IT'S IN OUR NATURE NIBE.

EU

Air/water heat pump


NIBE F2120
NIBE F2120 is an inverter-controlled air/water heat • Breakthrough in efficiency with a seasonal perform-
pump which represent a real breakthrough when it ance factor of over 5.0.*
comes to efficiency. With a seasonal performance
• Class leading working range, supply temperature
factor in excess of 5.0* , the heat pump provides
of up to 65°C, and 63°C at an outdoor temperature
more than five times as much heat per year as an
of -25°C.
electric heater with the same energy consumption.
NIBE F2120 provides optimum savings since the • Minimal noise level, even at full output.
heat pump automatically adapts to your home’s
output requirements all year round. *NIBE F2120 has a rating of SCOP > 5.0 (Average climate, Low
temperature) and SCOP 4.3 (Colder climate, Low temperature)
NIBE F2120 has a class leading working range and in accordance with European standard EN 14825:2013, i.e. the
standard for determining the reference seasonal performance
deliver a supply temperature of up to 65°C. Even at factor, SCOP. Applies to F2120-16 and -20.
outdoor temperatures of as low as -25°C, it still
provides a supply temperature of up to 63°C, while
keeping the noise level to a minimum. NIBE F2120
has three-phase connection, which simplifies elec-
trical installation.
Thanks to smart technology, the product gives you
control over your energy consumption and will be a
key part of your connected home. The efficient con-
trol system automatically adjusts the indoor climate
for maximum comfort, and you do nature a favour
at the same time.
IT'S IN OUR NATURE

This is how NIBE F2120 works


Installation method

F2120 – a part of your climate system where F2120 is


intended to be combined with one of the indoor modules
VVM or the control modules SMO.
Together with an indoor module, F2120 creates a com-
plete heating/cooling and hot water unit. Our flexible
indoor modules provide efficient heating and high hot
water performance. VVM indoor modules are complete
with a smart and user-friendly control system, hot water
heater, additional heat, self-regulating circulation pump,
etc.
The control modules, SMO, offer a flexible system
solution that can be easily customised. For systems
with SMO, different components such as water heaters,
additional heat and other accessories can be selected
to suit the installation's requirements. Up to eight F2120
can be connected to a SMO 40.
There is a wide range of system solutions and accessor-
ies for NIBE's indoor modules and control modules.

2 NIBE F2120
IT'S IN OUR NATURE

COMPATIBLE INDOOR MODULES (VVM) AND CONTROL MODULES (SMO)


VVM S320
F2120-8 X
F2120-12 X
F2120-16 X
F2120-20

VVM 225 VVM 310 VVM 320 VVM 500 SMO 20 SMO 40
F2120-8 X X X X X X
F2120-12 X X X X X
F2120-16 X X X X X
F2120-20 X X X

NIBE F2120 3
IT'S IN OUR NATURE

INDOOR MODULES

VVM 225

APH

UN
LEK

LEK

APH

UN
VVM S320 VVM S320
Stainless steel, 3x230 V Enamel, 3x400 V VVM 225 VVM 225
Part no. 069 201 Part no. 069 206 Enamel, 3x400 V Stainless steel, 3x400 V
Part no. 069 227 Part no. 069 229
VVM S320 VVM 310 VVM 310
Stainless steel, 3x400 V Stainless steel, 3x400 V Stainless steel, 3x400 V
Part no. 069 196 Part no. 069 430 With integrated EMK 310
Part no. 069 084

VVM 320 VVM 320


Stainless steel, 1x230 V Stainless steel, 3x230 V
Part no. 069 111 Part no. 069 113

VVM 320 VVM 320


Enamel, 3x400 V Stainless steel, 3x400 V
With integrated EMK 300 Part no. 069 109
Part no. 069 203

VVM 320 VVM 500


Copper, 3x400 V Stainless steel, 3x400 V
Part no. 069 108 Part no. 069 400

4 NIBE F2120
IT'S IN OUR NATURE

CONTROL MODULES
SMO 20
Control module
Part no. 067 224

LEK
SMO 40
Control module
Part no. 067 225
LEK

NIBE F2120 5
IT'S IN OUR NATURE

Principle of operation
Principle of operation with hot water and a heating sys-
tem.
The heating medium side and the domestic hot water
side must be fitted with the necessary safety equipment
in accordance with the applicable regulations.

EXPLANATION
EB15 Indoor module (VVM S320 / VVM 320)

EB101 Heat pump (F2120)


FL10 Safety valve, heat pump
QM41 Shut-off valve
QZ2 Filterball
XL1 Connection, heating medium out of F2120
XL2 Connection, heating medium in to F2120,

-EB15

-QM40
-EB101
-XL1
-QZ2
-FL10
-XL2
-QM1

6 NIBE F2120
IT'S IN OUR NATURE

Good to know about


NIBE F2120
Transport and storage F2120
F2120

F2120 must be transported and stored vertically.


