Draeger Controllers: REGARD 3920 Regard

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 44

Draeger Controllers

REGARD 3920 REGARD

DRAEGERGARD 8/16 DRAEGERGARD PLUS


PLC CONTROL SYSTEM

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 4 /73
UPGRADING EXSISTING CO DETECTION SYSTEM IN
STEEL PLANT

AB PLC+WIRELESS
+ TOUCH PANEL

ETHERNET/IP
HARD-WIRING
+WIRELESS

EXISTING DETECTORS 42” TV MONITOR


+ NEW DETECTORS

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 5 /73
SEQUENTIAL SAMPLING SYSTEM

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 6 /73
WIRELESS APPLICATIONS
Point to Multi-Point

Node 2 Node 46

Node 47

Node 1
Gateway

RS485(Modbus RTU)
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 7 /73
APPLICATIONS
Wireless Transmitters Powered By Solar System

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 8 /73
APPLICATIONS
Wireless Transmitters

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 9 /73
REGARD 3920
PRODUCT OVERVIEW

LCD IP65
Display Enclosure

Operation
Buttons
System
Status
LEDs

Allen bolt
Channel
Status
LEDs

11 | 18 REGARD 3900 | Gavin Peacock | 22.01.2010


REGARD 3920
PRODUCT OVERVIEW

• Options for Inputs & Outputs

• 1 input board + 2 relay boards (max)

• 2 input boards + 2 relay boards

• 3 input boards + 1 relay board

• 4 input boards & no relay boards

• In addition to the above

• 2 repeat output boards

There can never be more than 4 Input and Relay boards installed

12 | 18 REGARD 3900 | Gavin Peacock | 22.01.2010


Regard 3920
Regard 3920
Control System
Regard

• Central control system

• Multiple input and output options

• 99 Input channels per system

• Simple I/O distribution

• PC and pushbutton configuration

• Flexible
• The Master Card communicates over the internal
BUS with the Channel Card (Slaves) and controls
the Channel Cards in the System.
• The 3 relays on the master card can be cofigured
as either master alarms or voting alarms wrt all
the other cards in the system.
• Input for remote reset.
• Additional Master cards (extra Master) provide
extra relay configurations.
• A 4-digit Display shows the functions when the
pushbuttons are used to configure Gasname,
device and Measuring range of all Channel Cards,
confirmation and configuration.
• 6 Led´s for Status display (Alarm,
• ATEX Certificate !! troubleshooting....)
• Master control of slave card readings and settings.
• Master acknlowledgement of system status.
• The 4..20mA Channel Card is for all 4..20mA
Transmitters (P3000, P7000, PIR7000...).

• 3 Alarm relays A1,A2, A3/Fault.

• Input for remote reset.

• A 4-digit Display shows the gas concentration and


functions when the pushbuttons are used to
configure Gasname, device and Measuring range
of all Channel Cards, confirmation and
configuration.

• 6 Led´s for Status display (Alarm,


• ATEX Certificate !! Troubleshooting....)

• Analogue Output 4-20mA and 0-20mA.


• ATEX Certificate !

• 8-Way Channel Card


• All 2-/3-wire 4..20mA associated transmitters.
• 3 Alarm relays A1,A2, A3/Fault common for all 8 channels.
• Input for remote reset.
• Display Card and 8-channel module utilising RS485 (max 1000m).
• A multi digit display for the Gas readings of Transmitters. Functions
available on the frontplate for setting display of Gas name, Measuring range
and for Configuration.
• 6 Led´s for Status display (Alarm, Troubleshooting....)
• The 4..20mA Module is Standard rack mounting. The module can be field
mounted.
• Master-Card
required!

• ATEX Certificate !
• The Relay Display Card can control 16 Relay modules maximum (256
Relays).
• Relay-Display Card and the Relay modules communicate over RS-485.
• 1 Fault relay and input for remote reset.
• Relay-Display card and Relay module utilising RS485 (max 1000m).
• The multi digit display shows the status of all the relays.
• Functions available on the frontplate for setting alarm types and
configuration.
• Led´s for Status display (Alarm, Troubleshooting.......)
• The Relay module contains 16 Relays, configured for Single, Group or
Voting alarm outputs A1, A2, A3 / Fault configuration.
• The Relay display card is Standard rack mounting. The module can be field
mounted.
• Modbus-gateway for connection in the frame system
for Draeger Visualisation-Software „Vision32“.

