TECHNOLOGY TO THE FORE

SWITCHGEAR COMPLEX

CG Switchgear and Control


A Business Unit of Crompton Greaves Ltd. PRODUCT RANGE
TECHNOLOGY TO THE FORE

EQUIPMENTS FOR OUTDOOR SUBSTATION:


A) CIRCUIT BREAKERS
SWITC H G EAR 1) SF6 GAS CIRCUIT BREAKERS
C O M P L E X

SNo TYPE RATED INSULATION FAULT / NORMAL RATED


REF. VOLTAGE (kV) LEVEL (kV / kVp) CURRENT (kA) / A OPERATING SEQUENCE

SPRING CLOSING - SPRING TRIPPING


1 SFGP 24 50 / 125 25 / 1250 / 2000 O-0.3 Sec-CO-15 Sec-CO /
CO-15 Sec- CO
2 SFGP 36 70 / 170 25 / 1250 / 2000 - do -
80 / 200 40 / 1250 / 2000
3 SFM 72.5 140 / 325 31.5 / 3150 O-0.3 Sec-CO-3 Min-CO /
CO-15 Sec-CO
4 SFM 123 230 / 550 31.5 / 3150 - do -
5 SFM 145 275 / 650 31.5 / 3150 - do -
6 SFM 245 460 / 1050 40 / 3150 - do -
7 SFM 52 95 / 250 8 / 800 - do -
8 SFM 52 95 / 250 20 / 1600 - do -
SPRING CLOSING - PNEUMATIC TRIPPING
9 SFM 25-1 Pole 95 / 250 31.5 / 3150 O-0.3 Sec-CO-3 Min-CO /
CO-15 Sec-CO
10 SFM 72.5 140 / 325 31.5 / 3150 - do -
40 / 3150
11 SFM 123 230 / 550 31.5 / 3150 - do -
40 / 3150
12 SFM 145 275 / 650 31.5 / 3150 - do -
40 / 3150
13 SFM 170 325 / 750 31.5 / 3150 - do -
14 SFM 245 460 / 1050 40 / 3150 - do -
15 SFM 420 630 / 1425 / 1050 40 / 3150 - do -
STD VALUE OF CREEPAGE IS 25 mm/kV
Non STD Creepage is also Available
Approvals : CESI - ITALY, KEMA - NETHERLANDS, CPRI - INDIA
Standards : IEC 56 - 1987 : ANSI C37.09 - 1979

2) VACUUM CIRCUIT BREAKERS

SNo TYPE RATED INSULATION FAULT / NORMAL RATED


REF. VOLTAGE (V) LEVEL (kV / kVp) CURRENT (kA) / A OPERATING SEQUENCE

1 12PVE12 12 28 / 75 13.1 / 800 Spring Closing / Tripping


O-0.3 Sec-CO-3 Min-CO

2 12PVE20 12 28 / 75 26.3 / 1250 - do -


XL

3 12PVE20 12 28 / 75 26.3 / 1600 - do -


XL

4 36PV25A 36 70 / 170 25 / 1250, 2000 - do -

STD VALUE OF CREEPAGE IS 25 mm/kV


Approvals : CPRI - India
Standards : IEC 56 - 1987
TECHNOLOGY TO THE FORE

B) INSTRUMENT TRANSFORMERS
1) CURRENT TRANSFORMERS SW ITCHGEAR
C O M P L E X

SNo TYPE RATED INSULATION* RATED* SECONDARY NO. OF* STR*


VOLTAGE(kV) LEVEL (kV/kVp) CURRENT (A) CURRENT (A) CORES kA / Sec

(a) LIVE TANK TYPE


1 CGC 24 50 / 125 50 - 2500 1 OR 5 3 25 / 1, 3
2 CGC 36 70 / 170 50 - 2500 1 OR 5 3 25 / 1, 3
3 CT 52 95 / 250 50 - 2500 1 OR 5 3 31.5 / 1, 3
4 CT 72.5 140 / 325 50 - 2500 1 OR 5 3 31.5 / 1, 3
5 IOSK 123 230 / 550 50 - 2500 1 OR 5 5 40 / 1, 3
6 IOSK 145 275 / 650 50 - 2500 1 OR 5 5 40 / 1, 3
7 IOSK 170 325 / 750 50 - 2500 1 OR 5 5 40 / 1, 3
8 IOSK 245 460 / 1050 50 - 2500 1 OR 5 5 40 / 1, 3
9 IOSK 420 630 / 1425 50 - 2500 1 OR 5 5 40 / 1, 3
& 1050
(b) DEAD TANK TYPE
1 IOSS 123 230 / 550 50 - 800 1 OR 5 5 25 / 1
2 IOSS 145 275 / 650 50 - 800 1 OR 5 5 25 / 1
*THE ABOVE ARE TYPICAL VALUES.
OTHER SPECS. ARE ALSO FEASIBLE.
STD. VALUE OF CREEPAGE IS 25 mm/kV
Approvals : KEMA - Netherlands, CPRI - India
Standards : IEC 44-1 - 1996 (Formerly IEC 185 - 1987),
ANSI C57.13 - 1978.