Ensure that the heat pump cannot fall over during
transport.
min
Ensure that the heat pump cannot be damaged during min 300 mm
70 mm
LEK
transportation. LEK

Do not place F2120 directly on the lawn or other non


Installation and solid surface.

positioning
• Place F2120 outdoors on a solid level base that can
take the weight, preferably a concrete foundation. If
concrete slabs are used they must rest on asphalt or
shingle.
• The lower edge of the evaporator must be at the level
of the average local snow depth. The concrete
foundation or concrete plinths must therefore be at
least 70 mm high.
• F2120 should not be positioned next to noise sensitive
walls, for example, next to a bedroom.
• Also ensure that the placement does not inconveni-
ence the neighbours.
If there is a risk of snow slip from roof, a protective roof
• F2120 must not be placed so that recirculation of the
or cover must be erected to protect the heat pump,
outdoor air can occur. This causes lower output and
pipes and wiring.
impaired efficiency.
• The evaporator must be sheltered from direct wind / ,
which negatively affects the defrosting function. Place
F2120 protected from wind / against the evaporator.
• Small amounts of condensation water, as well as melt
water from defrosting, may be produced. Condensa-
tion water must be led off to a drain or equivalent.
• Care must be exercised so that the heat pump is not
scratched during installation.

NIBE F2120 7
IT'S IN OUR NATURE

LIFT FROM THE STREET TO THE SET UP LIFT FROM THE PALLET TO FINAL
LOCATION POSITIONING
If the base allows, the simplest thing is to use a pallet Before lifting remove the packaging and the securing
truck to move the F2120 to the set up location. strap to the pallet.
The centre of gravity is offset to one side (see print on Place lifting straps around each machine foot. Lifting
the packaging). from the pallet to the base requires four persons, one
for each lifting strap.

C:a 180 kg
Approx. 180 kg Supplied components
Local differences in the enclosed kit may occur. See
relevant installer manual for more information.

F2120-8, F2120-12

LEK

LEK

2 x flexible pipes (DN25,


G1") with 4 x gaskets. Filterball (G1").

F2120-16, F2120-20
LEK

LEK

LEK

2 x flexible pipes (DN25, G1


1/4") with 4 x gaskets. Filterball (G1 1/4").

If F2120 needs to be transported across soft ground,


such as a lawn, we recommend that a crane is used
that can lift the unit to the installation location. When
F2120 is lifted with a crane, the packaging must be un-
disturbed, see the illustration above.
If a crane vehicle cannot be used the F2120 can be
transported on an extended sack truck. F2120 must be
taken from its heaviest side and two people are required
to lift F2120.

8 NIBE F2120
IT'S IN OUR NATURE

Installation area
The distance between F2120 and the house wall must
be at least 350 mm. Clearance above F2120 must be at
least 1,000 mm. Free space in front must be at least
1,000 mm for any future servicing.

350 mm

350 – 500 mm Free space behind*


Fritt utrymme bakom

400 mm 600 mm
400 mm 600mm

600
600 mm
mm

Minimum free
Minimalt MinimumMinimalt
free space
space
fritt utrymme fritt utrymme
Min. avstånd
Minimum distance during use
vid användning
1000 mm

At least 1,000 ofavseveral F2120


flera F2300
mm
Free space inFritt
front for any
utrymme future servicing
framför
dock 1000 mm för ev. framtida service

NIBE F2120 9
IT'S IN OUR NATURE

Installation
• The insulation must seal against the bottom of the
Inspection of the condensation water trough.

installation RECOMMENDED ALTERNATIVE FOR


LEADING OFF CONDENSATION WATER
Current regulations require the heating installation to be
inspected before it is commissioned. The inspection Stone caisson
must be carried out by a suitably qualified person and F2120

should be documented. The above applies to closed


heating systems.
If the heat pump is replaced, the installation must be
inspected again.

Condensation water
trough Frost proof
Frostfritt djup
depth
The condensation water trough collects and leads away
most of the condensation water from the heat pump.
It is important for the heat pump’s function that the
condensation water is led away and that the outlet for
the condensation water pipe is positioned so as to pre-
vent damage to the building. Condensation run-off
should be checked regularly, especially during the au- LEK

tumn. Clean if necessary.


If the house has a cellar the stone caisson must be po-
Pipe with heating cable for draining the condensate drain sitioned so that condensation water does not affect the
pan is not included. To ensure this function, the access- house. Otherwise the stone caisson can be positioned
ory KVR 10 should be used. directly under the heat pump.
• The condensation water (up to 50 litres/24 hrs) that The outlet of the condensation water pipe must be at
collects in the trough should be routed away by a pipe frost free depth.
to an appropriate drain, it is recommended that the
shortest outdoor stretch possible is used.
• The section of the pipe that can be affected by frost
must be heated by the heating cable to prevent
freezing.
• Route the pipe downward from F2120.
• The outlet of the condensation water pipe must be at
a depth that is frost free or alternatively indoors (with
reservation for local ordinances and regulations).
• Use a water trap for installations where air circulation
may occur in the condensation water pipe.

