SXRL Data Sheet

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Frame fixing SXRL

The powerful problem solver with multiple anchorage depths

APPROVALS

ETA 07/0121

3
Frame & Stand off Installation

Timber sub-structures

ADVANTAGES BUILDING MATERIALS


Approved for: Also suitable for:
Through the special geometry of the plug, the loads are
Vertically perforated brick Natural stone with dense
evenly distributed in the drill hole.
Aerated concrete structure
When the plug is to be set below the plaster, the longer ribs
Hollow blocks made from Solid panel made from
prevent plug rotation during installation.
lightweight concrete gypsum
Multiple anchorage depths of 50, 70 or 90 mm for SXRL 8 and
SXRL 10 and 70 or 90 mm for SXRL 14 making SXRL a versatile Perforated sand-lime brick VERSIONS
product. Thermal insulation blocks
Zinc-plated steel
When anchoring in hollow and solid construction materials, Solid block made from
Stainless steel
the two expansion zones lead to optimum retention values. lightweight and normal
Complete range available with diameters of 8, 10 and weight concrete
14mm with usable lengths up to 290 mm provides the Solid brick
right plug for every application. Solid sand-lime brick
Available with two types of heads. Concrete ≥ C12/15

INSTALLATION

TECHNICAL DATA
d0

SXRL-T- with fischer countersunk head


safety screw hef t fix
l
h2

zinc-plated stainless Drill hole Min.drill- Usable length Usable length Usable length Anchor Drive Sales unit
steel steel diameter hole depth at anchorage at anchorage at anchorage length
for through depth 50mm depth 70mm depth 90mm
fixings
do h2 tfix tfix tfix I
Item Art.-N0. Art.-No. (mm) (mm) (mm) (mm) (mm) (mm) (pcs)
gvz A4
SXRL 8 x 60 T 540113 540119 8 70 10 − − 60 T30 50
SXRL 8 x 80 T 540114 540121 8 90 30 10 − 80 T30 50
SXRL 8 x 100 T 540115 540123 8 110 50 30 10 100 T30 50
SXRL 8 x 120 T 540116 540124 8 130 70 50 30 120 T30 50
SXRL 8 x 140 T 540117 540125 8 150 90 70 50 140 T30 50
SXRL 8 x 160 T 540118 540126 8 170 110 90 70 160 T30 50
SXRL 10 x 80 T 522698 522709 10 90 10 10 − 80 T40 50
SXRL 10 x 100 T 522699 522710 10 110 30 30 10 100 T40 50
SXRL 10 x 120 T 522700 522711 10 130 50 50 30 120 T40 50

118
Frame fixing SXRL

TECHNICAL DATA

zinc-plated stainless Drill hole Min.drill- Usable length Usable length Usable length Anchor Drive Sales unit
steel steel diameter hole depth at anchorage at anchorage at anchorage length
for through depth 50mm depth 70mm depth 90mm
fixings
do h2 tfix tfix tfix I
Item Art.-N0. Art.-No. (mm) (mm) (mm) (mm) (mm) (mm) (pcs)
gvz A4
SXRL 10 x 140 T 522701 522712 10 150 70 70 50 140 T40 50
SXRL 10 x 160 T 522703 522713 10 170 90 90 70 160 T40 50
SXRL 10 x 180 T 522704 522714 10 190 110 110 90 180 T40 50 3
SXRL 10 x 200 T 522705 522715 10 210 130 130 110 200 T40 50
SXRL 10 x 230 T 522706 522716 10 240 160 160 140 230 T40 50