2) CAPACITIVE VOLTAGE TRANSFORMERS

SNo TYPE RATED INSULATION* RATED* SECONDARY* NO. OF* SIMUL


VOLTAGE (kV) LEVEL (kV / kVp) CAP (pF) VOLTAGE (V) SEC WDG BURDEN**
/CLASS
1 CVE 72.5 140 / 325 4400 100, 110, 120, 3 150 VA
100, 110, 120, / 0.5
√3 √3 √3
2 CVE 145 140 / 325 4400 100, 110, 120, 3 200 VA
100, 110, 120, / 0.5
√3 √3 √3
3 CVE 170 325 / 750 4400 100, 110, 120, 3 200 VA
100, 110, 120, / 0.5
√3 √3 √3
4 CVE 245 460 / 1050 8800 100, 110, 120, 3 200 VA
100, 110, 120, / 0.5
√3 √3 √3
5 CVE 420 630 / 1425 8800 100, 110, 120, 3 300 VA
& 1050 100, 110, 120, / 0.5
√3 √3 √3
*THE ABOVE ARE TYPICAL VALUES. OTHER SPECS. ARE ALSO FEASIBLE.
**THIS VALUE DEPENDS ON THE CAPACITANCE.
STD. VALUE OF CREEPAGE IS 25 mm/kV
Approvals : CPRI - India
Standards : IEC 186 - 1987, ANSI C57.13 - 1978.
TECHNOLOGY TO THE FORE

EQUIPMENTS FOR OUTDOOR SUBSTATION:


B) INSTRUMENT TRANSFORMERS
SWITC H G EAR 3) INDUCTIVE VOLTAGE TRANSFORMERS
C O M P L E X

SNo TYPE RATED INSULATION* SECONDARY* NO. OF* SIMULTANEOUS*


VOLTAGE (kV) LEVEL (kV / kVp) VOLTAGE (V) SEC WDG BURDEN/CLASS

1 CGV 24 50 / 125 100, 110, 120, 3 120 VA / 0.5


100, 110, 120,
√3 √3 √3
2 CGV 36 70 / 170 100, 110, 120, 3 200 VA / 0.5
100, 110, 120,
√3 √3 √3
3 CGV 52 95 / 250 100, 110, 120, 3 200 VA / 0.5
100, 110, 120,
√3 √3 √3
4 IVT 72.5 140 / 325 100 110 120 3 200 VA / 0.5
100, 110, 120,
√3 √3 √3
5 VEOT 123 230 / 550 100, 110, 120, 3 500 VA / 0.5
100, 110, 120,
√3 √3 √3
6 VEOT 145 275 / 650 100, 110, 120, 3 500 VA / 0.5
100, 110, 120,
√3 √3 √3
7 VEOT 245 460 / 1050 100, 110, 120, 3 500 VA / 0.5
100, 110, 120,
√3 √3 √3
*THE ABOVE ARE TYPICAL VALUES.
OTHER SPECS. ARE ALSO FEASIBLE.
STD. VALUE OF CREEPAGE IS 25 mm/kV
Approvals : CPRI - India.
Standards : IEC 186 - 1987, ANSI C93.1, 1990.

C) SURGE ARRESTERS

SNo TYPE REF RATED* SYSTEM INSULATION NDC (kA) ENERGY LIRV AT NDC,
VOLTAGE (kV) VOLTAGE (kV) LEVEL (kV/kVp) CLASS 8/20 MICRO
SEC (kVp)