10 NIBE F2120
IT'S IN OUR NATURE

Drain indoors Gutter drainage

F2120

Joint

Water seal LEK

Water seal Frostfritt


Frost free
djup
depth

The condensation water is lead to an indoor drain (sub- The outlet of the condensation water pipe must be at
ject to local rules and regulations). frost free depth.
Route the pipe downward from F2120. Route the pipe downward from F2120.
The condensation water pipe must have a water seal to The condensation water pipe must have a water seal to
prevent air circulation in the pipe. prevent air circulation in the pipe.
KVR 10 spliced as illustrated. Pipe routing inside house If none of the recommended alternatives is used good
not included. lead off of condensation water must be assured.

NIBE F2120 11
IT'S IN OUR NATURE

MINIMUM SYSTEM FLOWS


Pipe installation The installation must be dimensioned at least to manage
Pipe installation must be carried out in accordance with the minimum defrosting flow at 100% pump operation,
current norms and directives. see table.
The pipe dimension should not be less than the recom- Air/water Minimum Minimum re- Minimum re-
mended pipe diameter according to the table. However, heat pump flow during commended commended
each system must be dimensioned individually to man- defrosting pipe dimen- pipe dimen-
age the recommended system flows. (100% pump sion (DN) sion (mm)
speed (l/s)
F2120-8 0.27 20 22
(1x230V)
F2120-8 0.27 20 22
F2120-12 0.35 25 28
(1x230V)
F2120-12 0.35 25 28
F2120-16 0.38 25 28
F2120-20 0.48 32 35

An undersized system can result in damage to the ma-


chine and lead to malfunctions.
F2120 can only operate up to a return temperature of
about 55 °C and an outgoing temperature of about 65 °C
from the heat pump.
F2120 is not equipped with external shut off valves on
the water side; these must be installed to facilitate any
future servicing. The return temperature is limited by
the return line sensor.

WATER VOLUMES
Depending on the size of your F2120, an available water
volume is required to prevent short operating times and
to enable defrosting. For the optimum operation of
F2120, a minimum available water volume of 10 litres
multiplied by the size number is recommended. E.g.
F2120-12: 10 litres x 12 = 120 litres. This applies indi-
vidually to heating and cooling systems.

12 NIBE F2120
IT'S IN OUR NATURE

PIPE COUPLING HEATING MEDIUM CIRCUIT HEAT INSULATION


• The heat pump must be vented by the upper connec-
tion (XL1) using the venting nipple on the enclosed
flexible hose.
• Install the enclosed particle filter before the inlet, i.e.
the lower connection (XL2) on F2120. Heat insulation

• All outdoor pipes must be thermally insulated with at


least 19 mm thick pipe insulation.
• Install shutoff and drain valves so that F2120 can be
emptied in the event of prolonged power failures.
• The supplied flexible hoses act as vibration dampers.
The flexible pipes are fitted so an elbow is created,
thus acting as vibration damping.

Charge pump LEK

The charge pump (not included in the product) is


powered and controlled from the control module. It has
a built-in anti-freezing function and, for this reason, must INSTALLING FLEX HOSES
not be switched off when there is a risk of freezing.
At temperatures below +2 °C the charge pump runs
periodically, to prevent the water from freezing in the
charge circuit. The function also protects against excess Data

temperatures in the charge circuit. Serie.nr.

PRESSURE DROP, HEATING MEDIUM SIDE


F2120-8,
Tryckfall -12,
F2120 -16, -20
Tryckfall
Pressure drop
[kPa]
(kPa)
15
14 -12/-16/-20 XL1
13
12 OUT

IN

11 Art.nr.
711453

10 -8
9
8
LEK

7
6
5 XL2
4
3
2
1
0
0 0,05 0,1 0,15 0,2 0,25 0,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9 XL1 Connection, heating medium out of F2120
Flöde Flow
[l/s]
(l/s) XL2 Connection, heating medium in to F2120,

DOCKING
F2120 can be connected in several ways. The necessary
safety equipment must be installed in accordance with
current regulations for all docking options.
See nibe.eu/ODM for more detailed docking options.

