2 SP2 Issues Resolved


10.02.0002.17001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


1. 1-7I8NHA G/Technology Can't display secondary label Secondary data publish with Microstation V8 dgn file is published to a ddc,
Administrator data however the ddc contains 0 rows.

Resolution: Added support for Unicode text so that Text and Text Nodes can
now be published.
2. 1-AYI798 G/Technology If 2 users are editing/posting If 2 users are graphically editing the same feature and one of users posts their
Designer the same feature, in some job, the second user will not see the changes made by user 1. If the 2nd user
cases Merge Features gives an then attempts to do a Merge Feature using a particular workflow, an error is
error. displayed and the user is not notified that they must refresh database edits.

Resolution: The error "The database geometry is not the same as the DDC
geometry. So refresh." is now being displayed.
3. 1-95FX1W G/Technology Pass Back failing when We have found a workflow where Pass Back fails when components only exist
1-EDSYGP Designer components only exist in in a detail window. For example, if you have a gas site feature that includes
detail window valves and main segments in a detail window, those valves and main segments
do not have components defined in the Geo Window. When trying to pass
back after making state changes to those valves and segments the user will
receive the error message : "Object variable or With block variable not set" for
each of those modified components. We have been able to find two
workarounds for the customer: Option 1: For each component that needs to
be passed back the user can create temporary components in the geo window
and the pass back will succeed and have the correct feature information.
Option 2: For each component that needs to be passed back the user can place
work points in the detail window and the pass back will succeed and have the
correct feature information.

Resolution: Avoided the error message and ignoring the features with no
primary geographic geometries for passback.
4.

1
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.17001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


5. 1-KT1N6R G/Technology Problem with read-only
1-KU0GSB Analyst connections when two users Resolution: Read-only component views are now ignored
are editing the same
geometry.
6. 1-KJH1KT G/Technology An error is displayed and map When customer WMS is configured in the legend, an error is displayed and
1-L9POF1 NetViewer is not loaded when WMS is map is not loaded for NetViewer and connection is logged out. The login page
present in the legend is shown again.

Resolution: The WMS legend entry having error is now handled and Netviewer
no longer crashes.
7. 1-DYJR3J G/Technology "Export To CAD" produces Spatial filtering based on intersections is not filtering correctly for secondary
1-L9POFB Designer DWG file with missing data records in geographic coordinate systems.
while using GeoMedia Resolution: The secondary records in geographic coordinate systems are now
SmartStore DDC filtered correctly.
8. 1-DYJQQD G/Technology GTECH crashes while Spatial filtering based on intersections is not filtering correctly for secondary
1-L9POIX Designer downloading the legend with records in geographic coordinate systems.
display status off for WMS Resolution: The exception is now handled and log message added to
legend entries. GDOWMS_Detailed.log.
9. 1-M0HDY3 G/Technology Predefined Legend Filter and Using the predefined filter with a saved workspace results in predefined filter
Administrator saved workspace being greyed out after removing the filter.

Resolution: Populate the pre-defined filter when a saved workspace with pre-
defined filters applied is opened.
10. 1-BCDXZ3 G/Technology G/Designer - Export to CAD Export to CAD fails when exporting the facility data within the selected design
1-QI136L Designer fails when exporting to area to NetExport output format.
NetExport output format
Resolution: Export to CAD now exports the facility data within the selected
design area to NetExport output format with no error.

2
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.16001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


11. 1-7JRHMN G/Technology Error during placement for a After opening a saved workspace with attached raster, an error is displayed during
Designer saved WS with attached raster placement when the cursor is moved over the raster.

Resolution: The automation code was added and now snap, pickquick, feature
placement are all working.
12. 1-8X6GZ1 G/Technology Hungarian localization of GT Request to have the localized resources included in a build once they are provided by
Designer 10.02.0002.06003MR the region.

Resolution: 10.2 SP2 is localized for Hungarian.


13. 1-97H3D0 G/Technology Request latest localization fixes Several fixes to localization and new languages are available. Pull these latest fixes and
Designer and files be included in the next files with the next maintenance release of G/Technology 10.2 SP2.
build of 10.2 SP2.
Resolution: Update localized resources and deliver new resources.
14. 1-9B2ZB3 G/Technology Deliver string files for Russian, The following files are not included in the
NetViewer Chinese, and Romanian for C:\Program Files (x86)\Intergraph\GTechnology\Program\GViewerApp\Resources
NetViewer. folder when NetViewer is installed:
Chinese Simplified - Strings0004.txt, Strings.ZH.resources
Russian - Strings0019.txt, Strings.ru.resources
Romanian - Strings0018.txt (there is an Strings0008.txt that is actually for Romanian
but is named incorrectly, it should be 0018)

Resolution: Add strings files strings0004.txt and strings0019.txt. Rename


strings0008.txt to strings0018.txt
15. 1-A1RTZ3 G/Technology New Raster Image fails to load If WMS data is included in the schema, creating a new raster image fails to load the
Administrator raster. The error is
Unable to load <fullpathofimage>220080w_BR.tif.

Resolution: Instead of name-based index changed to FNO based index. G/Technology


calls the correct (Raster Feature) FNO.
16. 1-AXWUTK G/Technology Attaching of Microstation V7 When users attach a MicroStation V7 DGN file, the drawing shifts Designer.
Designer DGN file shifts the drawing in
Designer
3
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.16001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


Resolution: Fixed the problem to use the active view extents that is attached for
calculating the extents during attach operation in Designer. Also, resolution (“points
per sub-unit” of the dgn file) is used during attach operation.
17. 1-BK7QOP G/Technology Receiving "Undomanager failed Users see "Undomanager failed to commit" error while trying to edit or place new
Designer to commit" error while trying to features while an AutoCAD drawing is attached as vector data. The error occurs
edit or place new features whether the AutoCAD drawing is attached using Coordinates or Registered.

Resolution: Handled the case where the source coordinate system is the same as the
target coordinate system during the attach vector workflow.
18. 1-BC35HG G/Technology Plot redline text size is For some plot redline text, the size as exported to AutoCAD does not match what is
1-D7T5FT Designer inconsistent in SaveAsAutoCAD displayed in the plot window. For one custom font, the text appears smaller in
output AutoCAD, and for one style using Arial the text appears larger in AutoCAD (especially
width).

Resolution: 1. Negative Internal leading - This value is now considered during font
handling. 2. Symbol in character A - If the symbol in character A of the font file is
removed, the overlap of symbols is not observed.
19. 1-D83OTM G/Technology Unable to attach MicroStation V8 Sample design file will not attach using the G/Technology Attach command. Users tried
Designer design file using the Attach using a provided CSF file as well as control points. The Attach command failed with the
command. error message: Normal Command with ProgID of GFrammeCommand.AttachData
failed in Activate().

Resolution: Integrated the fix so that ComplexStrings can now be attached.


20. 1-DPMUW6 G/Technology Designer crashes while trying to Designer crashes while trying to manipulate vertices of a pipe with the specific vector
Designer manipulate vertices of a pipe data.
with the specific vector data.
Resolution: Check for the condition in which if instance of the external software is
null, do not locate the vector layer.
21. 1-DPO9YZ G/Technology PublishCADFiles.exe failing when PublishCADFiles.exe attempts to process a given design file but ends up failing with
Administrator processing Microstation design error : "External component has thrown an exception".
file
Resolution: Fixed the problem so that PublishCADFiles will publish to DDC when color
and weight are applied ByLevel in a MicroStation design file.

4
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.16001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


22. 1-DVFR60 G/Technology Incremental Subset publish When doing an incrmental publish, almost all the data from a couple of ddc files was
MobileViewer brings all data as deltas brought into the UDT file as deltas which resulted in a huge size for the UDT file.

Resolution: When comparing identical GMBoundaries, if both had no holes, it


mistakenly flagged them as different and included the new one as a delta. This is fixed.
The .udt file created by publishing an incremental subset does not include any deltas
which are the same data between in full and incremental subset mapfiles.
23. 1-7E916T G/Technology G/Technology Designer crashes When users run the erase raster operation, G/Technology Designer crashes complete.
1-EDS8MF Designer completely when using the erase It is not possible to save the workspace. The function saves the new raster in a new
raster operation folder before crashing.

Resolution: Fixed the issue so that G/Technology does not crash during erase raster
functions.
24. 1-8X670M G/Technology Deleting multiple features results Users see a failure when deleting multiple features with the same FNO. Deleting a
1-EDS8ON Designer in DeleteAllRelationships error single feature works as expected.

Resolution: A check is added to ensure the correct iteration of recordsets when


checking for ownership children that should be considered for deletion.
25. 1-6QBZKI G/Technology Geometry tab display in Feature In NetViewer, the Geometry tab for a Raster-Feature is displayed as a Polyline in
1-EDS8R5 NetViewer Explorer for raster features Feature Explorer, and the dialog tab does not show any coordinates.

Resolution: Retrieved the selected Raster Geometry polygon points and displayed
26. 1-DB6T3J G/Technology Deltas Performance Deltas Performance improvement: Add rough index over the MapFile Offsets in the
1-EDSYA1 Analyst improvement: Add rough index Deltas structure. For component views that have many Deltas, the current processing
over the MapFile Offsets in the algorithm is not efficient.
Deltas structure.
Resolution: Even if a component view has many Deltas, the Deltas processing works
faster.
27. 1-DRZDX5 G/Technology Ownership established despite A point feature Sew-Connection Point exists on a linear feature Sew-Pipe. "Ownership
1-EDSYC9 Designer closing the pickquick with the red Sewer" is established between both features with Sew-Pipe as owner.
X
Resolution: The IGTRelationshipService's interior (simple) ownership relationship
processing has been corrected so that a second instance of the IGTRelationshipService
does not affect the first instance.
5
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.16001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


28. 1-9K1FFK G/Technology Error while logging into Users see an error while logging into MobileViewer.
1-EDSYEH MobileViewer GMobileViewer
Resolution: G/Technology displays a message by detecting a wrong configuration.
29. 1-95FX1W G/Technology Pass Back failing when Users have a workflow where Pass Back fails when components only exist in a detail
1-EDSYGP Designer components only exist in detail window.
window
Resolution: Avoided the error message and ignore the features with no primary
geographic geometries for passback.
30. 1-BRWFJT G/Technology Delete method on functional When placing a new component, for example (a Misc Text component), the Delete
1-EDSYIX Administrator interfaces are firing multiple method on the functional interfaces assigned to attributes on that component is being
times when placing a new fired mutiple times before starting the placement of the component in dynamics.
component
Resolution: The issue of Delete event being fired multiple times is fixed by suppressing
the delete call for AddNew.
31. 1-EKA1O5 G/Technology Attached DGN file does not The line string width is not correct when using ad hoc Attach CAD command.
Designer appear correctly. The styles
aren't applied. Resolution: Integrated Line style code changes from a third party source (from Teigha
version 4.0 to 3.8).
32. 1-EMPL9P G/Technology FOW Fiber Path Report and Fiber Clicking on a feature in the result set works in the geographic map window. In a detail
Designer Usage Report errors in Detail window it seems to work but it also throws an error. This is true for both Fiber Path
Windows Report and Fiber Usage Report.

Resolution: The fix restricts this query to just the G3E_FNO and G3E_FID columns
needed to identify the detail owner, so it does not inadvertently select a geometry
column that ADO cannot process.
33. 1-EXBQOG G/Technology NetViewer client on a NetViewer client on a MobileViewer machine does not use local FileUNCPaths.xml for
MobileViewer MobileViewer machine does not hyperlinks.
use local FileUNCPaths.xml for
hyperlinks Resolution: NetViewer client on a MobileViewer machine looks for hyperlinks in all
folders in the main FileUNCPath.xml and field FileUNCPath.xml.
34. 1-EYJBBH G/Technology Line styles display incorrectly in Line styles display incorrectly in attached dgn files if the window is rotated. When
Administrator attached dgn files if window rotated, the dash, dot, gap patterns strech.
rotated.

6
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.16001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


Resolution: To get better results the administrator must set UseDgnCacheRegen=1
and LinetypeScaleMultiplier and
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Intergraph\GFramme\02.00\DG
NDefaultLineStyleNumPatterns to a value that gives good display in respective DB.
35. 1-F2CJTX G/Technology Attach vector data functionality Attach vector data functionality does not interpret base unit correctly from CSF file.
Designer does not interpret base unit
correctly from CSF file Resolution: Fixed the issue by considering the “points per sub-unit” instead of master
units to attach a dgn file.
36. 1-F2FWQZ G/Technology Deltas is too slow, so add FID Deltas is too slow, so add FID Traversal mechanism.
Analyst Traversal mechanism
Resolution: The software includes an internal FID traversal mechanism to speed up
Deltas, especially those component views that have thousands of Deltas.
37. 1-EPMS5R G/Technology Data is incorrect on the screen Data is incorrect on the screen when the job environment changes.
1-F2G65B Analyst when the job environment
changes. Resolution: The screen now shows the correct data, even when the job mix changes.
38. 1-F6JME5 G/Technology Fix integration problems with Fix integration problems with new Deltas logic.
Analyst new Deltas logic.
Resolution: Product now works as expected.
39. 1-JMOZOH G/Technology Source pair counts not available While placing a piece of equipment in a connected network, Feature Explorer does not
Designer while placing an equipment display available pair counts to connect the equipment. The source count is displayed
when the user goes back to edit the feature.

Resolution: Corrected the issue so that now Feature Explorer displays available pair
counts with placement.
40. 1-JN615J G/Technology The existing relationship is When placing a new feature, the G3E_OWNERSHIP relationship is triggered from
Designer getting transferred from existing G3E_OWNERFNO to G3E_SOURCEFNO. The result is that existing relationship is
feature to the newly created one. transferred from existing feature to the newly created one, which is not what is
defined in metadata.

Resolution: The issue is corrected so that when users place a new feature with prompt
off for both Ownership and Interior, then the placement of this feature does not
override the G3E_OWNERFNO of the source feature.
41. 1-FEDU9Z G/Technology If a configuration does not have If a configuration does not have any raster components defined, then geometry
1-JSPOY5 Analyst any raster components defined, operations could fail.
7
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.16001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


then geometry operations could
fail Resolution: Even for configurations without raster images, geometry operations
succeed.
42. 1-EOH4TO G/Technology G3E_ATTRIBUTE.G3E_FOREIGNKE Users see an issue in Feature Explorer where the foreignkeyfield contains a single
1-JSPP03 Designer YFIELD - ORA-01756: quoted quote.
string not properly terminated
Resolution: Replaced the single Quote(') by Doubling('') them.
43. 1-DGAI68 G/Technology Receiving "Subscript out of Users have defined a picklist which will set the phase for a feature. Originally, the
1-JSPP2L Administrator range" when using picklist to set picklist included a functional interface. We have removed the functional interface
phase from the attribute and users still receive the error message "Subscript out of range".

G3E_CNO = 10202
G3E_FINO = 71
G3E_ATTRIBUTE = 10202013
G3E_PNO = 174
Database Table = VL_PHASE

Resolution: Events are handled.


44. 1-JT643T G/Technology Error in query results if the Error in query results if the feature does not have graphic components in the
Designer feature does not have graphic geographic map window.
components in the Geo map
window. Resolution: Fixed the problem to handle queries for features that have primary detail
component and no primary geographic component defined.
45. 1-ELM5OE G/Technology Memory consumption grows Users see growing memory consumption in the validation process without completely
1-JZGKRX Designer during Validation and is not releasing it after validation completion although object variables are cleared and set to
released afterward. Nothing, e.g.
oOwnershipObjects = oRelService.GetRelatedFeatures(iOwnershipRno)

Resolution: Changes have been made to the Validate Job Edits command to improve
memory management.
46. 1-61C95M G/Technology raster bulk load does not work During bulk load image of color tiff raster files this error message is displayed. The
1-K8C3ED Administrator with color geotiff selected raster images do not have the same format necessary for transparent color
specification. After selecting OK on the error, the multiple tif files are deselected.
Users do not want to use any transparency, just to register raster files.
8
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.16001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce

Resolution: Now the user will not get the error message. The Colors button will be
disabled if the raster images do not have the same format for transparent colors or the
user has selected a mixed set. Only one file can be selected at a time and loaded using
the bulk load image command.
47. 1-6O4B8A G/Technology Alternate component geometry In a model where there are Geographic and Alternate component for each feature,
1-K8C4TH Designer appearing in Geographic window when the user places the primary geographic component the primary alternate
and vice versa component is also placed. If an alternate component is added to the feature, again the
component is displayed in the geographic and alternate window.

