Professional Documents
Culture Documents
SXRL Data Sheet
SXRL Data Sheet
SXRL Data Sheet
APPROVALS
ETA 07/0121
3
Frame & Stand off Installation
Timber sub-structures
INSTALLATION
TECHNICAL DATA
d0
zinc-plated stainless Drill hole Min.drill- Usable length Usable length Usable length Anchor Drive Sales unit
steel steel diameter hole depth at anchorage at anchorage at anchorage length
for through depth 50mm depth 70mm depth 90mm
fixings
do h2 tfix tfix tfix I
Item Art.-N0. Art.-No. (mm) (mm) (mm) (mm) (mm) (mm) (pcs)
gvz A4
SXRL 8 x 60 T 540113 540119 8 70 10 − − 60 T30 50
SXRL 8 x 80 T 540114 540121 8 90 30 10 − 80 T30 50
SXRL 8 x 100 T 540115 540123 8 110 50 30 10 100 T30 50
SXRL 8 x 120 T 540116 540124 8 130 70 50 30 120 T30 50
SXRL 8 x 140 T 540117 540125 8 150 90 70 50 140 T30 50
SXRL 8 x 160 T 540118 540126 8 170 110 90 70 160 T30 50
SXRL 10 x 80 T 522698 522709 10 90 10 10 − 80 T40 50
SXRL 10 x 100 T 522699 522710 10 110 30 30 10 100 T40 50
SXRL 10 x 120 T 522700 522711 10 130 50 50 30 120 T40 50
118
Frame fixing SXRL
TECHNICAL DATA
zinc-plated stainless Drill hole Min.drill- Usable length Usable length Usable length Anchor Drive Sales unit
steel steel diameter hole depth at anchorage at anchorage at anchorage length
for through depth 50mm depth 70mm depth 90mm
fixings
do h2 tfix tfix tfix I
Item Art.-N0. Art.-No. (mm) (mm) (mm) (mm) (mm) (mm) (pcs)
gvz A4
SXRL 10 x 140 T 522701 522712 10 150 70 70 50 140 T40 50
SXRL 10 x 160 T 522703 522713 10 170 90 90 70 160 T40 50
SXRL 10 x 180 T 522704 522714 10 190 110 110 90 180 T40 50 3
SXRL 10 x 200 T 522705 522715 10 210 130 130 110 200 T40 50
SXRL 10 x 230 T 522706 522716 10 240 160 160 140 230 T40 50
do
SXRL - FUS - with fischer hexagon head safety
screw, moulded washer and integrated bit recess
hef t fix
I
h2
zinc-plated stainless Drill hole Min.drill- Usable length Usable length Usable length Anchor Drive Sales unit
steel steel diameter hole depth at anchorage at anchorage at anchorage length
for through depth 50mm depth 70mm depth 90mm
fixings
do h2 tfix tfix tfix I
Item Art.-N0. Art.-No. (mm) (mm) (mm) (mm) (mm) (mm) (pcs)
gvz A4
SXRL 8 x 60 FUS 540127 540135 8 70 10 − − 60 T30/SW 10 50
SXRL 8 x 80 FUS 540129 540136 8 90 30 10 − 80 T30/SW 10 50
SXRL 8 x 100 FUS 540130 540137 8 110 50 30 10 100 T30/SW 10 50
SXRL 8 x 120 FUS 540131 − 8 130 70 50 30 120 T30/SW 10 50
SXRL 8 x 140 FUS 540133 − 8 150 90 70 50 140 T30/SW 10 50
SXRL 8 x 160 FUS 540134 − 8 170 110 90 70 160 T30/SW 10 50
SXRL10 x 80 FUS 522719 522730 10 90 10 10 − 80 T40/SW 13 50
SXRL10 x 100 FUS 522720 522731 10 110 30 30 10 100 T40/SW 13 50
SXRL10 x 120 FUS 522721 522732 10 130 50 50 30 120 T40/SW 13 50
SXRL10 x 140 FUS 522723 522733 10 150 70 70 50 140 T40/SW 13 50
SXRL10 x 160 FUS 522724 522734 10 170 90 90 70 160 T40/SW 13 50
SXRL10 x 180 FUS 522725 522735 10 190 110 110 90 180 T40/SW 13 50
SXRL10 x 200 FUS 522726 522736 10 210 130 130 110 200 T40/SW 13 50
SXRL10 x 230 FUS 522727 522737 10 240 160 160 140 230 T40/SW 13 50
SXRL10 x 260 FUS 522728 522738 10 270 190 190 170 260 T40/SW 13 50
SXRL10 x 290 FUS 522729 522739 10 300 220 220 200 290 T40/SW 13 50
SXRL 14 x 80 FUS 530946 530955 14 95 10 10 − 80 T50/SW 17 50
SXRL 14 x 100 FUS 530947 530956 14 115 30 30 10 100 T50/SW 17 50
SXRL 14 x 120 FUS 530948 530957 14 135 50 50 30 120 T50/SW 17 50
SXRL 14 x 140 FUS 530949 530958 14 155 70 70 50 140 T50/SW 17 50
SXRL 14 x 160 FUS 530950 530959 14 175 90 90 70 160 T50/SW 17 50
SXRL 14 x 180 FUS 530951 530960 14 195 110 110 90 180 T50/SW 17 50
SXRL 14 x 200 FUS 530952 530961 14 215 130 130 110 200 T50/SW 17 50
SXRL 14 x 230 FUS 530953 530962 14 245 160 160 140 230 T50/SW 17 50
SXRL 14 x 260 FUS 530954 530963 14 275 190 190 170 260 T50/SW 17 50
(1) Not preassembled.