NIBE F2120 13
IT'S IN OUR NATURE

Electrical connections
• The heat pump must not be connected without the
permission of the electricity supplier and must be
connected under the supervision of a qualified electri-
cian.
• If F2120 is fused with a miniature circuit breaker, it
must have at least motor characteristic ”C”. For MCB
size see "Technical Specifications".
• F2120 does not include an omnipolar circuit breaker
on the incoming power supply. The heat pump’s
supply cable must be connected to a circuit breaker
with at least a 3 mm breaking gap. When the building
is equipped with an earth-fault breaker, the heat pump
should be equipped with a separate one. The earth-
fault breaker should have a nominal tripping current
of no more than 30 mA. Incoming supply must be
400V 3N~ 50Hz via electrical distribution units with
fuses.
For 230V~ 50Hz, the incoming supply must be 230V~
50Hz via distribution box with fuses.
• If an insulation test is to be carried out in the building,
disconnect the heat pump.
• If the control is to be supplied separately from other
components in the heat pump (e.g. for tariff connec-
tion), a separate operating cable must be connected
to terminal block (X5).
• The routing of cables for heavy current and signals
should be made out through the cable glands on the
heat pump's right-hand side, seen from the front.
• The communication cable must be a three core,
shielded cable and be connected between F2120 ter-
minal block X22 and the control module.
• Connect the charge pump to the control module. See
where the charge pump is to be connected in the In-
staller Manual for your control module.

14 NIBE F2120
IT'S IN OUR NATURE
F2120 F2120

Maintenance LEK LEK

When your heat pump is located outdoors some external KEEP FREE OF SNOW AND ICE
maintenance is required.
Insufficient maintenance can cause serious damage to
F2120, which is not covered by the guarantee.

Checking grilles and F2120

bottom panel on F2120 F2120

F2120
Regularly check throughout the year that the grille is not
clogged by leaves, snow or anything else.
LEK

You should be vigilant during windy conditions and/or


in the event of snow as the grille can become blocked.
LEK LEK

Also check that the drain holes in the bottom panel (ten) Prevent snow from building up and covering the grilles and drain holes
on F2120.
are free from dirt and leaves.
Regularly check that condensation is routed away cor-
rectly through the condensation pipe. Ask your installer
for assistance if required.

F2120

LEK

Keep free of snow and/or ice.

NIBE F2120 15
IT'S IN OUR NATURE

Cleaning the outer


casing
If necessary the outer casing can be cleaned using a
damp cloth.
Care must be exercised so that the heat pump is not
scratched when cleaning. Avoid spraying water into the
grilles or the sides so that water penetrates into F2120.
Prevent F2120 coming into contact with alkaline cleaning
agents.

16 NIBE F2120
IT'S IN OUR NATURE

Functions
When connection to NIBE indoor module / control
module (VVM / SMO) is ready, you can control your unit Hot water production
via the indoor module / control module.
Hot water charging starts when the temperat-
ure has fallen to the set start temperature. Hot
Control, general water charging stops when the hot water
temperature at the hot water sensor has been reached.
The indoor temperature depends on several different
factors. Sunlight and heat emissions from people and For temporary higher hot water demand, there is a
household machines are normally sufficient to keep the function that allows the temperature to be raised tem-
house warm during the warm seasons. When it gets porarily for up to 12 hours or by a one time increase
colder outside, the climate system needs to help heat (can be selected in the menu system).
the house. The colder it is outside, the warmer radiators It is also possible to put the installation in holiday mode,
and underfloor heating systems have to be. which means that the lowest possible temperature is
Control of the heat production is performed based on maintained without the risk of freezing.
the "floating condensing" principle, which means that
the temperature level needed for heating at a specific
outdoor temperature is produced based on collected
Additional heat only
values from the outdoor and supply temperature
ADDITIONAL HEAT ONLY
sensors. The room sensor can also be used to com-
pensate the deviation in room temperature. The indoor module (VVM), which is connected to F2120,
can be used with the additional heat alone (electric

Heat production boiler) to produce heating and hot water, for example
before the outdoor module is installed.
The supply of heat to the house is regulated in
accordance with the heating curve setting se-
lected. After adjustment, the correct amount
Alarm indications
of heat for the current outdoor temperature is supplied. The status lamp lights red in the event of an alarm and
The supply temperature of the heat pump will oscillate the display shows detailed information depending on
around the theoretically required value. the fault. An alarm log is created with each alarm con-
taining a number of temperatures, times and operating
OWN CURVE status.
F2120 has pre-programmed non-linear heating curves.
It is also possible to create your own defined curve. This
is an individual linear curve with a number of break
points. You select break points and the associated
temperatures.

