Building On Success: Cavity FL Oor Boxes..

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 45

NEW cavity floor boxes...

building on success
Legrand’s new range of cavity floor boxes offer a modular product that is simpler to order.
Components are sold separately enabling any configuration to be accommodated on site.

Available in 1, 2, 3 and 4 compartments and three


depths - the new range has been developed with a host
of special features:
• Rapid fit and remove mechanism
• Reversible lid
• Push fit detail to secure base in the floor
• 1 compartment floor box is designed to better
accommodate moulded plugs

Full range of module and accessory plates Bespoke metal trims are available in any RAL reference to
suit a building’s design scheme

Feature Pages.indd 8 21/09/2012 17:59


Reversible lid

2 cable outlets with sponge


foam to prevent ingress

Rapid fit /remove mechanism


adjusts for flooring thickness Durabable ABS trim and
lid surround

Full range of power and data


module plates

Removable base for easy Rapid fit push lock secures


20mm and 25mm knockouts Inter-compartment knockouts
wiring base in floor aperture

Feature Pages.indd 9 21/09/2012 18:01


cavity floor service outlet boxes NEW
selection chart

No. of compartments

Floor box base

Cavity floor box base 75 mm deep

Depth Cavity floor box base 85 mm deep

Cavity floor box base 110 mm deep

Socket outlet plates

13 A twin switched socket plate

13 A twin unswitched socket plate

13 A standard 13 A twin switched clean earth socket plate

13 A triple unswitched socket plate

13 A triple unswitched clean earth socket plate

13 A twin NS switched socket plate

13 A non-standard 13 A twin NS unswitched socket plate

13 A twin NS switched clean earth socket plate

2 gang RCD socket plate


RCD
2 gang RCD socket plate – clean earth

37 x 22 mm – 2 cut-out plate

37 x 22 mm – 4 cut-out plate

Data 37 x 22 mm – 4 cut-out wave plate

37 x 22 mm – 6 cut-out plate

47·5 x 23·5 mm – 4 cut-out plate

2 x standard single outlet 60·3 mm

Standard 2 gang outlet plate 120·6 mm

50 x 50 mm – 1 cut-out plate

General 50 x 50 mm – 2 cut-out plate

Blank plate

58 x 53·5 mm – 1 cut-out plate to accept Arteor mounting frame(1)

58 x 53·5 mm – 2 cut-out plate to accept 2 x Arteor mounting frames(1)

Lids and trims

ABS with carpet trim – 6 mm recess

Combination with edge trim – 6 mm recess

Metal, powder coated with carpet trim – 6 mm recess

Metal, powder coated with edge trim – 10 mm recess

Stainless steel with carpet trim – 6 mm recess

Stainless steel with edge trim – 10 mm recess

Brass with carpet trim – 6 mm recess

Brass with edge trim – 10 mm recess

(1) For Arteor mounting frames, refer to the latest Wiring Devices catalogue

10

010_011_Floor_2012 v4.indd 10 21/09/2012 14:28


1 compartment 2 compartment 3 compartment 4 compartment

– CAV275 CAV375 CAV475

CAV185 CAV285 CAV385 CAV485

– CAV2110 CAV3110 CAV4110

SP3201 SP3201 SP3201 SP4201

SP3200 SP3200 SP3200 SP4200

SP3211 SP3211 SP3211 SP4211

SP3300 SP3300 SP3300 SP4300

SP3310 SP3310 SP3310 SP4310

SP3221 SP3221 SP3221 SP4221

SP3220 SP3220 SP3220 SP4220

SP3231 SP3231 SP3231 SP4231

SP3202 SP3202 SP3202 SP4202

SP3212 SP3212 SP3212 SP4212

SP3203 SP3203 SP3203 SP4203

SP3403 SP3403 SP3403 SP4403

SP3404 SP3404 SP3404 SP4404

SP3603 SP3603 SP3603 SP4603

SP3408 SP3408 SP3408 SP4408

SP3205 SP3205 SP3205 –

SP3105 SP3105 SP3105 –

SP3106 SP3106 SP3106 SP4106

SP3206 SP3206 SP3206 SP4206

SP3000 SP3000 SP3000 SP4000

SP3107 SP3107 SP3107 SP4107

SP3207 SP3207 SP3207 SP4207

– FBL2ABS FBL3ABS FBL3ABS

– FBL2COM FBL3COM FBL3COM

FBL1MCT FBL2MCT FBL3MCT FBL3MCT

FBL1MET FBL2MET FBL3MET FBL3MET

FBL1SCT FBL2SCT FBL3SCT FBL3SCT

FBL1SET FBL2SET FBL3SET FBL3SET

FBL1BCT FBL2BCT FBL3BCT FBL3BCT

FBL1BET FBL2BET FBL3BET FBL3BET

11

010_011_Floor_2012 v4.indd 11 21/09/2012 14:11


cavity floor service outlet boxes NEW

CAV385

CB3

CAV185

CAV285

picto loupe-65765j.eps

CAV4110

Cavity floor service outlet boxes selection chart (p. 10-11)


