2922-GAC-STA-DAS-000-1039 - B D4001 Column Top Condenser XE4001 - TR-59
2922-GAC-STA-DAS-000-1039 - B D4001 Column Top Condenser XE4001 - TR-59
PRODUCTION FACILITY
Global Amine Company , Pte, Ltd PT. Tripatra Engineering
MECHANICAL DATASHEET
for
D4001 COLUMN TOP CONDENSER
XE4001
Document No.
2922-GAC-STA-DAS-000-1039
2922-GAC-STA-DAS-000-1039 Page 2 of 6
MECHANICAL DATA SHEET Doc no.
N18
N2
NOZZLE SCHEDULE
MARK QTY SIZE RATING FACE TYPE PROJECTION SERVICE REMARKS
N1 1 4" 150# RF WN (*) BFW Inlet
N2 1 4" 150# RF WN (*) LPS Outlet
N18 1 10" 150# RF WN (*) Vapor Outlet Part of D4001
N2 1 3" 150# RF WN (*) Liquid Outlet Part of D4001
MECHANICAL DATA SHEET DOC. NO. :
3 Vendor shall responsible for detailed engineering of the heat exchanger. Vendor to confirm that fabrication, inspection and testing shall follow the
4 Gasket for Girth Flange: 4.5 mm thick Flexitallic Style CGI, SPW, Graphite Filled, 316L SS Windings
Gasket for Nozzle: 4.5mm, SPW 316L SS, Graphite Filled, 316L SS inner & outer ring, ASME B16.20/B16.5
Intermediate : -
7 All metallic material shall be provided with inspection certificate in accordance with BS EN 10204 latest edition, pressure parts
8 All external nozzles locallized stress analysis to be performed by Vendor as per WRC 107 & 297 Bulletin.
9 Nozzles location and orientation shall be verified by Supplier of internal part and EPC Contractor prior to fabrication.
Vendor shall inform and verify actual weight, shear & moment data information and by calculation.
11 Vendor shall be responsible for the full thermal & mechanical design and shall confirm all material chosen
12 Vendor shall provide weight detail calculations and general assembly drawing including foundation loading data, center of gravity for each Cases
14 Nozzle load
FA FL FC MT ML MC
Nozzle Size
Kgf Kgf Kgf Kgf.m Kgf.m Kgf.m
N1, N2 4" 150# 600 600 450 180 156 120