NIBE F2120 17
IT'S IN OUR NATURE

NIBE SMART PRICE ADAPTION™


The display Smart Price Adaption is not available in all
The indoor module (VVM) / control module (SMO) is countries. Contact your NIBE dealer for more
controlled using a clear and easy to use display. information.
Instructions, settings and operational information are Smart Price Adaption adjusts the heat pump's consump-
shown on the display. You can easily navigate between tion according to the time of day that electricity prices
the different menus and options to set the comfort or are lowest. This allows for savings, provided that the
obtain the information you require. hourly rate subscription has been signed with the elec-
tricity supplier.
The display unit is equipped with a USB socket that can
be used to update the software and save logged inform- The function is based on hourly rates for the coming day
ation in the indoor module / control module. being downloaded via NIBE Uplink. To use the function,
an Internet connection and account on NIBE Uplink are
Visit nibeuplink.com and click the "Software" tab to
necessary.
download the latest software for your installation.
SMART HOME
NIBE Uplink When you have a smart home system that can commu-
nicate with NIBE Uplink, you can control the installation
Using the Internet and NIBE Uplink, you can via an app by activating the "smart home" function.
obtain a quick overview and the present status
By allowing connected units to communicate with NIBE
of the installation and the heating in your home.
Uplink, your heating system becomes a natural part of
You can obtain a good overall view, allowing you to
your homesmart home and gives you the opportunity
monitor and control the heating and hot water comfort
to optimise the operation.
effectively. If the system is affected by a malfunction,
you receive an alert via e-mail that allows you to react Remember that the “smart home” function requires
quickly. NIBE Uplink in order to work.
NIBE Uplink also gives you the opportunity to control
the comfort in your home easily, no matter where you
are.

RANGE OF SERVICES
You have access to different levels of service via NIBE
Uplink. A basic level that is free and a premium level
where you can select different extended service func-
tions for a fixed annual subscription fee (the subscription
fee varies depending on the selected functions).
NIBE Uplink also available as an app from App Store and
Google Play.

INSTALLATION AND ASSOCIATED


EQUIPMENT REQUIREMENTS
NIBE Uplink needs the following in order to communic-
ate with your F2120:
• network cable
• Internet connection to which F2120 can be connected
• web browser with JavaScript activated
• account on nibeuplink.com

We recommend our mobile apps for NIBE Uplink.


For more information, visit nibeuplink.com.

18 NIBE F2120
IT'S IN OUR NATURE

Technical data
F2120-16 / F2120-20 working range
Working area Arbetsområde F2120-16 / F2120-20
Supply temperature
Framledningstemperatur
(°C)
(°C)
F2120-8 working range 75
Arbetsområde F2120-8 70
Supply temperature 65
Framledningstemperatur
(°C) 60
75 55
70 50
65 45
60 40
55 35
50 30
45 25
40 20
35 15
30 10
25 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45
20 Utomhustemperatur
Outdoor temperature
15 Supply temperature
Framledningstemperatur (°C)
(°C)
10 Return temp
Returledningstemperatur
-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45
Outdoor temperature
Utomhustemperatur
Supply temperature
Framledningstemperatur (°C)
(°C) F2120 working range cooling
Return temp
Returledningstemperatur
Framledningstemperatur
Supply temperature
(°C)
(°C)
F2120-12 working range 35
Arbetsområde F2120-12
Framledningstemperatur
Supply temperature 30
(°C)
(°C)
75
25
70
65
60 20
55
50 15
45
40 10
35
30 5
25 10 15 20 25 30 35 40 45
20 Outdoor temperature
Utomhustemperatur
15 Framledningstemperatur
Supply temperature (°C)
(°C)
10 Returledningstemperatur
Return temp
-30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45
Outdoor temperature
Utomhustemperatur
Supply temperature
Framledningstemperatur (°C)
(°C) During shorter time it is allowed to have lower working
Return temp
Returledningstemperatur temperatures on the water side, e.g. during start up.

NIBE F2120 19
IT'S IN OUR NATURE

F2120-12
Heating F2120-12 Max
F2120-12 maxochand
min min
uppvärmningskapacitet
heating capacity
OUTPUT AND COP AT DIFFERENT SUPPLY Heating capacity
Uppvärmningskapacitet
(kW)
(kW)
TEMPERATURES 10
9
Maximum capacity during continuous operation. Defrost-
8
ing is not included.
7
F2120-8 6
5
F2120-8 Max
F2120-8 maxochand
min min
uppvärmningskapacitet
heating capacity 4
Uppvärmningskapacitet
Heating capacity 3
(kW)
(kW) 2
7 1
6 0
-25 -20 -15 -10 -5 0 5 10 15
5 Utomhustemperatur
Outdoor temperature
Framledningstemperatur
Supply temperature (35°C) (35 °C) (°C)
(°C)
4 Framledningstemperatur
Supply temperature (45°C) (45 °C)
3 Supply temperature (55°C) (55 °C)
Framledningstemperatur

2
F2120-12 COP
1 F2120-12 COP
0 COP
COP
-25 -20 -15 -10 -5 0 5 10 15 7
Utomhustemperatur
Outdoor temperature
Framledningstemperatur
Supply temperature (35°C) (35 °C) (°C)
(°C) 6
Supply temperature (45°C) (45 °C)
Framledningstemperatur
Supply temperature (55°C) (55 °C) 5
Framledningstemperatur
4
F2120-8 COP 3
F2120-8 COP
2
COP
COP
6 1