Resolution: Enhanced the logic in Feature Placement Service and other editing
components, such that the edit/placement of geographic and alternate components is
allowed in respective windows only.
48. 1-6X8V9Q G/Technology Metadata Explorer: Recording When updating through the Metadata Explorer, the SQL needs to be recorded to be
1-K8C59L Administrator renaming of attributes creates no run on other environments. Only the Rollback or Commit is recorded in the SQL script
SQL output file when setting the Conduit Total Length to Designed Length.

Resolution: Modified the execute call in such a way that it drops the temporary tables
which are created when recording the SQL script.
49. 1-701TRK G/Technology PublishSubsetService keeps PublishSubsetService keeps running when generating an incremental subset but stops
1-K8C5IR MobileViewer running when generating an generation output.
incremental subset but stops
generation output Resolution: Moved MoveNext call out of If there is fields statement. PublishSubset will
not hang processing tables where all fields have been role filtered out.
50. 1-6WCZK1 G/Technology Export to AutoCAD does not Export to AutoCAD does not invert colors like it does when export is done to
1-K8C5MN Designer invert colors like it does when MicroStation DGN format.
export is done to MicroStation
DGN format. Resolution: Fixed the problem so that the Export to AutoCAD command exports the
white colored features in white.
51. 1-7KJ7NP G/Technology Error is displayed when Error is displayed when attempting to locate attached CAD or raster images.
1-K8C5SR NetViewer attempting to locate attached
CAD or raster images Resolution: Corrected the issue so that now if users try to locate any feature in a CAD
file, no error is displayed.

9
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.16001
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


52. 1-7MNRCZ G/Technology Problems with attach V7/V8 DGN Users encounter the following problems during attaching V7/V8 DGN in G/Tech
1-K8CDRZ Administrator 10.1.0002.17001.

1. Rotated text is found in V7 DGN, but it is not found in V8 DGN (Case 1). The text is
not rotated in the original V7 or V8 DGN.
2. Some special symbols are found near the leader lines in V7 DGN, but they have a
different look or do not exist in V8 DGN (Cases 2 and 3). No special symbols are found
at the same location in the original V7 or V8 DGN. (The V8 DGN is upgraded from the
corresponding V7 DGN)

Resolution: Fixed the problem so that text appears in G/Technology as it appears in


MicroStation and no extra symbols appear.
53. 1-6GYVNA G/Technology Export to PDF produces a blank G/Technology produces blank or snowy pdf files for some raster files registered in the
1-K8CDTD Designer pdf or snow for some raster files database. The same results are received with an attach raster image. On a 32-bit
on 64 bit systems system, both raster feature > load image and attach raster export to pdf successfully.

Resolution: The non-rotated image rendering takes the code path of rotated images in
the case of a 64-bit operating system and prints the result successfully.
54. 1-62W07G G/Technology Attaching a v7 MicroStation dgn Attaching a v7 MicroStation dgn file has rotated text.
1-K8CDVV Designer file has rotated text.
Resolution: Fixed the problem so that text appears in G/Technology as it appears in
MicroStation, and no extra symbols appear.

10
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.15001 -.15004 Released 9/1/15
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


1. 1-BUC8FF G/Technology User unable to create a detail for a detail feature, The error message below is displayed when a user
1-D8TMWL Designer DetailinDetailPVT failure tries to open a detail window for detail feature:
Unable to update with changes made to the last
component
Complete Component Relation List:
Error in ComponentComplete
: Failed in PopulateDetailInfo
Error getting feature information:

Resolution: Placing detail component indicators works


as expected.
2. 1-BPR3BS G/Technology Error while placing cable section in detail window Users see the error below after placing a cable:
1-D8TMUD Designer Unable to start placement of next component
Unable to start placement technique
GFPlaceTech.OffsetPointSPT
Unable to process relationships for this silent or
derived component:
Establish Relation List:
Error in EstablishRelationship
Error finding recordset on which to set Detail ID :
Error in EstablishRelationship
Error finding recordset on which to set Detail ID :”

Resolution: The software filters the


G3E_DETAILS_OPTABLE so that the correct detail
component is found to set the Detail ID.
3. 1-BFZTJH G/Technology Error in Reestablish Relationship A user sees an error ‘Error in ReestablishRelationship.’
1-BEEUZH Designer while trying to create new detail window using Edit >
Relationships > Reestablish References a Detail.

Resolution: The problem occurred when a component


other than the Detail Referencing Component was
either 1) selected when in "Only Selected
Components" select mode or 2) not the first
11
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.15001 -.15004 Released 9/1/15
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


component in the Feature when in "All Components"
select mode. The Detail Referencing Component is
now used regardless of how the Feature/Component
is selected.
4. 1-BGWHHF G/Technology Ghost copy observed for Rotate Around and Select the geographic component and alternate
1-D4LH4L Designer Manipulate vertex operations component using Edit Tool. Now perform Manipulate
Vertex and Rotate Around operations. Observe that
the ghost copy of an alternate component is visible in
the active window.
5. 1-CF42T9 G/Technology Deltas handling of large geometries caused Deltas handling of large geometries caused a system slowdown. A
1-D4LGZB Analyst slowdown geometry with 183K points takes 5 minutes to process. That
slowdown is due to two issues:
- In some cases, Deltas is processing a geometry twice.
- Deltas is not efficient in handling large geometries.

Resolution: Large geometries are processed quickly.


6. 1-ANCIE9 G/Technology IGTLocateService.PickQuick is not honoring Located When the IGTLocateService.PickQuick method is used in a custom
1-D4LGX3 Designer Features -> Maximum Number configuration command, it always lists 10 items in the PickQuick dialog,
regardless of the number configured in the Tools > Options dialog
box. GTLocateService.Locate() always displays 10 items in the list,
even though the MaxCandidates property is set to greater than 10.

Resolution: Max Locatable objects setting is honored when the


IGTLocateService.PickQuick method is used in a custom command.
7. 1-8URVIP G/Technology Error opening saved workspace An error occurs when a user opens a saved workspace.
1-D4LGRJ Designer
Resolution: The workspaces are not recoverable. This fix creates a
system-generated window so that the workspace can come up and
the user can get any equity out of it, like named plots, job name,
queries, and so forth. This fix also avoids the system asking Save
changes to ....
8. 1-B72AOO G/Technology Map background is not properly set when the The map background is not properly set when the contents of a
1-D4KPX5 Designer contents of map frame is refreshed in plot window. map frame are refreshed in a plot window.

12
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.15001 -.15004 Released 9/1/15
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce

Resolution: The map window background color is retrieved while


changing the map frame legend.
9. 1-870L1P G/Technology Browse for Detail gives ORA-0904 error When selecting an existing detail from Open Detail Window
1-D4KPUX Designer (Window > Open Detail Window), an error ORA-00904 displays:
"DETAIL_USERNAME": invalid identifier is displayed. The error
occurs as soon as a detail is selected and before clicking OK.
The same detail can be opened when the inventory feature had
been selected previously in the map.

Resolution: The code to use


G3E_DETAILS_OPTABLE.G3E_USERNAMEFIELD value to get the
detail drawing name correctly.
10. 1-7P6G5E G/Technology Unobtainable error while publishing data An unusable error displays while publishing data.
1-D4KPSP Administrator
Resolution: The error is shown along with the FID when geometry
error occurs during publish.
11. 1-9OIPAZ G/Technology Only one component moves in the map window When primary and alternate components are selected in map
1-D4KPQH Designer and alternate window. window and alternate window and when users run Edit Too l >
Move command, then only one component is moving. Both
components are expected to move to new location.

Resolution: Fixed the issue so that move operation is performed


without any problem when multiple components are selected in
geo and alternate windows.
12. 1-9W1YUT G/Technology Quick Reference Find shows incorrect result The Quick Reference Find command displays an incorrect result.
1-D4KO3B Designer
Resolution: Displaying appropriate message before showing all
records returned by the query when processing only geographic or
all primary graphics fails to return any result.
13. 1-9CCAW9 G/Technology Attribution changing when creating a new job but Users have defined several job classes in G3E_JOBCLASSIFICATION,
Designer current job remains active among others: Capture-Job and Planning-Job.

13
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.15001 -.15004 Released 9/1/15
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


G3E_COMMONJOBCLASS is configured to preload some attributes
depending on the active jobclass.

Resolution: Active job classification is applied to the active job.


14. 1-C20V6X G/Technology Attaching Raster Backdrop is not registering file Users are trying to attach a raster parcel layout using Precision
Designer correctly Coordinates. The first point placed correctly. The second, third,
and fourth point placed way off the map. They used General
Symbol line using the same precision coordinates to draw a box
that seems to give them what they expected.

Resolution: Because coordinates in the source registration window


are not geographically meaningful, mouse clicks in the source
registration window are ignored by the Precision Coordinate
Control, and coordinate key-ins are not allowed when the source
window is active.
15. 1-BC3BSR G/Technology Yellow text appears in the plot window PDF or print Yellow text appears in the PDF or print output of a plot window.
1-CMZY1P Designer
Resolution: During redline placement, the records are now added
only if the styleID is set. Also, during Export to PDF, verification is
added for record sets. Now the yellow text is not a part of output
recordsets or the PDF.

16. 1-C2H929 G/Technology Conflict Detection GUI changes The Conflict Detection dialog does not use G3E_USERNAME
Designer values. The dialog uses component table names, column names,
FNOs, and CNOs which are values that the end user is unfamiliar
with. A user cannot maximize the dialog to display more attributes
for components with large numbers of attributes. The Master
Record/Job Record identifier column in the Master/Job grid is not
fixed, so when the user scrolls they cannot identify which row is
the Master record and which is the Job record.

Resolution: Altered the dialog box grids to display localized strings


or G3E_USERNAME values for column headers and
G3E_USERNAME values for FNO and CNO values. Enabled
14
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.15001 -.15004 Released 9/1/15
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


maximizing the dialog. Removed the Master Record/Job Record
identifier column and replaced with labels.
17. 1-CXIVF3 G/Technology Additional conflict detection enhancements 1. Sort fields in conflict to the left of the Master/Job grid
Designer 2. Make changes to the Apply button to make it clearer to users
exactly what it does.
a) Maybe change the frame label from Conflicts for
<component_name> to Conflicts for <component_name>
Component
b) Maybe change the button label from Apply to Apply
Component Changes

Resolution: Ordered the columns in Master/Job grid so that


columns with different values, which are highlighted and editable
are the left-most columns in the grid. Changed the labels of Apply
button and Master/Job frame to indicate that changes are applied
at a component level.
18. 1-BVHAQB G/Technology Performance issues when deleting legend filters Since receiving a fix for adding legend filters when called from a
Designer when called from a custom command. custom command, the user says the performance is bad when
removing those same filters when they are called from a custom
command.

Resolution: The performance with the fix is almost 10 times faster.


19. 1-BOQQ9O G/Technology Tile alignment issue seen in transformation case. The tile alignment issue is seen in three cases:
1-BOUHA3 Designer  Transformations (coordinates system of WMS data and
G/Technology data do not match)
 When multiple tiles are rendered in G/Technology
 When printing to hardware printer and generating PDF using
Export to PDF command.

Resolution: Make changes to software to improve alignment.


20. 1-AQ2IU8 G/Technology Z values when 3DSupport is inactive When 3DSupport is inactive
1-BOQVQR Designer (G3E_GENERALPARAMETER.G3E_NAME=3DSupport,
G3E_VALUE=0) Z lock and Element Z are disabled. You can enter

15
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.15001 -.15004 Released 9/1/15
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


values in the Active Z box which will be written to the database. If
3DSupport is disabled, the Active Z entry box should be disabled.

Resolution: These fields are disabled when 3DSupport is set to 0.


21. 1-ASCLPP G/Technology Upstream OTDR is not working properly Upstream OTDR is not working properly.
Analyst
Resolution: OTDR cumulative length trace for Upstream and
Downstream is correctly calculated.
22. 1-AEEKQ3 G/Technology MicroStation DGN not displaying correctly for MicroStation DGN files do not display correctly for output to paper
NetPlot Server paper outputs plots.
For example,
1. Bolded fonts are showing up not bolded.
2. Line styles that include dots/dashes only display dashes.
3. The actual output seems lighter to the user.
The same plots using G/Technology 10.1 SP3 looked totally
different to the user.

Resolution: Fixed to handle "Bolded fonts are showing up not


bolded" and "The actual output seems lighter to the user".
23. 1-B506S1 G/Technology IGTBreakLinearService does not allow breaking a When using the IGTBreakLinearService in a custom command to
1-BATYER Administrator cable between two sections. break a cable with two linear sections, the
IGTBreakLinearService.Execute method throws the exception
"BreakPoint cannot be coincident with end point" when the
breakPoint is exactly the end of first section or start of second
section. The break works as expected when placing a splice
manually in communications at the same location.

Resolution: The IGTBreakLinearService Execute method allows a


multi-section component to be broken at an endpoint of a section
if that endpoint is interior to the overall cable.
24. 1-AP5Y3X G/Technology Print preview changing after making changes to By default, measurement settings for ground units are set to
Designer measurement settings. meters. Modifying ground units to feet causes the print preview
functionality to display incorrectly.

16
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.15001 -.15004 Released 9/1/15
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


Resolution: Added a conversion factor to translate the units to
match the ones selected in the measurements option.
25. 1-ALXR5V G/Technology After upgrading to 10.2 SP2 it is no longer possible Publish subset for any single region fails after upgrading to the
MobileViewer to publish single-region subsets latest 10.2 SP2 build. However, the Publish all regions option
works as expected.

Resolution: Publishing a subset with one region now works.


26. 1-AA7TSB G/Technology Toolbars saved on secondary monitor cannot be If a user saves any floating toolbar (including Feature Explorer) on
Designer restored to primary monitor if there is one the second monitor, and then goes to a system that has only one
monitor. monitor (or undock their laptop), then the floating toolbar is still
on the second monitor. There is no way to reset the toolbars or
Feature Explorer without deleting the registry keys. The work-
around, is to move all items to one screen before saving the
workspace.

Resolution: If dockable controls and toolbars are persisted on a


second screen and that screen is no longer available when the
application is started, the dockable controls and toolbars are
automatically repositioned to the one available screen.
27. 1-AI81UL G/Technology Plot window text disappears when moving the Text Plot window text disappears when moving the text geometry.
Designer geometry.
Resolution: The software displays the text/point redlines while
moving, similar to other redlines in a plot window.
28. 1-AXA0NZ G/Technology Significant performance issue when adding filters The user reports a significant performance degradation in
Designer to legend entries. G/Technology 10.2 compared to 10.1 when programmatically
(using a custom command) resetting the legend entry filter on all
items in the Display Control.

Resolution: Made corrections in the software to improve the


performance as seen in earlier versions of G/Technology.
29. 1-DC51EV G/Technology An error message is thrown when a workspace When a user opens a new plot window, an error message displays,
Designer with plot window is opened and user cannot and if cancelled, the same message displays again. The user cannot
continue perform any operation and cannot exit G/Technology. The same

17
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.15001 -.15004 Released 9/1/15
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR# Product Summary Description/How to Reproduce


issue is observed if a user opens a saved workspace that contains a
plot window.

Resolution: Fixed the problem by adding a check if the


ActiveMapView type is GMMapView.

18
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.14001 -.14004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


1. 1-AADLBL G/Technology Unable to break a feature using a custom Unable to break a secondary conductor feature using
1-AEF1F5 Designer command. CustomCommandModelessBreakLinearService custom command.

Resolution: The event methods are now being checked. If the call is for .NET, only
the changed parameters are sent to the event. Other cases are reverted to a
previous event method. The VBA event is now working.
2. 1-AADLCT G/Technology Unable to move a feature using custom Unable to move a secondary conductor feature using
1-AEF1H3 Designer command. CustomCommandModelessGeometryEditMoveFeature .

Resolution: The event methods are now being checked. If the call is for .NET, only
the changed parameters are sent to the event. Other cases are reverted to a
previous event method. The VBA event is now working.
3. 1-9LIZ6M G/Technology Font display changing when zooming in. Some fonts display differently at different scales in the detail map window. Font
Designer display also changes with angle settings. If font is placed zero degrees, there are
no dashed lines.

Resolution: Fixed the problem by improving the rendering quality for a given font.
4. 1-93F50J G/Technology Job Query Issue When using the job environment function and adding in the following criteria:
1-9V7R7T Designer
Filter Jobs: All users
Column: Job Owner
Operator: like
Value: %

Error: ORA-01427: single-row sub-query returns more than one row.

Resolution: The query used for job data retrieval was framed incorrectly. In case
of columns that have picklist values associated, two queries are used. The sub-
query needs to use the selected operator and the main query uses = any.

19
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.14001 -.14004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


5. 1-9563J8 G/Technology CustomCommandHelper MouseClick The CustomCommandHelper MouseClick event fires twice when two custom
1-AAVHIT Designer event fires twice commands with the MouseClick handler are active in the same time.

