Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

F F

PSV UNF 6 B 1/300-5


-A1 L 160/160/E0C/UNF 5 AN280 BN280
-ZPL 531
-A2 L 10/10/E0C/UNF 3 AN280 BN280
-A2 L 63/63 A200 B200 S1UNF/E0C/UNF 3 AN210 BN210
-A2 O 63/63 A200 B200/E0C/UNF 3 ANBN
-A1 O 25/25/E0C/UNF 3
-A5 O 80/80/E0C/UNF 3 ANBN
-A5 O 80/80/E0C/UNF 3 ANBN
-E 4 UNF

A B A B A B

E A B A B A B A B E
280 bar 280 bar 210 bar

280 bar 280 bar 210 bar

Z A B R A B R A B R A B R A B R A B R A B R

20 bar
M

b b b b b b b

D D

300 bar

a a a a a a a

DW

LS
C T C
Z
P

P LS R T R

W/1 U/2

BLOQUE DE CONEXIÓN AVANCE RÁPIDO AVANCE FINO WINCHE BOMBA DE AGUA INCLINACIÓN ROTACIÓN 1 ROTACIÓN 2

For variable displacement pump A, B: 7/8-14 UNF A, B: 7/8-14 UNF A, B: 7/8-14 UNF A, B: 7/8-14 UNF A, B: 7/8-14 UNF A, B: 7/8-14 UNF A, B: 7/8-14 UNF
Q max = 300 l/min Closed center spool Closed center spool Closed center spool Open center spool with return flow throttling Open center spool with return flow throttling Open center spool with return flow throttling Open center spool with return flow throttling
P max = 400 bar Without flow compensator With flow compensator (6 bar) With flow compensator (6 bar) With flow compensator (6 bar) Without flow compensator With flow compensator (9 bar) With flow compensator (9 bar)
P,R: 1 5/8-12 UNF QA = 160 l/min (*) QA = 10 l/min QA = 63 l/min QA = 63 l/min QA = 25 l/min (*) QA = 107 l/min QA = 107 l/min
LS, Z, M, DW: 7/16-20 UNF QB = 160 l/min (*) QB = 10 l/min QB = 63 l/min QB = 63 l/min QB = 25 l/min (*) QB = 107 l/min QB = 107 l/min
Pressure limitation = 300 bar Shock and anticavitation valves in A and B (280 bar) Shock and anticavitation valves in A and B (280 bar) LS Pressure limitation: LSA = 200 bar ; LSB = 200 bar LS Pressure limitation: LSA = 200 bar ; LSB = 200 bar Manual actuation with detent (prepared for electric) Anticavitation valves in A and B Anticavitation valves in A and B
Pressure reduction = 20 bar Manual actuation with detent (prepared for electric) Manual actuation with detent (prepared for electric) Shock and anticavitation valves in A and B (210 bar) Anticavitation valves in A and B (*) Flow up to 34 l/min increasing dp Manual actuation with detent (prepared for electric) Manual actuation with detent (prepared for electric)
LS dampening oriffice 0,8 mm (*) Flow up to 210 l/min increasing dp LS A and B external ports (W1, U2) Manual actuation with detent (prepared for electric)
Manual actuation with detent (prepared for electric)

B B

A A

Customer Dimension
Part number
HAWE Hidráulica SLU drawn by MascaroO MAQ. POWER 1:1
PSV-5
26/04/2021 Project description
C/ Del Progrés, 139-141
Project name
Perforadora Diamantina H-400 MAQ.Power
08940 (BCN)Cornellà de Llobregat Modification date 26/04/2021
Day Name Checked Index Notice of revision
Fluid power schematic
CAD-Drawing: Modification only by electronic data processing A1

You might also like