5 0
-25 -20 -15 -10 -5 0 5 10 15
4 Utomhustemperatur
Outdoor temperature
Framledningstemperatur
Supply temperature (35°C) (35 °C) (°C)
(°C)
3 Framledningstemperatur
Supply temperature (45°C) (45 °C)
Framledningstemperatur
Supply temperature (55°C) (55 °C)
2

0
-25 -20 -15 -10 -5 0 5 10 15
Utomhustemperatur
Outdoor temperature
Supply temperature (35°C) (35 °C)
Framledningstemperatur (°C)
(°C)
Supply temperature (45°C) (45 °C)
Framledningstemperatur
Supply temperature (55°C) (55 °C)
Framledningstemperatur

20 NIBE F2120
IT'S IN OUR NATURE

F2120-16 F2120-20
F2120-16
F2120-16 Max
maxochand
min uppvärmningskapacitet
min heating capacity F2120-20
F2120-20 Max
maxochand
min uppvärmningskapacitet
min heating capacity
Uppvärmningskapacitet
Heating capacity Uppvärmningskapacitet
Heating capacity
(kW)
(kW) (kW)
(kW)
14 18

12 16
14
10
12
8 10

6 8
6
4
4
2 2
-25 -20 -15 -10 -5 0 5 10 15 -25 -20 -15 -10 -5 0 5 10 15
Utomhustemperatur
Outdoor temperature Utomhustemperatur
Outdoor temperature
Framledningstemperatur
Supply temperature (35°C) (35 °C) (°C)
(°C) Framledningstemperatur
Supply temperature (35°C) (35 °C) (°C)
(°C)
Framledningstemperatur
Supply temperature (45°C) (45 °C) Framledningstemperatur
Supply temperature (45°C) (45 °C)
Supply temperature (55°C) (55 °C)
Framledningstemperatur Supply temperature (55°C) (55 °C)
Framledningstemperatur

F2120-16 COP F2120-20 COP


F2120-16 COP F2120-20 COP
COP
COP COP
COP
6 6

5 5

4 4

3 3

2 2

1 1

0 0
-25 -20 -15 -10 -5 0 5 10 15 -25 -20 -15 -10 -5 0 5 10 15
Utomhustemperatur
Outdoor temperature Utomhustemperatur
Outdoor temperature
Framledningstemperatur
Supply temperature (35°C) (35 °C) (°C)
(°C) Supply temperature (35°C) (35 °C)
Framledningstemperatur (°C)
(°C)
Supply temperature (45°C) (45 °C)
Framledningstemperatur Supply temperature (45°C) (45 °C)
Framledningstemperatur
Supply temperature (55°C) (55 °C)
Framledningstemperatur Supply temperature (55°C) (55 °C)
Framledningstemperatur

NIBE F2120 21
IT'S IN OUR NATURE

F2120-16 maxochand min cooling capacity


Cooling F2120-16 Max min kylningskapacitet

Kylningskapacitet
Cooling
(kW)
capacity
(kW)
10,0
OUTPUT AT DIFFERENT SUPPLY
9,0
TEMPERATURES (COOLING)
8,0
F2120-8Max
F2120-8 maxochand min cooling capacity
min kylningskapacitet
7,0
Kylningskapacitet
Cooling capacity 6,0
(kW)
(kW)
6,0 5,0
5,5 4,0
5,0 3,0
4,5
2,0
4,0 15 20 25 30 35 40 45
3,5 Utomhustemperatur
Outdoor temperature
Framledningstemperatur
Supply temperature (25°C) (25 °C) (°C)
(°C)
3,0
Framledningstemperatur
Supply temperature (18°C) (18 °C)
2,5
Supply temperature (7°C) (7 °C)
Framledningstemperatur
2,0
1,5
1,0
15 20 25 30 35 40 45
Utomhustemperatur
F2120-20 max
F2120-20 Max och and min cooling capacity
min kylningskapacitet
Outdoor temperature
Framledningstemperatur
Supply temperature (25°C) (25 °C) (°C)
(°C) Kylningskapacitet
Cooling capacity
Framledningstemperatur
Supply temperature (18°C) (18 °C) (kW)
(kW)
Framledningstemperatur
Supply temperature (7°C) (7 °C) 11,0
10,0
9,0
8,0
F2120-12
F2120-12 max
Max ochand min cooling capacity
min kylningskapacitet
7,0
Kylningskapacitet
Cooling capacity 6,0
(kW)
(kW) 5,0
7,0 4,0
3,0
6,0
2,0
5,0 1,0
15 20 25 30 35 40 45
Utomhustemperatur
Outdoor temperature
4,0
Framledningstemperatur
Supply temperature (25°C)(25 °C) (°C)
(°C)
3,0 Framledningstemperatur
Supply temperature (18°C)(18 °C)
Supply temperature (7°C) (7 °C)
Framledningstemperatur
2,0