Resolution: The event caller and the current handler's interface details are
compared. Hence, among the list of the handlers for an event, only one handler
will match and others are not executed. Thus the handler/method of the current
custom command only will be executed.
6. 1-99M338 G/Technology Job query issue For Jobs > Job Environment > Add > Current User / All Users, the operator "does
1-9V7R7J Designer not equal" is not excluding the selected value from the returned job list for the
columns with picklists.

Resolution: The query used to retrieve the data was framed incorrectly. It had
two NOT operators - one in the main query and one in a sub-query. A fix is
provided to use the NOT EQUALS operator only in the sub-query.
7. 1-9WU7W0 G/Technology G/Technology is crashing while plotting G/Technology is crashing while plotting.
1-AAVHMP NetPlot Server
Resolution: Fixed the problem so that a user can now submit the same plot
multiple times.
8. 1-A615LD G/Technology AutoCAD DWG file containing linestyle A user attached an AutoCAD DWG file containing a linestyle with text and
Designer with text is not visible when attached observed that text in the linestyle is not visible in the attached file. The user saved
the same file as a DXF file and attached the file in desktop. The text in the linestyle
is visible.

Resolution: Fixed the problem so that text in the linestyle is visible on attaching
AutoCAD DWG file.
9. 1-A23C8L G/Technology Export to DGN is not extracting secondary When exporting secondary data that has not been imported, the text and symbol
Designer symbols and text. features defined in the secondary metadata are not being exported. Linear
features are being exported correctly. The user receives the error message
"Cannot get Alternate Coordinate System Path with given name. Ensure that
name is correct and retry." The output is created, but there are no symbol or text
features exported. If the user turns off the symbol and text features in the Display
Control, the data is exported correctly with no error message.

20
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.14001 -.14004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: Fixed the problem so that text and symbol features defined in the
secondary metadata are exported by reading the geometry field name from the
component info optable.
10. 1-9KYBQ4 G/Technology An error message is displayed after A user sees the following error while invoking G/Technology desktop application
1-A271C3 Designer invoking G/Technology after installing the build silently on a clean Windows 7, 64-bit machine:

“C:\Program Files (x86)\Intergraph\GTechnology\Program\G3E.exe


The application has failed to start because its side-by-side configuration is
incorrect.

Resolution: VC9.0 system dlls are being delivered. Reset the VC9.0 msm to use the
Installshield versions and not the version in Program Files\common
Files\MergeModules.
11. 1-9L4ZB1 G/Technology NetViewer produces maps with incorrect NetViewer produces maps with incorrect colors when displaying a lot of data
1-A2712D NetViewer colors when displaying a lot of data (aerial (aerial photos).
photos)
Resolution: Introduced a new DWORD under
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Intergraph\GNetViewerServ
er\09.00\MapServers named as MostUsedColorsPNG. This has to be set on the
NetViewer server and MobileViewer. Set MostUsedColorsPNG to 1 to use Most
Used colors palette to get correct fill colors in facility data and set it to 0 to use
Avg colors to get good colored raster. Default value for this key is zero.
12. 1-9Y2A29 G/Technology Unable to see fonts when a exported file is Zoom to an area in the map window and then export the content to DGN format.
Designer attached Try to attach that file. Expected fonts in the attached file are not visible. Fonts are
visible in the native file format, and both export and attach uses font resource
files from different locations. When users close the workspace and then attach
the same file, they could not see the fonts.

Resolution: Fixed the problem so that the resource files for attach are being used
even though the exported DGN file with the same resource files is attached in the
same instance.

21
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.14001 -.14004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


13. 1-54EG2Z G/Technology Move Related feature dialog does not Using Industryware G/Comms, users tried to move a fiber splice enclosure that
Designer display all the related features has a node ordered input /output relationship with two conductors. The splice
only picks up the node ordered input feature. Users tried to randomly pick several
point features that have node ordered relationship, and they always return the
node ordered input side.

Resolution: The software properly determines the subordinate relationship and


displays all the related features as candidates to move with the selected feature.
14. 1-9QXJEF G/Technology Display scale dependent check box cannot Display scale dependent check box option in the Display Control tree view is
NetViewer be disabled in the Display control tree automatically turned off in NetViewer, even though the user does not have the
view. permission to turn it on/off.

Resolution: Display scale check box is still disabled when users click Display status
or Locate Status check box if the user does not have the role to turn it on/off.
15. 1-9FOTW5 G/Technology Export to CAD > custom stroke pattern not Export to CAD > custom stroke pattern is not mapped to DGN stroke pattern when
Designer mapped to DGN stroke pattern stroke definition has values with decimals like 2,85.

Resolution: Provided the option to give DGN style value in


G3E_NORMALIZEDSTROKE.G3E_MICROSTATIONSTYLENAME

Existing G3E_NORMALIZEDSTROKE.G3E_MICROSTATIONSTYLENAME column can


be used to give DGN style for default line styles as shown below:

1. If G3E_NORMALIZEDSTROKE.G3E_UDLS is 0 and
G3E_NORMALIZEDSTROKE.G3E_MICROSTATIONSTYLENAME has a value between
0 and 7, then this value is used for default styles while exporting to DGN.

2. If G3E_NORMALIZEDSTROKE.G3E_UDLS is 0 and
G3E_NORMALIZEDSTROKE.G3E_MICROSTATIONSTYLENAME is null, then style is
picked based on the dash/gap sequences provided (which is existing behavior).

22
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.14001 -.14004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


16. 1-91QBIT G/Technology Circles and line styles are not displayed A display of circles and line styles placed in a DGN file which is attached to a
1-9JOU3H Designer correctly in attached DGN files G/Designer map window using the command Attach Vector Data depends on a
one CR scale of the map window when attaching the CAD file. When the scale number is
references bigger (for example, 1:500 000) the circle in the attached DGN file is presented as
circles, one set of lines. The lower map window scale number causes the smoother (better)
linestyles display of the circle in the G/Designer map window.

Resolution: Teigha supports caching and the software is currently using this
mechanism while attaching the DGN file in G/Technology. When caching is
enabled, a display list is created during the first draw, and then subsequent draws
are performed using the data in this display list, which gives a significant speed
improvement. To fix this problem, one has to regenerate the cache of the
elements that are visible in current map window.

A new parameter is introduced in the gt.ini file:

UseDgnCacheRegen=1 // For DGN cache regeneration

The default value is 0, which means caching is not regenerated, which is the
current behavior. Set this variable to 1 regenerate the cache of the elements that
are visible in the current map window while using zoom/pan operations and
attach the files to have best results. This setting will reduce the performance.
17. 1-6T5NAW G/Technology Plot redlines - Rotate function does not Plot redlines - Rotate function does not exit using the ESC key.
Designer exit using ESC key
Resolution: Added the missing condition for ESC functionality for plot redlines.

18. 1-9V0R8Z G/Technology Subscript out of range All users receive message "Subscript out of range" when there are more than
Designer 1000 ownerships involved.

Resolution: Removed fixed parameter array.

23
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.14001 -.14004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


19. 1-9NU11W G/Technology Editing an inner duct number throws error Editing an inner duct number causes an error.
Designer
Resolution: The assignment ANO (G3E_DUCT.G3E_ASSIGNMENTANO) for duct
and inner duct should not be included on Duct Configuration dialog tabs when the
dialog type is “Multi Review” and “Multi Edit”.
20. 1-9SQEGL G/Technology Update Subsets for incremental does not When running MobileViewer - Update Subsets for Incremental Updates, if there is
MobileViewer log an informative message when machine not enough space to create or copy the necessary files, the process fails.
runs out of space. However, the error that is logged does give not enough information for the user
to understand the problem.

Resolution: An error message box shows the log file name. Also, the log file has
more a specific reason for the failure.
21. 1-91GWJM G/Technology G/Technology does not pass Arguments When having .NET implementation of IGTForeignKeyQuery interface on tab
Designer into .NET IGTForeignKeyQuery attribute level with arguments (G3E_FKQARGGROUPNO), G/Technology does not
implementation pass arguments values to implementation. In VBA implementation of
IGTForeignKeyQuery, Arguments are passed as expected.

Resolution: The software first searches for G3E_FKQARGGROUPNO in


G3E_TABATTRIBUTE. If there is none, then it uses the one in G3E_ATTRIBUTE.
22. 1-AGYQXS G/Technology Plot window redline style: line with Plot window redline style: the line with arrowheads does not display the
1-9C4WSN Designer arrowheads not displaying arrowhead arrowhead correctly.
correctly
Resolution: Fixed the problem to display the masked symbols correctly.
23. 1-A6N8HT G/Technology Missing lines when a DGN file with custom Some lines are missing when a DGN file with custom line styles is attached
MobileViewer linestyles is attached to MobileViewer. through Attach Backdrop file in MobileViewer

Resolution: Fixed problem in renderer.

24. 1-8WOO5X G/Technology Common Attribute Edit Command: no file When editing common attributes for an attribute with G3E_FORMAT =
Designer selection is possible for an attribute 'Hypertext', there is no option to browse for a file in the common attributes
defined as Hypertext dialog.

24
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.14001 -.14004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: Fixed the issue by formatting the HyperText Attribute values as
hypertext and provided browse option in Edit Common Attributes dialog.

25. 1-AELYRZ G/Technology Unable to see the features in the map The user cannot see the features in the map window/plot window as clearly as
Designer window/plot window clearly as expected. expected.

Resolution: A new font file with hinting was provided. No code changes required.

26. 1-9SI0QP G/Technology Unable to fire G3EDUCTCONTROLEDITPKG The software is unable to call the G3EDUCTCONTROLEDITPKG when the user clicks
Administrator after Add Ducts in Duct Configuration Add Ducts in the Duct Configuration control.
control
Resolution: Added new logic to keep track of the ducts that are added through the
Duct Configuration tab and properly called the USERDUCTCONTROLEDIT
procedure with the list of FID and FNO values.
27. 1-A1YN89 G/Technology NetPlot Messages: NetPlot MSMQ and When using an operating system with a different language, the accented letters
NetPlot Server error messages are missing accented are missing from MSMQ messages as well as corresponding log files. For example :
letters and special letters Actual message in ExecPlotMan.log :
Benutzerunterbrechung ist w hrend des Vorgangs Load Data Service Connect
aufgetreten

The message should look like :


Benutzerunterbrechung während des Prozesses w Load Data Service Connect
aufgetreten

The "ä" is missing from "w hrend". The same results are in MSMQ.

Resolution: Previously, the response message sent back to NetPlotService by the


G/Technology, the software stripped all the extended ASCII characters in the XML
response message with a space. The extended ASCII character codes contains
accented letters which were missing from the MSMQ message. The purpose of
the TrimAll method is to remove all the non-printable characters only, so now the

25
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.14001 -.14004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


software selectively removes the non-printable characters from the extended
ASCII character range which is from 128 to 255.
28. 1-9DC0G0 G/Technology CF19 Panasonic Toughbook and On a Panasonic Toughbook, when users attach a legend, G/Technology crashes.
1-AX93AZ Designer G/Technology Designer Attach Legend
Resolution: Use TreeView from MSCOMCTL.ocx for MapWindowLegend
command to solve the problem.
29. 1-ALXR5V G/Technology After upgrading to 10.2 SP2 cannot Publish subset for any single region is failing after upgrading to the latest 10.2 SP2
MobileViewer publish single region subsets build. However, "Publish all regions" option works as expected.

Resolution: Made fixes so that a single region can be published.


30. 1-68OJ0I G/Technology Vector data changes its position as the With the map frame highlighted, if the user scrolls down or up the plot sheet, the
Designer user scrolls down the plot sheet. location of the vector data attached also changes.

Resolution: Fixed the problem to display CAD data in the correct location with the
map frame activation in the plot window. Also rotate map issue and locating the
CAD elements issues are resolved.

26
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.13001 and .13002
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


1. 1-9PQEX2 G/Technology Designer IGTExportService.SaveAsDGN does When exporting a plot window which has style substitutions
not recognize style substitution applied, the style substitutions are not applied to the exported
DGN file. Users see the substituted styles in the plot window, but
when exported, the original line styles are used in MicroStation.

Resolution: Fixed the problem so that the style substitutions are


now honored in exported MicroStation and AutoCAD files.
2. 1-9MGN65 G/Technology Designer Update GDOGML and Update GDOGML and GMWMSRasterEngine to the latest version
1-9PQOSD GMWMSRasterEngine to latest from GeoMedia which includes performance fixes for
version from GeoMedia. transformation, non-transformation, and rotated map workflows
while panning, zooming, printing to hardware printer and
generated PDF.

Resolution: Integrating all the changes made in GDOGML and


GMWMSRasterEngine from GeoMedia codeline until 08/21/2014
since the last integration done on 5/16/2013.
3. 1-9MVQ2L G/Technology Administrator In desktop, users see approximately When G/Technology users zoom in to a map window that
1-9PQP0P 53K GetMap calls which makes contains only one WMS legend entry (even though the WMS data
G/Technology freeze until all the is not visible in the current map window area), they get WMS
GetMap requests are over GetMap calls, and the count increases with each zoom in request.
At a scale of 100K, the tile count is approximately 53K in
G/Technology which causes a process hang while approximately
53K GetMap calls are processing. Similar behavior was observed
in NetViewer where the tiles count and number of WMS GetMap
calls reached approximately 9.68 million.

Resolution: The above issue was reproduced only in a non-


transformation case. G/Technology added logic to skip the draw
in this scenario.
4. 1-9MW8MN G/Technology NetViewer In NetViewer, the MapServer runs out When G/Technology users zoom in to a map window that
1-9PQP1T of memory due to 9.68mil GetMap contains only one WMS legend entry (even though the WMS data
requests is not visible in the current map window area), they get WMS
GetMap calls, and the count increases with each zoom in request.

27
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.13001 and .13002
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


At a scale of 100K, the tile count is approximately 53K in
G/Technology which causes a process hang while approximately
53K GetMap calls are processing. Similar behavior was observed
in NetViewer where the tiles count and number of WMS GetMap
calls reached approximately 9.68 million.

Resolution: The above issue was reproduced only in a non-


transformation case. G/Technology added logic to skip the draw
in this scenario.
5. 1-8DT4ZF G/Technology Designer Copy Partial Parallel Construction Aid After attaching a DXF file in G/Technology, use the Copy Partial
1-9PQOSN errors - either one vertex is missing or Parallel Construction Aid. Depending on where users place
G/Technology has to be terminated. points, the Construction Aid will either not pick up all the vertices
or users have to terminate G/Technology to exit out of the
placement function.

Resolution: Polygon entities are closed entities where the


number of vertices considered did not handle the last vertex.
This is due to an indexing problem during last vertex validation.
This is fixed, and the highlighting and selection is correct.
6. 1-909WHM G/Technology Designer Export to AutoCAD not exporting When users Export to AutoCAD, the labels in the AutoCAD file are
1-9PQOVZ labels missing.

Resolution: Text height is calculated when Geographic


coordinate system type is used while performing Export to
AutoCAD.
7. 1-9PCLKH G/Technology Designer The interior relationship processing Users placed workpoints so one workpoint was owned by an
1-9PQOQ5 does not update a feature if it has a existing feature. Users have tried to place a feature that
previous owner establishes ownership relationships with the workpoints during
interior relationship processing. The relationship was not
updated on the workpoint that had a relationship.

Resolution: Previously, if a relationship already existed,


G/Technology purposely did not overwrite that relationship. Now
because the product has introduced the ability to prompt for
28
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.13001 and .13002
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


interior relationships, G/Technology will update the existing
relationship with the current information.
8. 1-9LJ7R3 G/Technology Designer G/Technology is crashing while G/Technology crashes while exporting the map content to
Exporting map content to MicroStation (V7 or V8) format. This happens only If both
MicroStation (V7 or V8) format linestyle and font style resource files are in the same location,
and the name of the linestyle resource file is listed first in the
directory (sorted by name).

Resolution: Added a check to find if the file to be loaded is a font


resource file or not. If the first file in the folder is not the font file
specified in the FileUNCPaths.xml, then the second file is checked
and so on, until a font resource file is found. If a file resource file
is not found, then standard font is applied. This issue is also
resolved for API and NetViewer.
9. 1-9KZAXG G/Technology NetPlot Server NetPlot not honoring legend NetPlot is not honoring legend overrides after changing trace
overrides results from "RED" to "YELLOW".

Resolution: Fixed the problem such that the legend overrides are
persisted in the Web Client Context. The NetPlot request is sent
with updated legend overrides.
10. 1-961GRA G/Technology Designer Construction Aid Point By Distance or Users retrieved the sample project for a construction aid that is
Angle sample does not function delivered with G/Techncology. They built the .dll and changed the
database to hit the .dll from the sample code. The Initialize
function throws unmodified errors. After fixing one problem with
the active map window in the Initialize function, the function
places the points incorrectly. With the user inputting the length,
angle, and length of the arc, G/Technology places the point
around the origin for the y coordinate, regardless of where it is
started. It creates an enormous line far off the normal extents of
the data.

