Layout Kubikel Sirimau Pix Schneider - Po110-201 - 01

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

1 2 3 4 5 6 7 8

A A

GI SIRIMAU
B B

C C

D D
Confidential and Copyright Property of Schneider Electric

RN RN UP Update as per comments (18/02/2011)
01
23/02/2011 23/02/2011 23/02/2011
BWP RN UP First Issued
00
28/12/2010 28/12/2010 28/12/2010
E Drawn by Checked by Approved by E
Revision N° Modification
date date date

Customer PT. BINA ENERGI SELARAS Order N° M30178­EN1

Customer project reference Switchboard 24 kV Switchgear

Title Single Line Diagram and General Arrangement Panel

PT SCHNEIDER Revision N° 01
Document type Cover sheet
F INDONESIA F

Scale Format Drawing number PO110­201 page number


A3 001/ 011
Sheet name COV_01
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Page Sheet Page Sheet


Revision N° Sheet Tittle Description Revision N° Sheet Tittle Description
Number Name Number Name

001 COV_01 01 Cover Sheet Single Line Diagram and General Arrangement


A 002 CON_01 01 Content sheet A
003 SLD_01 01 Single Line Diagram
004 SLD_02 01 Single Line Diagram
005 FRT_01 01 Front View
006 FRT_02 01 Front View
007 FOU_01 01 Foundation View
008 FOU_02 01 Foundation View
009 SEC_01 01 Section View
010 SEC_02 01 Section View
011 SEC_03 01 Section View
B B

C C

D D
Confidential and Copyright Property of Schneider Electric

E E

F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Document type Content sheet Revision N° 01
page number
A3 RN RN UP
PT SCHNEIDER Drawing number PO110­201
23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name CON_01 002 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Next
Panel range / Standard Page
BB1 ­D.P11L1­3 ­D.P11L1­3 ­D.P11L1­3 ­D.P11L1­3
A PIX24 / IEC 60298 BB1 A
BB1 A A A A
BB1
Rated voltage BB1
BB1 ­D.P10 ­D.P10 ­D.P10 ­D.P10 ­D.P10
BB1 BB1 BB1 BB1
24kV BB1
BB1 V V V V V
BB1 ­D.F81 ­D.S610 ­D.F50 ­D.P50 ­D.S610 ­D.F50 ­D.P50 ­D.S610 ­D.F50 ­D.P50 ­D.S610 ­D.F50 ­D.P50 ­D.S610
Service Voltage EC1

20kV
­P.Q51 ­P.Q51 ­P.Q51 ­P.Q51
Rated frequency M M M M
50Hz
Rated current EC1
VTT VTT CTT CTT CTT CTT CTT CTT CTT CTT
1250A ­P.Q30
B Short circuit capacity (network) B
P1 P1 P1 P1
25kA
Rated peak withstand current ­B.Q932 ­B.Q931
­P.T51L1­3 ­P.T51L1­3 ­P.T51L1­3 ­P.T51L1­3
63kAp
Rated short­time withstand current
­P.F30L1­3 P2 P2 P2 P2
1 sec
Painting / Index Protection ­P.T61L1­3
RAL 7032 / IP41
Auxiliary voltage Protection
110 VDC ­P.C1L1­3 ­P.C1L1­3 ­P.C1L1­3 ­P.C1L1­3
C Auxiliary voltage Measurement C
110 VDC ­P.Q30 ­P.H101 ­P.Q30 ­P.H101 ­P.Q30 ­P.H101 ­P.Q30 ­P.H101
Auxiliary voltage Control
110 VDC
Auxiliary voltage Heating & Lighting
230 VAC
Auxiliary voltage Motordrive
110 VDC
Auxiliary voltage Signalisation
110 VDC
D Auxiliary voltage Remote control D
110 VDC
Panel Name, Schematic Type Panel No.1 (=J01) Panel No.2 (=J02) Panel No.3 (=J03) Panel No.4 (=J04) Panel No.5 (=J05)
Confidential and Copyright Property of Schneider Electric