• To show Gas concentrations and the Status of alarms


and Faults.

• Additional information of warnings and criticcal card


faults.

• Comes with RS232, 422 and 485 Gateway.

• A 4-digit Display for Configuration and Test.

• Pushbuttons on the front panel for configuration.

• Master-Card Required!
• The Optical Card is for operation with the optical
Transmitters: Polytron IR and Pulsar.

• 4 Alarm relays A1,A2, A3/Fault, „Beam-Block


Warning“
and 1 Transistor-output for „Beam-Block“.

• Input for remote reset.

• A 4-digit Display shows the gas concentration and


functions when the pushbuttons are used to configure
Gasname, device and Measuring range of all
Channel Cards, confirmation and configuration.

• ATEX Certificate !! • 6 Led´s for Status display (Alarm,


Troubleshooting....)

• Analogue output 4-20mA und 0-20mA.


Regard
DRAEGERGARD 8/16

COMPACT 16-CHANNEL CONTROLLERS

DRAEGERGARD REGARD 3920

4~20mA INPUT RELAY OUTPUT

UP TO 16 TRANSMITTERS
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 35 /73
DraegerGard 8/16

With Touch Screen Panel

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 36 /73
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16

NEMA 7 ENCLOSURE
DraegerGard 8/16
DraegerGard 8/16
Agenda

Draeger Controllers

1. OVERVIEW
2. REGARD 3920
3. REGARD
4. DRAEGERGARD 8/16
5. DRAEGERGARD PLUS
DraegerGard Plus

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 51 /73
½ inch and Full Length NEMA 7
Compact NEMA 4X NEMA 4X Fiberglass
19 inch Aluminum Wall
Fiberglass Wall Mount
Rack/Panel Mount Mount
Wall Mount

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 52 /73
MENU SCREEN

MAIN DATA
SCREEN

BAR GRAPH
SCREEN

TREND SCREEN

COMBINATION
SCREEN

ZONE SCREEN

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 53 /73
Channel configurations include 16, 32, 48 and 64 (shown) active channels

Indicates alarm status by cell color

Flashing color becomes steady after acknowledge

Displays measurement name, bar graph, engineering units and scaled value

View all active channels on the same screen

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 54 /73
View 16 channels at a time

Displays channel number, bar graph, alarm levels, current reading and engineering
units

Changes in bar graph colors indicate alarm status

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 55 /73
View one channel’s 24 hour trend

Top color bar changes with alarm level

Top data fields include current reading, min - max - average readings over the 24 hours, range, channel
number,
measurement name and Engineering Units

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 56 /73
16, 32, 48, 64 Channel
Graphic Display & Alarm Controller
Ch 0 7 Me a s u r e me n t N a me
! P CT L E L
2 4 0 0 Co u n t s 50 Alarm
* DO NOT REMOVE Menu
WHEN LED IS ON Mi n : 0 Ma x : 9 5 Av g : 3 2 Reset

Zer o:0 S p a n : 10 0
10 0 2 7 24 21 18 15 12 9 6 3m

SD Card
80 Next Edit

60

40

20

Serial No. Standard Standard Standard Fault Horn


Relay 1 Relay 2 Relay 3 Relay Relay
72-1020

Upload/download system configuration via SD card

Logged data saves to SD Card

Holds over one year of data at logging rate of every one minute with 2 GB SD Card

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 57 /73
Ethernet web server allows backup and restore of
system configuration

Web page interface allows remote configuration

View real-time data

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 58 /73
DraegerGard Plus
Agenda

Draeger Controllers

1. OVERVIEW
2. REGARD 3920
3. REGARD
4. DRAEGERGARD 8/16
5. DRAEGERGARD PLUS
6. VISION 7000
VISION 7000

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 61 /73
VISION 7000

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 62 /73
VISION 7000

GAS CONCENTRATION

LAYOUT

BAR GRAGH

REAL TIME TRENDING

DATA LOGGING

HISTORICAL TRENDING

ALARMING

……

DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON


JAN, 2013• 63 /73
VISION 7000