Resolution: Initialize method is fixed after resolving few objects


creation. The method is replaced with single line representing
the PROGRESS status of the CA. Angle calculations are corrected.
29
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.13001 and .13002
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Also a Boolean variable is provided in the sample code, which can
be used for determining if AZIMUTHAL calculations are needed or
ABSOLUTE calculations are needed.

30
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.12004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


1. 1-9K0G9H G/Technology Error after placing Fiber Splice Users see the error "An Item with the same key has already been added."
Designer Enclosure in Fiber Branch Enclosure after placing Fiber Splice Enclosure in Fiber Branch Enclosure

Resolution: A new overloaded method was added to the


GTBreakLinearService: GetBreakPoint.
2. 1-9JEUML G/Technology Optional parameters in attribute When optional parameters are defined using a mark /*G3E#*/ in the find
NetViewer queries like /*G3E#*/ are not working quick statements, NetViewer no longer considers them as optional
in the Viewer products parameters and executes the SQL statement as if the values were filled in,
resulting in an incorrect output recordset.

Resolution: Non-AOI queries that use nullable user parameters now


produce correct results in the Viewer products.
3. 1-9D62M9 G/Technology User is unable to attach raster file in G/Technology Desktop crashes when the user attaches a raster file.
1-9K1G09 Designer G/Technology.
Resolution: Initialized BSTR variables and LPDISPATCH/LPUNKNOWN
pointers before they are released in wrap-up section of the code.
4. 1-9D7IBX G/Technology G/Technology is crashing when user G/Technology crashes when user tries to bulk load raster images using
1-9K1G27 Designer tries to bulk load raster images Administrative > Load Images.

Resolution: Initialize BSTR variables and LPDISPATCH/LPUNKNOWN


pointers before they are released in wrap-up section of the code.
5. 1-98XB47 G/Technology Cannot tab to populate FRC on Feature Pressing the tab key does not refresh the attributes when moving from
Designer Explorer Cable Sections tab one column to the next column.

Resolution: The Cable Sections control has been changed to process


picklist selections immediately. This forces any configured functional
interfaces to fire immediately, which allows other attributes that might
have been changed by the functional interface to be updated and
immediately displayed.
6. 1-9BTJ5D G/Technology Selection of multiple plot redlines takes When multiple plot redlines are selected, re-rendering takes progressively
Designer too long to render longer based on the number of selected elements. If the user adds
another redline to the select set via ctrl-click, the handles for all
previously selected redlines are redrawn before adding the new one. If a

31
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.12004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


group of redlines is moved, all of the handles are redrawn individually in
the new location; for large groups, this starts to impede productivity.

Resolution: Improved performance of selecting single, multiple, and


grouped plot redlines.
7. 1-9FLLLX G/Technology WMS Parent ownership establishing Ownership is being set after placing a feature close to another feature.
Designer even if dialog is dismissed using red X. These features are defined to have ownership even though the user has
selected to not set ownership between those features.

For example, work points and service segments are defined in metadata
to have ownership. The work point is defined as the SOURCEFNO and the
service segment is defined as the OWNERFNO with
G3E_ENFORCEMENT=1. When placing a gas service segment close to a
work point, the ownership is set even though the user has selected to not
set ownership between the two features. This is a problem because the
work point may actually have ownership to another feature, not the
feature being placed closed to it.

Resolution: Added the ability to exclude features from forming interior


ownership relationships if the user has already been prompted and
responded via end points as well as allowing the user to be prompted for
these additional interior features to be added.
8. 1-75J8L1 G/Technology Remove unused queries does not work The setting RemoveUnusedQueries = 1 in G3E_GENERALPARAMETER
1-9FMXYR Designer for traces reduces memory consumption. This works for queries but not traces.
Traces are still listed in the Analysis > Queries dialog box tree after
removing them from the legend.

Resolution: PGTCtls.drx relocalized to include localization of newly added


string. If a trace is no longer referenced, it will be removed from the list
of queries under Analysis > Queries if
G3E_GENERALPARAMETER.RemovedUnusedQueries = 1.
9. 1-75LPE9 G/Technology AttachMemLimit registry entry missing The AttachMemLimit key should be in the registry when NetViewer is
1-9FMY1J NetViewer on a NetViewer machine. installed. But, users could not find this registry entry in any of the
machines (Client or Server).
32
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.12004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce

Resolution: New Viewer registry key AttachMemLimit is added to registry


from setup.
10. 1-7FQS1T G/Technology Snapshot of Map Window does not Snapshots of map windows cannot be pasted to all applications.
1-9FMY6T Designer work with all applications Pasting to Microsoft Paint works well, pasting to Microsoft Wordpad
displays an empty image.

Resolution: The problem is resolved.


11. 1-7HI2GL G/Technology Missing build number in About dialog The about dialog does not display the G/Technology build number.
1-9FMYEV Designer
Resolution: Increase version text box size in HelpAbout dialog in the
German and French localized G3E.DRX files.
12. 1-7XUJQB G/Technology Update GDOGML and Update GDOGML and GMWMSRasterEngine to latest version from
1-8FEFV4 Designer GMWMSRasterEngine to latest version GeoMedia.
from GeoMedia.
Resolution: These components have been updated.
13. 1-9FLLM7 G/Technology In NetViewer Map Server leaks memory In NetViewer Map Server leaks memory around ~4 MB to 5 MB per WMS
1-9BZ5TH NetViewer around ~4 MB to 5 MB per WMS connection per zoom/pan operation.
connection per zoom/pan operation
Resolution: Fixed the above memory leaks by correctly releasing the
pointers and freeing the BSTR objects. Now the starting memory footprint
of the Map Server is around 130 MB and no noticeable memory leaks are
seen. These fixes also helped the desktop by eliminating memory leak of
around 1.5 MB per pan/zoom operations.
14. 1-8ZQBUL G/Technology Z Value Corruption G/Technology is allowing users to enter extreme Z values. This corrupts
1-9FLLPT Administrator the DDC when it is published and causes the value to spread to other
features as things are snapped to each other.

Resolution: 1) In G/Technology, the Start, End, and Origin points of an arc


are supposed to all have the same Z value. G/Technology now better
enforces this and also keeps those Z values within range.
2) When an attempt is made to pick up an out of range Z value, the
default Z value specified in G3E_GENERALPARAMETER is used instead.

33
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.12004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


15. 1-960N7L G/Technology While the alternate component is In a model where geographic and alternate components are configured
1-9FLLIB Designer placed silently, a ghost appearance of for each feature, the component placement of a feature has been
geographic component displays configured with custom interactive and silent placement techniques.
Geographic components are configured with Interactive placement and
alternate components are configured with silent placement techniques.
After placing the geographic component and while the alternate
component is placed using the silent technique, a ghost appearance of the
geographic component displays in the alternate window. Upon saving this
feature, the ghost of the geographic component disappears.

Resolution: G/Technology handles display of alternate and geographic


components separately during placement of alternate components.
16. 1-9B50QZ G/Technology G/Technology crashing when the .dwg When the provided .dwg file is attached using Attach > Vector Data,
1-9FLLI1 Designer file is attached. G/Technology crashes with the "stopped working" message.

Resolution: Fixed the problem so that if the XREF file does not exist, it is
detached before attaching the file in-memory.
17. 1-9DGIA4 G/Technology Remove "," from line weight resource In a French environment, using the "." for the decimal separator instead
1-9DGTDP Analyst strings in French PMiscCtl.drx of "," causes line weights to be 1000 time bigger than they should have
been.

Resolution: Remove the decimal separator and made the value a whole
number.
18. 1-9CMI41 G/Technology Feature Allocation produces 'Key is not The Feature Allocation control uses the G3E_FID of a feature for the
Designer unique in collection' when populating unique key when added to the Route tree view. If the allocation rule
the route tree view. produces duplicate allocation candidates, such as a Fiber Inner Duct that
is contained in multiple Fiber Ducts, an error will occur during population
of the Route tree view. The control uses the G3E_FID of a feature for the
node key. If the feature exists more than once in the tree view then the
error 'Key is not unique in collection' will occur and the route tree view
will not complete population. The key generated for each node needs to
consider that the FID may not be unique. The control also needs to
consider this when requesting node labels using the label service since the

34
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.12004
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


returned array of label strings will not contain labels for duplicate key
objects.

Resolution: The control tolerates allocation candidates with multiple


route owners.
19. 1-9CR9JP G/Technology If the ModLog is out of sync with the If the ModLog is out of sync with the MapFile's component view, memory
Analyst MapFile's component view, there are could become corrupted, or memory could be leaked. There is an
memory issues. additional very small memory leak when the ModLog is out of sync with
the MapFiles. This should not happen if users maintain their data model
correctly.

Resolution: Even if the ModificationLog is out of sync with the DDCs, the
product will not crash or leak memory.
20. 1-9CRFJT G/Technology Eliminate desktop Help files from Eliminate desktop Help files from language folders for MobileViewer-only
MobileViewer language folders for MobileViewer-only setup.
setup.
Resolution: Desktop Help files are removed as requested.

35
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


1. 1-98S797 G/Technology Simple Query issue If users start a simple attribute query and launch a request that does not
Designer return anything (e.g. because of a wrong value in the search criteria), the
query fails with an error message on the next try.

Resolution: Re-executing simple queries no longer cause Oracle errors.


2. 1-9DJPLE G/Technology For an IGTCustomCommandModeless with For an IGTCustomCommandModeless with
Administrator G3E_CUSTOMCOMMAND.G3E_COMMANDCLASS G3E_CUSTOMCOMMAND.G3E_COMMANDCLASS value 0 or 1, the Property
value 0 or 1, the Property C CanTerminate is not fired. It works with
G3E_CUSTOMCOMMAND.G3E_COMMANDCLASS value 4 and 6.

When the user launches a modeless custom command, an instance of the


command is created. If he clicks anew on the same modeless custom
command before the first instance is terminated, G/Technology terminates
the first one before starting the second one.

Resolution: The modeless custom command behavior has been


restored to match 10.1 SP3 and earlier versions. If a modeless custom
command is clicked a second (or subsequent) time, the command will
simply remain active. No methods will be called. No new command
instance will be created
3. 1-9JEUML G/Technology Optional parameters in attribute queries like When optional parameters are defined using a mark /*G3E#*/ in the find
NetViewer /*G3E#*/ are not working in the Viewer quick statements, NetViewer is no longer considering them as optional
products. parameters and executes the SQL statement as if the values were filled in,
resulting into incorrect output recordset.

Resolution: Non-AOI queries that use nullable user parameters now produce
correct results in the viewers.

36
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


4. 1-9JVC5H G/Technology When attaching a MicroStation file, A MicroStation DGN containing point symbols and lines with custom line styles
MobileViewer MobileViewer goes into infinite loop while is attached in MobileViewer. The gt.ini file has been updated to point to the
G/Designer crashes font.rsc and line style RSC files used to create the DGN. When the file is
attached, the Viewer products goes into an infinite loop, killing the mapserver
process and the client had to be killed. When attempted the same workflow in
Designer/Analyst, the application is crashing.

Resolution: The issue is resolved.

5. 1-7CYYHR G/Technology Unable to display the output page for other The user is unable to display the output for other commands when more than
1-9ACLUD NetViewer commands defined in a single toolstrip one Scriptshortcut commands like ScriptshortcutButton or
ScriptshortcutTextBox is defined in a single toolstrip. In a custom toolstrip, if a
user defines two commands of the same type like scriptshortcutbutton or
scriptshortcuttextbox, if the second command is invoked no output will be
displayed.

Resolution: The toolstrip can have more than one scriptshortcut button and
works based on the command type attribute.
6. 1-93I704 G/Technology Cannot delete geometry components where A user cannot delete a graphic component using the Edit Tool for feature
1-9ACLU3 Designer G3E_ALTERNATEGEOORDINAL <> 0 components set to G3E_FEATURECOMPONENT.G3E_ALTERNATEGEOORDINAL
<> 0 and G3E_FEATURECOMPONENT.G3E_ALTERNATEGEOGRAPHIC = 1 using
legends with G3E_LEGEND.G3E_ALTERNATEGEOORDINAL <> 0 defined in
metadata.

Resolution: The AddSelectedItems method properly handles alternate


components.
7. 1-94HLYD G/Technology NetViewer opens the Analysis command pane NetViewer opens the Analysis command pane for the first time while
1-9ACM57 NetViewer while executing commands on the custom executing commands on the custom toolbar. If the pane is closed after clicking
toolbar the X button, the pane does not open for any command clicks on the toolbar.

Resolution: The toolstrip can have more than one scriptshortcut button, and
works based on the command type attribute.

37
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


8. 1-997ZQP G/Technology Add Metadata to G3E_LINESTYLE to carry an Add Metadata to G3E_LINESTYLE to carry an override for the line weight and
Designer override for the line weight use this information during export to CAD for MicroStation V7.

Resolution: Added a new column


G3E_LINESTYLE.G3E_MICROSTATIONOVERRIDEWEIGHT so an administrator
can key in a MicroStation line weight value between 0-31 to be displayed in
the DGN file.
9. 1-91FAFY G/Technology Features are being exported with the same Y- Features are being exported with the same Y-values when using MapInfo
NetExport values using MapInfo (NetExport Format Type).
Server
Resolution: The export logic picks the right unit based on the
StorageToProjectionScale defined in the coordinate system information.
10. 1-98PPJG G/Technology Using API function Using API function _mapViewService.DisplayAnalysisResults generates an
NetViewer _mapViewService.DisplayAnalysisResults error.
generates an error
Resolution: Generated the correct URL when using the
_mapViewService.DisplayAnalysisResults overloaded API method without the
MapDisplayOption argument.
11. 1-98WDQN G/Technology SaveAsAutoCAD takes several minutes to create Users have customized functionality that allows them to place multiple plot
Designer output AutoCAD file boundaries in one plot window. Once the plot boundaries are placed, the
user has the option to save the plot window to different file formats
(AutoCAD, MicroStation, etc.). The SaveAsAutoCAD is taking 40-45 minutes
while the save to MicroStation only takes a few seconds using the same plot
window.

Resolution: Improved the SaveAsAutoCAD performance.


12. 1-98HHRR G/Technology Line styles not applied to redlines when Exporting a migrated plot with redlines to MicroStation results in the correct
Designer exporting to MicroStation from a migrated plot line styles not being applied to redlines.

Resolution: AppendPlotToDGN and the ExportToDGN display correct line


styles for redlines.
13. 1-985IW9 G/Technology French localization Development to include localized French resources in G/Technology 10.2 SP2
Designer build.

38
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: 10.2 SP2 is localized for French.
14. 1-985IYP G/Technology German localization Development to include localized German resources in G/Technology 10.2 SP2
Designer build.

Resolution: 10.2 SP2 is localized for German.


15. 1-98PCY3 G/Technology Unable to invoke database upgrade wizard on a Unable to invoke database upgrade wizard on a clean machine. Unable to
Administrator clean machine. invoke G/Technology on a clean machine.

Resolution: Delivered MFC90*.msm files reset to use version on 64-bit


machine. These are different between the XP and Win7 64-bit installation of
InstallShield 2012.
16. 1-79Y35H G/Technology WMS data missing with rotated plots Some rotated plots do not include WMS data. Users have reproduced the
1-98IY1Z NetPlot Server problem with both the Czech and English languages. Users are using low
resolution settings, but are still are not seeing the WMS data. If they submit a
plot with no rotation at the same resolution, then the WMS data displays in
the plot.

Resolution: WMS data displays and prints properly in rotated map frames.
17. 1-7V0WQ0 G/Technology Fill color for area features change at different At different zoom levels, the fill color for areas (buildings) are changing in both
1-98IY65 NetViewer zoom levels NetViewer and MobileViewer.

Resolution: Fixed the problem by collecting all the highly used colors while
creating the PNG file.
18. 1-88GH3Y G/Technology Degradation of printing using export to Raster files with 6 overviews (created with ISRU tools) cause problems with
1-98IZSR Designer PDF/plotting. plotting in Designer/Analyst. After plotting/export to PDF several times in a
row without exiting G/Technology, there is a degradation of the quality of the
printing. This is also reproduced with Export to PDF after attaching the
rasters. This problem only occurs on clients with Windows 7 32-bit OS.

Resolution: The software clears the raster cache with each print or export to
PDF.
19. 1-8L529H G/Technology LD Pro Start error The existing job/design area JOBNO178351: selecting Analysis > Start LD Pro
1-8VKNS5 Designer throws errors.