Description BBVT + ES Outgoing 1 Outgoing 2 Outgoing 3 Outgoing 4


MV cable
Breaking device: Type, Rated current ­ HVX 24­25­06E, 630A, 25kA HVX 24­25­06E, 630A, 25kA HVX 24­25­06E, 630A, 25kA HVX 24­25­06E, 630A, 25kA
CT1: Type, Ratio CTB­24, 300­600 / 5 ­ 5A CTB­24, 300­600 / 5 ­ 5A CTB­24, 300­600 / 5 ­ 5A CTB­24, 300­600 / 5 ­ 5A
CT1: Accuracy, Power 5P20, 30VA / 0.5FS10, 30VA 5P20, 30VA / 0.5FS10, 30VA 5P20, 30VA / 0.5FS10, 30VA 5P20, 30VA / 0.5FS10, 30VA
CT2: Type, Ratio
CT2: Accuracy, Power
E ZCT: Type, Ratio E
ZCT: Accuracy, Power
VT: Type, Ratio VTB 24, 20kV/R3 : 110/R3 : 110/R3
VT: Accuracy, Power Class 0.2, 100VA / 3P, 30VA
VT Fuse: Quantity, Rating, Type 3, 2A, HSW
MV Fuse: Quantity, Rating, Type ­ ­ ­ ­ ­
Surge Arrester: Quantity, Type ­ ­ ­ ­ ­
Protection: Device, Function ­D.F81, 27,81O/U (P922) ­D.F50, MiCOM P123 (50/51,50N/51N,74,50BF,79,86) ­D.F50, MiCOM P123 (50/51,50N/51N,74,50BF,79,86) ­D.F50, MiCOM P123 (50/51,50N/51N,74,50BF,79,86) ­D.F50, MiCOM P123 (50/51,50N/51N,74,50BF,79,86)
Measurement: Device, Function P10 (VM) D.P50 (MK6N) (kWh, kVARh), P11L1­3 (AM),P10(VM) D.P50 (MK6N) (kWh, kVARh), P11L1­3 (AM),P10(VM) D.P50 (MK6N) (kWh, kVARh), P11L1­3 (AM),P10(VM) D.P50 (MK6N) (kWh, kVARh), P11L1­3 (AM),P10(VM)
Transducers
F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Document type Single line diagram Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name SLD_01 003 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Previous
Page

Panel range / Standard ­D.P11L1­3 ­D.P11L1­3 ­D.P11L1­3 ­D.P11L1­3 ­D.P11L1­3


A PIX24 / IEC 60298 A
A A A A A
Rated voltage ­D.P10 ­D.P10 ­D.P10 ­D.P10 ­D.P10
BB1 BB1 BB1 BB1 BB1
24kV V V V V V
­D.F51 ­D.P50 ­D.S610 ­D.F50 ­D.P50 ­D.S610 ­D.F50 ­D.P50 ­D.S610 ­D.F50 ­D.P50 ­D.S610 ­D.F50 ­D.P50 ­D.S610
Service Voltage
20kV
­P.Q51 ­P.Q51 ­P.Q51 ­P.Q51 ­P.Q51
Rated frequency M M M M M
50Hz
Rated current
CTT CTT VTT CTT CTT CTT CTT CTT CTT CTT CTT
1250A
B Short circuit capacity (network) B
P1 P1 P1 P1 P1
25kA
Rated peak withstand current
­P.T51L1­3 ­P.T51L1­3 ­P.T51L1­3 ­P.T51L1­3
63kAp ­P.T51L1­3

Rated short­time withstand current
P2 P2 P2 P2
1 sec
P2
Painting / Index Protection DIFFERENTIAL

RAL 7032 / IP41
EXTERNAL
Auxiliary voltage Protection
110 VDC ­P.C1L1­3 ­P.C1L1­3 ­P.C1L1­3 ­P.C1L1­3 ­P.C1L1­3
­B.Q932 ­B.Q931
C Auxiliary voltage Measurement C
­Y8
110 VDC ­P.Q30 ­P.H101 ­P.Q30 ­P.H101 ­P.Q30 ­P.H101 ­P.Q30 ­P.H101 ­P.Q30 ­P.H101
Auxiliary voltage Control
110 VDC
Auxiliary voltage Heating & Lighting ­P.T61L1­3
230 VAC ­P.F30L1­3

Auxiliary voltage Motordrive
110 VDC
Auxiliary voltage Signalisation
110 VDC
D Auxiliary voltage Remote control D
110 VDC
Panel Name, Schematic Type Panel No.6 (=J06) Panel No.7 (=J07) Panel No.8 (=J08) Panel No.9 (=J09) Panel No.10 (=J10)
Confidential and Copyright Property of Schneider Electric