1,0
15 20 25 30 35 40 45
Utomhustemperatur
Outdoor temperature
Framledningstemperatur
Supply temperature (25°C) (25 °C) (°C)
(°C)
Framledningstemperatur
Supply temperature (18°C) (18 °C)
Framledningstemperatur
Supply temperature (7°C) (7 °C)

22 NIBE F2120
IT'S IN OUR NATURE

Dimensions
F2120-8

F2120

180
1030

475

110
70
Ø52
35 - 65
1055 40 470 65 85

Ø40
610

1130

F2120-12, -16, -20

F2120
180
1130

475

110
70

Ø52
35 - 65

1205 40 470 65 85

Ø40
612

1280

NIBE F2120 23
IT'S IN OUR NATURE

Sound pressure levels


F2120 is usually placed next to a house wall, which gives
a directed sound distribution that should be considered.
Accordingly, you should always attempt when position-
ing to choose the side that faces the least sound sens-
itive neighbouring area.
The sound pressure levels are further affected by walls,
bricks, differences in ground level, etc and should
therefore only be seen as guide values.

LEK

2m

6m
10 m

F2120 8 12 16 20
Sound power level (LWA), according to EN12102 at 7 / 45 (nominal) LW(A) 53 53 55 55
Sound pressure level (LPA) at 2 m* dB(A) 39 39 39 39
Sound pressure level (LPA) at 6 m* dB(A) 29.5 29.5 29.5 29.5
Sound pressure level (LPA) at 10 m* dB(A) 25 25 25 25

* Free space.

24 NIBE F2120
IT'S IN OUR NATURE

Technical specifications
F2120 – 1x230V 8 12
Output data according to EN 14511, partial load1) Outdoor temp./ Sup-
ply temp.
Heating -7 / 35 °C 5.17 / 1.72 / 3.00 7.35 / 2.43 / 3.02
Capacity / Power input / COP (kW/kW/-) 2 / 35 °C 4.03 / 0.91 / 4.43 5.21/ 1.22 / 4.27
at nominal flow 2 / 45 °C 4.07 / 1.16 / 3.51 5.27 / 1.49 / 3.54
7 / 35 °C 3.57 / 0.78 / 4.57 3.54 / 0.69 / 5.12
7 / 45 °C 3.66 / 0.98 / 3.74 3.64 / 0.91 / 4.00

Cooling 35 / 7 °C 3.80 / 1.28 / 2.97 4.69 / 1.70 / 2.76


Capacity / Power input / EER (kW/kW/-) 35 / 18 °C 5.10 / 1.37 / 3.73 5.44 / 1.73 / 3.15
at maximum flow

Electrical data
Rated voltage 230V ~ 50Hz
Max operating current, heat pump Arms 14 16
Max operating current, compressor Arms 13 15
Max output, fan W 40 45
Fuse Arms 16 16
Enclosure class -

Refrigerant circuit
Type of refrigerant R410A
GWP refrigerant 2088
Type of compressor Scroll
Volume kg 2.4 2.6
CO2-equivalent (The cooling circuit is hermetically sealed.) t 5.01 5.43

Brine
Max airflow m3/h 2,400 3,400
Min/Max air temp, max °C -25 / 43

Heating medium circuit


Max system pressure heating medium MPa 0.45 (4.5 bar)
Recommended flow interval, heating operation l/s 0.08 / 0.32 0.11 / 0.44
Min. design flow, defrosting (100 % pump speed) l/s 0.27 0.35
Min/Max HM temp continuous operation °C 26 / 65
Connection heating medium F2120 G1 1/4" external thread
Connection heating medium flex pipe G1 external thread
Min. recommended pipe dimension (system) DN (mm) 20 (22) 25 (28)

Miscellaneous
Weight (excl. packaging) kg 150 160
Substances according to Directive (EG) no. 1907/2006, article 33 (Reach) Lead in brass components
Part No. 064 134 064 136

NIBE F2120 25
IT'S IN OUR NATURE

F2120 – 3x400V 8 12 16 20
Output data according to EN 14511, partial load1) Outd. temp: / Supply
temp.
Heating -7 / 35 °C 5.17/1.72/3.00 7.35/2.43/3.02 10.13/3.33/3.04 13.50/4.70/2.87