Frame & Stand off Installation


SXRL 10 x 260 T 522707 ¹⁾ 522717 ¹⁾ 10 270 190 190 170 260 T40 50
SXRL 10 x 290 T 522708 ¹⁾ 522718 ¹⁾ 10 300 220 220 200 290 T50 50
SXRL 14 x 80 T 530920 530932 14 95 10 10 − 80 T50 50
SXRL 14 x 100 T 530921 530933 14 115 30 30 10 100 T50 50
SXRL 14 x 120 T 530922 530934 14 135 50 50 30 120 T50 50
SXRL 14 x 140 T 530923 530935 14 155 70 70 50 140 T50 50
SXRL 14 x 160 T 530924 530936 14 175 90 90 70 160 T50 50
SXRL 14 x 180 T 530925 530937 14 195 110 110 90 180 T50 50
SXRL 14 x 200 T 530926 530938 14 215 130 130 110 200 T50 50
SXRL 14 x 230 T 530927 530939 14 245 160 160 140 230 T50 50
SXRL 14 x 260 T 530928 530940 14 275 190 190 170 260 T50 50
SXRL 14 x 300 T 530929 ¹⁾ 530941 ¹⁾ 14 315 230 230 210 300 T50 50
SXRL 14 x 330 T 530930 ¹⁾ 530942 ¹⁾ 14 345 260 260 240 330 T50 20
SXRL 14 x 360 T 530931 ¹⁾ 530943 ¹⁾ 14 375 290 290 270 360 T50 20
(1) Not preassembled.

do
SXRL - FUS - with fischer hexagon head safety
screw, moulded washer and integrated bit recess
hef t fix
I
h2

zinc-plated stainless Drill hole Min.drill- Usable length Usable length Usable length Anchor Drive Sales unit
steel steel diameter hole depth at anchorage at anchorage at anchorage length
for through depth 50mm depth 70mm depth 90mm
fixings
do h2 tfix tfix tfix I
Item Art.-N0. Art.-No. (mm) (mm) (mm) (mm) (mm) (mm) (pcs)
gvz A4
SXRL 8 x 60 FUS 540127 540135 8 70 10 − − 60 T30/SW 10 50
SXRL 8 x 80 FUS 540129 540136 8 90 30 10 − 80 T30/SW 10 50
SXRL 8 x 100 FUS 540130 540137 8 110 50 30 10 100 T30/SW 10 50
SXRL 8 x 120 FUS 540131 − 8 130 70 50 30 120 T30/SW 10 50
SXRL 8 x 140 FUS 540133 − 8 150 90 70 50 140 T30/SW 10 50
SXRL 8 x 160 FUS 540134 − 8 170 110 90 70 160 T30/SW 10 50
SXRL10 x 80 FUS 522719 522730 10 90 10 10 − 80 T40/SW 13 50
SXRL10 x 100 FUS 522720 522731 10 110 30 30 10 100 T40/SW 13 50
SXRL10 x 120 FUS 522721 522732 10 130 50 50 30 120 T40/SW 13 50
SXRL10 x 140 FUS 522723 522733 10 150 70 70 50 140 T40/SW 13 50
SXRL10 x 160 FUS 522724 522734 10 170 90 90 70 160 T40/SW 13 50
SXRL10 x 180 FUS 522725 522735 10 190 110 110 90 180 T40/SW 13 50
SXRL10 x 200 FUS 522726 522736 10 210 130 130 110 200 T40/SW 13 50
SXRL10 x 230 FUS 522727 522737 10 240 160 160 140 230 T40/SW 13 50
SXRL10 x 260 FUS 522728 522738 10 270 190 190 170 260 T40/SW 13 50
SXRL10 x 290 FUS 522729 522739 10 300 220 220 200 290 T40/SW 13 50
SXRL 14 x 80 FUS 530946 530955 14 95 10 10 − 80 T50/SW 17 50
SXRL 14 x 100 FUS 530947 530956 14 115 30 30 10 100 T50/SW 17 50
SXRL 14 x 120 FUS 530948 530957 14 135 50 50 30 120 T50/SW 17 50
SXRL 14 x 140 FUS 530949 530958 14 155 70 70 50 140 T50/SW 17 50
SXRL 14 x 160 FUS 530950 530959 14 175 90 90 70 160 T50/SW 17 50
SXRL 14 x 180 FUS 530951 530960 14 195 110 110 90 180 T50/SW 17 50
SXRL 14 x 200 FUS 530952 530961 14 215 130 130 110 200 T50/SW 17 50
SXRL 14 x 230 FUS 530953 530962 14 245 160 160 140 230 T50/SW 17 50
SXRL 14 x 260 FUS 530954 530963 14 275 190 190 170 260 T50/SW 17 50
(1) Not preassembled.

