Technical Data of Sperre Air Compressors 50MW HFO Power Plant
Technical Data of Sperre Air Compressors 50MW HFO Power Plant
OB-Q208960/19-R2
Page : 4
Built-in accessories:
Air suction filter with silencer
Inter- and aftercooler
Pressure transmitter LP and HP alarm & shut down
Temperature transmitter HT alarm & shut down
Oil level transmitter alarm & shut down
Solenoid drain valve HP
Non return valve
Oil & water separator
46221 6 Vibration damper
47921S 2 Cover Complete 060-090 Silver
40633 2 Safety valve 33 Barg
40608 2 Safety valve 8 Barg
64310 2 Coil valve 220VAC 50/60Hz
20811 2 Support El-mot. XAW060-090 180
61428H210 2 Electric motor framesize: 180L
Shaft diameter:Ø48 - IE2
Power 21,3 kW, Speed 1450 RPM
Primary voltage 400 V, Frequency 50 Hz
Protection IP-55, Insulation class F
80320 1 Baseplate for 2 x XAW060-090
80320A 1 Starter stand, tubes, fittings
Z32900000 2 Control Cabinet 30-40/40 3-4 DOL
- 7" Touch interface
- DOL start
- Pilot transformer
- Ampermeter
- Common alarm & shutdown
64403-2 2 Signal cable M23-M23 3M
Delivered loose:
64130 2 Transmitter, receiver pressure
79741 1 Seaworthy packing
Design
No. of cylinders / Cylinder arrangement 2 / 90°V
No. of compression stages 2
Cooling Air cooled
Valve LP / Valve HP 1 Plate valve / 1 Reed valve
Operation parameters
Delivery pressure 30 barg
Start – stop pressure 25 - 30 barg Alarm at 31 barg, shutdown at 32 barg
Max. ambient temp. compressor 55°C
Max. ambient temp. controller 55°C (fan needed above 50°C)
Max. ambient temp. electric motor 45°C (55°C on request)
Air outlet temperature Approx 25°C above ambient
Max. noise level 95 dBA (1800 rpm) Below the IMO norm of 110 dBA
Max. vibration level / Min. isolation grade 15 mm/s-RMS / 90 % Gen. rec. 30 mm/s -RMS / 70%
Safety valve LP / HP 8 barg / 33 barg
Rotation Counter clockwise (compressor front)
Mechanical components
Non return valve air outlet Integrated
Oil & water separator HP Integrated
Safety valve LP / HP Integrated
Oil level sight glass Integrated
Air suction filter Integrated
Inter- and after-cooler Integrated
Three vibration isolators Integrated
One lifting lug Integrated
Flexible tube air outlet Loose
Flexible tube drain /unload Loose
Electrical components
Starter with controller Loose
Transmitter LP Integrated Alarm at 6 barg, shutdown at 7 barg
Transmitter HP Integrated Alarm at 31 barg, shutdown at 32 barg
Trans. temp. outlet Integrated Alarm at 85°C, shutdown at 90°C
Transmitter oil level Integrated Alarm 0%, shutdown - 10%, switch - 20%,
temp. switch 100°C
Valve drain / unload HP Integrated