39
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: Made the changes to access the updated software that allows the
objects that the software is trying to create to be resolved.
20. 1-8LWNBL G/Technology Issue with Copy Parallel extending from Copy Parallel is extending new lines from unexpected endpoints. The Copy
1-98J01D Administrator unexpected endpoints PTarallel extension point depends on the placement of the original features,
but there seems to be a different case for every combination. The example is
two cables lined up. If the cables are in sequence (endpoints line up 1-2,1-2)
or mirrored (1-2,2-1) or if they are perpendicular, the point of extension for
Copy Parallel is different. As long as the endpoints are in sequence, no matter
the direction (1-2,1-2), the product behaves as expected.

Resolution: Copy Parallel Construction Aid is corrected to extend dynamics


(from already digitized points) to the end of the first selected geometry and to
continue digitizing from the last point of the latest selected geometry.
21. 1-8OV6IQ G/Technology Unable to resize Ownership, QuickPick, Break Users have found cases where the pop-up dialogs for break, ownership, and
1-98IY83 Designer pop-up dialogs PickQuick are not resizable when the label formats that populate those dialogs
are small. For example, the label format for Circuit is two characters.

Resolution: Modified the PickQuick dialog to show the icons (toolbar options)
if the operation is multi select even if the labels are too small.
22. 1-8PZXZS G/Technology Alternate component ghosting issue After placing features using a custom command, moving these features, then
1-98IZXR Designer placing new features with same custom command, the label and extraneous
components are viewed in the alternate component map window.

Resolution: The ghost appearance of alternate components is not observed


on the map window.
23. 1-8TPFJZ G/Technology Restricting access to a job through metadata Restricting access to a job to a single user through
1-98IXYD Designer causes errors with opening a workspace that G3E_JOBDEFINITION.G3E_ALLOWCONCURRENTJOBACCESS causes errors with
opens a job opening a workspace that activates a job which is currently in use. This works
correctly when G/Technology is already open and users try to open a job that
is currently in use, but does not work if users open a workspace that activates
a job that is currently in use.

Resolution: G/Technology returns the proper error message.

40
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


24. 1-8U6HYG G/Technology Partial Post does not transition state Partial Post does not trigger the transition to the INS state unless users pan
1-98IY29 Designer graphics off and then on screen or refresh graphics.

Resolution: After Partial Post, the map window correctly updates the feature
based on its state.
25. 1-8UKA9K G/Technology Attaching a MicroStation design file takes a long A user is trying to attach a CAD file as a backdrop from a network location
1-98J03L Designer time to process. using a UNC path. The Process Monitor shows G/Technology is attempting to
open all of the files in the same folder as the file being requested.

Resolution: The problem is resolved. Loading the file after browsing is much
faster.
26. 1-8V6C2F G/Technology Copy data check box missing on Edit Job dialog. When users select a work management job (contains -1) and select a revision,
1-98IZXH Designer the New Job user dialog box does not show the Copy Data check box as
described in Help.

Resolution: The Copy Data check box was out of visibility in the form.
Modified the form to show the check box.
27. 1-8VFDLQ G/Technology Dataimport.exe not creating angle information in Users have configured a CAD secondary connection. The secondary data will
1-98IXY3 Designer SQL Loader files be imported into G/Technology. However, users are finding that the angles for
the labels are not being written into the SQL loader files generated by
dataimport.exe.

Resolution: The angular information is considered and imported to the DAT


file for the text labels.
28. 1-8VKUBV G/Technology Drawing queries or traces causes memory to be Any kind of drawing operation (for example, pan, zoom, fit) while displaying
1-98J0KT Analyst used up queries or traces will cause memory usage to grow.

Resolution: The use of memory is much more reasonable now when drawing
queries and traces.
29. 1-8WBKPP G/Technology IGTDataContext.MetadataRecordset IGTDataContext.MetadataRecordset("G3E_ATTRIBUTEINFO_OPTABLE",
1-98J0QD Administrator ("G3E_ATTRIBUTEINFO_OPTABLE", "G3E_ANO='300006'") has an error when there are single quotes in the filter.
"G3E_ANO='300006'") throws error.
Resolution: Removed the quotes from around the G3E_ANO value.

41
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


30. 1-8WMB0X G/Technology Display Status for the Traces node is not checked After executing a trace in the G/Technology desktop, the Display Status for the
1-98J0GN Designer ON. parent Traces node is not checked ON. It should be checked ON.

Resolution: The software properly sets the Display Status checkbox of the
Traces node when adding a trace to the Display Control.
31. 1-8WPQM3 G/Technology Legend list is not displaying when configuring When trying to add a row after deleting the existing row, the legend list does
1-98J0U9 NetViewer warm startup for the second time not display.

Resolution: The fix was to remove the cache of connections and to reconnect
for each unique configuration and username pair. Most customers use only
one configuration for all of their NetViewer users, so this change will have no
negative performance impact on them.
32. 1-8WSHRR G/Technology Extract Utility crashes with PElecAna1.dll error When executing ExtractUtility.exe the exe crashes reporting:
1-98J0SB Designer Faulting application name: ExtractUtility.exe, version: 10.1.3.27001, time
stamp: 0x52da1ac6
Faulting module name: PElecAna1.dll_unloaded, version: 0.0.0.0, time stamp:
0x52da1255
Exception code: 0xc0000005
Fault offset: 0x0e3a413d
Faulting process id: 0xc28
Faulting application start time: 0x01cf244fa5f19903
Faulting application path: C:\Program Files
(x86)\Intergraph\GTechnology\Program\ExtractUtility.exe
Faulting module path: PElecAna1.dll
Report Id: e8d57aa1-9042-11e3-8cf1-0050568647c0

in the application event viewer log.

Resolution: Modified the electric analysis component to process all the circuits
without an error.
33. 1-8WW1DV G/Technology Getting an error while creating WMS connection Users see an error while creating WMS connection.
1-8ZFONF Administrator
Resolution: Ensured that an exception would not be thrown if a parent
element was not found with the same attribute.
42
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


34. 1-8XMX4I G/Technology Getting error when running Duct Occupancy Users are getting the following error when trying to generate a Duct
1-98J0OF Administrator report. Occupancy Report:

"Automation error. The object invoked has disconnected from its clients."

The existing “Duct Occupancy Report” uses a VB6 Report Interface


(PRIface.DuctOccupancyReport)

Resolution: The software now supports many-ownership relationship rules


where feature types could be related to themselves.
35. 1-8XRMAW G/Technology NetExport failing when running in batch Users have provided code to run NetExport in batch. The memory for
1-98J0MH NetExport GNExpSvr.exe keeps growing during the batch process, but the memory never
Server recycles. After all the memory on the machine is allocated to GNExpSvr.exe,
the executable crashes with an error message in the EventLog.

Resolution: Few improvements and fixes were done to plug this memory leak
with each NetExport request.
36. 1-8YSBML G/Technology Posting timing out G/Technology has been configured to use MSMQ for posting features. MSMQ
1-98J07H Designer has been configured to use Queues and triggers for posting. The posting is
immediate when posting 1-4 features, but if more features need to be posted
(25-30), then the post times out with error message:

A timeout has occurred waiting for a response from a message. No features


were posted.

Resolution: G/Technology Queue processing Service (GTDCom.exe) was


reading messages from MSMQ synchronously until a response message
arrived which then triggered a receive event handled by GWork.JobHelper
object hosted inside the software. If the response was received immediately
(less than 4 minutes) the fired received event was correctly handled inside
GWork.JobHelper class. Due to cross process communication across process
boundaries for an object dimmed with events, there are issues after a certain
interval and the object is not left in a good state resulting in the event not

43
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


being handled inside G/Technology, even though it was correctly raised from
GTDcom.exe

Following are the cases depending on the value of


G3E_MESSAGE_OPTABLE.G3E_TIMEOUT field in metadata:
1) NULL – G/Technology waits indefinitely for the response message to arrive.
2) 0 – G/Technology continues with the posting of features without waiting
for the response message.
3) Value greater than 0 - G/Technology process waits until the specified time
out value for the response message to arrive.
37. 1-8YSR8V G/Technology Need to produce a better message when The limit is a bit above 15K.
1-98J07R Designer software runs out of the limit of dimming ADO
Record sets with events. The message should be:

Retrieval of the component recordset (<insert CNO value> on

Resolution: The error is no longer misleading. The message is: Retrieval of


the recordset from component %1$s in table %2$s failed.
38. 1-90X0AO G/Technology Passing a PATH to GTechPDFPrinter is causing In the past, users could customize the XML request sent to NetPlot and
1-98J0A9 NetPlot Server overflow errors in NetPlot include a PATH plus file name for the GTechPDFPrinter.

For example,

<GTechPDFPrinter>
<OutputFilename>C:\PDF-OUTPUT\500092941.PDF</OutputFilename>
<Overwrite>true</Overwrite>
<Resolution>72</Resolution>
</GTechPDFPrinter>

Users use the same information above and see an error :


Overflow
Plot produced may be incorrect.

44
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: Changed code such that if full path is specified in GTechPDFPrinter
OutputFilename tag, the output file is generated in the specified path and
both Tempfolder and Webfolder are ignorned.
39. 1-92F4PL G/Technology Add feature that caused a break to the Add the feature (IGTKeyObject) that caused a break to the
1-98J0BN Designer IGTApplication.Properties collection in IGTApplication.Properties collection so FOW can use it in an
G/Technology for FOW 1.1 IGTPostBreakLinear implementation.

Resolution: Provided a solution for FOW to get access to the feature that
caused the break.
40. 1-943S9L G/Technology API DataContext.OpenRecordset fails with Certain commands randomly fail in certain calls to the database.
1-98J0FJ Designer generic oracle messages.
Resolution: These commands no longer randomly fail.
41. 1-94NJTO G/Technology Save View to DGN not honoring legend overrides Save As DGN is not honoring legend overrides.
1-98J0IL MobileViewer
Resolution: Fixed the problem by honoring legend overrides for SaveAsDGN.
SaveAsPNG, SaveAsPDF, SaveAsAutoCAD, AttachCADFile, and AttachRaster
command requests coming from multiple clients (with different legend
overrides) to a mapserver.
42. 1-960T7Z G/Technology Problems exporting and saving plots when Problems exporting and saving plots when Graphic Overrides exist
1-98J0Y5 Designer graphic overrides exist
Resolution: The software correctly sets the node type for Temporary
Geometry while building the tree object which is used by the
GetDisplayControlNodes object and logging an error if the node type was not
found instead of defaulting to query node type.
43. 1-965F3C G/Technology Mobile increment failing The publish subset process did not properly handle reading a newer version of
1-98J11H Designer the DDC file after reading an older version of a DDC file which was the
secondary data type DDC file.

Resolution: Publishing incremental subsets works as expected.


44. 1-975A6T G/Technology Improvement for panning WMS in G/Technology Develop a solution for improving WMS rendering for multiple subsequent pan
1-98J0W7 Designer designer. operations. Suspend WMS rendering until the sequence of pan operations
ends.

45
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: A new Delay WMS refresh when panning option is available. It
allows users to control when WMS data is refreshed during pan operations. It
is On by default. The Delay interval allows users to specify how long the Pan
command waits before refreshing WMS data. The default is 1500 milliseconds
(ms) or 1.5 seconds. The valid range is 1 ms (0.001 seconds) to 10000 ms (10
seconds).
45. 1-95NEQ9 G/Technology Error on the Feature Explorer dialog tab using Error while displaying the dialog tab in the Feature Explorer for Cable Section
MobileViewer 10.1 SP1 MobileViewer with 10.2 SP2 subset tab when using 10.1 SP1 MobileViewer against a 10.2 SP2 subset.

It is displayed as a Functional Interface error,” Item cannot be found in the


collection corresponding to the requested name or ordinal.” The tab contains
no data.

Resolution: Errors are due to removal of VBA fields in 10.2 being accessed in
10.1 SP3. Created a tool to add fields back to RAW files in a published subset.
46. 1-92KQ5M G/Technology Text shifted when exporting to CAD Text is not properly positioned when exporting to AutoCAD or MicroStation.
Designer
Resolution: Fixed both the problems so that Export to AutoCAD and Export to
MicroStation positions text properly.
47. 1-92VDG5 G/Technology Some elements (ellipse and shared cell) are not When a DWG file is attached in a map window, some elements (cell and
Designer visible in attached DWG file ellipse) are not visible.

Resolution: All the elements are visible after attach.


48. 1-91QFZV G/Technology SaveAsAutoCAD fails when including both Geo- SaveAsAutoCAD fails when including both geo and detail map window
Designer Detail map window contents in plot window. contents. If users use just geo map window contents, the command works. If
users use just detail window contents, the command works.

Resolution: Improved the logic to persist the lost bookmark of frame recordset
while executing SaveAsAutoCAD method.
49. 1-94KWOK G/Technology Replace error handling results in incorrect When Replace command is run with a feature that is in an invalid state, the
Designer deletion of component data command correctly displays a message to the user but incorrectly deletes data
associated with the selected feature.

46
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: Correctly rolling back the feature's cached information when the
rollback occurs.
50. 1-939NGY G/Technology Creating a new detail window from an existing Creating a new detail window from an existing window creates a detail at an
Administrator window creates an empty window errant display scale and away from the indicated window.

Resolution: The Detail Window opened when placing a new detail indicator
was not empty. It was zoomed to the wrong location. This has been
corrected, and the new window is now zoomed to the correct location
51. 1-7N2GQH G/Technology Z -coordinate is not displayed in the exported A Z -coordinate is not displayed in the CAD/DGN file exported from NetExport.
NetExport CAD/DGN file.
Server Resolution: Fixed the problem to honor z-coordinate value for ArcView, DGN,
and DWG. FME does not support z-value for MapInfo and ArcInfo.
52. 1-8PJWHZ G/Technology Bad performance when displaying placement After starting the command, it takes about 20 seconds to show the tree with
Designer icons tree the placement icons.

Resolution: Fixed the problem so that the BMPs are loaded at a faster rate
with new feature placement command.
53. 1-91TR0J G/Technology Open Detail Window is not displaying the Open Detail Window is not displaying the complete list of details available in
Designer complete list of details available in the AOI set. the AOI set.

Resolution: The solution is to use the AOILI concept. In this case, the selected
AOI feeds the value of its location identifier. This attribute value is used to
query the component views of the detail indicator instead of using spatial
filtering. This ensures that only those detail indicators that belong to the
selected feature are listed on the Open Detail Window dialog box.
54. 1-8Y6B9N G/Technology Edit Box - Text Not Legible Edit box is presently using the current plot size font instead of a standard
Designer legible font size.

Resolution: Enhanced the functionality of Edit text box by adding an Apply


Style check box.
55. 1-94UZLR G/Technology Need to correct encryption string algorithm Users can not use the encrypted connection string retrieved from
Designer Designer/Analyst API IGTDataContext.ViewerEncryptedConnectionString for a
plot request. This function returns an encrypted version different from
NetViewer API.
47
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce

Resolution: Changed the viewer connection string to use the actual


configuration name that is passed in to the data context rather than the
parsed value from the G/Technology Designer connection string.
56. 1-90ENZC G/Technology Redline text missing in export to AutoCAD Redline text is missing when a plot is exported to AutoCAD.
Designer
Resolution: Fixed the problem by handling both new line characters '\n' and
'\r\n'
57. 1-8ZYFNL G/Technology NetExport not generating an error when NetExport is not generating an error if the ParameterValues collection is
NetExport G3E_FILTER includes a dynamic parameter that is empty and G3E_FILTER contains a dynamic parameter. This happens only
Server non-numeric when the dynamic parameter to be replaced is non-numeric. For example, if
the filter value is SWITCH_CENTRE_CLLI = '%1$s', the software assumes it to
be a valid filter and executes it on the component views even when there are
no dynamic parameter values specified, thereby resulting in no records
returned for that component view. It should have generated an error in this
scenario.

Resolution: Updated the code to display the appropriate error in this scenario.
58. 1-915JBQ G/Technology Key In Angle box mirroring symbols between 95 Workflow:
Designer and 265 degrees 1. Access New Feature > Miscellaneous > Terminal > Non-CPR.
2. Place the Terminal on a (copper connector) Splice and owned it to the
Splice.
3. Type 225 in the Key In Angle box and select OK.
4. The terminal looks like it is at 45 degree angle instead of 225.
Users observed that for some reason when they enter 95 to 265 in this box,
the result does not rotate correctly. It appears that when users enter a
number in that range for the angle, it reflects the symbol over a perpendicular
axis to the angle entered.