119
Frame fixing SXRL
ACCESSORIES
lS
d0
dS
SXRL - without screw
hef t fix
l
h2
3
Drill hole Min.drill- Usable length Usable length Usable length Anchor Screw Min. Sales unit
diameter hole depth at anchorage at anchorage at anchorage length Diameter screw
Frame & Stand off Installation
LOADS
3)
Frame fixing SXRL
1)
Highest recommended loads for a single anchor as part of a multiple fixing of non-structural systems.
The given loads are valid for wood screws with the specified diameter.
Type SXRL 8
LOADS
Loads¹⁾ for a single anchor for multiple fixing of non-structural application in normal concrete ≥ C12/15 resp ≥ B15. For the
design the complete approval ETA-07/0121 has to be considered.
Load in Cracked or Non-cracked concrete
Anchorage Min. member Tensile load ³⁾ Shear load ⁸⁾ Min. Min. edge
depth thickness Design Recommended Design Recommended spacing distance
hnom hmin Nd Nrec ¹⁾ Vd ⁵⁾ Vrec ³⁾ ¹⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (mm) (mm) (kN) (kN) (kN) (kN) (mm) (mm)
gvz A4 gvz A4
SXRL 8 50 80 2.22 1.59 5.92 5.50 4.23 3.93 85 85
SXRL 8 70 100 2.77 1.98 5.92 5.50 4.23 3.93 85 85
SXRL 8 90 120 2.77 1.98 5.92 5.50 4.23 3.93 85 85
SXRL 10 50 100 2.77 1.98 8.37 8.37 5.98 5.98 70 70
SXRL 10 70 100 3.61 2.58 8.37 8.37 5.98 5.98 70 70
SXRL 10 90 120 3.61 2.58 8.37 8.37 5.98 5.98 70 70
SXRL 14 70 110 4.71 3.37 17.36 16.28 12.40 11.63 85 85
SXRL 14 90 130 4.71 3.37 17.36 16.28 12.40 11.63 85 85
(1) The required partial safety factors for material resistance as well as a partial saf- (4) The required saftey factor for material is considered.
ety factor for load actions L= 1,4 are considered. (5) The permissible shear load determined acc. ETAG 020, Annex C considers
(2) Minimum possible axial spacings (anchor group) resp. edge distance while red- exclusively steel failure of the screw(A4). due to that the expected displacements
ucing the permissible load. The combination of the given min. spacing and min. will disable the proper function of the fixture a maximum shear load on the basis
edge distance is not possible. One of them has to be increased according approval. of table 7 of the approval is recommended.
(3) Valid for tensile load, shear load and oblique load under any angle. For combin-
ations of tensile loads, shear loads and bending moments see approval.