119
Frame fixing SXRL

ACCESSORIES
lS

d0

dS
SXRL - without screw
hef t fix
l
h2

3
Drill hole Min.drill- Usable length Usable length Usable length Anchor Screw Min. Sales unit
diameter hole depth at anchorage at anchorage at anchorage length Diameter screw
Frame & Stand off Installation

for through depth 50mm depth 70mm depth 90mm length


fixings
do h2 tfix tfix tfix I ds ls
Item Art.-No. (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (pcs)
SXRL 8 x 60 540879 8 70 10 − − 60 5.5 - 6.0 65 100
SXRL 8 x 80 540880 8 90 30 10 − 80 5.5 - 6.0 85 100
SXRL 8 x 100 540881 8 110 50 30 10 100 5.5 - 6.0 105 100
SXRL 8 x 120 540882 8 130 70 50 30 120 5.5 - 6.0 125 100

LOADS
3)
Frame fixing SXRL
1)
Highest recommended loads for a single anchor as part of a multiple fixing of non-structural systems.
The given loads are valid for wood screws with the specified diameter.

Type SXRL 8

Anchorage depth hnom [mm] 50 70 90


Screw diameter Ø [mm] 6.0 6.0 6.0
Min. edge distance concrete ar [mm] 60 80 100
Recommended loads in the respective base material Frec
Concrete ≥ C20/25 [kN] 0.60 1.00 1.00
Solid brick ≥ Mz 12 [kN] 0.45 0.60 0.60
Solid sand-line brick ≥ KS 12 [kN] 0.40 0.50 0.50
Vertically perforated brick ≥ Hlz 12 (ρ ≥ 1,0 kg/dm3) [kN] 0.15 0.15 0.15
Perforated sand-line brick ≥ KSL 12 [kN] 0.10 0.40 0.40
Aerated concrete AAC 2 [kN] − 0.10 0.10
Aerated concrete AAC 4 [kN] − 0.15 0.20
(1) Required safety factors are considered.
(2) Valid for tensile load, shear load and oblique load under any angle.
(3) Valid for zinc coated screws and for screws made of stainless steel. For exterior use of the zinc coated screws measures against incoming humidity have to be taken.

LOADS

Loads¹⁾ for a single anchor for multiple fixing of non-structural application in normal concrete ≥ C12/15 resp ≥ B15. For the
design the complete approval ETA-07/0121 has to be considered.
Load in Cracked or Non-cracked concrete
Anchorage Min. member Tensile load ³⁾ Shear load ⁸⁾ Min. Min. edge
depth thickness Design Recommended Design Recommended spacing distance
hnom hmin Nd Nrec ¹⁾ Vd ⁵⁾ Vrec ³⁾ ¹⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (mm) (mm) (kN) (kN) (kN) (kN) (mm) (mm)
gvz A4 gvz A4
SXRL 8 50 80 2.22 1.59 5.92 5.50 4.23 3.93 85 85
SXRL 8 70 100 2.77 1.98 5.92 5.50 4.23 3.93 85 85
SXRL 8 90 120 2.77 1.98 5.92 5.50 4.23 3.93 85 85
SXRL 10 50 100 2.77 1.98 8.37 8.37 5.98 5.98 70 70
SXRL 10 70 100 3.61 2.58 8.37 8.37 5.98 5.98 70 70
SXRL 10 90 120 3.61 2.58 8.37 8.37 5.98 5.98 70 70
SXRL 14 70 110 4.71 3.37 17.36 16.28 12.40 11.63 85 85
SXRL 14 90 130 4.71 3.37 17.36 16.28 12.40 11.63 85 85
(1) The required partial safety factors for material resistance as well as a partial saf- (4) The required saftey factor for material is considered.
ety factor for load actions L= 1,4 are considered. (5) The permissible shear load determined acc. ETAG 020, Annex C considers
(2) Minimum possible axial spacings (anchor group) resp. edge distance while red- exclusively steel failure of the screw(A4). due to that the expected displacements
ucing the permissible load. The combination of the given min. spacing and min. will disable the proper function of the fixture a maximum shear load on the basis
edge distance is not possible. One of them has to be increased according approval. of table 7 of the approval is recommended.
(3) Valid for tensile load, shear load and oblique load under any angle. For combin-
ations of tensile loads, shear loads and bending moments see approval.