Resolution: Fixed the code to honor general parameters (RRALOW and


RRAHIGH).
59. 1-91GIUW G/Technology Graphic information not being exported when Users configured NetExport to use E00 (ArcInfo NetExport Format Type) in
NetExport using E00 NetExport Format Type metadata. The export is successful but there is no graphical information
Server exported.
48
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce

Resolution: Updated the code to ensure that the geometry mapping is


specified in terms of generic FME geometry attributes. At export time, FME
objects will map these generic types into the type that corresponds to the E00
format.
60. 1-92URWL G/Technology Disable translucency override for attached Disable translucency override for attached redlines because the fidelity is lost
Designer redlines because the fidelity is lost going to NetPlot or when called from the API.

Resolution: The Translucency buttons on the Display Control are now disabled
when attached redlines are selected.
61. 1-8XQJPX G/Technology Engineering Plotting API - attached redlines Redlines are printed, but in the map window redlines are not filled. They are
Designer losing fidelity - fill is not transparent in WebPlot filled in plot output.

Resolution: Redlines with transparent or hatched fill are now properly


rendered when attaching or plotting redlines.
62. 1-8W79AZ G/Technology Unable to use mixed-case passwords with the JLC Some users have a security requirement to have mixed case passwords for
Designer Monitor their Oracle usernames. In Designer/Analyst, users have found that mixed
case passwords can be used, but with JLC monitor, users have found that the
username and password are submitted in UPPER case no matter how they are
defined in Oracle.

Resolution: Modified JLCMonitor to allow the case-sensitive password to be


used and retained.
63. 1-8YBUUH G/Technology Replace feature error message needs to be For any feature that does not have a feature state (landbase features) the
Designer changed message needs be to changed from "Invalid procedure call or argument" to
"This feature does not participate in the Replace Function"

Resolution: Add validation of G3E_FEATURE.G3E_REPLACE prior to validating


the replace filter field in G3E_WORKMGMT. Now, the normal error that the
feature cannot be replaced is displayed if the replace filter defined in
G3E_WORKMGMT does not exist in the feature.
64. 1-8E27N0 G/Technology Context Sensitive Help Non-modal custom Context Sensitive Help non-modal custom command also opens product help.
Designer command also opens product help

49
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.10001, .10002, .11001 - .11005
 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is not required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: Made modification to product code to only display the requested
custom Help topic.
65. 1-925O0M G/Technology Put better error handling in to the Set Detail Add better error handling to the Set Detail Properties dialog.
Designer Properties dialog.
Resolution: After any unexpected errors on the Set Detail Properties dialog,
the product responds as expected.
66. 1-8XAUOB G/Technology Update NetViewer/MobileViewer to correctly Update NetViewer/MobileViewer to correctly process union queries.
NetViewer process union queries
Resolution: Attribute queries with unions now work in NetViewer.
67. 1-8WS3JA G/Technology Manhole detail polygon induces invalid geometry A user can place a manhole polygon via Edit Feature from the Geographic
Designer and invalid blob error. Component graphic as a line with just two points instead of a polygon.
G/Technology displays messages. If you save, the graphics are deleted, but it is
an invalid geometry.

Resolution: This placement technique now checks the rectangle placement to


ensure that it is valid. If it is not, a message is still displayed but the placement
of the second point can resume.

50
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


1. 1-7TJDWJ G/Technology Need to document the version of MicroStation The online help only states MicroStation v8 for the version of
Designer supported with secondary data. MicroStation supported for secondary data publish. The helps needs to
be explicit on the exact version supported.

Resolution: Added a new topic called MicroStation Element Types


Support to Administrators Guide to G/Technology.
2. 1-90T9O5 G/Technology Exported Redline text height and origin.y varies When redlines text is exported from a plot window, then the height and
Designer Y origin value varies in the exported V7 DGN file.

Resolution: Optimized the code to give accurate height and Y origin


values.
3. 1-8WRTXE G/Technology Always open new detail map window is not Users have a Copper Cable that is entirely in detail; four details to be
Designer opening all details. exact. The Cable is in the following details (beginning to end):
Xx1305d04u
Xx1305d05u
Xx13-5c01u
Xx1305c02u
Set the AOI to State > Community
Run a Find > Include detail – Always open new detail map window >
Quick Reference > Criteria > Cable >
Cable ID: 044
Low: 1
High: 100
Select OK.
It opens the first two details, but not the third and fourth detail
windows.

Resolution: The command now opens all of the detail windows as


expected.
4. 1-8XBIPB G/Technology Publish Subset - "Delete Subset" and "Archive Publish Subset "Delete an existing subset" option is receiving a
MobileViewer Subset" are getting permission denied Permission Denied error in some cases. When this happens, everything
is deleted from the subset except the raster and hyperlinks folder and
files/folder under it. Note that this problem does not occur using older
51
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


subsets that do not have the new raster and hyperlinks multilayered
folder structure.

Resolution: Subset folder will be deleted without error message.


5. 1-8GJNHB G/Technology Mobile Viewer Performance issue - Loading Loading imagery is too slow and while zooming out it frequently times
MobileViewer imagery is too slow out when the raster file is located on an UNC share which is stored in
the database attribute, and the MobileViewer device is on the network
6. 1-8X0XN9 G/Technology MobileViewer is trying to access raster files over With the changes to the file locator for raster files using the new
MobileViewer the network in some cases. multilayered folder structure, MobileViewer should not attempt to
access raster files across the network. If the file is not found in the
expected location in the raster-hyperlinks folder of the installed subset,
as a last resort it is looking at the path in the data and if that path is over
the network, it is looking there.

Resolution: MobileViewer is looking raster file only at the installed


subset folder.
7. 1-8XHBAY G/Technology MobileViewer should be using installed subset only Currently, If an entry for raster files or other paths exists in the Field
MobileViewer to locate raster files, not Field FileUNCPaths.xml FILEUNCPATHS.xml, this will be used to locate the raster files.

Resolution: MobileViewer is looking at the raster file under raster-


hyperlinks folder within the installed subset.
8. 1-8WK61T G/Technology Feature colors not correct on export to When doing an export to MicroStation from the G/Comms records
Designer MicroStation from records environment, the feature colors are not always being reproduced
correctly.
Resolution: Fixed the problem so that the color palette from the seed
file is used during export to MicroStation and hence the correct colors
are displayed per the seed file's color palette.
9. 1-8WDPO9 G/Technology Custom line style not being applied during Save As Custom line style is not being applied during Save As AutoCAD.
Designer AutoCAD
Resolution: Updated the Teigha library code to handle the comma (",")
case correctly.

52
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


10. 1-8WFE9N G/Technology Issues in Reassign Details command that have The Reassign Details command does not work when Detail Detail
Designer surfaced because of recent Detail-in-Detail work Indicators are present in the data model. The Find button is finding
orphaned details that are not orphans.

Resolution: The command has been modified to correct the algorithm


for finding orphaned details.
11. 1-8UW9M5 G/Technology Issues when feature has a Geo Detail Indicator When a feature has a Geo Detail Indicator component AND a Detail,
Designer component AND a Detail Detail Indicator Detail Indicator component, there are a number of unexpected
component. behaviors.

Resolution: 1) The Detail relationship software expected that for a


particular G3E_FNO in G3E_DETAILS_OPTABLE there would be only one
value for G3E_GEOGRAPHICCNO. When a feature has two indicator
components, this is not a valid assumption. The Detail relationship has
been modified to be aware that a feature might have more than one
detail referencing component (usually a geographic and a detail).

2) The command was only displaying the details indicated by one of the
two detail referencing components of the Drawing Indicator feature. The
command has been modified to be aware that there might be more than
one detail-indicating component (geographic and detail) in a feature.
12. 1-8VZTXS G/Technology Open Detail Window is not displaying the complete Open Detail Window > Browse for details within an AOI does not return
Designer list of detail available in the AOI set. all the detail windows.

Resolution: The command was only displaying the details indicated by


one of the two detail referencing components of the Drawing Indicator
feature. The command has been modified to be aware that there might
be more than one detail-indicating component (geographic and detail)
in a feature.
13. 1-8WSGT3 Application Error message is displayed when opening the The following error message is displayed when connecting to NetExport:
G/NetExport NetExport sample web page The sample checks NetExport Client control version on the first usage
and therefore you must enable the 'Initialize and script ActiveX Controls

53
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


not marked as safe' option for the security zone in which you are
viewing the page and refresh the page.

Resolution: Install desktop along with NetExport.


14. 1-8VYXQ3 G/Technology Incorrect integration of Incorrect integration of MG3ECreateOptimizedTables.sql.
Administrator MG3ECreateOptimizedTables.sql Mixed up changes in G3E_DIALOGATTRIBUTES_PKG between 10.1 SP3
and 10.2 SP1.

Resolution: Integration problem from 10.1 SP3 to 10.2 SP1.


vc2Select array created correctly and procedure does not fail.
15. 1-8WMV6H G/Technology Stabilization Unable to fit the currently viewed jobs using Fit the selected job(s) in
NetViewer “JobApostropheSupportInNetViewer101” test NetViewer under Jobs menu.
failure.
Resolution: In the FitJob() method of Map.aspx, the AppendQuery
method was not appending the results since
oMapRequest.GenerateMap = false. Changing the value to true solved
the issue.
16. 1-8WPQO1 G/Technology ODTR trace is failing with an error message. ODTR is failing with an error message: "ActiveX component can’t create
MobileViewer object | An error occurred while executing the trace. Please contact
your System Administrator for assistance."

Resolution: Put delivery of DotNetManager.dll, DotNetManager.tlb,


DotNetEventHelper.dll, ad ODTR.dll back into GTechMaxCore.ism and
remove from GTechDesktopCore.ism
17. 1-8W1OX3 G/Technology Publish Subset not working as expected PublishSubsetService.exe is hanging. Users are unable to publish a
MobileViewer subset.

Resolution: The queries were updated to use B$ tables.


18. 1-8W1UP5 G/Technology Unable to create a Secondary database connection. Secondary Connection types are not displayed in the “Database
1-8W3MOL Administrator Connection Wizard”.

Resolution: Updated GTechMaxCore.ism to include the external


registration files for each secondary data component.
54
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


19. 1-8VHVL3 G/Technology Unable to export map window content to An error occurred when exporting the Conductor and Pole features
1-8WE55V NetExport Server MicroStation (.dgn) format placed in a Design Area to MicroStation format (both V7 and V8).

Resolution: Added fix to handle carriage returns in addition to newlines


in the text.
20. 1-8VE7BQ G/Technology Disable symbology overrides for attached redlines The Symbology button should be disabled when an attached redlines
Designer because they do not retain fidelity of hatching and node is selected.
fill
Resolution: The Symbology button does not enable when an attached
redlines node is selected.
21. 1-6KF1HE G/Technology WMS map disappears when the scale is less than Coordinate transformations are sometimes poor when relying on a
1-8VJN7R Designer 9400 WMS site's full range (BoundingBox) of coverage for a given EPSG code.
This causes WMS images to be distorted or to not display at certain
display scales.

Resolution: Added support for a new INI parameter called [WMS Area
of Interest], which gives users control over the range of data that is
requested from a WMS site.
22. 1-7QB9KM G/Technology Displaying raster images crashes G/Technology Displaying raster images crashes G/Technology when GeoMedia is
1-8VKO4X Designer when GeoMedia installed installed.

Resolution: Commented the code portion that creates


GeoMedia.RasterInfoBufferService in G/Technology.
23. 1-6QL65G G/Technology NetViewer opens the Analysis command page NetViewer opens the Analysis command page frame while executing a
1-8VKNR1 NetViewer frame while executing a toolstrip custom command toolstrip custom command.

Resolution: The page frames display as expected.


24. 1-7B9RUE G/Technology G3EVALIDATE package fails while validating a G3EVALIDATE package fails while validating a feature with a VARCHAR2
1-8VKNWV Administrator feature with a VARCHAR2 traversable attribute traversable attribute.

Resolution: Look at the column type instead of the data that was being
stored in it.

55
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


25. 1-7L1WDQ G/Technology Bringing a Fiber Report trace through to the plot Bringing a Fiber Report trace through to the plot window creates
1-8VKYHP Designer window creates corrupt PDFs corrupt PDFs.

Resolution: When constructing the layer hierarchy that is embedded


into the generated PDF file, the special characters, [ ] and ( ), are
substituted with another character in each query/trace name, plot
window map frame name, and metadata layer name. The substitutions
appear in the generated PDF file only. Query/trace names, plot window
map frame names, and metadata layer names are not changed.

The following character substitutions are performed:


[ is substituted with <
] is substituted with >
( is substituted with {
) is substituted with }
26. 1-8DVCYN G/Technology Performance of metadata publish takes 25% longer Performance of metadata publish takes 25% more time in comparison
1-8VKNOJ Administrator in comparison to version 10.1 SP3 with version 10.1 SP3.

Resolution: The publish process does not take more time to execute
G3E_DIALOGATTRIBUTES_PKG.CREATEOPTIMIZEDTABLE.
27. 1-8O2N4J G/Technology Hover and snap are not working properly for Steps to reproduce:
1-8VKNO9 NetExport Server multiline text in MicroStation file from NetExport 1. Configure a feature having multiline text label for NetExport, E.g.
Pole label, and set alignment for it to right top.
2. Export to MicroStation from NetExport.
3. Open the MicroStation file then zoom to multiline label for which
alignment was set to right top.
4. Observe that when users hover over right half of text, it is not
highlighted though text will be highlighted when users hover on left
half and also when they snap on it. Snapping is done on center of
text. There is miscalculation in the length of the text.
5. The same scenario is observed when text alignment is set to center
top for a label in G/Technology.

56
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: Added functionality for writing multiline text to the .dgn file
(MicroStation format) as it looks in G/Technology, thereby preserving
the justification and avoiding the breaking of multiline text into single-
line text features.
28. 1-8QN5Q0 G/Technology NetViewer map services not stable Since upgrade to 10.02.0001.06006, the NetViewer Server is not stable.
1-8VJNB3 NetViewer After a while all map server services seem to hang.

Resolution: The map request initialization code was changed so that it


attempts to move a user’s previous query results only when required.
29. 31744_U G/Technology Highlight of components if an additional Highlight of components if an additional component is added --
Designer component is added If a feature is placed with some different graphic components that are
visible in different legends and an additional graphic component is
added to this feature using New Component, all already placed
components are displayed during the placement even if there is no
entry in the legend of the actual map window for some of the
components (e.g. overview components).

Resolution: Components that are not part of Active legend do not


display and the behavior is similar to Feature Explorer (add new
component via Geometry tab).
30. 1-8K9V0E G/Technology G/Technology fails when multiple plot units Users observed that when submitting the same plot request several
NetPlot Server defined in Netplotservice.exe.config times, G/Technology fails with the following error message :
Status = FAILURE
Errors:
Unable to open Workspace. The username, password or configuration
may be incorrect. Error opening the workspace

If users have just one plot unit defined in the Netplotservice.exe.config


file, they can send the same plot request several times without failure.

Resolution: This is a documentation issue. G/Technology updated the


NetPlotService.exe.config File administrative help topic and the Release
Notes.
57
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


31. 1-8VBMM7 G/Technology The bat file InstallUltiDvCassini.bat needs to quote The bat file InstallUltiDvCassini.bat needs to quote the path for
MobileViewer the path for gacutil.exe otherwise it fails to gacutil.exe, otherwise it fails to register the
UltiDevCassiniHttpRequestProcessor2.0.dll when installing Cassini.

Resolution: Added the quote as required.


32. 1-8UJ4EV G/Technology Sorting Complements on dialog tabs not working G3E_DIALOGTAB.G3E_ORDERBYKEY metadata is populated properly,
MobileViewer properly but the Complements tab is not sorted.

Resolution: The software now applies the


G3E_DIALOGTAB.G3E_ORDERBYKEY metadata to non-component tables
(for example, foreign key and domain tables) when a dialog tab consists
of traversable attributes only.
33. 1-8PWX3N G/Technology User-defined line styles DGN are not displayed A DGN user-defined line style (UDLS) which is a compound of "Internal"
Designer properly line and Point components is not displayed properly when the style is
attached to G/Technology using the Attach Vector Data command. The
“Internal” line style is missing in a G/Technology map window. When
the user defines a line style which is compounded of Stroke and Point,
the style is displayed properly in G/Technology.

Resolution: Fixed the problem so that all the UDLS appear correctly on
attaching the DGN file.
34. 1-8Q0OM1 G/Technology Detail Indicators that are Detail Components are Detail Indicators that are Detail Components are not coded correctly
Designer not coded correctly throughout the product. throughout the product. A Detail Component should always have a
G3E_DETAILID field. A Detail Indicator has a field for Detail ID, but the
name must be looked up in metadata. There are places in the code
where references to the Detail ID field are hardcoded where they should
be looked up, and places where the references are looked up where
they should be hardcoded. This needs to be corrected throughout the
product.

