Professional Documents
Culture Documents
Technical Information Micropilot FMR67: Free Space Radar
Technical Information Micropilot FMR67: Free Space Radar
Technical Information Micropilot FMR67: Free Space Radar
Technical Information
Micropilot FMR67
Free space radar
Application
• Continuous, non-contact level measurement of bulk solids
ranging from powdery to lumpy
• PTFE drip-off antenna or PTFE-plated, flush-mounted antenna
• Maximum measuring range: 125 m (410 ft)
• Temperature: –40 to +200 °C (–40 to +392 °F)
• Pressure: –1 to +16 bar (–14.5 to +232 psi)
• Accuracy: ± 3 mm (0.12 in)
• International explosion protection certificates
• Linearity protocol (3-point, 5-point)
Your benefits
• Innovative drip-off antenna made of PTFE for maximum system availability
• Reliable measurement thanks to improved focusing and small beam angle,
particularly in silos with many internal fittings
• Large measuring ranges up to 125 m (410 ft)
• Safety by design - ensures highest safety
• Easy, guided commissioning with intuitive user interface in
local language
• Reliable measurement even in variable product and process conditions
• Maximum reliability thanks to multi-echo tracking
• HistoROM configuration memory makes for easier commissioning,
maintenance and diagnostics
• Antenna design not sensitive to buildup
• Purge air connection for cleaning in extreme conditions
• Alignment device for easy adaptation of sensor
• SIL2 as per IEC 61508, SIL3 for homogeneous or diverse redundancy, 3rd party
approved
• Easy proof testing for SIL
• Seamless integration in process control and asset management systems
• RFID TAG - easy identification of measuring points for improved data access
• Heartbeat Technology
Micropilot FMR67
Table of contents
Mechanical construction . . . . . . . . . . . . . . . . . . . . 40
Function and system design . . . . . . . . . . . . . . . . . . . 8
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Materials: GT18 housing (stainless steel, corrosion-
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 resistant) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Materials: GT19 housing (plastic) . . . . . . . . . . . . . . . . . . 49
Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Materials: GT20 housing (die-cast aluminum, powder-
Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 coated, seawater-resistant) . . . . . . . . . . . . . . . . . . . . . . 50
Transmission power . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Materials: antenna and process connection . . . . . . . . . . . 51
Materials: Weather protection cover . . . . . . . . . . . . . . . . 53
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Linearization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Local operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Galvanic isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Operation with remote display and operating module
Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . 11 FHX50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Remote operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
System integration via Fieldgate . . . . . . . . . . . . . . . . . . . 57
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Device plug connectors . . . . . . . . . . . . . . . . . . . . . . . . . 18 Certificates and approvals . . . . . . . . . . . . . . . . . . . 58
Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . 20 RCM-Tick marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Potential equalization . . . . . . . . . . . . . . . . . . . . . . . . . 20 Dual seal according to ANSI/ISA 12.27.01 . . . . . . . . . . . . 58
Cable entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Functional safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 WHG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Overvoltage protection . . . . . . . . . . . . . . . . . . . . . . . . . 21 Pressure equipment with allowable pressure
≤ 200 bar (2 900 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Marine approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Performance characteristics . . . . . . . . . . . . . . . . . . 23
Radio standard EN 302729-1/2 . . . . . . . . . . . . . . . . . . . 59
Reference operating conditions . . . . . . . . . . . . . . . . . . . 23
Radio standard EN 302372-1/2 . . . . . . . . . . . . . . . . . . . 60
Reference accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
FCC / Industry Canada . . . . . . . . . . . . . . . . . . . . . . . . . 60
Measured value resolution . . . . . . . . . . . . . . . . . . . . . . 23
Test, certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Hard-copy product documentation . . . . . . . . . . . . . . . . . 61
Influence of ambient temperature . . . . . . . . . . . . . . . . . 24
Other standards and guidelines . . . . . . . . . . . . . . . . . . . 62
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Ordering information . . . . . . . . . . . . . . . . . . . . . . . 63
Installation conditions . . . . . . . . . . . . . . . . . . . . . . . . . 25
Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Installation: Drip-off antenna PTFE 50 mm / 2" . . . . . . . . . 29
3-point linearity protocol . . . . . . . . . . . . . . . . . . . . . . . 64
Installation: flush mount antenna . . . . . . . . . . . . . . . . . . 30
5-point linearity protocol . . . . . . . . . . . . . . . . . . . . . . . 65
Purge air connection for FMR67 . . . . . . . . . . . . . . . . . . . 32
Customer-specific configuration . . . . . . . . . . . . . . . . . . . 66
Container with heat insulation . . . . . . . . . . . . . . . . . . . . 33
Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Application Packages . . . . . . . . . . . . . . . . . . . . . . . 67
Ambient temperature range . . . . . . . . . . . . . . . . . . . . . 34
Heartbeat Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . 67
Ambient temperature limits . . . . . . . . . . . . . . . . . . . . . 34
2 Endress+Hauser
Micropilot FMR67
Heartbeat Verification . . . . . . . . . . . . . . . . . . . . . . . . . 68
Heartbeat Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . 69
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . 70
Communication-specific accessories . . . . . . . . . . . . . . . . 76
Service-specific accessories . . . . . . . . . . . . . . . . . . . . . . 77
System components . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Supplementary documentation . . . . . . . . . . . . . . . 78
Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . 78
Safety Instructions (XA) . . . . . . . . . . . . . . . . . . . . . . . . 78
Endress+Hauser 3
Micropilot FMR67
DANGER!
DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in
serious or fatal injury.
WARNING!
WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in
serious or fatal injury.
CAUTION!
CAUTION This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in
minor or medium injury.
NOTE!
NOTICE This symbol contains information on procedures and other facts which do not result in
personal injury.
Preferred
Procedures, processes or actions that are preferred.
Forbidden
Procedures, processes or actions that are forbidden.
Tip
Indicates additional information.
Reference to documentation
A Reference to page
Reference to graphic
Visual inspection
1. , 2. , 3. … Series of steps
A, B, C, ... Views
4 Endress+Hauser
Micropilot FMR67
Symbol Meaning
Hazardous area
- Indicates a hazardous area.
Safety instructions
Observe the safety instructions contained in the associated Operating Instructions.
Endress+Hauser 5
Micropilot FMR67
PN Nominal pressure
FieldCare Scalable software tool for device configuration and integrated plant asset management
solutions
Operating tool The term "operating tool" is used in place of the following operating software:
FieldCare / DeviceCare, for operation via HART communication and PC
6 Endress+Hauser
Micropilot FMR67
Registered trademarks
HART®
Registered trademark of the HART Communication Foundation, Austin, USA
KALREZ®, VITON®
Registered trademark of DuPont Performance Elastomers L.L.C., Wilmington, USA
TEFLON®
Registered trademark of E.I. DuPont de Nemours & Co., Wilmington, USA
Endress+Hauser 7
Micropilot FMR67
D
A0032017
The frequency of this wave is modulated in the form of a sawtooth signal between two limit
frequencies f1 and f2:
f 1
2
f2
Δf
Δt
f1
t
A0023771
This results in the following difference frequency at any time between the transmitted signal and the
received signal:
Δf = k Δt
where Δt is the run time and k is the specified increase in frequency modulation.
Δt is given by the distance D between the reference point R and the product surface:
D = (c Δt) / 2
8 Endress+Hauser
Micropilot FMR67
Input
Measured variable The measured variable is the distance between the reference point and the product surface. The level
is calculated based on "E", the empty distance entered. Optionally, the level can be converted to other
variables (volume, mass) by linearization (32 value pairs).
Endress+Hauser 9
Micropilot FMR67
Output
Output signal HART
Switch output
For HART devices, the switch output is available as an option. See product structure, feature 20:
"Power Supply, Output", option B: "2-wire; 4-20mA HART, switch output"
Devices with PROFIBUS PA and FOUNDATION Fieldbus always have a switch output.
Switch output
Switching behavior Binary (conductive or non-conductive), switches when the programmable switch
point is reached
Insulation voltage floating, Insulation voltage 1 350 VDC to power supply aund 500 VAC to ground
Switch point freely programmable, separately for switch-on and switch-off point
Switching delay freely programmable from 0 to 100 s, separately for switch-on and switch-off
point
Linearization The linearization function of the device allows the conversion of the measured value into any unit of
length or volume. Linearization tables for calculating the volume in cylindrical tanks are pre-
programmed. Other linearization tables of up to 32 value pairs can be entered manually or semi-
automatically.
10 Endress+Hauser
Micropilot FMR67
Galvanic isolation All circuits for the outputs are galvanically isolated from each other.
Manufacturer ID 17 (0x11)
HART device variables The measured values can be freely assigned to the device variables.
Measured values for PV (primary variable)
• Level linearized
• Distance
• Electronic temperature
• Relative echo amplitude
• Area of incoupling
• Analog output adv. diagnostics 1
• Analog output adv. diagnostics 2
Measured values for SV, TV, FV (second, third and fourth variable)
• Level linearized
• Distance
• Electronic temperature
• Terminal voltage
• Relative echo amplitude
• Absolute echo amplitude
• Area of incoupling
• Analog output adv. diagnostics 1
• Analog output adv. diagnostics 2
Start-up time 65 s
Set-up time 15 s
Endress+Hauser 11
Micropilot FMR67
Power supply
Terminal assignment 2-wire: 4-20mA HART
! 2- w
4-2 ire le
0 vel
HA mA
[21 RT
4-2
0m
A ]
ope
A
n Sp
a
711 re pa
HA 20mA
08x rt
xx
RT
4...
+
1 -
1 2 4 5 6
mm
2
10
+ +
–
–
# 4...20 mA
3 B
7 +
1-c 1 -
1 2 4 5 han
nel 4-2 2
ove 0m
[16
] rvo A
ltag
e pro
tec
tion
+ +
–
–
# 4...20 mA
3
A0011294
12 Endress+Hauser
Micropilot FMR67
10
9
8
% 2- w
4-2 ire
0
HA mA
[02 RT
PF
S
A /03
] ope
n Sp
a
711 re pa
HA 20 mA
08x rt
3+ ++ xx
31 --
RT
4...
42 +
7
1 -
mm
2 6
4-
10
+ +
–
-
≥250 Ω 4...20 mA
$
1 2 3 4 5 B
3+ 11 +
3 -
4-2 4
0m +
2-c
A / 1 -
han 4-2 2
4- [17
n el o
v erv FIE 0mA
] olta LD /
ge BU
pro S
tec
tion
+ +
–
-
≥250 Ω 4...20 mA
$
1 2 3 4 5
A0013759
Endress+Hauser 13
Micropilot FMR67
14
13
12
# 2- w
4-2 ire le
0 v el
HA mA
[04 RT
4-2
0m
A /05
]
A
ope
A
n
20m
Sp
a
711 re pa
HA 20mA
08x rt
xx
+
4...
3 -
RT
11
4...
4 +
1 -
mm
2
+ +
10
1 " –
-
4...20 mA
9 8 4
+ +
2 " –
-
4...20 mA
3 5 6 7 4
B
+ +
1 " –
- +
3 -
4...20 mA 4-2 4
10 0m +
9 8 4 2-c
A / 1 -
han
nel 4- 2
[17
ove FIE 20mA
] rvo LD /
ltag
ep
B U
ro S
tec
tion
+ +
2 " –
-
4...20 mA
3 5 6 7 4
A0013923
This version is also suited for single-channel operation. In this case, current output 1 (terminals
1 and 2) must be used.
14 Endress+Hauser
Micropilot FMR67
13
12
11
! 2- w
4-2 ire
0
HA mA
[08 RT
A ]
V=
ope
48
n Sp
4...
a
711 re pa
HA 20 mA
08x rt
10.
L+ xx
1 L-
RT
4...
2 +
10 9
3 -
mm
4 8
10
7
+ !
-
≥250 Ω 4...20 mA
6
1 2 3 4 5
A0011340
Endress+Hauser 15
Micropilot FMR67
13
12
11
! 2- w
4-2 ire
0
HA mA
[09 RT
A ]
~
3V
ope
n
..25
Sp
a
711 re pa
HA 20 mA
90.
08x rt
xx
L
1 N
RT
4...
2 +
10 9
3 -
mm
4 8
10
7
+ !
-
≥250 Ω 4...20 mA
6
1 2 3 4 5
A0018965
LCAUTION
To ensure electrical safety:
‣ Do not disconnect the protective connection (6).
‣ Disconnect the supply voltage before disconnecting the protective earth (7).
Connect protective earth to the internal ground terminal (7) before connecting the supply
voltage. If necessary, connect the potential matching line to the external ground terminal (11).
In order to ensure electromagnetic compatibility (EMC): Do not only ground the device via the
protective earth conductor of the supply cable. Instead, the functional grounding must also be
connected to the process connection (flange or threaded connection) or to the external ground
terminal.
An easily accessible power switch must be installed in the proximity of the device. The power
switch must be marked as a disconnector for the device (IEC/EN61010).
16 Endress+Hauser
Micropilot FMR67
+
3+ 1
2
+ 3+
-
4-
A0015909
4-
8 Connection of a relay A0015910
Endress+Hauser 17
Micropilot FMR67
Device plug connectors For the versions with fieldbus plug connector (M12 or 7/8"), the signal line can be connected
without opening the housing.
2 not connected
1 2 3 Signal -
A0011175
4 Ground
2 Signal +
2 4 3 Not connected
A0011176
4 Screen
18 Endress+Hauser
Micropilot FMR67
A: • Non- 14 to 35 V R [W]
2-wire; hazardous
4-20mA • Ex nA 500
HART • Ex ic
• CSA GP
Ex ia / IS 14 to 30 V
• Ex d(ia) / XP 14 to
• Ex ic(ia) 35 V 3)
• Ex nA(ia) 0
• Ex ta / DIP 10 20 30 35 U0 [V]
14 25
A0031745
Ex ia + Ex d(ia) / 14 to 30 V
IS + XP
B: • Non- 16 to 35 V R [W]
2-wire; hazardous
4-20 mA • Ex nA 500
HART, • Ex nA(ia)
switch • Ex ic
outpu • Ex ic(ia)
• Ex d(ia) / XP
• Ex ta / DIP
• CSA GP
0
• Ex ia / IS 16 to 30 V
U0 [V]
• Ex ia + Ex 10 20 30 35
16 27
d(ia) / IS + XP A0031746
Endress+Hauser 19
Micropilot FMR67
C: All 16 to 30 V R [W]
2-wire;
4-20mA 500
HART,
4-20mA
0
10 20 30 35 U0 [V]
16 27
A0031746
L: 10.4 to 48 VDC
4-wire 10.4-48VDC; 4-20mA HART
Current consumption
HART
Nominal current 3.6 to 22 mA the start-up current for multidrop mode can be parametrized
(is set to 3.6 mA on delivery)
20 Endress+Hauser
Micropilot FMR67
HART
• A normal device cable suffices if only the analog signal is used.
• A shielded cable is recommended if using the HART protocol. Observe grounding concept of the
plant.
• For 4-wire devices: Standard device cable is sufficient for the power line.
Overvoltage protection If the measuring device is used for level measurement in flammable liquids which requires the use of
overvoltage protection according to DIN EN 60079-14, standard for
test procedures 60060-1 (10 kA, pulse 8/20 μs), overvoltage protection has to be ensured by an
integrated or external overvoltage protection module.
Technical data
1) The material of the gland is dependent on the housing type; GT18 (stainless steel housing): 316L (1.4404); GT19 (plastic housing) and GT20
(aluminum housing): nickel-coated brass (CuZn).
Endress+Hauser 21
Micropilot FMR67
22 Endress+Hauser
Micropilot FMR67
Performance characteristics
Reference operating • Temperature = +24 °C (+75 °F) ±5 °C (±9 °F)
conditions • Pressure = 960 mbar abs. (14 psia) ±100 mbar (±1.45 psi)
• Humidity = 60 % ±15 %
• Reflector: metal plate with diameter ≥ 1 m (40 in)
• No major interference reflections inside the signal beam
Reference accuracy Typical data under reference operating conditions: DIN EN IEC 61298-2 / DIN EN IEC 60770-1;
percentage values in relation to the span.
Accuracy (Sum of non- Measuring distance up to 1.5 m (4.92 ft): max. ±0.02 %
linearity, nonrepeatability ±20 mm (±0.79 in)
and hysteresis) 2)
Measuring distance > 1.5 m (4.92 ft): ±3 mm (±0.12 in) ±0.02 %
3)
Non-repeatability ≤ 1 mm (0.04 in)
20 (0.79)
∆ [mm (in)]
3 (0.12)
0
-3 (-0.12)
-20 (-0.79)
Measured value resolution Dead band according to DIN EN IEC 61298-2 / DIN EN IEC 60770-1:
• Digital: 1 mm
• Analog: 1 µA
Endress+Hauser 23
Micropilot FMR67
Response time The response time can be configured. The following step response times (in accordance with
DIN EN IEC 61298-2 / DIN EN IEC 60770-1) 2) are when damping is switched off:
Influence of ambient The measurements are performed according to DIN EN IEC 61298-3 / DIN EN IEC 60770-1
temperature • Digital (HART, PROFIBUS PA, FOUNDATION Fieldbus): average TK = 3 mm/10 K
• Analog (current output):
– Zero point (4 mA): average TK = 0.02 %/10 K
– Span (20 mA): average TK = 0.05 %/10 K
2) According to DIN EN IEC 61298-2 / DIN EN IEC 60770-1, the step response time is the time that elapses after an abrupt change in the input
signal until the change in the output signal has adopted 90% of the steady-state value for the first time.
24 Endress+Hauser
Micropilot FMR67
Installation
Installation conditions Mounting position
1 2 3
A0016883
• Recommended distance A wall - nozzle outer edge: ~ 1/6 of the container diameter. However, the
device must not under any circumstances be mounted closer than 20 cm (7.87 in) to the container
wall.
If the container wall is not smooth (corrugated iron, welding seams, joints, etc.) it is recommended
to maintain the largest possible distance from the wall. Where necessary use an alignment unit to
avoid interference reflections from the container wall.→ 29
• Not in the center (2) as interference can cause signal loss.
• Not above the filling curtain (3).
• The use of a weather protection cover (1) is recommended to protect the transmitter from direct
sunlight or rain.
• In applications with strong dust emissions, the integrated purge air connection can prevent the
antenna from becoming clogged .
Endress+Hauser 25
Micropilot FMR67
A0031814
Avoid the location of internal fittings (limit switches, temperature sensors, struts etc.) inside the
signal beam. Pay attention to the beam angle .
26 Endress+Hauser
Micropilot FMR67
A0031817
Metal deflection plates installed at an angle to scatter the radar signals help prevent interference
echoes.
Optimization options
• Antenna size
The larger the antenna the smaller the beam angle α,resulting in fewer interference echoes .
• Mapping
Measurement can be optimized by electronically suppressing interference echoes.
• Variable flange seal for FMR67
Variable flange seals of sizes DN80 to DN150 (3" to 6") are available for the FMR67 with Drip-off
antenna 3). They can be used to align the device to the product surface. Maximum angle of
alignment: 8 °.
How to order:
– Order with the device 4)
– Order as an accessory: → 71
• Alignment unit for FMR67
Flanges sized 4" / DN100 and higher are optionally available with an alignment unit 5) They allow
the sensor to be optimally aligned to suit conditions in the container in order to prevent
interference reflections. The maximum angle is ±15 °.
The purpose of sensor alignment is primarily to:
– Prevent interference reflections
– Increase the maximum possible measuring range in conical outlets
Endress+Hauser 27
Micropilot FMR67
Beam angle
α
W= 2 . D . tan_
2
D
α
W
A0031824
The beam angle is defined as the angle α where the energy density of the radar waves reaches half
the value of the maximum energy density (3dB width). Microwaves are also emitted outside the
signal beam and can be reflected off interfering installations.
28 Endress+Hauser
Micropilot FMR67
FMR67
A0032084
A0032083
Beam angle α 6° 4°
Endress+Hauser 29
Micropilot FMR67
Hmax
øD
A0032209
Note the following if the antenna does not project out of the nozzle:
• The end of the nozzle must be smooth and free from burrs. The edge of the nozzle should be
rounded if possible.
• Mapping must be performed.
• Please contact Endress+Hauser for applications with nozzles that are higher than indicated in
the table.
Process connection with UNI flange Material Pressure rating Suitable for
alignment unit 1)
XCA UNI 4" / DN100 / 100A Aluminum max. 14.5lbs / PN1 / 1K • 4" 150lbs
• DN100 PN16
• 10K 100A
XDA UNI 6" / DN150 / 150A Aluminum max. 14.5lbs / PN1 / 1K • 6" 150lbs
• DN150 PN16
• 10K 150A
XEA UNI 8" / DN200 / 200A Aluminum max. 14.5lbs / PN1 / 1K • 8" 150lbs
• DN200 PN16
• 10K 200A
XFA UNI 10" / DN250 / 250A Aluminum max. 14.5lbs / PN1 / 1K • 10" 150lbs
• DN250 PN16
• 10K 250A
30 Endress+Hauser
Micropilot FMR67
A0032097
øD
A0032206
Note the following if the antenna does not project out of the nozzle:
• The end of the nozzle must be smooth and free from burrs. The edge of the nozzle should be
rounded if possible.
• Mapping must be performed.
• Please contact Endress+Hauser for applications with nozzles that are higher than indicated in
the table.
Endress+Hauser 31
Micropilot FMR67
Purge air connection for Purge air adapter for Drip-off antennas
FMR67
Purge air connection 1) Meaning
A without
A0032098
1 1
A0032099
32 Endress+Hauser
Micropilot FMR67
Use
In applications with strong dust emissions, the integrated purge air connection can prevent the
antenna from becoming clogged. Pulse operation is recommended.
Purge air pressure range
• Pulse operation :
Max. 6 bar (87 psi)
• Continuous operation:
200 to 500 mbar (3 to 7.25 psi)
Always use dry purge air.
In general, purging should only be performed to the extent necessary as excess purging can
cause mechanical damage (abrasion).
A0032207
If process temperatures are high, the device should be included in the usual container insulation
system (2) to prevent the electronics from heating as a result of thermal radiation or convection. The
insulation should not be higher than the neck of the device (1).
Endress+Hauser 33
Micropilot FMR67
Environment
Ambient temperature range Measuring device –40 to +80 °C (–40 to +176 °F)
Local display –20 to +70 °C (–4 to +158 °F), the readability of the display may be impaired at
temperatures outside the temperature range.
Ambient temperature limits The following diagrams only consider functional aspects. Additional restrictions may apply for
certified device versions. See the separate Safety Instructions for more information → 78.
In the event of temperature (Tp) at the process connection, the permitted ambient temperature (Ta)
is reduced as indicated in the following diagram (temperature derating) in the table header.
FMR67
Ta
Antenna 1) P1 P2
GA:
Drip-off, PTFE DN50
P3
Seal 2)
A3: Tp
FKM Viton GLT, –40 to 80 °C (–40 to 176 °F) P5 P4
Temperature specifications: °C (°F) A0032024
3)
Housing type P1 P2 P3 P4 P5
Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta
34 Endress+Hauser
Micropilot FMR67
FMR67
Ta
Antenna 1) P1 P2
GP:
PTFE flush mount DN80
P3
Seal 2)
A6: Tp
FKM Viton GLT, –40 to 200 °C (–40 to 392 °F) P5 P4
Temperature specifications: °C (°F) A0032024
Housing type 3) P1 P2 P3 P4 P5
Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta
FMR67
Ta
Antenna 1)
GP: P1 P2 P2+
PTFE flush mount DN80
P3
Seal 2)
A5:
FKM Viton GLT,
Tp
P5 P4
–40 to 150 °C (–40 to 302 °F)
A0032025
Temperature specifications: °C (°F)
Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta Tp Ta
Endress+Hauser 35
Micropilot FMR67
Electromagnetic Electromagnetic compatibility in accordance with all of the relevant requirements outlined in the
compatibility (EMC) EN 61326 series and NAMUR Recommendation EMC (NE 21). For details, please refer to the
Declaration of Conformity 7).
A normal device cable suffices if only the analog signal should be used. Use a shielded cable for
digital communication (HART/ PA/ FF).
Maximum measured error during EMC testing: <0.5 % of the span. By way of derogation, for devices
with a plastic housing and see-through lid (integrated display SD02 or SD03) the measured error can
be up to 2 % of the span in the event of strong electromagnetic radiation in the 1 to 2 GHz frequency
range.
6) This restriction is valid if the following options of the product structure have been selected at the same time: 030 ("Display, Operation") = C
("SD02") or E ("SD03"); 040 ("Housing") = A ("GT19").
7) Available for download at www.de.endress.com.
36 Endress+Hauser
Micropilot FMR67
Process
Process temperature, process
The pressure ranges indicated can be reduced by the choice of process connection. The nominal
pressure
pressure (PN) indicated on the nameplate refers to a reference temperature of 20 °C, and of
100 °F for ASME flanges. Observe pressure-temperature dependency.
Please refer to the following standards for the pressure values permitted at higher
temperatures:
• EN 1092-1: 2001 Tab. 18
In terms of their stability-temperature property, the materials 1.4435 and 1.4404 are
grouped in EN 1092-1 table 18 under 13E0. The chemical composition of the two materials
can be identical.
• ASME B 16.5a – 1998 Tab. 2-2.2 F316
• ASME B 16.5a – 1998 Tab. 2.3.8 N10276
• JIS B 2220
[bar] ([psi]) p
16 (232)
3 (43.5)
0 (0)
-1 (-14.5)
Tp
-40 0 +80 [°C]
(-40) (+32) (+176)
([°F])
A0032186
13 FMR67: Permitted range for process temperature and process pressure, Drip-off antenna, PTFE DN50
1 Process connection: flange PP
2 Process connection: thread, flange 316L
• GGJ:
Thread ISO228 G1-1/2 prel = –1 to 16 bar (–14.5 to 232 psi)
• RGJ: pabs < 17 bar (246 psi) 1)
Thread ANSI MNPT1-1/2
• XJJ:
UNI flange 3"/DN80/80A, 316L
• XKJ:
UNI flange 4"/DN100/100A, 316L –40 to +80 °C (–40 to +176 °F)
• XLJ:
UNI flange 6"/DN150/150A, 316L prel = –1 to 3 bar (–14.5 to 43.5 psi)
• XJG: pabs < 4 bar (58 psi)
UNI flange 3"/DN80/80A, PP
• XKG:
UNI flange 4"/DN100/100A, PP
• XLG:
UNI flange 6"/DN150/150A, PP
1) The pressure range may be further restricted in the event of a CRN approval
Endress+Hauser 37
Micropilot FMR67
[bar] ([psi]) p
1 2
16 (232)
0 (0)
-1 (-14.5) Tp
-40 0 +150 +200 [°C]
(-40) (+32) (+302) (+392) ([°F])
A0032187
14 FMR67: Permitted range for process temperature and process pressure, antenna, PTFE DN80, standard
flange 316L
1 Feature 90, seal: A5, FKM Viton GLT
2 Feature 90, seal: A6, FKM Viton GLT
1) The pressure range may be further restricted in the event of a CRN approval
[bar] ([psi]) p
1 2
1 (14.5)
0 (0)
-1 (-14.5) Tp
-40 0 +150 +200 [°C]
(-40) (+32) (+302) (+392) ([°F])
A0032199
15 FMR67: Permitted range for process temperature and process pressure, antenna, PTFE DN80, UNI flange
316L
1 Feature 90, seal: A5, FKM Viton GLT
2 Feature 90, seal: A6, FKM Viton GLT
38 Endress+Hauser
Micropilot FMR67
1) The pressure range may be further restricted in the event of a CRN approval
FMR67, flush mount antenna, PTFE DN80, UNI flange, ALU, adjustable
[bar] ([psi]) p
1 2
1 (14.5)
0 (0)
-1 (-14.5) Tp
-40 0 +150 +200 [°C]
(-40) (+32) (+302) (+392) ([°F])
A0032199
16 FMR67: Permitted range for process temperature and process pressure, antenna, PTFE DN80, UNI flange,
ALU, adjustable
1 Feature 90, seal: A5, FKM Viton GLT
2 Feature 90, seal: A6, FKM Viton GLT
1) The pressure range may be further restricted in the event of a CRN approval
Endress+Hauser 39
Micropilot FMR67
Mechanical construction
Dimensions Dimensions of the electronics housing
R100 98 (3.86)*
78 (3.07) 90 (3.54)
07)
(4.
141.9 (5.59)
3.5
ø108.5 (4.27)
144 (5.67)
115.25 (4.54)
ø10
A0011666
R100
99.5 (3.92)*
78 (3.07) 90 (3.54)
)
.17
6 (4
144 (5.67)
ø10
ø106 (4.17)
134.5 (5.3)
A0011346
R100 97 (3.82)*
78 (3.07) 90 (3.54)
7)
4.0
(
141.5 (5.57)
3.5
ø104.5 (4.11)
144 (5.67)
117.1 (4.61)
ø108.5 (4.27)
ø10
A0020751
40 Endress+Hauser
Micropilot FMR67
A B
ø60 (2.36)
R R
107 (4.21)
127 (5.00)
22 (0.87)
20 (0.79)
205 (8.07)
78 (3.07)
ø42.5 (1.67) ø42.5 (1.67)
øD
A0031560
20 Dimensions: mm (in)
A Process connection: G1-1/2" or MNPT1-1/2" thread
B Process connection: UNI flange 3"/DN80/80A to 6"/DN150/150A
R Bottom edge of housing
• XLG:
• 6" 150lbs
UNI flange 6"/DN150/150A, PP
• DN150 PN16 285 mm (11.22 in)
• XLJ:
• 10K 150A
UNI flange 6"/DN150/150A, 316L
Endress+Hauser 41
Micropilot FMR67
ø100 (3.94)
ø60 (2.36)
138 (5.43)
20 (0.79)
47 (1.85)
ø42.5 (1.67)
øD
A0032154
21 Dimensions: mm (in)
R Bottom edge of housing
• 3" 150lbs
XJG:
• DN80 PN16 200 mm (7.87 in)
UNI flange 3"/DN80/80A, PP
• 10K 80A
• 4" 150lbs
XKG:
• DN100 PN16 228.6 mm (9 in)
UNI flange 4"/DN100/100A, PP
• 10K 100A
• 6" 150lbs
XLG:
• DN150 PN16 285 mm (11.22 in)
UNI flange 6"/DN150/150A, PP
• 10K 150A
42 Endress+Hauser
Micropilot FMR67
A B
ø80 (3.15)
ø60 (2.36)
162 (6.38)
233 (9.17)
25.5 (1.00)
H
ø70 (2.76)
øD
A0032172
22 Dimensions: mm (in)
A Seal: FKM Viton GLT, -40 to 150°C/-40 to 302°F
B Seal: FKM Viton GLT, -40 to 200°C/-40 to 392°F
R Bottom edge of housing
AGJ:
ASME B16.5 190.5 mm 23.9 mm
NPS 3" Cl.150 RF, 316/316L CL.150
NPS 3" Cl.150 RF (7.5 in) (0.94 in)
316/316L
AHJ:
ASME B16.5 228.6 mm 23.9 mm
NPS 4" Cl.150 RF, 316/316L CL.150
NPS 4" Cl.150 RF (9 in) (0.94 in)
316/316L
Endress+Hauser 43
Micropilot FMR67
A B
ø86 (3.39)
ø60 (2.36)
233 (9.17)
174 (6.85)
13.5 (0.53)
8 (0.31)
ø70 (2.76)
øD
A0032180
23 Dimensions: mm (in)
A Seal: FKM Viton GLT, -40 to 150°C/-40 to 302°F
B Seal: FKM Viton GLT, -40 to 200°C/-40 to 392°F
R Bottom edge of housing
• 8" 150lbs
X3J:
• DN200 PN16 pabs < 2 bar (29 psi) 340 mm (13.39 in)
UNI flange DN200/8"/200A, 316L
• 10K 200A
• 10" 150lbs
X5J:
• DN250 PN16 pabs < 2 bar (29 psi) 405 mm (15.94 in)
UNI flange DN250/10"/250A, 316L
• 10K 250A
44 Endress+Hauser
Micropilot FMR67
FMR67 DN80 antenna, purge air connection, UNI flange with alignment device
A B
ø60 (2.36)
163 (6.42)
232 (9.13)
24 (0.94)
12 (0.47)
ø70 (2.76)
ø95 (3.74)
øD
A0032173
24 Dimensions: mm (in)
A Seal: FKM Viton GLT, -40 to 150°C/-40 to 302°F
B Seal: FKM Viton GLT, -40 to 200°C/-40 to 392°F
R Bottom edge of housing
Endress+Hauser 45
Micropilot FMR67
4 × 90°
2
4×
4×
90
°
90
0°
1
4×9
°
ø19 (0.75)
A A A ø12 (0.47) A
4 ø26 (1.02)
3
° 4
60
°
×
60
×
90
6×
6
12
°
× 30 °
ø26 (1.02)
A A
A A
ø26 (1.02)
ø294.5 (11.6) ø358 (14.1)
ø340 (13.4) ø405 (15.9)
10 (0.39)
A-A
A0032136
• 4" 150lbs
XCA:
1: • DN100 PN16 Aluminum
alignment device, UNI 4"/DN100/100A, max 14.5lbs/PN1/1K
• 10K 100A
• 6" 150lbs
XDA:
2: • DN150 PN16 Aluminum
alignment device, UNI 6"/DN150/150A, max 14.5lbs/PN1/1K
• 10K 150A
• 8" 150lbs
XEA:
3: • DN200 PN16 Aluminum
alignment device, UNI 8"/DN200/200A, max 14.5lbs/PN1/1K
• 10K 200A
• 10" 150lbs
XFA:
4: • DN250 PN16 Aluminum
alignment device, UNI 10"/DN250/250A, max 14.5lbs/PN1/1K
• 10K 250A
The number of bolts is reduced in some cases. To match different standards the bores are
enlarged. Therefore the bolts should be aligned centrally to the counter flange before
tightening.
46 Endress+Hauser
Micropilot FMR67
Weight Housing
Part Weight
Endress+Hauser 47
Micropilot FMR67
5.2
6
5.1
7
4 3 9 8
A0013788
5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland: 316L (1.4404) or nickel-plated brass
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)
5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug: 316L (1.4404)
the device version) • Cable gland: 316L (1.4404) or nickel-plated brass
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
6 Dummy plug or M12 socket (depending on the • Dummy plug: 316L (1.4404)
device version) • M12 socket: 316L (1.4404)
1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.
48 Endress+Hauser
Micropilot FMR67
5.2
6
5.1
7
4 3 9 8
A0013788
1 Housing PBT
5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)
5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug, depending on the device version:
the device version) – PE
– PBT-GF
– Nickel-plated steel
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
6 Dummy plug or M12 socket (depending on the • Dummy plug: Nickel-plated brass (CuZn)
device version) • M12 socket: Nickel-plated GD-Zn
1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.
Endress+Hauser 49
Micropilot FMR67
5.2
6
5.1
7
4 3 9 8
A0013788
2.1 Cover of the electronics compartment; RAL 7035 • Cover: AlSi10Mg(<0,1% Cu)
(gray) • Window: Glass
• Cover seal: NBR
• Seal of the window: NBR
• Thread-coating: Graphite-based lubricant varnish
2.2 Cover of the terminal compartment; RAL 7035 • Cover: AlSi10Mg(<0,1% Cu)
(gray) • Cover seal: NBR
• Thread-coating: Graphite-based lubricant varnish
5.1 Dummy plug, cable gland, adapter or plug • Dummy plug, depending on the device version:
(depending on the device version) – PE
– PBT-GF
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
• M12 plug: Nickel-plated brass 1)
• 7/8" plug: 316 (1.4401) 2)
5.2 Dummy plug, cable gland or adapter (depending on • Dummy plug, depending on the device version:
the device version) – PE
– PBT-GF
– Nickel-plated steel
• Cable gland, depending on the device version:
– Nickel-plated brass (CuZn)
– PA
• Adapter: 316L (1.4404/1.4435)
• Seal: EPDM
6 Dummy plug or M12 socket (depending on the • Dummy plug : Nickel-plated brass (CuZn)
device version) • M12 socket: Nickel-plated GD-Zn
50 Endress+Hauser
Micropilot FMR67
1) For the version with M12 plug the sealing material is Viton.
2) For the version with 7/8" plug, the sealing material is NBR.
3 3
5 5
6 6
2 2
1
1
A0031816
1 Antenna PTFE
C
4
5
2 6
7
1
A0032126
Endress+Hauser 51
Micropilot FMR67
1 Antenna PTFE
52 Endress+Hauser
Micropilot FMR67
Materials: Weather
protection cover 1
2
3
7 4
5
6
A0015473
No Part: Material
6 Ground terminal
• Screw: A4
• Spring washer: A4
• Clamp: 316L (1.4404)
• Holder: 316L (1.4404)
7 • Washer: A4
• Cheese head screw: A4-70
Endress+Hauser 53
Micropilot FMR67
Operability
Operating concept Operator-oriented menu structure for user-specific tasks
• Commissioning
• Operation
• Diagnostics
• Expert level
Operating languages
• English
• Deutsch
• Français
• Español
• Italiano
• Nederlands
• Portuguesa
• Polski
• русский язык (Russian)
• Svenska
• Türkçe
• 中文 (Chinese)
• 日本語 (Japanese)
• 한국어 (Korean)
• Bahasa Indonesia
• tiếng Việt (Vietnamese)
• čeština (Czech)
Feature 500 of the product structure determines which of these languages is preset on delivery.
A0032219 A0032221
54 Endress+Hauser
Micropilot FMR67
Format for displaying measured variables and status variables can be individually configured
Permitted ambient temperature for the display: –20 to +70 °C (–4 to +158 °F)
The readability of the display may be impaired at temperatures outside the temperature
range.
Operating local operation with 3 push buttons (, , external operation via touch control; 3 optical
elements ) keys: , ,
A0032215
2 3 6 8
1 4 5 7
A0028746
Endress+Hauser 55
Micropilot FMR67
1
A0032466
1 Service interface (CDI) of the measuring device (= Endress+Hauser Common Data Interface)
2 Commubox FXA291
3 Computer with "FieldCare" operating tool
56 Endress+Hauser
Micropilot FMR67
1 1 2
ENDRESS+HAUSER ENDRESS+HAUSER
RN 221N RN 221N
FXN 520
20...45 VDC
-
.
A0011278
The number of instruments which can be connected in mutidrop mode can be calculated by the
"FieldNetCalc" program. A description of this program can be found in Technical Information TI
400F (Multidrop Conncector FXN520). The program is available form your Endress+Hauser
sales organisation or in the internet at: www.de.endress.com/Download (text search =
"Fieldnetcalc").
Endress+Hauser 57
Micropilot FMR67
RoHS The measuring system complies with the substance restrictions of the Restriction on Hazardous
Substances Directive 2011/65/EU (RoHS 2).
RCM-Tick marking The supplied product or measuring system meets the ACMA (Australian Communications and Media
Authority) requirements for network integrity, interoperability, performance characteristics as well
as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic
compatibility are met. The products are labelled with the RCM- Tick marking on the name plate.
A0029561
Ex approval • ATEX
• IEC Ex
• CSA
• FM
• NEPSI
• KC
• INMETRO
• TIIS 8)
• EAC Ex
Additional safety instructions must be followed for use in hazardous areas. Please refer to the
separate "Safety Instructions" (XA) document included in the delivery. Reference to the applicable XA
can be found on the nameplate.
For details on the available certificates and associated XAs: → 78
Dual seal according to The devices have been designed according to ANSI/ISA 12.27.01 as dual seal devices, allowing the
ANSI/ISA 12.27.01 user to waive the use and save the cost of installing external secondary process seals in the conduit
as required by the process sealing sections of ANSI/NFPA 70 (NEC) and CSA 22.1 (CEC) These
instruments comply with the North-American installation practice and provide a very safe and cost-
saving installation for pressurized applications with hazardous fluids.
Further information can be found in the Safety Instructions (XA) of the relevant devices.
Functional safety Use for level monitoring (MIN, MAX, range) up to SIL 3 (homogeneous or diverse redundancy),
independently evaluated by TÜV Rheinland in accordance with IEC 61508, refer to the "Functional
Safety Manual" for information.
Pressure equipment with Pressure instruments with a flange and threaded boss that do not have a pressurized housing do not
allowable pressure fall within the scope of the Pressure Equipment Directive, irrespective of the maximum allowable
≤ 200 bar (2 900 psi) pressure.
Reasons:
According to Article 2, point 5 of EU Directive 2014/68/EU, pressure accessories are defined as
"devices with an operational function and having pressure-bearing housings".
If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber
of its own), there is no pressure accessory present within the meaning of the Directive.
8) in preparation
58 Endress+Hauser
Micropilot FMR67
Note:
A partial examination shall be performed for pressure instruments that are part of safety equipment
for the protection of a pipe or vessel from exceeding allowable limits (equipment with safety
function in accordance with Pressure Equipment Directive 2014/68/EU, Article 2, point 4).
FMR67
Radio standard The devices comply with the Level Probing Radar (LPR) radio standard EN 302729-1/2. The devices
EN 302729-1/2 are approved for unrestricted use inside and outside closed containers in countries of the EU and the
EFTA . that have already implemented this standard.
The following countries are those that have currently implemented the directive:
Belgium, Bulgaria, Germany, Denmark, Estonia, France, Greece, UK, Ireland, Iceland, Italy,
Liechtenstein, Lithuania, Latvia, Malta, The Netherlands, Norway, Austria, Poland, Portugal,
Romania, Sweden, Switzerland, Slovakia, Spain, Czech Republic and Cyprus.
Implementation is still underway in all of the countries not listed.
Please note the following for operation of the devices outside of closed vessels:
1. Installation must be carried out by properly trained, expert staff.
2. The device antenna must be installed in a fixed location pointing vertically downwards.
3. The installation site must be located at a distance of 4 km from the astronomy stations listed
below or otherwise approval must be provided by the relevant authority. If the device is
installed at a distance of 4 to 40 km from one of the listed stations, it must not be installed at a
height of more than 15 m (49 ft) above the ground.
Astronomy stations
Country Name of the station Latitude Longitude
Endress+Hauser 59
Micropilot FMR67
Radio standard The devices comply with the Tanks Level Probing Radar (TLPR) radio standard EN 302372-1/2 and
EN 302372-1/2 are approved for use in closed containers. For installation, points a to f in Annex B of EN 302372-1
must be taken into consideration.
FCC / Industry Canada This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Canada CNR-Gen Section 7.1.3
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) This device may not interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts
de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
[Any] changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
The devices are compliant with the FCC Code of Federal Regulations, CFR 47, Part 15, Sections
15.205, 15.207, 15.209.
In addition, the devices are compliant with Section 15.256 . For these LPR (Level Probe Radar)
applications the devices must be professionally installed in a downward operating position. In
addition, the devices are not allowed to be mounted in a zone of 4 km around RAS stations and
within a radius of 40 km around RAS stations the maxium operation height of devices is 15 m (49 ft)
above ground.
60 Endress+Hauser
Micropilot FMR67
Test reports, declarations and inspection certificates are available in electronic format in the
W@M Device Viewer:
Enter the serial number from nameplate (www.endress.com/deviceviewer)
This concerns the options for the following order codes:
• 550 "Calibration"
• 580 "Test, certificate"
Hard-copy product Hard-copy versions of the test reports, declarations and inspection certificates can also be order via
documentation order code 570 "Service", option I7 "Hard-copy product documentation". The documents are then
supplied with the product.
Endress+Hauser 61
Micropilot FMR67
62 Endress+Hauser
Micropilot FMR67
Ordering information
Ordering information Detailed ordering information is available from the following sources:
• In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate"
-> Select your country -> Click "Products" -> Select the product using the filters and search field ->
Open product page -> The "Configure" button to the right of the product image opens the Product
Configurator.
• From your Endress+Hauser Sales Center: www.addresses.endress.com
Product Configurator - the tool for individual product configuration
• Up-to-the-minute configuration data
• Depending on the device: Direct input of measuring point-specific information such as
measuring range or operating language
• Automatic verification of exclusion criteria
• Automatic creation of the order code and its breakdown in PDF or Excel output format
• Ability to order directly in the Endress+Hauser Online Shop
Endress+Hauser 63
Micropilot FMR67
3-point linearity protocol The following points must be considered if option F3 (3-point linearity protocol) was selected in
feature 550 ("Calibration").
The 3 points of the linearity protocol are defined as follows:
A
1
500 (19.7)
6000 (236)
2
A0032642
2nd measuring point In the middle between the 1st and 3rd measuring point
3rd measuring point 6 000 mm (236 in) below the reference point R
64 Endress+Hauser
Micropilot FMR67
5-point linearity protocol The following points must be considered if option F4 (5-point linearity protocol) was selected in
feature 550 ("Calibration").
The 5 points of the linearity protocol are evenly distributed over the measuring range (0% - 100%).
Empty calibration (E) and Full calibration (F) must be specified in order to define the measuring
range 9).
The following restrictions must be considered when selecting E and F:
A
E
F
A0032643
Minimum distance between reference point R and 100% mark Minimum span Maximum value for "Empty calibration"
1)
A ≥ length of antenna + 600 mm (24 in) F ≥400 mm (16 in) E ≤20 m (66 ft)
The selected values for Empty calibration and Full calibration are only used to create the
linearity protocol. Afterwards, the values are reset to the default values specific for the
antenna. If values other than the default values are required, they must be ordered as a
customized parameterization → 66.
9) If (E) and (F) are not specified, antenna-dependent default values will be used instead.
Endress+Hauser 65
Micropilot FMR67
Customer-specific If the option IJ: "Customized parameterization HART", IK "Customized parameterization PA" or IL
configuration "Customized parameterization FF" has been selected in feature 570 "Service", presettings that differ
from the default settings can be selected for the following parameters:
Services The following services can be selected via the product structure in the Product Configurator 10):
• PWIS-free (PWIS = paint-wetting impairment substances)
• Customized parameterization HART → 66
• Customized parameterization PA → 66
• Customized parameterization FF → 66
• W/o tooling DVD (FieldCare)
• Hard-copy product documentation
66 Endress+Hauser
Micropilot FMR67
Application Packages
Heartbeat Diagnostics Availability
Available in all device versions.
Function
• Continuous self-monitoring of the device.
• Diagnostic messages output to
– the local display.
– an asset management system (e.g. FieldCare/DeviceCare).
– an automation system (e.g. PLC).
Advantages
• Device condition information is available immediately and processed in time.
• The status signals are classified in accordance with VDI/VDE 2650 and NAMUR recommendation
NE 107 and contain information about the cause of the error and remedial action.
Detailed description
See Operating Instructions of the device ((Verweisziel existiert nicht, aber @y.link.required='true'));
chapter "Diagnostics and trouble shooting"
Endress+Hauser 67
Micropilot FMR67
Advantages
• No onsite presence is required to use the function.
• The DTM 11) triggers verification in the device and interprets the results. No specific knowledge is
required on the part of the user.
• The verification report can be used to prove quality measures to a third party.
• Heartbeat Verification can replace other maintenance tasks (e.g. periodic check) or extend the
test intervals.
• The Heartbeat Verification module contains a wizard for the proof test which must be performed
at appropriate intervals for the following applications:
– SIL (IEC61508/IEC61511)
– WHG (German Water Resources Act)
• To perform a proof test, the device must be locked (SIL/WHG locking).
• The wizard can be used via FieldCare, DeviceCare or a DTM-based process control system.
In the case of SIL-locked and WHG-locked devices, it is not possible to perform verification
without additional measures (e.g. by-passing of the output current) because the output current
must be simulated (Increased safety mode) or the level must be approached manually (Expert
mode) during subsequent re-locking (SIL/WHG locking).
Detailed description
SD01870F
11) DTM: Device Type Manager; controls device operation via DeviceCare, FieldCare or a DTM-based process control system.
12) Only relevant for devices with SIL or WHG approval: order code 590 ("Additional approval"), option LA ("SIL") or LC ("WHG").
68 Endress+Hauser
Micropilot FMR67
Function
• In addition to the verification parameters, the corresponding parameter values are also logged.
• Existing measured variables, such as the echo amplitude, are used in the Foam detection and
Build-up detection wizards.
The Foam detection and Build-up detection wizards cannot be used together.
Advantages
• Early detection of changes (trends) to ensure plant availability and product quality.
• Use of information for the proactive planning of measures (e.g. cleaning/maintenance).
• Identification of undesirable process conditions as the basis to optimizing the facility and the
processes.
• Automated control of measures to remove foam or buildup.
Detailed description
SD01870F
Endress+Hauser 69
Micropilot FMR67
Accessories
Device-specific accessories Weather protection cover
Accessory Description
222 (8.74)
A0015466
4)
65°
35°
(6.1
156
A0015472
The weather protection cover can be ordered together with the device (product structure, feature 620 "Accessory
Enclosed", option PB "Weather Protection Cover").
Alternatively, it can be separately ordered as an accessory; order code 71162242.
70 Endress+Hauser
Micropilot FMR67
Accessories Description
Adjustable
flange seal
4° ød
øD
1
2
h
±8°
hmax
hmin
A0032292
The material properties and process conditions of the adjustable flange seal must be compatible with the properties
(temperature, pressure, resistance) of the process.
The adjustable flange seal can also be ordered directly with the device (product structure: feature 620 "Accessories
enclosed", options PL, PM, PN, PO, PQ, PR).
Recommended screw length 100 mm (3.9 in) 100 mm (3.9 in) 110 mm (4.3 in)
Material EPDM
Endress+Hauser 71
Micropilot FMR67
Accessories Description
Compatible with • ASME 3" 150lbs ASME 4" 150lbs ASME 6" 150lbs
• JIS 80A 10K
Recommended screw length 100 mm (3.9 in) 100 mm (3.9 in) 110 mm (4.3 in)
Material EPDM
72 Endress+Hauser
Micropilot FMR67
Accessories Description
Mounting bracket
adjustable
260 (10.2)
99.5 (3.9)
9(0.4)
ø9(0.4)
65 (2.6)
122 (4.8)
48(1.9)
12(0.5)
35(1.4) 100 (3.9) 16 (0.6)
A0032295
•• There is no conductive connection between the mounting bracket and the transmitter housing.
Risk of electrostatic charge.
• Integrate the mounting bracket in the local potential equalization system.
• Only to be fastened at stable materials (e.g. metal, brick, concrete) using suitable fastening material (to be
supplied by customer).
Endress+Hauser 73
Micropilot FMR67
Accessories Description
2.
1.
4.
3.
A0019128
• Material:
– Plastic PBT
– 316L/1.4404
• Degree of protection: IP68 / NEMA 6P and IP66 / NEMA 4x
• Suitable for display modules:
– SD02 (push buttons)
– SD03 (touch control)
• Connecting cable:
– Cable supplied with device up to 30 m (98 ft)
– Standard cable supplied by customer up to 60 m (196 ft)
• Ambient temperature range: –40 to 80 °C (–40 to 176 °F)
• IfL ortheM).remote display should be used, order the device version "Prepared for display FHX50" (feature 030, version
For the FHX50, you must select option A: "Prepared for display FHX50" under feature 050 "Measuring
device version".
• If the device version "Prepared for display FHX50" was not originally ordered and a FHX50 display is to be
retrofitted, you must select version B "Not prepared for display FHX50" under feature 050: "Measuring device
version" when ordering the FHX50. In this case, a retrofit kit for the device is supplied with the FHX50. The kit
can be used to prepare the device so that the FHX50 can be used.
Use of the FHX50 may be restricted for transmitters with an approval. A device can only be retrofitted with the
FHX50 if the option L or M ("Prepared for FHX50") is listed under Basic specifications, item 4 "Display, operation" in
the Safety Instructions (XA) for the device.
Also pay attention to the Safety Instructions (XA) of the FHX50.
74 Endress+Hauser
Micropilot FMR67
Overvoltage protection
Accessory Description
A0021734
Technical data
• Resistance per channel: 2 * 0.5 Ωmax
• Threshold DC voltage: 400 to 700 V
• Threshold impulse voltage: < 800 V
• Capacitance at 1 MHz: < 1.5 pF
• Nominal arrest impulse voltage (8/20 μs): 10 kA
• Suited for wire cross-sections: 0.2 to 2.5 mm2 (24 to 14 AWG)
Endress+Hauser 75
Micropilot FMR67
Accessory Description
Commubox FXA291 Connects Endress+Hauser field devices with CDI interface (= Endress+Hauser
Common Data Interface) to the USB interface of a computer.
Order code: 51516983
Accessory Description
HART Loop Converter Evaluates the dynamic HART variables and converts them to analog current signals
HMX50 or limit values.
Order code: 71063562
Accessory Description
Accessory Description
Fieldgate FXA320 Gateway for remote monitoring of connected 4-20mA measuring devices via web
browser.
Accessory Description
Fieldgate FXA520 Gateway for remote diagnosis and parametrization of connected HART measuring
devices via web browser.
Zubehör Beschreibung
Fieldgate FXA42 Programmable Ethernet, 2G/3G and WLAN gateway for data transmission
between digital and analog measuring devices and inventory management
software
76 Endress+Hauser
Micropilot FMR67
Accessory Description
Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
fieldbus devices in the non-Ex area.
Accessory Description
Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance. It
enables efficient device configuration and diagnostics for HART and FOUNDATION
fieldbus devices in the non-Ex area and the Ex area.
Graphic Data Manager The graphic data manager Memograph M provides information on all the relevant
Memograph M process variables. Measured values are recorded correctly, limit values are
monitored and measuring points analyzed. The data are stored in the 256 MB
internal memory and also on an SD card or USB stick.
RN221N Active barrier with power supply for safe separation of 4 to 20 mA current circuits.
Provides bi-directional HART transmission.
RNS221 Transmitter supply for 2-wire sensors or transmitters exclusively for non-Ex areas.
Provides bi-directional communication using the HART communication sockets.
Endress+Hauser 77
Micropilot FMR67
Supplementary documentation
For an overview of the scope of the associated Technical Documentation, refer to the following:
• The W@M Device Viewer: enter the serial number from the nameplate
(www.endress.com/deviceviewer)
• The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the
2-D matrix code (QR code) on the nameplate.
The following document types are available:
In the Download Area of the Endress+Hauser Internet site: www.endress.com → Downloads
Description of device *
parameters
Description of device *
parameters
1) In preparation
Safety Instructions (XA) Depending on the approval, the following Safety Instructions (XA) are supplied with the device. They
are an integral part of the Operating Instructions.
BC ATEX II 1/2G Ex ia/db [ia Ga] IIC T6 Ga/Gb XA01552F XA01552F XA01552F XA01560F XA01552F
BD ATEX II 1/2/3G Ex ia/ic [ia Ga] IIC T6 Ga/Gb/Gc XA01550F XA01550F XA01550F XA01558F -
BF ATEX II 1/2D Ex ta/tb IIIC T85°C Da/Db XA01554F XA01554F XA01554F XA01562F XA01554F
BL ATEX II 1/2/3G Ex ia/ec [ia Ga] IIC T6 Ga/Gb/Gc XA01550F XA01550F XA01550F XA01558F XA01550F
B2 ATEX II 1/2G Ex ia IIC T6 Ga/Gb, 1/2D Ex ia IIIC T85°C Da/Db XA01555F XA01555F XA01555F XA01563F -
B3 ATEX II 1/2G Ex ia/db [ia Ga] IIC T6, Ga/Gb 1/2D Ex ta/tb IIIC T85°C XA01556F XA01556F XA01556F XA01564F XA01556F
Da/Db
78 Endress+Hauser
Micropilot FMR67
GA EAC Ex ia IIC T6 Ga * 8) * 8) * 8) * 8) -
8) 8) 8) 8)
GB EAC Ex ia IIC T6 Ga/Gb * * * * -
8) 8) 8) 8)
GC EAC Ex ia/db [ia Ga] IIC T6 Ga/Gb * * * * * 8)
GE EAC Ex ta IIIC Da * 8) * 8) * 8) * 8) * 8)
IC IEC Ex ia/db [ia Ga] IIC T6 Ga/Gb XA01552F XA01552F XA01552F XA01560F XA01552F
ID IEC Ex ia/ic [ia Ga] IIC T6 Ga/Gb/Gc XA01550F XA01550F XA01550F XA01558F -
IF IEC Ex ta/tb IIIC T85°oC Da/Db XA01554F XA01554F XA01554F XA01562F XA01554F
IL IEC Ex ia/ec [ia Ga] IIC T6 Ga/Gb/Gc XA01550F XA01550F XA01550F XA01558F -
I2 IEC Ex ia IIC T6 Ga/Gb, Ex ia IIIC T85°C Da/Db XA01555F XA01555F XA01555F XA01563F -
I3 IEC Ex ia/db [ia Ga] IIC T6 Ga/Gb, Ex ta/tb IIIC T85°C Da/Db XA01556F XA01556F XA01556F XA01564F XA01556F
KA KC Ex ia IIC T6 Ga * 8) * 8) * 8) * 8) -
KB KC Ex ia IIC T6 Ga/Gb * 8) * 8) * 8) * 8) -
MA INMETRO Ex ia IIC T6 Ga * 8) * 8) * 8) * 8) -
8) 8) 8) 8)
ME INMETRO Ex ta IIIC Da * * * * * 8)
MH INMETRO Ex ic IIC T6 Gc * 8) * 8) * 8) * 8) -
8) 8) 8) 8)
NA NEPSI Ex ia IIC T6 Ga * * * * -
8) 8) 8) 8)
NB NEPSI Ex ia IIC T6 Ga/Gb * * * * -
8) 8) 8) 8)
NC NEPSI Ex ia/db [ia Ga] IIC T6 Ga/Gb * * * * * 8)
NG NEPSI Ex ec IIC T6 Gc * 8) * 8) * 8) * 8) * 8)
NH NEPSI Ex ic IIC T6 Gc * 8) * 8) * 8) * 8) -
8) 8) 8) 8)
N2 NEPSI Ex ia IIC T6 Ga/Gb, Ex iaD 20/21 T85...90°C * * * * -
Endress+Hauser 79
Micropilot FMR67
The nameplate indicates the Safety Instructions (XA) that are relevant to the device.
If the device is prepared for the remote display FHX50 (product structure: feature 030: Display,
Operation", option L or M), the Ex marking of some certificates changes according to the following
table 13):
13) The marking of certificates not mentioned in this table are not affected by the FHX50.
*71355015* 71355015
www.addresses.endress.com