120
Frame fixing SXRL

LOADS
Load capacity for SXR-L screws
Screw Data

Design Tension load Design Shear load Design Bending capacity MRKS
Item Screw Dia (kN) (kN) (Nm)
(mm) gvz A4 gvz A4 gvz A4
SXRL 8 6 9.8 9.8 5.9 5.5 9.9 9.3
SXRL 10 7 14.0 14.0 8.4 8.4 16.5 16.5
SXRL 14 9.6 28.9 27.1 17.4 16.3 39.0 36.4
3
Loads ⁶⁾ for a single anchor for multiple fixings of non-structural applications in masonry. For the design the complete approval

Frame & Stand off Installation


ETA-07/0121 has to be considered
Brick Brick type, Anchorage Min. member Design Recommended Min.spacing Min.edge
Compressive strength naming depth thickness load load distance
fb acc. DIN hnom hmin F d ³⁾ ⁵⁾ Frec ³⁾ ⁵⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (N/mm2) (-) (mm) (mm) (kN) (kN) (mm) (mm)
Solid Brick Mz
SXRL 8 ≥12 Mz 70 115 1.00 0.71 100 100
SXRL 8 ≥20 Mz 70 115 1.60 1.14 100 100
Solid sand-lime brick and solid block KS
SXRL 8 ≥20 KS 70 115 1.20 0.86 100 100
Vertically perforated brick Hlz
SXRL 8 ≥10 HIz 70 115 0.24 0.17 100 100
Perforated sand-lime brick KSL
SXRL 8 ≥12 KSL 70 115 0.60 0.43 100 100
Hollow block of lightweight aggregate concrete HbI
SXRL 8 ≥2 HBL 70 115 0.80 0.57 100 100
SXRL 8 ≥6 HBL 70 115 1.00 0.71 100 100
Lightweight concrete block V
SXRL 8 ≥6 V 70 115 0.80 0.57 100 100
Aerated concrete blocks and reinforced panels AAC
SXRL 8 ≥4 AAC 70 175 0.60 0.43 110 110
SXRL 8 ≥6 AAC 70 175 1.00 0.71 110 110

Loads ⁶⁾ for a single anchor for multiple fixings of non-structural applications in masonry. For the design the complete approval
ETA-07/0121 has to be considered
Brick Brick type, Min. Min. member Design Recommended Min.spacing Min.edge
Compressive strength naming anchorage depth thickness load load distance
fb acc. DIN hnom (hv) hmin F d ³⁾ ⁵⁾ Frec ³⁾ ⁵⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (N/mm2) (-) (mm) (mm) (kN) (kN) (mm) (mm)
Solid Brick Mz
SXRL 10 ≥20 Mz 70 110 1.60 1.14 100 100
SXRL 10 ≥28 Mz 70 110 2.20 1.57 100 100
Solid sand-line brick and solid block KS
SXRL 10 ≥12 KS 70 110 2.60 1.86 100 100
Vertically perforated brick Hlz
SXRL 10 ≥20 HIz 70 110 0.48 0.34 100 100
Perforated sand-line brick KSL
SXRL 10 ≥20 KSL 70 110 1.40 1.00 100 100
Hollow block of lightweight aggregate concrete HbI
SXRL 10 ≥6 HbI 70 110 0.60 0.43 7 100 100
SXRL 10 ≥10 HbI 70 110 1.00 0.71 7 100 100
Solid brick and solid block of lightweight aggregate concrete V
SXRL 10 ≥2 V 70 100 0.48 0.34 100 100
Aerated concrete blocks and reinforced panels AAC
SXRL 10 ≥2 AAC 90 175 0.45 0.32 200 100
SXRL 10 ≥6 AAC 90 175 2.00 1.43 200 100