Description Incoming Outgoing 5 Outgoing 6 Outgoing 7 Outgoing 8


MV cable
Breaking device: Type, Rated current HVX 24­25­12E, 1250A, 25kA HVX 24­25­06E, 630A, 25kA HVX 24­25­06E, 630A, 25kA HVX 24­25­06E, 630A, 25kA HVX 24­25­06E, 630A, 25kA
CT1: Type, Ratio CTB­24, 600­1200 / 5 ­ 5 ­ 5A CTB­24, 300­600 / 5 ­ 5A CTB­24, 300­600 / 5 ­ 5A CTB­24, 300­600 / 5 ­ 5A CTB­24, 300­600 / 5 ­ 5A
CT1: Accuracy, Power 5P20, 30VA / 5P20, 30VA / 0.2, 30VA 5P20, 30VA / 0.5FS10, 30VA 5P20, 30VA / 0.5FS10, 30VA 5P20, 30VA / 0.5FS10, 30VA 5P20, 30VA / 0.5FS10, 30VA
CT2: Type, Ratio
CT2: Accuracy, Power
E ZCT: Type, Ratio E
ZCT: Accuracy, Power
VT: Type, Ratio VTB 24, 20kV/R3 : 110/R3 : 110/R3
VT: Accuracy, Power Class 0.2, 50VA / 3P, 30VA
VT Fuse: Quantity, Rating, Type 3, 2A, HSW
MV Fuse: Quantity, Rating, Type ­ ­ ­ ­ ­
Surge Arrester: Quantity, Type ­ ­ ­ ­ ­
Protection: Device, Function ­D.F51, MiCOM P122 (50/51,50N/51N,74) ­D.F50, MiCOM P123 (50/51,50N/51N,74,50BF,79,86) ­D.F50, MiCOM P123 (50/51,50N/51N,74,50BF,79,86) ­D.F50, MiCOM P123 (50/51,50N/51N,74,50BF,79,86) ­D.F50, MiCOM P123 (50/51,50N/51N,74,50BF,79,86)
Measurement: Device, Function D.P50 (MK6E) (kWh, kVARh), P11L1­3 (AM),P10(VM) D.P50 (MK6N) (kWh, kVARh), P11L1­3 (AM),P10(VM) D.P50 (MK6N) (kWh, kVARh), P11L1­3 (AM),P10(VM) D.P50 (MK6N) (kWh, kVARh), P11L1­3 (AM),P10(VM) D.P50 (MK6N) (kWh, kVARh), P11L1­3 (AM),P10(VM)
Transducers
F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Document type Single line diagram Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name SLD_02 004 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Panel No.1 (=J01) Panel No.2 (=J02) Panel No.3 (=J03) Panel No.4 (=J04) Panel No.5 (=J05) Panel No.6 (=J06) Panel No.7 (=J07) Panel No.8 (=J08)


A BBVT + ES Outgoing 1 Outgoing 2 Outgoing 3 Outgoing 4 Incoming Outgoing 5 Outgoing 6 A

B B

% % % % % % % %
730

C C
2530

Next
EC1
BB1
BB1
BB1
BB1
BB1
BB1
BB1

Page
BB1
BB1
1800

D EC1
BB1 BB1 BB1 BB1 BB1 BB1 BB1 D
Confidential and Copyright Property of Schneider Electric

800 800 800 800 800 800 800 800


E E
8000

Note: The interlocking which will be applied is CB compartment door cannot be open when CB in service position
ALL DIMENSIONS ARE SHOWN IN MILIMETERS
UNLESS OTHERWISE NOTED

F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Document type Front view Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
Scale 23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name FRT_01 005 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Panel No.9 (=J09) Panel No.10 (=J10)
A Outgoing 7 Outgoing 8 A

B B

% %
730

C C
2530

Previous
Page
1800

D BB1 BB1 D
Confidential and Copyright Property of Schneider Electric

800 800
E E
8000

Note: The interlocking which will be applied is CB compartment door cannot be open when CB in service position
ALL DIMENSIONS ARE SHOWN IN MILIMETERS
UNLESS OTHERWISE NOTED

F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Document type Front view Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
Scale 23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name FRT_02 006 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Panel No.1 (=J01) Panel No.2 (=J02) Panel No.3 (=J03) Panel No.4 (=J04) Panel No.5 (=J05) Panel No.6 (=J06) Panel No.7 (=J07) Panel No.8 (=J08)


A BBVT + ES Outgoing 1 Outgoing 2 Outgoing 3 Outgoing 4 Incoming Outgoing 5 Outgoing 6 A

