Requests to customers :
https://industrial.panasonic.com/ac/e/salespolicies/

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー9ー © Panasonic Corporation 2019 ASCTB259E 201903
GUIDELINES FOR POWER RELAYS AND HIGH-CAPACITY DC CUT OFF RELAYS USAGE

For cautions for use, please read “GUIDELINES FOR RELAY USAGE”.
https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp

Precautions for Coil Input


Long term current carrying Maximum allowable voltage and temperature rise
A circuit that will be carrying a current continuously for long periods Proper usage requires that the rated coil voltage be impressed on the
without relay switching operation. (circuits for emergency lamps, alarm coil. Note, however, that if a voltage greater than or equal to the
devices and error inspection that, for example, revert only during maximum continuous voltage is impressed on the coil, the coil may
malfunction and output warnings with form B contacts) Continuous, burn or its layers short due to the temperature rise. Furthermore, do
long-term current to the coil will facilitate deterioration of coil insulation not exceed the usable ambient temperature range listed in the catalog.
and characteristics due to heating of the coil itself. Operate voltage change due to coil temperature rise
For circuits such as these, please use a magnetic-hold type latching (Hot start)
relay. If you need to use a single stable relay, use a sealed type relay In DC relays, after continuous passage of current in the coil, if the
that is not easily affected by ambient conditions and make a failsafe current is turned OFF, then immediately turned ON again, due to the
circuit design that considers the possibility of contact failure or temperature rise in the coil, the pick-up voltage will become somewhat
disconnection. higher. Also, it will be the same as using it in a higher temperature
DC Coil operating power atmosphere. The resistance/temperature relationship for copper wire
Steady state DC current should be applied to the coil. The wave form is about 0.4% for 1°C, and with this ratio the coil resistance increases.
should be rectangular. If it includes ripple, the ripple factor should be That is, in order to operate of the relay, it is necessary that the voltage
less than 5%. be higher than the pick-up voltage and the pick-up voltage rises in
However, please check with the actual circuit since the electrical accordance with the increase in the resistance value. However, for
characteristics may vary. The rated coil voltage should be applied to some polarized relays, this rate of change is considerably smaller.
the coil and the set/reset pulse time of latching type relay differs for
each relays, please refer to the relay's individual specifications.
Coil connection
When connecting coils of polarized relays, please check coil polarity
(+,-) at the internal connection diagram (Schematic). If any wrong
connection is made, it may cause unexpected malfunction, like
abnormal heat, fire and so on, and circuit do not work. Avoid
impressing voltages to the set coil and reset coil at the same time.

Ambient Environment
Usage, Transport, and Storage Conditions Dew condensation
During usage, storage, or transportation, avoid locations Condensation occurs when the ambient temperature drops
subjected to direct sunlight and maintain normal temperature, suddenly from a high temperature and humidity, or the relay is
humidity and pressure conditions. suddenly transferred from a low ambient temperature to a high
Temperature/Humidity/Pressure temperature and humidity. Condensation causes the failures like
When transporting or storing relays while they are tube insulation deterioration, wire disconnection and rust etc.
packaged, there are cases the temperature may differ from the Panasonic Corporation does not guarantee the failures caused
allowable range. In this case be sure to check the individual by condensation.
specifications. Also allowable humidity level is influenced by The heat conduction by the equipment may accelerate the
temperature, please check charts shown below and use relays cooling of device itself, and the condensation may occur.
within mentioned conditions. (Allowable temperature values Please conduct product evaluations in the worst condition of
differ for each relays, please refer to the relay's individual the actual usage. (Special attention should be paid when high
specifications.) temperature heating parts are close to the device. Also please
consider the condensation may occur inside of the device.)
Icing
1) Temperature:
The tolerance temperature range differs for each relays, Condensation or other moisture may freeze on relays when the
please refer to the relay’s individual specifications temperature become lower than 0°C.This icing causes the sticking of
2) Humidity: movable portion, the operation delay and the contact conduction failure
5 to 85 % RH etc. Panasonic Corporation does not guarantee the failures caused by
3) Pressure: the icing.
86 to 106 kPa
The heat conduction by the equipment may accelerate the cooling of
relay itself and the icing may occur. Please conduct product
Humidity, %R.H.
evaluations in the worst condition of the actual usage.
Low temperature and low humidity
85
The plastic becomes brittle if the switch is exposed to a low
Allowable range
temperature, low humidity environment for long periods of time.
(Avoid
(Avoid icing
condensation High temperature and high humidity
when used at
temperatures when used at Storage for extended periods of time (including transportation periods)
temperatures
lower than 0°C) higher than at high temperature or high humidity levels or in atmospheres with
0°C)
5 organic gases or sulfide gases may cause a sulfide film or oxide film to
–40 0 85 form on the surfaces of the contacts and/or it may interfere with the
Ambient temperature, °
C
functions. Check out the atmosphere in which the units are to be
stored and transported.

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー 10 ー c Panasonic Corporation 2019 ASCTB412E 201903
GUIDELINES FOR POWER RELAYS AND HIGH-CAPACITY DC CUT OFF RELAYS USAGE
Package NOx Generation
In terms of the packing format used, make every effort to keep the When relay is used in an atmosphere high in humidity to switch a load
effects of moisture, organic gases and sulfide gases to the absolute which easily produces an arc, the NOx created by the arc and the
minimum. water absorbed from outside the relay combine to produce nitric acid.
Silicon This corrodes the internal metal parts and adversely affects operation.
When a source of silicone substances (silicone rubber, silicone oil, Avoid use at an ambient humidity of 85%RH or higher (at 20°C). If use
silicone coating materials and silicone filling materials etc.) is used at high humidity is unavoidable, please contact our sales
around the relay, the silicone gas (low molecular siloxane etc.) may be representative.
produced.
This silicone gas may penetrate into the inside of the relay. When the
relay is kept and used in this condition, silicone compound may adhere
to the relay contacts which may cause the contact failure. Do not use
any sources of silicone gas around the relay (Including plastic seal
types).

Others
Cleaning
1) Although the environmentally sealed type relay (plastic sealed type,
etc.) can be cleaned, avoid immersing the relay into cold liquid (such
as cleaning solvent) immediately after soldering. Doing so may
deteriorate the sealing performance.
2) Cleaning with the boiling method is recommended(The temperature
of cleaning liquid should be 40°C or lower ).
Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may
cause breaks in the coil or slight sticking of the contacts due to
ultrasonic energy.

Please refer to "the latest product specifications"


when designing your product.
•Requests to customers:
https://industrial.panasonic.com/ac/e/salespolicies/

Panasonic Corporation Electromechanical Control Business Division


industrial.panasonic.com/ac/e/ ー 11 ー c Panasonic Corporation 2019 ASCTB412E 201903
2019

ASCTB183E-1 201903

You might also like