Capacity / Power input / COP (kW/kW/-) 2 / 35 °C 4.03/0.91/4.43 5.21/1.22/4.27 7.80/1.79/4.36 9.95/2.36/4.22


at nominal flow 2 / 45 °C 4.07/1.16/3.51 5.27/1.49/3.54 7.97/2.24/3.56 10.41/2.88/3.61
7 / 35 °C 3.57/0.78/4.57 3.54/0.69/5.12 5.17/1.01/5.11 5.17/1.01/5.11
7 / 45 °C 3.66/0.98/3.74 3.64/0.91/4.00 5.49/1.33/4.14 5.49/1.33/4.14

Cooling 35 / 7 °C 3.80/1.28/2.97 4.69/1.70/2.76 7.09/2.72/2.61 8.10/3.50/2.31

Capacity / Power input / EER (kW/kW/-) 35 / 18 °C 5.10/1.37/3.73 5.44/1.73/3.15 8.19/2.83/2.90 9.26/3.64/2.54


at maximum flow

Electrical data
Rated voltage 400V 3N ~ 50Hz
Max operating current, heat pump Arms 6 7 9.5 11
Max operating current, compressor Arms 5 6 8.5 10
Max output, fan W 40 45 68 80
Fuse Arms 10 10 10 13
Enclosure class -

Refrigerant circuit
Type of refrigerant R410A
GWP refrigerant 2088
Type of compressor Scroll
Volume kg 2.4 2.6 3 3
CO2-equivalent (The cooling circuit is hermetically sealed.) t 5.01 5.43 6.26 6.26

Brine
Max airflow m3/h 2,400 3,400 4,150 4,500
Min/Max air temp, max °C -25 / 43

Heating medium
Max system pressure heating medium MPa 0.45 (4.5 bar)
Recommended flow interval, heating operation l/s 0.08/0.32 0.11/0.44 0.15/0.60 0.19/0.75
Min. design flow, defrosting (100 % pump speed) l/s 0.27 0.35 0.38 0.48
Min/Max HM temp continuous operation °C 26 / 65
Connection heating medium F2120 G1 1/4" external thread
Connection heating medium flex pipe G1 external thread G1 1/4" external thread
Min. recommended pipe dimension (system) DN (mm) 20 (22) 25 (28) 25 (28) 32 (35)

Miscellaneous
Weight (excl. packaging) kg 167 177 183
Substances according to Directive (EG) no. 1907/2006, article 33 (Reach) Lead in brass components
Part No. 064 135 064 137 064139 064 141

26 NIBE F2120
IT'S IN OUR NATURE

SCOP & Pdesignh F2120 according to EN 14825


F2120 8 12 16 20
Pdesignh SCOP Pdesignh SCOP Pdesignh SCOP Pdesignh SCOP
SCOP 35 Average climate 5.9 4.80 8 4.83 11 5.05 11 5.05
(Europe)
SCOP 55 Average climate 6.3 3.75 8.3 3.78 12.3 3.9 12.3 3.9
(Europe)
SCOP 35 Cold climate 6.8 4.03 9.3 4.05 13 4.25 13 4.25
SCOP 55 Cold climate 7.4 3.33 9.8 3.33 14 3.53 14 3.53
SCOP 35 Warm climate 5.9 5.43 9.2 5.48 13 5.5 13 5.5
SCOP 55 Warm climate 6.3 4.35 9.2 4.48 13 4.5 13 4.5

1)Power statements including defrosting according to EN 14511 at heating medium supply corresponding to DT=5 K at 7 / 45.
2)Nominal flow corresponds to DT=10 K at 7 / 45.

ENERGY RATING, AVERAGE CLIMATE


Model F2120-8 F2120-12 F2120-16 F2120-20
Control module model SMO SMO SMO SMO
Temperature application °C 35 / 55 35 / 55 35 / 55 35 / 55
The product’s room heating efficiency class1) A+++ / A++ A+++ / A++ A+++ / A+++ A+++ / A+++
Space heating efficiency class of the system2) A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++

1Scale for the product’s room heating efficiency class A++ to G.


2Scale for the system’s room heating efficiency class A+++ to G.
The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to
the package, the overall efficiency of the package should be recalculated.

NIBE F2120 27
IT'S IN OUR NATURE

Accessories
Detailed information about the accessories and complete
accessories list available at nibe.eu.
Not all accessories are available on all markets.
Condensation water pipe
Condensation water pipe, different lengths.

KVR 10-10 F2120 LEK

1 metres

KVR 10-30 F2120


3 metres

KVR 10-60 F2120


6 metres

28 NIBE F2120
PBD EN 1943-5 M11996
NIBE Energy Systems
Box 14, SE-285 21 Markaryd
nibe.eu

WS name: -Gemensamt
WS version: a697
WS release date: 2019-09-24 14:33
Publish date: 2019-10-14 07:59

This product sheet is a publication from NIBE Energy Systems. All product illustrations,
facts and data are based on current information at the time of the publication’s approval.
NIBE Energy Systems makes reservations for any factual or printing errors in this product
sheet.

©2019 NIBE ENERGY SYSTEMS