Resolution: Entire codeline has been searched for references to the


Detail ID field and modified to either hardcode the field (G3E_DETAILID)

58
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.09001

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


or look up the name of the field in metadata as is appropriate for the
current situation.
35. 1-8QRUNH G/Technology Fix places in code where Fix places in code where G3E_DETAILS_OPTABLE.G3E_ATTRIBUTENAME
Designer G3E_DETAILS_OPTABLE.G3E_ATTRIBUTENAME is is being used as a table name. It is not a table name. Users must get
being used as a table name. the corresponding table name from G3E_COMPONENTINFO_OPTABLE.

Resolution: Instead of retrieving


G3E_DETAILS_OPTABLE.G3E_ATTRIBUTENAME, the code now retrieves
G3E_DETAILS_OPTABLE.G3E_ATTRIBUTECNO and uses it to get the
G3E_TABLE from G3E_COMPONENTINFO_OPTABLE. This is the table
name to use for later queries.

59
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


1. 1-7ZZ6ZP G/Technology Need ability to configure sort field(s) on horizontal dialog Users need to be able to rely on the rows displayed on horizontal
MobileViewer tabs dialog tabs to be sorted consistently in desktop and Viewer
products in an order configured for the system.

Resolution: Added new column, G3E_ORDERBYKEY, to the


G3E_DIALOGTAB metadata table. This new column will hold the
ORDER BY clause to be applied to the ADO recordset to be used
to populate the HorizontalAttributeGrid. The column was also
added to the language sub-tables and to
G3E_DIALOGS_OPTABLE. The InitializeControl method on the
HorizontalAttributeGrid control looks for the new metadata
column and if a value is found applies the value to the recordset.

This implementation does have the limitation that only one


component can be used in a HorizontalAttributeGrid instance for
the ordering to be used.
2. 1-8QR6VN G/Technology Orderby functionality on horizontal dialog tab is not New metadata is required for the new orderby functionality on
Designer tolerant of missing metadata. horizontal dialog tabs. Code is not tolerant if this metadata is
missing.

Resolution: Modified the HorizontalAttributeGrid logic to handle


the absence of the G3E_DIALOGS_OPTABLE.G3E_ORDERBYKEY
field.
3. 1-8QMWHB G/Technology Upgrade Wizard is hung during running the incremental UpgradeWizard hands when users run
Administrator script ..\Services\IncrementalUpgrades\Build10.02.0002.06001\Metad
ata Upgrade\MG3ELanguageSubTableUtils.sql. Also need to
wrap up this file.

Resolution: The Upgrade Wizard is running properly.


4. 1-7U7H4Q G/Technology Error on specifying the WMS cache server link An error displays when a user specifies the WMS cache server
1-8Q8PNZ Administrator link.

60
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: Added WMS 1.1.1 methods to the Cache Filler WMS
facade and SDI Pro windows service.
5. 1-7XUJQB G/Technology Update GDOGML and GMWMSRasterEngine to latest Update GDOGML and GMWMSRasterEngine to latest version
1-8FEFV4 Designer version from GeoMedia. from GeoMedia.

Resolution: These components have been updated.


6. 1-82I9YF G/Technology Unable perform Zoom operation when WMS layers are When the WMS layer checked in the display control try to Zoom
1-8Q8G1B Administrator turned on in the display control. IN. The zoom scale changing in the status bar but Map Window
does not fit to the Map Window. Uncheck the WMS layer and
perform Zoom operations it works fine. Problem is only
reproduced when there is WMS layer

Resolution: WMS data that cannot be properly transformed does


not cause the G/Technology display to stop rendering.
7. 1-7P6G0O G/Technology NetExport does not work with UNCPath (shared path) NetExport does not work with UNCPath (shared path).
1-8FEFN2 NetExport Server
Resolution: Provided fix by using SetCurrentDirectory winapi
instead of ChDrive and ChDir.
8. 1-7QZ6TW G/Technology Settings not saved correctly to the workspace Customizations to a saved workspace are not being saved when
1-8FEFS2 Designer there is a published menu layout.

Resolution: G/Technology no longer overwrites the "Version"


value in the registry from that which was obtained at the time of
login.
9. 1-7QZCS2 G/Technology All components in the active legend option selects All components in the active legend option selects components
1-8FEFQE Designer components which do not exist in legend which do not exist in the legend.

Resolution: Correctly find the filtered CNOs for the currently


active legend.
10. 1-7TXY6H G/Technology G3E_OWNERSHIP relationship - delete of child features G3E_OWNERSHIP.G3E_DELETE setting is not working when the
1-8Q8G2P Administrator ownership relationship is defined between two non-graphic
features.

61
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: A proper error message is displayed when trying to
delete non- graphic a parent feature with child feature where
G3E_OWNERSHIP.G3E_DELETE = 4. (This is similar to Graphic
feature as Parent.)
11. 1-7UYOF0 G/Technology Problems getting WFS-attributes displayed in Feature Users have set up a simple WFS layer using GeoMedia Web Map:
1-8FEG0O Designer Explorer http://lb.imaps.nu/FFGepProWFS/request.aspx?&service=WFS.
Users can access the service and display attributes in GeoMedia
and in G/Technology. The WFS metadata and features are
shown on the map; however, when users click on the features,
they do not stay "selected" (the highlight stops after a second).
Users cannot explore the attributes of the feature.

Resolution: Provided a fix in the WFS data server so that if the


software fetching the data with an attribute filter fails, the filter
in the url is removed. All feature instances are retrieved.
12. 1-7WGRIV G/Technology Requesting additional diagnostics for Users are sending messages to Message Monitor to update the
1-8Q8JGX Administrator JobProcessingService.cls and DataContext.cls G3E_JOB record RESPONSIBLE_PERSON_NAME. From the
diagnostics log, the update seems to be occurring in the
JobProcessingService.cls and DataContext.cls. The Oracle trace
shows that the update never makes it to the database but
diagnostics shows the update occurred.

Resolution: Moving the error handler logic to the body of the


method corrected this. The specified outgoing queues should
exist, but if not, the software will now clean up correctly and
allow subsequent requests to be processed.
13. 1-7XUJQB G/Technology Update GDOGML and GMWMSRasterEngine to latest Update GDOGML and GMWMSRasterEngine to latest version
1-8FEFV4 Designer version from GeoMedia. from GeoMedia.

Resolution: These components have been updated.


14. 1-8537IF G/Technology Edit common attributes issue related to the performance When using the keyboard to select a field in Edit Common
1-8FEFRS Designer fixes Attributes, the value is not selected by using first letter of the
picklist value and pressing the Enter key. Selecting a field using a
62
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


mouse works fine, and the value can be selected. If the user
replaces the original .28002 dlls, the issue does not occur.

Resolution: Users can select the value from a picklist and press
Enter. The selected value is persisted.
15. 1-86RIBL G/Technology Export to CAD failing when regional settings are set to Users have configured a NetExport server so that the user who
1-8FEG0Y Designer German owns the NetExport service is an Oracle-authenticated user.
They can successfully use the Designer/Analyst Export to CAD
command with a metadata-defined export format when regional
settings are set to English. If users change the regional settings
to German, they get only a log file if logging is turned on. The
issue occurs on a single machine as well as a machine that
connects as a client. Users have noticed that the coordinates for
the MBR are not being honored correctly. For example :

MBR Coordinates for ENGLISH :


364736.145355638,4103474.77803383,365268.266046993,4103
474.77803383,365268.266046993,4103829.09254295,364736.1
45355638,4103829.09254295

MBR Coordinates for GERMAN :


364736,145355638,4103474,77803383,365268,266046993,4103
474,77803383,365268,266046993,4103829,09254295,364736,1
45355638,4103829,09254295

Users are not sure if the "," delimiter might be causing the issue.
It appears that the comma delimited coordinates are being used
as XY coordinates; therefore, instead of four points there are
eight points when regional settings are set to German.

Resolution: Changed the locale settings while retrieving the


extents when using an MBR.

63
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


16. 1-8BHNLW G/Technology NetExport: G/Technology justification does not match Users have found two issues when exporting to MicroStation V8.
1-8Q8JNV NetExport Server justification in MicroStation V8 output. First, if justification is defined as "Left" in G3E_TEXTSTYLE, then
the justification in the MicroStation output will be set to "Left
Margin Center". They are not sure if this is expected results.
Secondly, if the G/Technology snap point is defined as "Left", for
example when moving a text component, then the snap point in
the MicroStation output is set to "Right".

Resolution: By properly mapping the alignment values of


G/Technology to MicroStation supported Justification values,
which FME honors, the problem is resolved.
17. 1-8CTU7F G/Technology Got an Overflow exception during computation of the color The MakePalette function tried to get the
1-8Q8G6V NetViewer palette in MapServer. G3E_STYLEOBJECTS_OPTABLE using GetFilteredRecordset. Inside
GetFilteredRecordset, the call to FilterBookmarksForRecordset
got an overflow on the index of the array of bookmarks because
the index type is an int16 type and the dataset has more than
32K style objects. The index type should have been a VB long
type.

Resolution: Declared iBookmarkCount variable as long and


changed the variable name to lBookmarkCount following the
naming convention in Visual Basic.
18. 1-8FWW1J G/Technology Receiving "Invalid procedure call or argument" error when Customer is in the process of converting their STORMS Work
1-8Q8GAH Designer using command Send to WMIS Management system to a LOGICA Work Management system.
Support has been helping the customer during this conversion.
We believe we have configured all required metadata but now
support needs development's assistance debugging our latest
error message which is "Invalid procedure call or argument". It
appears the failure is occurring in subroutine ProcessFNO in the
send to WMIS source code. We have tried to narrow down the
failure but have been unable to pin point the failure. We can
reproduce the problem locally.

64
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


Resolution: We were not correctly doing a check for PS_TYPE
component name or the field name first before getting the
component recordset and checking for IsNULL while processing
the point span. Also while processing the compatible units we
were not doing a NULL check on action field.
19. 1-8GQ5VF G/Technology Temporary Geometry placement throws error when Users have implemented an IGTTemporaryGeometryPlacement
1-8Q8JSB Administrator G3E_TEMPORARYGEOMETRYPLACEMENT.g3e_autorepeat= interface and it throws the errors when
1. G3E_TEMPORARYGEOMETRYPLACEMENT.G3E_AUTOREPEAT is
set to 1.

Resolution: The New Temporary Geometry command properly


cleans up between each placement of an auto-repeating
temporary geometry placement interface. The SampleGrid
temporary geometry placement interface successfully places a
rectangular series of grid marks.
20. 1-8HPGCD G/Technology Message Monitor: Unable to create new jobs after trying Users are unable to create new jobs in Logica after trying to
1-8Q8GD9 Administrator to create a job that already exists. create a job that already exists in the G3E_JOB table.

Resolution: Moving the error handler logic to the body of the


method corrects this. The specified outgoing queues should
exist. If not, the software will now clean up correctly and allow
subsequent requests to be processed.
21. 1-8I3OZ2 G/Technology NetPlot: G/Technology becomes unstable when submitting Users have found that the G/Technology process is unstable
1-8Q8G39 NetPlot Server multiple plot requests after submitting multiple plots. For example, the first plot
request contains calls to a plot interface, and is successful. If a
second plot request is submitted that makes no calls to a plot
interface, the second plot request fails with an error message:
Automation error The object invoked has disconnected from its
clients. InitializePlot method of CustomPlotInterface failed.
Object variable or With block variable not set. Error occurred
while attaching ad hoc files. Object variable or With block
variable not set. Other error messages are seen after the above
error is seen:
65
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


Error processing the submitted plot request.

Resolution: No error messages are displayed.


22. 1-8MJ5L1 G/Technology Creating new map window after deleting one crashes for a G/Technology crashes when users create a new map window
1-8Q8JLD Designer certain workflow. after deleting one.

Resolution: Creating a new map window is stable.


23. 1-8MJ5MS G/Technology Deleting an embedded map causes G/Technology to stay up Deleting an embedded map causes G/Technology to stay up in
1-8Q8JWH Analyst in memory. memory.

Resolution: The G/Technology application closes correctly after


deleting an embedded map.
24. 1-8NB7CR G/Technology G/Technology crashes when using custom plot interface G/Technology is unstable after using the custom plot interface
1-8Q9X7R NetPlot Server and using G/Technology PDF Converter after second and using the G/Technology PDF Converter. For example, the
request. first plot request will contain calls to a plot interface, and
G/Technology PDF Converter. The first plot request will be
successful. If a second plot request is submitted that makes no
calls to a plot interface, the second plot request will succeed but
G/Technology will crash.

Resolution: Release the custom plot object and call garbage


collector to free up the .NET custom plot object which in turn
was holding onto COM Plot window object.
25. 1-8OAJMN G/Technology Error thrown while debugging temporary geometry An exception is thrown while debugging a temporary geometry
1-8Q8G5R Designer interface. interface implementation. The problem occurs when stepping
over the PlacementHelper.EndPlacement method. The
exception includes the error message: "Object variable or With
block variable not set."

Resolution: EndPlacement logic has been corrected so that you


can successfully debug your temporary geometry placement
interface implementation.

66
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


26. 1-8OAJPA G/Technology The SampleGrid temporary geometry interface gives Fix Overflow error to allow for more than 32 thousand grid
1-8Q8JT5 Designer Overflow error if more than 32767 markers are created markers to be created.

Resolution: The Sample Grid temporary geometry placement


interface now allows more than 32767 markers to be placed.
27. 1-8OLN9B G/Technology Raster data cannot be displayed by NetPlot when Raster file Users need the ability to plot Raster files in NetViewer using CSF
NetViewer with World file used. and world file.

Resolution: NetPlot did not have support to transfer the World


file (.tfw, .sdw or .jgw) to the NetPlot Application Server. Also the
image type for a raster georeferenced by a world file was
incorrectly returning as No Header which resulted in failure to
display raster data.
28. 1-8PVYPX G/Technology Need API for NetViewer/NetPlot formatted connection There is currently an EncryptedConnectionString method in the
Designer string in Designer Designer API, but its format is not valid for use in
NetViewer/NetPlot. Need to extend the API with methods for
retrieving the connection string in ConfigurationName:
;UserName: ;Password: ; format in both plain text and encrypted.

Resolution: Added ViewerConnectionString and


ViewerEncryptedConnectionString methods to the Designer API.
29. 1-8NPAIF G/Technology Update setup to deliver ViewerAPITester sample and Currently G/Technology does not deliver the ViewerAPITester
NetViewer deliver the correct satellite assembly sample used for testing the Viewer Pubic API
(Intergraph.GTechnology.Viewer.dll) assembly. G/Technology
also needs to update setup to deliver satellite assembly
Intergraph.GTechnology.Viewer.resources.dll instead of
ViewerPublicAPI.resources.dll.

Resolution: ViewerAPITester sample is delivered.


Resource file renamed from ViewerPublicAPI.resources.dll to
Intergraph.GTechnology.Viewer.resources.dll

67
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


Deliver Intergraph.GTechnology.Viewer.dll in
Program\GViewerApp\bin as well as Program as it has been
doing.
30. 1-8PIDI2 G/Technology Attach vector Data =] MicroStation V8 file does not show Attach vector Data =] MicroStation V8 file does not show text
Designer text and symbols properly and symbols properly if a symbol with the character 'Y' ( symbol
with fill ) exists in a design file. This is due to a problem in the
underlying TEIGHA library =]

Resolution: The symbols in a design file that has the symbols


made of complex shape fill are visible when the file is attached.
31. 1-8O2MYL G/Technology Size of text in plot window and map window is increasing Steps to reproduce:
Designer after clicking on Export to V7 and V8 formats 1. Invoke a map window and zoom to an area where poles
(poles in INS state) are visible.
2. Open the plot window and replace the map frame with map
window1.
3. Place redline text in the plot window with style name as Pole
label – INS and increase the size to a high value. Click on
Export to DGN MicroStation V7 or V8 format.
4. After export, observe that the text size is increased for all
the pole labels in INS state in the plot and map window.

Resolution: Provided fix to take a copy of original style so that


actual style will not be modified.
32. 1-5OF17X G/Technology Export CAD to MicroStation V7 is shifting the origin of Oriented point features are written to V7 DGN with a wrong
Designer G/Technology oriented points coordinate (shifted about .5 to 1m).