1 ZYP D 31 9 12 28 / 75 5 DIST 32
2 ZLA X 15C 9 12 28 / 75 10 2 28
3 ZLA X 15C 9 12 28 / 75 10 3 25
4 ZYA D 31 18 24 50 / 125 5 DIST 64
5 ZLA X 15C 18 24 50 / 125 10 2 56
6 ZLA X 15C 30 36 70 / 170 10 2 90
7 ZLA X 15C 60 72.5 140 / 325 10 2 180
8 ZLA X 25C 30 36 70 / 170 10 3 84
9 ZLA X 25C 60 72.5 140 / 325 10 3 170
10 ZLA X 25C 96 123 230 / 550 10 3 272
11 ZLA X 25C 120 145 275 / 650 10 / 20 3/4 320 / 340
12 ZLA X 25C 198 / 216 245 460 / 1050 10 / 20 3/4 550-575 /
600-620
13 ZLA X 25C 390 420 630 / 1425 10 / 20 3/4 950 / 975
& 1050
*FOR SOLIDLY EARTHED SYSTEMS.
OTHER SPECS. (INCLUDING LV) ARE ALSO FEASIBLE.
STD. VALUE OF CREEPAGE IS 25 mm/kV
Approvals : CPRI - India : CESI - ITALY
Standards : IEC 99 - 4, 1991
TECHNOLOGY TO THE FORE

D) TRANSFORMER BUSHINGS SW ITCHGEAR


C O M P L E X

SNo TYPE RATED INSULATION* CURRENT* CT PROVISION* CONDUCTOR


VOLTAGE (kV) LEVEL (kV/kVp) (A) BCT (mm) ARRANGEMENT

1 CHL - 250 52 105 / 250 800 100,300,600 Draw Rod


2 CHS - 250 52 105 / 250 1250 100,300,600 Draw Rod
3 CHT - 250 52 105 / 250 2000 100,300,600 Solid Stem
4 CHT - 250 52 105 / 250 3150 100,300,600 Solid Stem
5 CHL - 325 72.5 140 / 325 800 100,300,600 Draw Rod
6 CHS - 325 72.5 140 / 325 1250 100,300,600 Draw Rod
7 CHL - 650 145 275 / 650 800 100,300,600 Draw Rod
8 CHS - 650 145 275 / 650 1250 100,300,600 Draw Rod
9 CHT - 650 145 275 / 650 2000 300,600 Solid Stem
10 CHL - 1050 245 460 / 1050 800 100,300,600 Draw Lead
11 CHS - 1050 245 460 / 1050 1250 100,300,600 Draw Rod
12 CHT - 1050 245 460 / 1050 2000 100,300,600 Solid Stem
13 CHL - 1425 420 630/1425/1050 800 400 Draw Lead
14 CHS - 1425 420 630/1425/1050 1250 400 Draw Lead

SN TYPE RATED INSULATION CURRENT CT PROVISION CONDUCTOR


VOLTAGE (kV) LEVEL (kV/kVp) (A) BCT (mm) ARRANGEMENT
1 CHC - 125 24 55 / 125 4000- - Stem
12500
*THE ABOVE ARE TYPICAL VALUES.
OTHER SPECS. ARE ALSO FEASIBLE.
STD. VALUE OF CREEPAGE IS 25 mm/kV
Approvals : In House Tested
Standards : IEC 137 - 1984

E) ON LOAD TAP CHANGERS


SNo TYPE VOLTAGE / CURRENT STEP TAP POSITION / POWER
INSULATION (A) VOLTAGE (V) ARRANGMENT FLOW
LEVEL
(kV / kVp PE)

1(a) AT - 44 44 / 250 300 1000 18 - Linear / Full Bi-directional


33 - Changeover
(b) AT - 150 N 132 NE / 250 300 1400 18 - Linear / Full Bi-directional
33 - Changeover
2(a) AT - 44 44 / 250 400 1000 18 - Linear Full Bi-directional
(b) AT - 150 N 132 NE / 250 400 1400 18 - Linear Full Bi-directional
3(a) AT - 66 72.5 / 350 300 1000 18 - Linear / Full Bi-directional
33 - Changeover
(b) AT - 66 72.5 / 350 400 1000 18 - Linear Full Bi-directional
4 F - 33 36 / 200 200 / 300 1250 / 625 17 - Linear Restricted Reverse
5 F - 66 72.5 / 350 200 / 300 1250 / 625 17 - Linear Restricted Reverse