Loads1) 6) for a single anchor for multiple fixings of non-structural applications in masonry. For the design the complete approval
ETA-14/0297 has to be considered
Brick Brick type, Bulk Min.brick Min. Mni. member Design Recommended Min. Min. edge
Compressive strength naming density formate anchorage depth thickness load load spacing distance
fb acc. DIN P (L x W x H) hnom (hv) hmin Fd ³⁾ ⁵⁾ ⁸⁾ Frec ³⁾ ⁵⁾ ¹⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (N/mm2) (-) (kg/m³) (mm) (mm) (kN) (kN) (kN) (mm) (mm)
Solid Brick Mz acc DIN 105-100:2012-01, EN 771-1:2011
SXRL 14 ≥10 Mz 1.20 0.86 100 100
SXRL 14 ≥10 Mz 1.81 1.29 100 200
≥1.8 NF (240 x 113 x 71) 70 115
SXRL 14 ≥20 Mz 1.60 1.14 100 100
SXRL 14 ≥20 Mz 2.39 1.71 100 200
Solid sand-lime brick KS acc. DIN V 106, DIN EN 771-2
SXRL 14 ≥10 KS NF (240 x 113 x 71) 70 115 1.20 0.86 100 100

121
Accessories (SXR, SXRL, SXS)

Loads1) 6) for a single anchor for multiple fixings of non-structural applications in masonry. For the design the complete approval
ETA-14/0297 has to be considered
Brick Brick type, Bulk Min.brick Min. Mni. member Design Recommended Min. Min. edge
Compressive strength naming density formate anchorage depth thickness load load spacing distance
fb acc. DIN P (L x W x H) hnom (hv) hmin Fd ³⁾ ⁵⁾ ⁸⁾ Frec ³⁾ ⁵⁾ ¹⁾ Smin ²⁾ Cmin ²⁾
Item⁴ (N/mm2) (-) (kg/m³) (mm) (mm) (kN) (kN) (kN) (mm) (mm)
SXRL 14 ≥10 KS 1.40 1.00 100 200
≥1.8 NF (240 x 113 x 71) 70 115
SXRL 14 ≥20 KS 1.81 1.29 100 100
SXRL 14 ≥20 KS 2.00 1.43 100 200
SXRL 14 ≥8 KS 0.80 0.57 100 100
SXRL 14 ≥8 KS ≥1.8 2.20 1.57 100 200
2 DF (240 x 115 x 113) 70 115
SXRL 14 ≥12 KS 1.40 1.00 100 100
3 SXRL 14 ≥12 KS
≥2.0
3.40 2.43 100 200
Solid brick of lightweight aggregate concrete V acc. DIN 18152-100, DIN EN 771-3
Frame & Stand off Installation