Resolution: Fixed the problem of origin shift for oriented points


for V8. For V7, the user needs to set the resolution in the seed
file so that the precision is more accurate and the origin is
correctly set.
33. 1-8GJ17Z G/Technology Request a new help topic describing the creation of Inner Help has topics for Formations and Ducts, but not Inner Ducts.
Administrator ducts Customer requests an inner duct topic to be added that outlines
the placement of inner ducts.
68
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce

Resolution: Added the new Designer/Analyst topic Placing Inner


Ducts and made tweaks to topics that talk about
defining/configuring/placing ducts.
34. 1-8OL2CJ G/Technology Metadata documentation is out of date for horizontal grid Metadata documentation is out of date for horizontal grid.
Administrator
Resolution: Updated G3E_DIALOGTAB, Dialog Tab Presentation ,
Dialog Tabs Metadata topics.
35. 1-8OFPN1 G/Technology Area fill overrides for attached redlines do not work if area Steps to reproduce:
Designer has transparent or hatched fill style. 1. Use the Attach Redlines command to attach a redline
file with areas that have either a transparent or hatched fill
style.
2. Select the new node in the Display Control.
3. Click the Symbology button in the Display Control
toolbar.
4. Turn on the Override color checkbox.
5. Select a fill color and click OK.
6. The fill color is not applied to areas that have a transparent
or hatched fill style. If users override translucency at this
point, the fill color appears properly for the hatched areas,
but the fill color is not quite right for the areas that had the
transparent fill style.

Resolution: If a fill color, and optionally translucency, overrides


are selected, they are properly applied to areas that started with
a transparent or hatched fill style.
36. 31744_U G/Technology Highlight of components if an additional component is Steps to reproduce:
Designer added 1. Place a feature with some different graphic components
that are visible in different legends.
2. Add an additional graphic component to this feature using
New Component.

69
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


All previously placed components are displayed during the
placement even if there is no entry in the legend of the actual
map window for some of the components (e.g. overview
components).

Resolution: Components that are not part of active legend do


not display and the behavior is similar to Feature Explorer (add
new component via Geometry tab).
37. 1-8NWGF7 G/Technology Fix queries to correctly handle the detail ID column names Fix queries to correctly handle the detail ID column names.
Analyst Details themselves always reside in G3E_DETAILDID. But, detail
indicator column names have to be looked up in metadata.
Simple queries (with AOI) does not follow that rule.

Resolution: Simple queries execute correctly.


38. 1-8NPAGT G/Technology Fix issues in Viewer API for Engineering Plotting and The following issues related to Engineering Plotting work in
NetViewer ViewerAPITester sample. Viewer Public API and the Viewer Test sample need to be fixed:
 The name of the Viewer Public API assembly
Intergraph.GTechnology.Viewer.dll and its satellite assembly
were different, which threw an error missing satellite
assembly.
 The GetFileAttachments method was failing when a .csf file
was used instead of registration points to attach CAD data.
 In the ViewerAPITester sample G/Technology used a printer
description field instead of a printer name field of
GDR_GNVPRINTERS table which required both the fields to
be same.

Resolution: Correct the name of the satellite assembly for


Intergraph.GTechnology.Viewer.dll to
Intergraph.GTechnology.Viewer.resources.dll.
 A list of RegistrationPoint objects collection was not
initialized and was NULL, which was used to create read-only
collection in the case when the .csf file was used to attach
70
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce


ad hoc data in GetFileAttachments method in Viewer Public
API (Intergraph.GTechnology.Viewer.dll).
 ViewerAPITester sample used printer
39. 1-8NJ9DJ G/Technology Add support for binding NULL values to Engineering Plotting When using bound values in calls to
Designer API IDataRequestService.ExecuteBoundArray, the support for
binding NULL values is missing. It is not possible to pass null
object or DBNull.Value object reference in parameters. The
underlying code does not recognize it as a valid value and either
skips its processing (in case of null reference) or reports invalid
use of NULL (in case of DBNull.Value).
In G/Designer API call DataContext.Execute it is possible to pass
DBNull.Value as a parameter.

Resolution: When generating the parameters collection the


software checks if a parameter is null. If so, it creates a
parameter of type adVarChar, with adParamNullable for
Attributes, a size of 1, and a value of Null. This was tested in
NetViewer and MobileViewer with several field types.
40. 1-8LWSHP G/Technology Redline Service API not handling embedded objects in the RedlineService API is treating the embedded objects in a plot
Designer plot window window as Windows and throwing an unhandled exception when
a user tries to generate XML.

Resolution: AddPlotFramesToDataGrid method ignores all


IGTPlotFrame objects that are not of the type, gtpftMap.
41. 1-8LLYWP G/Technology Attached AutoCAD file is exported using SaveAsDGN API. When an AutoCAD file is attached and exported to V7 or V8
Designer Text in file is visible as individual element using SaveAsDGNAP, text, multiline text or arc aligned text in the
file is exported as single elements (shapes), not as text.

Resolution: Enhanced code to honor text elements and text will


be exported as expected.
42. 1-8LRZ2D G/Technology Slight shift in the text elements from the attached DGN file Attach a DGN file in G/Technology and export it to DGN using
Designer when exported using SaveAsDGNAPI SaveAsDGNAPI. There is a shift observed in text and point
symbols.
71
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.06001, .06002, .06003

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed specifically for the current
software version.
 A database upgrade is required for this release.

CR # Product Summary Description/How to Reproduce

Resolution: The software sets the font header correctly for all
the fonts.

72
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.05001 – RTM

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed
specifically for the current software version.
 A database upgrade is required for this release.

CR # Product Summary Description / How to Reproduce


1. 1-6A9YFW G/Technology Persisted Deltas Service While running a couple of performance tests, users found the service
Administrator failed with this error code: works fine till they reached approximately 100 thousand records with
0x800a0007 ltt_id=0 in the modificationlog. Then the “Deltas Errored with this code:
0x800a0007” message can be seen in the operating system Application
Event Log and no .dlt file is created. The VMWar- based server has 4GB of
memory. It seems like error occurs as the service's memory consumption
reaches approximately 500MB.
2. 1-7Z0504 G/Technology Feature does not highlight A feature does not highlight the exact related feature for the Node
Administrator the exact feature for Node Ordered Connectivity single feature dialog.
Ordered Connectivity
single feature dialog
3. 1-7GXF7M G/Technology G/Technology 10.2 The 10.2 Upgrade Wizard fails at a step where it loads G3E_MENULAYOUT
1-8FEFLO Administrator Upgrade Wizard fails due from a dump file. Prior to loading the dump file, the upgrade creates a
to oracle permission tablespace named COBBT1010 but fails to alter the user quota to allow the
dump file to be imported
4. 1-85ONZB G/Technology PlotService public API PlotService public API has a wrapper class issue.
1-8FEFXW Administrator issue with wrapper classes
5. 1-89GJPV G/Technology Unions with Attribute Unions with attribute queries fails.
1-8FEG2C Administrator Queries Fails
6. 1-89ZI0V G/Technology IGTDisplayService.Replace When calling IGTDisplayService.ReplaceLegend() with a detail ID
1-8FEG72 Administrator Legend() throws exception corresponding to a detail whose indicator exists in only one Indicator
for owned detail IDs symbol, an exception is thrown "Could not retrieve detail information for
the given detail id".
7. 1-8IF7QP G/Technology Add FindAssembly public Provide a method in the G/Technology public API to discover custom
Analyst API assembly locations. This will allow all G/Technology add-on software to
find its custom interface implementations in the same locations that
G/Technology discovers theirs.
8. 1-7XQBF7 G/Technology UseRscFonts parameter in If the user adds the full path of the .rsc file for DgnFontRscFile and sets
Designer gt.ini file is not honored. UseRscFonts to 0 or 1 or removes UseRscFont from gt.ini file, the attached

73
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.05001 – RTM

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed
specifically for the current software version.
 A database upgrade is required for this release.

CR # Product Summary Description / How to Reproduce


MicroStation file uses the fonts stored in the .rsc file. Consider the cases
below:
Case 1: DgnFontRscFile= C:/font.rsc (the full path to the location of the .rsc
files) and UseRscFonts=0, Result: The attached MicroStation file uses the
fonts stored in the .rsc file.
Case 2: DgnFontRscFile= C:/font.rsc (the full path to the location of the .rsc
files) and UseRscFonts=1. Result: The attached MicroStation file uses the
fonts stored in the .rsc file.
Case 3: DgnFontRscFile= C:/font.rsc (the full path to the location of the .rsc
files) and comment the UseRscFonts (i.e., # UseRscFonts=1) or delete this
parameter Result: The attached MicroStation file uses the fonts stored in
the .rsc file.
9. 1-7OOA2M G/Technology Getting ORA-01747 error Users are getting an ORA-01747 error while working with predefined
1-8FEFLE Designer while working with queries.
predefined queries.
10. 1-7ULHJD G/Technology Pole attribute query that A pole attribute query that currently works in 10.1 now produces an
1-8FEFOQ Designer currently works in 10.1 Oracle error.
now produces ORA error
11. 1-7OOA6D G/Technology Getting ORA-00907 error Users are getting an ORA-00907 error while working with predefined
1-8FEFQ4 Designer while working with queries.
predefined queries
12. 1-7QZCS2 G/Technology All components in the All components in the active legend option selects components which do
1-8FEFQE Designer active legend option not exist in the legend.
selects components which
do not exist in the legend
13. 1-8537IF G/Technology Edit common attributes When selecting a field in Edit Common Attributes which has a pick list via
1-8FEFRS Designer issue related to the the keyboard, the value is not selected if selected via first letter of the pick
performance fixes list value and press the enter key. If selected via mouse clicks, it works
(value can be selected). If a user replaces the original .28002 .dlls, the

74
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.05001 – RTM

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed
specifically for the current software version.
 A database upgrade is required for this release.

CR # Product Summary Description / How to Reproduce


issue does not occur. Note that when using backspace/arrows and so
forth, after selecting a value either with keyboard or mouse, the software
presents more errors.
14. 1-7QZ6TW G/Technology Settings not saved Customizations to a saved workspace are not being saved when there is a
1-8FEFS2 Designer correctly to the workspace published menu layout.
15. 1-85KD0Q G/Technology "Object reference not set Within the same session of G/Technology, if users close a workspace and
1-8FEFVY Designer to an instance of an open an existing or new workspace and try to run any Fiber Optic Works
object" error thrown command like Fiber Feature Explorer or Fiber Feature Edit, they see this
when running Fiber Optic error: "Object reference not set to an instance of an object" error. This
Works commands. error is thrown when running any .NET custom command which uses
GTClassFactory to create public objects after switching workspace within
same G/Technology session.
16. 1-83WSW4 G/Technology Plot window Hide When users have synthesized components configured in the Display
1-8FEFW8 Designer Component command Control and run the Hide Component command on a plot window, the
does not honor synthesized component is not hidden.
synthesized components
17. 1-86W0KM G/Technology The 10.2 application The application will crash opening a saved workspace then using file open
1-8FEFZ0 Designer crashes when selecting an to open another saved workspace.
older workspace
18. 1-852PKV G/Technology Changes made to upgrade Changes made to upgrade WMS functionality are reverted. Changes
1-8FEFZA Designer WMS functionality originally made in 10.01.0003 are integrated here.
reverted
19. 1-7UYOF0 G/Technology Problems getting WFS- Users have set up a really simple WFS-layer using GeoMedia WebMap:
1-8FEG0O Designer attributes displayed in http://lb.imaps.nu/FFGepProWFS/request.aspx?&service=WFS. They are
Feature Explorer able to access the service and display attributes in GeoMedia and in
G/Technology, and the WFS-metadata and features are shown on the map.
However, when clicking on the features, they do not stay "selected" (the
highlight stops after a second) and users are not able to explore the
attributes of the feature.

75
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.05001 – RTM

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed
specifically for the current software version.
 A database upgrade is required for this release.

CR # Product Summary Description / How to Reproduce


20. 1-86RIBL G/Technology Export to CAD failing Users have configured a NetExport server so that the user who owns the
1-8FEG0Y Designer when regional settings are NetExport service is an Oracle-authenticated user. They can successfully
set to German. use the Designer/Analyst Export to CAD command with a metadata-
defined export format when regional settings are set to English. If users
change the regional settings to German, then they only get a log file if
logging is turned on. They see this problem with a single machine as well
as a machine that connects as a client. There are no error messages in the
debug log files but users have noticed that the coordinates for the MBR
are not being honored correctly. For example : MBR Coordinates for
ENGLISH :
364736.145355638,4103474.77803383,365268.266046993,4103474.7780
3383,365268.266046993,4103829.09254295,364736.145355638,4103829.
09254295
MBR Coordinates for GERMAN :
364736,145355638,4103474,77803383,365268,266046993,4103474,7780
3383,365268,266046993,4103829,09254295,364736,145355638,4103829,
09254295 Users are not sure if the "," delimiter might be causing the
issue. It appears that the comma-delimited coordinates are being used as
XY coordinates, therefore instead of 4 points there are 8 points when
regional settings are set to German.
21. 1-87X9B3 G/Technology Keyboard navigation When selecting a field in the Edit Common Attributes which has a pick list
1-8FEG2M Designer produces inconsistent via the keyboard, the value is not selected if selected via first letter of the
results and errors in pick list value and press the enter key. If selected via mouse clicks, it works
Common Attribute Edit (value can be selected). If a user replaces the original 28002 .dlls, the issue
does not occur. Note that when using backspace/arrows and so forth, after
selecting a value either with keyboard or mouse, the software presents
more errors.
22. 1-8EX944 G/Technology Getting an error while Users are getting an error while editing detail feature “Unable to retrieve
1-8FEG40 Designer editing detail feature information necessary to place this feature".

76
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.05001 – RTM

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed
specifically for the current software version.
 A database upgrade is required for this release.

CR # Product Summary Description / How to Reproduce


23. 1-88RUJP G/Technology Cable path trace upstream A schematic drawing is not showing the correct display based upon trace
1-8FEG5O Designer schematic Incorrect results.
feature display
24. 1-8E3VZE G/Technology While placing detail While placing detail components of any feature, users receive the
1-8FEG6S Designer components of any following error: Unable to update with changes made to the last
feature, users receive an component. Complete Component Relation List. Error in
error ComponentComplete: Item cannot be found in the collection
corresponding to the requested name or ordinal.
25. 1-8E3VM2 G/Technology Getting P1 error while Users get a P1 error while posting or validating a detail feature: "Error
1-8FEG86 Designer posting or validating detail creating or using relationship Detail Area".
feature
26. 1-7P6G0O G/Technology NetExport does not work NetExport does not work with FileUNCPath (Shared Path).
1-8FEFN2 NetExport with FileUNCPath (Shared
Server Path)
27. 1-7HSMCN G/Technology Symbols defined with fill Users have defined symbols in a cell library to have a fill type of "Opaque".
1-8FEFNC NetExport type are not filled after These symbols place in MicroStation with the correct fill type, but when
Server export exporting those same symbols , the fill type is not correct. Users have set
G3E_CELLNAMEMAP to CELL_NAME:1, which should retrieve color and fill
color.
28. 1-889M8Q G/Technology NetExport failing when Users have configured metadata for NetExport so they can export land
1-8FEG4A NetExport trying to export published data that has been created with a secondary data connection. This land
Server secondary data data was not imported. Users made a secondary data connection and
published the information to a DDC file. When they execute the export,
they get the following error message: REQUEST__ERROR Duplicate Table
found. Cannot re-register table type 'VPF' ORA-00942: table or view does
not exist.
29. 1-7LKWB5 G/Technology Unable to configure the After installing the NetViewer Server on a Windows Server 2008 machine,
1-7M1M95 NetViewer NetViewer Server on users are unable to configure the NetViewer Server. After selecting the
Windows Server 2008

77
G/Technology 10.2 SP2 Issues Resolved
10.02.0002.05001 – RTM

 If two CRs numbers appear in the CR # column, the first CR listed is the primary occurrence of the issue. The second CR listed is a multiple occurrence CR filed
specifically for the current software version.
 A database upgrade is required for this release.

CR # Product Summary Description / How to Reproduce


NetViewer Server Configuration Wizard, users see the following error:
Run-time error '429': ActiveX component can't create object .
30. 1-81H3YQ G/Technology Feature by address search Feature by address search does not work in French for a feature that has
1-8FEFTQ NetViewer does not work in French an apostrophe in the name.
for feature that has an
apostrophe
31. 1-5GLNYG G/Technology Attach Vector data throws Attach Vector data throws an error "The font resource file xxxxx.rsc is an
Designer an error when used with a unrecognized format. The DGN file will be displayed, but the fonts from
valid resource file. the font resource file will not be used". The resource file was generated
with MicroStation V7.
32. 1-6RAWL7 G/Technology File>Export to CAD design Using the default delivered seed file for MicroStation v8.01, a File>Export
Designer file does not print from to CAD design file, when opened in MicroStation v8.01, does not
MicroStation print/plot. Using the same version of MicroStation and drawing an
element in MicroStation prints fine.
33. 1-7ZZ789 G/Technology Unable to see the data Unable to see the data after attaching a CAD file.