*OTHER SPECIFICATIONS ARE ALSO FEASIBLE


Approvals : CPRI - India
Standards : IEC 214 - 1989
TECHNOLOGY TO THE FORE

SWITC H G EAR
C O M P L E X
EQUIPMENT FOR INDOOR SUBSTATIONS:
A) CIRCUIT BREAKERS
1) VACUUM CIRCUIT BREAKERS

SNo TYPE RATED INSULATION FAULT / NORMAL OPERATING MECHANISM


REF. VOLTAGE (kV) LEVEL (kV/kVp) CURRENT (kA) / A /RATED OPERATING SEQUENCE

1 12VE12 12 28 / 75 13.1 / 800 Spring Closing / Tripping


O-0.3 Sec-CO-3 Min-CO /
CO-15 Sec-CO
2 12V12 XL 12 28 / 75 20 / 800, 1250 - do -
3 12V20 12 28 / 75 26.3 / 800, 1250, - do -
1600
4 12VE20 12 28 / 75 26.3 / 800, 1250 - do -
5. 12VE40 12 28 / 75 40 / 800, 1250 - do -
6. 12VX20 12 28 / 75 26.3 / 1600 - do -
7. 12VX40 12 28 / 75 40 / 1600, 2500 - do -
3150
8. 12VE20 15 38 / 95 25 / 630, 1250 - do -
9. 12VX20 15 38 / 95 25 / 1600, 2000 - do -

Approvals : KEMA - Netherlands : CPRI - India


Standards : IEC - 56

1) SF6 GAS CIRCUIT BREAKERS

SNo TYPE RATED INSULATION FAULT/NORMAL OPERATING MECHANISM /


REF. VOLTAGE (kV) LEVEL (kV/kVp) CURRENT (kA) / A RATED OPERATING SEQUENCE

1 SFG 7.2 22 / 60 40 / 1250, 2000, Spring Closing / Tripping


3150 O-3 min-CO-3 min-CO

2 SFG 12 28 / 75 - do - Spring Closing / Tripping


O-0.3 Sec-CO-3 min-CO

3. SFG 36 70 / 170 25 / 1250, 2000 - do -

Approvals : CPRI - India


Standards : IEC - 56 1987 / IEC 298 -1980
TECHNOLOGY TO THE FORE

B) INDOOR SWITCHBOARD
SW ITCHGEAR
1) VACUUM SWITCHBOARD C O M P L E X

SNo TYPE RATED INSULATION FAULT / NORMAL DIMENSIONS


REF. VOLTAGE (kV) LEVEL (kV/kVp) CURRENT (kA) / A (W × H × D) mm

1 UNIVAC 12 28 / 75 13.1 - 26.3 / 1250 705 × 1875 × 1825


2 UNIVAC 12 28 / 75 13.1 - 26.3 / 1600 855 × 1875 × 2140
3 COMPAC 12 28 / 75 26.3 - 40 / 1250 650 × 2200 × 1572
4 COMPAC 12 28 / 75 26.3 - 40 / 2000 800 × 2200 × 1572
5 JV 12 28 / 75 13.1 - 25 / 150 650 × 2000 × 1760
15 38 / 95
6 JV 12 28 / 75 13.1 - 25 / 1600, 2000 800 × 2000 × 1760
15 38 / 95
Approvals : KEMA - Netherlands : CPRI - India
Standards : IEC 56 - 1987 / IEC 298 - 1980

2) SF6 GAS SWITCHBOARD

SNo TYPE RATED INSULATION FAULT / NORMAL DIMENSIONS


REF. VOLTAGE (kV) LEVEL (kV/kVp) CURRENT (kA) / A (W × H × D) mm

1 EX 3.6 / 7.2 10 / 40 : 20 / 60 40 / 1250 700 × 2300 × 2300


2 EX 3.6 / 7.2 10 / 40 : 20 / 60 40 / 3150 1000 × 2500 × 2300
3 CGEX 36 70 / 170 25 / 1250, 2000 1300 × 2066 × 3130

Approvals : CPRI - India


Standards : IEC 56

3) OIL SWITCHBOARD

SNo TYPE RATED INSULATION FAULT / NORMAL DIMENSIONS


REF. VOLTAGE (kV) LEVEL (kV/kVp) CURRENT (kA) / A (W × H × D) mm

1 ALA1 / XL 12 28 / 75 18.4 / 1250 572× 1930 × 1750

Approvals : CPRI - India


Standards : IEC 56
CG Switchgear and Control
A Business Unit of Crompton Greaves Ltd.
Switchgear Complex
A-3, MIDC, Ambad, Nashik - 422 010 India
Tel: (+91) 253 382271 Ext 107/108/110
Fax: (+91) 253 382219/381247
E-mail: exports@cglmail.com (Exports)
mktg@cglmail.com (General)
URL: www.cgswgear.com
Regd. Office : The Thapar Group
6th Floor, CG House, Dr. Annie Besant Road,
Prabhadevi, Mumbai - 400 025, India. Data subject to change
CG-S&C/EXP/Cat.No.100/3/01/3000