Audible Test Direct Pressure Technique: Authorized by

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Audible Test Direct Pressure Technique

Authorized By:

____________________________
Senior Inspector

Methanex Corporation
Medicine Hat, AB

Copy: 01
Revision Date: January 7, 2000
\\mxcmhtnt1\inetpub\wwwroot\procedures\maintenance\inspection\nde\lt-06.doc
TABLE OF CONTENTS
AUDIBLE TEST DIRECT PRESSURE TECHNIQUE

1. LT-06: AUDIBLE TEST DIRECT PRESSURE TECHNIQUE..................................................................3

Uncontrolled copy unless title page has original authorized signature.

Audible Test Direct Pressure Technique


Revision Date: January 7, 2000
Page 2 of 3
1. LT-06: AUDIBLE TEST DIRECT PRESSURE TECHNIQUE

1. Extent of examination: 100% of equipment specified.

2. Equipment:

• Test gas is air _____, N2 _____, Line Commodity _____ = __________.

• Ultraprobe 2000.

3. Surface cleanliness: no special cleaning required.

4. Method or Technique:

• Equipment will be pressurized and in service or out of service and pressurized to normal
operating pressure using compressed air or nitrogen.

Note: Inert gas may be used. Safety aspects of oxygen deficient atmospheres should
be considered.

• Scan equipment being tested as described in the Ultraprobe 2000 literature.

• Focus in on leaks using appropriate fixtures in the Ultraprobe kit.

• Report and map any leaks detected. Consider secondary test methods to confirm leaks.

5. Test is considered acceptable if no leaks are found.

6. No post cleaning required.

7. Where repairs are required the equipment will be depressurized, repaired in accordance with the
applicable code section and the test repeated.

Uncontrolled copy unless title page has original authorized signature.

Audible Test Direct Pressure Technique


Revision Date: January 7, 2000
Page 3 of 3

You might also like