B 18,5 763 18,5


B

DETAIL B

707

Next
1416
1605

Page
338

C C

36
413,3

162

DETAIL A
187
114

800 800 800 800 800 800 800 800

8000

D D
DETAIL A
(SCALE 1:5)
Confidential and Copyright Property of Schneider Electric

DETAIL B
(SCALE 1:5)
36
43,2 29,7 37
ø12.5 FOR 73 7
ANCHOR BOLT

25 25
43,5

21x38

ø12.5 FOR
E 43 E
ANCHOR BOLT
40

87,5 20

ALL DIMENSIONS ARE SHOWN IN MILIMETERS
UNLESS OTHERWISE NOTED

F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Document type Foundation view Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
Scale 23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name FOU_01 007 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

Panel No.9 (=J09) Panel No.10 (=J10)
A Outgoing 7 Outgoing 8 A

B 18,5 763 18,5


B

DETAIL B

707

Previous
1416
1605

Page
338

C C

36
413,3

162

DETAIL A
187
114

800 800

8000

D D
DETAIL A
(SCALE 1:5)
Confidential and Copyright Property of Schneider Electric

DETAIL B
(SCALE 1:5)
36
43,2 29,7 37
ø12.5 FOR 73 7
ANCHOR BOLT

25 25
43,5

21x38

ø12.5 FOR
E 43 E
ANCHOR BOLT
40

87,5 20

ALL DIMENSIONS ARE SHOWN IN MILIMETERS
UNLESS OTHERWISE NOTED

F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Document type Foundation view Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
Scale 23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name FOU_02 008 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

1605 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100
A A

2530
2500

2400

Main Busbars 1250A
2300

With Insulation
Cu. 80X10
2200

Cu. 80X10
B 2100 B
With Insulation
L1
2000

1900
L2
1800

1700
L3
1600

C C
1500

1400

1300

1200

1100

1000
D D

900
Confidential and Copyright Property of Schneider Electric

­P.Q30
800

700

600
FUSE

500
Cu. 60X10
With Insulation
E E
400

­P.T61L1­3 300
Cu. 60X10
­P.R11
HEATER 200
Cu 50x5

100
E

Note :
Plate Thickness 2 ­ 3mm
F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel BBVT + ES Document type Section view Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
Scale 23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name SEC_01 009 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

1605 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100
A A

2530
2500

2400

Main Busbars 1250A
2300

With Insulation
Cu. 80X10
2200

Cu. 80X10
B With Insulation
2100 B
L1
2000

1900
L2
1800

1700
L3
1600

C C
1500

1400

­P.Q51
1300

1200

1100

1000
D Cu. 60X10 D
With Insulation
900 DETAIL "A"
­P.C1L1­3
­P.Q30 SCALE 1:10
Confidential and Copyright Property of Schneider Electric

CAP. DIVIDER
ES 800

60
700
30

"A" 600

70

100
500

30
Cu. 60X10

E ø9 E

ø13
400
P1 P2

300

­P.R11
­P.T51L1­3 HEATER 200
Cu 50x5

100
E

Note :
Plate Thickness 2 ­ 3mm
F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Outgoing Document type Section view Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
Scale 23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name SEC_02 010 / 011

1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8

A A
1605 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100

2530
2500

2400

2300

Main Busbars 1250A
With Insulation
Cu. 1X80X10
2200
B Cu. 1X80X10
B
With Insulation 2100
L1
2000

1900
L2
1800

1700
L3
C 1600 C

1500

1400

­P.Q51
1300

1200

1100

D D
1000
Cu. 1X80X10
With Insulation
900 DETAIL "A"
Confidential and Copyright Property of Schneider Electric

­P.C1L1­3
­P.Q30 CAP. DIVIDER SCALE 1:10
ES 800

80
700
Cu 30X5 30

600
FUSE

70
100
500

30
E "A" E
ø9

ø13
400
P1 P2
Cu. 1X80X10 ­P.T61L1­3
300

­P.R11
­P.T51L1­3 HEATER 200
Cu 50x5

100
E

Note :
Plate Thickness 2 ­ 3mm
F F
Format Drawn by Checked by Approved by Order N° M30178­EN1 Switchboard 24 kV Switchgear Panel Incoming Document type Section view Revision N° 01
A3 RN RN UP Drawing number PO110­201 page number
PT SCHNEIDER
Scale 23/02/2011 23/02/2011 23/02/2011
GI SIRIMAU INDONESIA Location Sheet name SEC_03 011 / 011

1 2 3 4 5 6 7 8

You might also like