120
Frame fixing SXRL
LOADS
Load capacity for SXR-L screws
Screw Data
Design Tension load Design Shear load Design Bending capacity MRKS
Item Screw Dia (kN) (kN) (Nm)
(mm) gvz A4 gvz A4 gvz A4
SXRL 8 6 9.8 9.8 5.9 5.5 9.9 9.3
SXRL 10 7 14.0 14.0 8.4 8.4 16.5 16.5
SXRL 14 9.6 28.9 27.1 17.4 16.3 39.0 36.4
3
Loads ⁶⁾ for a single anchor for multiple fixings of non-structural applications in masonry. For the design the complete approval
Loads ⁶⁾ for a single anchor for multiple fixings of non-structural applications in masonry. For the design the complete approval
ETA-07/0121 has to be considered
Brick Brick type, Min. Min. member Design Recommended Min.spacing Min.edge
Compressive strength naming anchorage depth thickness load load distance
fb acc. DIN hnom (hv) hmin F d ³⁾ ⁵⁾ Frec ³⁾ ⁵⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (N/mm2) (-) (mm) (mm) (kN) (kN) (mm) (mm)
Solid Brick Mz
SXRL 10 ≥20 Mz 70 110 1.60 1.14 100 100
SXRL 10 ≥28 Mz 70 110 2.20 1.57 100 100
Solid sand-line brick and solid block KS
SXRL 10 ≥12 KS 70 110 2.60 1.86 100 100
Vertically perforated brick Hlz
SXRL 10 ≥20 HIz 70 110 0.48 0.34 100 100
Perforated sand-line brick KSL
SXRL 10 ≥20 KSL 70 110 1.40 1.00 100 100
Hollow block of lightweight aggregate concrete HbI
SXRL 10 ≥6 HbI 70 110 0.60 0.43 7 100 100
SXRL 10 ≥10 HbI 70 110 1.00 0.71 7 100 100
Solid brick and solid block of lightweight aggregate concrete V
SXRL 10 ≥2 V 70 100 0.48 0.34 100 100
Aerated concrete blocks and reinforced panels AAC
SXRL 10 ≥2 AAC 90 175 0.45 0.32 200 100
SXRL 10 ≥6 AAC 90 175 2.00 1.43 200 100
Loads1) 6) for a single anchor for multiple fixings of non-structural applications in masonry. For the design the complete approval
ETA-14/0297 has to be considered
Brick Brick type, Bulk Min.brick Min. Mni. member Design Recommended Min. Min. edge
Compressive strength naming density formate anchorage depth thickness load load spacing distance
fb acc. DIN P (L x W x H) hnom (hv) hmin Fd ³⁾ ⁵⁾ ⁸⁾ Frec ³⁾ ⁵⁾ ¹⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (N/mm2) (-) (kg/m³) (mm) (mm) (kN) (kN) (kN) (mm) (mm)
Solid Brick Mz acc DIN 105-100:2012-01, EN 771-1:2011
SXRL 14 ≥10 Mz 1.20 0.86 100 100
SXRL 14 ≥10 Mz 1.81 1.29 100 200
≥1.8 NF (240 x 113 x 71) 70 115
SXRL 14 ≥20 Mz 1.60 1.14 100 100
SXRL 14 ≥20 Mz 2.39 1.71 100 200
Solid sand-lime brick KS acc. DIN V 106, DIN EN 771-2
SXRL 14 ≥10 KS NF (240 x 113 x 71) 70 115 1.20 0.86 100 100
121
Accessories (SXR, SXRL, SXS)
Loads1) 6) for a single anchor for multiple fixings of non-structural applications in masonry. For the design the complete approval
ETA-14/0297 has to be considered
Brick Brick type, Bulk Min.brick Min. Mni. member Design Recommended Min. Min. edge
Compressive strength naming density formate anchorage depth thickness load load spacing distance
fb acc. DIN P (L x W x H) hnom (hv) hmin Fd ³⁾ ⁵⁾ ⁸⁾ Frec ³⁾ ⁵⁾ ¹⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (N/mm2) (-) (kg/m³) (mm) (mm) (kN) (kN) (kN) (mm) (mm)
SXRL 14 ≥10 KS 1.40 1.00 100 200
≥1.8 NF (240 x 113 x 71) 70 115
SXRL 14 ≥20 KS 1.81 1.29 100 100
SXRL 14 ≥20 KS 2.00 1.43 100 200
SXRL 14 ≥8 KS 0.80 0.57 100 100
SXRL 14 ≥8 KS ≥1.8 2.20 1.57 100 200
2 DF (240 x 115 x 113) 70 115
SXRL 14 ≥12 KS 1.40 1.00 100 100
3 SXRL 14 ≥12 KS
≥2.0
3.40 2.43 100 200
Solid brick of lightweight aggregate concrete V acc. DIN 18152-100, DIN EN 771-3