SXRL 14 ≥2 V ≥1.2 0.48 0.34 100 100


SXRL 14 ≥6 V 0.80 0.57 100 100
SXRL 14 ≥6 V ≥1.6 250 x 240 x 245 70 115 1.81 1.29 100 200
SXRL 14 ≥10 V 1.40 1.00 100 100
SXRL 14 ≥10 V 2.80 2.00 100 200
Vertically perforated brick HIz acc. DIN 105-100:2012-01, DIN EN 771-1:2011
SXRL 14 ≥6 HIz 0.48 0.34⁵⁾ 100 100
SXRL 14 ≥8 HIz 70 115 0.60 0.43 ⁵⁾ 100 100
≥1.0 3 DF (240 x 175 x 113)
SXRL 14 ≥10 HIz 0.80 0.57 ⁵⁾ 100 100
SXRL 14 ≥12 HIz 0.80 0.57 ⁵⁾ 100 100
Perforated sand-lime brick KSL acc. DIN V 106, DIN EN 771-2
SXRL 14 ≥6 KSL 0.48 0.34 100 100
SXRL 14 ≥8 KSL 0.60 0.43 100 100
2 DF (240 x 115 x 113)
SXRL 14 ≥10 KSL ≥1.4 70 115 0.80 0.57 100 100
SXRL 14 ≥10 KSL 0.80 0.57 100 100
9 DF (340 x 175 x 240)
SXRL 14 ≥20 KSL 0.60 1.14 100 100
Hollow brick of lightweight aggregate concrete HbI acc. DIN V 18153-100, EN 771-3
SXRL 14 ≥0.7 HbI ≥2.0 240 x 500 x 240 ⁷⁾ 70 115 0.60 0.43 ⁵⁾ 100 100
Aerated concrete blocks acc. DIN V 4165-100:2005-10, EN 771-4 and reinforced wall panels acc. EN 12602, DIN 4223
SXRL 14 ≥2 AAC 70 175 0.45 0.32 80 80
SXRL 14 ≥2 AAC 90 175 2.00 0.43 80 80
--- --- 300
SXRL 14 ≥6 AAC 70 0.45 1.43 80 100
SXRL 14 ≥6 AAC 90 300 2.00 1.80 100 120
(1) The required partial safety factors for material resistance as well as a partial (5) The given values for hollow or perforated masonry apply for rotary drilling (witho-
safety factor for load actions F = 1,4 are considered. ut impact). The given loads are reference values which may change due to type of
(2) Minimum possible axial spacings (anchor group) resp. edge distance while red- brick and manufacturer.
ucing the permissible load. The combination of the given min. spacing and min. (6) Valid for temperatures in the substrate up to +50°C (resp. short term up to 80°C).
edge distance is not possible. One of them has to be increased according approval. For long term temperatures up to 30°C higher permissible loads in solid and hollow
(3) Valid for tensile load, shear load and oblique load under any angle. For combin- bricks may be possible.
ations of tensile loads, shear loads and bending moments see approval. (7) Thickness of outer web 50 mm.
(4) Valid for zinc coated screws and for screws made of stainless steel. (8) The required safety factor for material is considered.

ACCESSORIES (SXR, SXRL, SXS)

Cover cap ADT Washer U stainless steel A2


Cap Fits safety screw with seat Sales unit External Hole Ø Thickness Fits anchor Sales unit
Item Art-No. Colour (Ø mm) ITX-Star recess (pcs) d S
Item Art-No. (mm) (Ø mm) (mm) (pcs)
ADT 15 W 060326 White 15 40 100
ADT 15 DB 060329 Dark Brown 15 40 100 U 11,5 x 21 x 1,5 SXR 10, FUR 10,
ADT 18 W 060334 White 18 40 100 010026 21 11.5 1.5 500
DIN 522 A2 SXS 10
ADT 18 DB 060337 Dark Brown 18 40 100

Aircrete hole punch GBS


Drill-hole Min. drill hole Fits Sales unit
depth for
through fixing
do h2
Item Art-No. (mm) (mm) (pcs)
GBS 10 x 80 050590 9 85 SXR 10 x 52, SXR 10 x 60, SXR 10 x 80 1
GBS 10 x 100 050591 9 105 SXR 10 x 100 1
GBS 10 x 135 050593 9 140 SXR 10 x 120 1
GBS 10 x 160 050594 9 165 SXR 10 x 140, SXR 10 x 160 1
GBS 10 x 185 050595 9 190 SXR 10 x 180 1
GBS 10 x 230 050596 9 235 SXR 10 x 200, SXR 10 x 230 1

122

You might also like