BOP CONTROL SYSTEM ACCEPTANCE METHOD
Pág. 1 de 5
Accepted
Date:
by:
ACCEPTANCE METHOD
Sistema Integrado de Gestão de Saúde, Segurança, Meio Ambiente, Qualidade e Responsabilidade Social - IMS Pág. 1 de 5
Air Supply Set To 75psi. YES FORMULÁRIO FORM-125-COM
Setembro/17
Full Working Pressure BOP CONTROL SYSTEM ACCEPTANCE METHOD
YES Pág. 2 de 5
Achieved.
Accepted by:
Date:
ACCEPTANCE METHOD
3.1
3.2
3.3
4.1
Bleed the system down to below 90% of full working pressure, take note at
what pressure the primary pump (electric) starts
Isolate the electric pump, bleed down to below 85% of full working pressure,
4.3
Calculate 85% of full working pressure 2550
Sistema Integrado de Gestão de Saúde, Segurança, Meio Ambiente, Qualidade e Responsabilidade Social - IMS Pág. 2 de 5
TIME:
Annular: Size: 13 5/8”
Shear Rams:
Variable Rams: FORMULÁRIO FORM-125-COM
HRC (Choke) Valve:
Setembro/17
BOP CONTROL SYSTEM ACCEPTANCE METHOD
Pág. 3 de 5
Secondary Pump (Air) Cuts in at: 2700
Accepted
Date:
by:
ACCEPTANCE METHOD
Check that the secondary pump (air) alone will pump the system up to full
working pressure with the air supply to the pumps set at 75psi.
Put the air supply back to normal and adjust the cut out for the air pump to
cut out at not less than 90% of full working pressure and test
Verify that the combined output of both primary pump (electric) and
secondary pumps (air) should be able to pump up the entire system from
zero psi to full working pressure in not more than 15 minutes.
4.5 As per API RP16D.2.2.1.3
Time To Pump To Full Working Pressure 6min.30Sec
Isolate the fully pressured up Accumulator unit from the BOP Stack and
check that the pressure does not drop for minimum of 5 minutes.
4.6
System Pressure Holds: Yes: No:
Check the BOP response time by operating each BOP Ram sets and the
Annular BOP and recording the time between operating the valve and BOP
4.7
fully closed. (Annular BOP’s smaller than 18 ¾ and all ram type BOP’s = 30
seconds max, Annular BOP’s 18 ¾ and larger = 45 seconds max)
4.8
Sistema Integrado de Gestão de Saúde, Segurança, Meio Ambiente, Qualidade e Responsabilidade Social - IMS Pág. 3 de 5
FORMULÁRIO FORM-125-COM
Setembro/17
BOP CONTROL SYSTEM ACCEPTANCE METHOD
Pág. 4 de 5
Verify that the accumulator bottle set has enough fluid to close the annular
BOP and all ram type BOP’s (from fully open to fully closed) and open one
HCR valve against zero well bore pressure, after which there should be not
less than 200psi above the nitrogen pre-charge pressure as per API
4.11 RP53.12.3.2
Pressure left in the System after the test
Accepted by:
Date: