Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 2

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Drilled Cast-in-place Pile Design Based on ACI 318-19

DESIGN CRITERIA
1. ASSUME FIX HEAD CONDITION IF Ldh & Lhk COMPLY WITH THE TENSION DEVELOPMENT. OTHERWISE PINNED AT TOP.

2. FROM PILE CAP BALANCED LOADS & REACTIONS, DETERMINE MAX SECTION FORCES OF SINGLE PILE, Pu, Mu, & Vu.

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH fc' = 4.5 ksi
VERT. REBAR YIELD STRESS fy = 60 ksi
PILE DIAMETER D = 24 in
PILE LENGTH L = 35 ft
FACTORED AXIAL LOAD Pu = 100 k
FACTORED MOMENT LOAD Mu = 200 ft-k
FACTORED SHEAR LOAD Vu = 20 k
PILE VERT. REINF. 8 # 7
SEISMIC DESIGN (ACI 18.13.4) ? Yes
LATERAL REINF. OPTION (0=Spirals, 1=Ties) 1 Ties
LATERAL REINFORCEMENT # 4 @ 6 in o.c.
(spacing 3.0 in o.c. at top end of 10.0 ft.)
(2018 IBC 1810.3.9 & ACI 18.13.4)

( Ldh = 11 in & Lhk = 16 in )

THE DESIGN IS INADEQUATE.

ANALYSIS
CHECK PILE LIMITATIONS
fc ' = 4.5 ksi > 4 ksi [Satisfactory] (2018 IBC Table 1808.8.1)
D= 24 in > MAX( L / 30 , 12 in) [Satisfactory] (2018 IBC 1810.3.5.2)

CHECK FLEXURAL & AXIAL CAPACITY


     2
  f C'  2   c     c   , for 0   c   o  s E s , for  s   ty
e
 fC    o    o   , f S
 '
 f y , for  s   ty
  e f C , for  c   o

 
2  e f 'C  fy  ty , for compression controlled
o  ,  ty  , t  
Ec Es  ty  0.003 , for tension controlled
'
E c  57 f C , E s  29000ksi ,  e  0.85 ,  cu  0.003

f Pmax =F f [ 0.85 fc' (Ag - Ast) + fy Ast] = 1040 kips., (at max axial load, ACI 318-19 22.4.2)
where F = 0.8 , ACI 318-19 22.4.2
f = 0.65 (ACI 318-19 21.2) > Pu [Satisfactory]
Ag = 452 in2. Ast = 4.80 in2.
(cont'd)

Note:
1. Between compression & tension controlled is
Transition, which the f should be by linear
f Pn (k) interpolation. (ACI 318-19 Tab. 21.2.2 & Fig. R10.4.2.1)
500 2. ACI 318-19 changed f (Fig.R21.2.2b) and keeps
be (22.2.2.4.1) and ecu (Fig. R21.2.2a) the same.
But AISC 360/341-16 has different f (0.9 only) and
be (1.0 or 0.7).
0
0 50 100 150 200 250 300 350

f Mn (ft-k)
Solid Black Line - Tension Controlled
Solid Red Line - Transition
Dash Line - Compression Controlled

f Mn = 238 ft-kips @ Pu = 100 kips > Mu [Satisfactory]


r max = 0.06 (ACI 318-19 18.7.4.1) rprovd = 0.011
rmin = 0.01 (ACI 318-19 18.7.4.1& 10.6.1.1) [Satisfactory]

CHECK SHEAR CAPACITY


f Vn = f (Vs + Vc) = 92 kips, (ACI 318-19 22.5)
> Vu [Satisfactory]
where f = 0.75 (ACI 318-19 21.2)
A0 = 316 in2. Av = 0.40 in2. fy = 60 ksi
Vc = 2 (fc')0.5A0 = 42.4 kips, (ACI 318-19 22.5)
Vs = MIN (d fy Av / s , 8 (fc')0.5A0) = 80.3 kips, (ACI 318-19 22.5.1)
smax = 10.5 (2018 IBC 1810.3.9.4.2) sprovd = 6 in
smin = 1 [Satisfactory]
rs = 0.12 fc' / fyt = 0.009 > rs,provd = 0.008 [Unsatisfactory] (ACI 318-19 18.13.4.3 & 18.7.5.1)

DETERMINE FIX HEAD CONDITION


  
requird  e d b f y
L dh  MAX  , 8d b , 6 in  
  provided 55 f '  13 db =
 c  11 in
(ACI 318-19 25.4.3)

Lhk = 16 in, (ACI 318-19 25.4)

where db = 0.875 in
r required / r provided = 1 ( A s,reqd / A s,provd , ACI 318-19 25.4.10.2)
ye = 1.0 (1.2 for epoxy-coated, ACI 318-19 25.4.2.4)
l = 1.0 (normal weight)
h = 0.7 (#11 or smaller, cover > 2.5" & side >2.0",
ACI 318-19 25.4.3.2)

You might also like