Dimensions and technical information (p. 16)

Pack Cat. Nos. Cavity floor boxes Pack Cat. Nos. Cavity floor boxes (continued)
Contractor floor box 3 compartment floor box base
upplied empty
S ecommended hole cut-out size :
R
Ready to accept standard BS two gang wiring 340-342 mm x 203-205 mm
accessories 1 CAV375 75 mm deep
Additional mounting plates not required 1 CAV385 85 mm deep
Recommended hole cut-out size : 1 CAV3110 110 mm deep
302-304 mm x 219-221 mm
7 mm lid recess 4 compartment floor box base
Standard depth : 85 mm
20/25 mm knockouts to each compartment ecommended hole cut-out size :
R
Manufactured from pre-galvanised steel to 340-342 mm x 203-205 mm
BS EN 10142 and 3, and polycarbonate/ABS 1 CAV475 75 mm deep
1 CB3 3 compartment contractor floor box 1 CAV485 85 mm deep
1 CAV4110 110 mm deep
Slab floor box
1 SLAB1 1 compartment
1 SLAB2 2 compartment
Floor box bases 1 SLAB3 3 compartment
upplied empty
S 1 SLAB4 4 compartment
Lids and trims are detailed on p. 13
Outlet plates are detailed on p. 13
1 compartment floor box base
ecommended hole cut-out size :
R
165-167 mm x 203-205 mm
1 CAV185 85 mm deep
2 compartment floor box base
ecommended hole cut-out size :
R
263-265 mm x 203-205 mm
1 CAV275 75 mm deep
1 CAV285 85 mm deep
1 CAV2110 110 mm deep

Cavity floor boxes and slab boxes are Floor boxes with built-in RCD and RCBOs
available pre-wired to tap-offs are also available

see p. 15 Contact us on +44 (0) 870 608 9020

12

012_Floor_2012 v4.indd 12 21/09/2012 14:13


outlet plates for floor boxes NEW lids and trims for floor boxes NEW
power and data

picto loupe-65765j.eps picto loupe-65765j.eps

Dimensions and technical information (p. 16) Dimensions and technical information (p. 16)
Cavity floor outlet boxes selection chart (p. 10-11) Cavity floor outlet boxes selection chart (p. 10-11)
Installation details (p. 17) Installation details (p. 17)
Plates to fit 1, 2 and 3 compartment boxes are all 100 mm wide Moulded lids and trims are manufactured from durable ABS and feature a
4 compartment plates are 75 mm wide quick fit / release ratchet system
Non-standard sockets have a round earth pin Carpet trim versions are supplied with a 6 mm carpet recess
Due to overall depth, RCD sockets and wave type data plates will NOT fit Edge trim versions are supplied with a 10 mm recess
in the flush floor and shallow flush floor ranges (Cat. Nos. FFO/AFS) Metal trim versions are powder coated grey RAL 7024 matt as standard
When using with underfloor duct systems (Cat. No. AFU) the outlet box Stainless steel is satin finish as standard
must be raised by 8 mm from the lowest point to allow for wiring Brass is polished finish as standard
Pack Cat. Nos. Power and data plates Pack Cat. Nos. Floor box lids and trims
1, 2, 3 comp. 4 comp. 1 and 2 compartment
100 mm wide 75 mm wide 1 comp. 2 comp.
13 A standard socket plates Carpet trim
1 SP3201 SP4201 Twin switched 1 – FBL2ABS BS
A
1 SP3200 SP4200 T win unswitched 1 FBL1MCT FBL2MCT Metal – grey
socket plate 1 FBL1SCT FBL2SCT Stainless steel
1 SP3211 SP4211 Twin switched clean earth 1 FBL1BCT FBL2BCT Brass
1 SP3300 SP4300 Triple unswitched
1 SP3310 SP4310 Triple unswitched
clean earth Edge trim
13 A non-standard socket plates 1 – FBL2COM ABS lid/metal trim – ABS/grey
1 FBL1MET FBL2MET Metal – grey
1 SP3221 SP4221 Twin NS switched 1 FBL1SET FBL2SET Stainless steel
1 SP3220 SP4220 T win NS unswitched 1 FBL1BET FBL2BET Brass
1 SP3231 SP4231 Twin NS switched
clean earth

RCD socket plates


3 and 4 compartment
1 SP3202 SP4202 2 gang
1 SP3212 SP4212 2 gang – clean earth Carpet trim
1 FBL3ABS ABS
1 FBL3MCT Metal – grey
Data plates 1 FBL3SCT Stainless steel
1 SP3203 SP4203 37 x 22 mm – 2 cut-outs 1 FBL3BCT Brass
1 SP3403 SP4403 3 7 x 22 mm – 4 cut-outs Edge trim
1 SP3404 SP4404 37 x 22 mm – 4 cut-outs 1 FBL3COM ABS lid/metal trim – ABS/grey
(wave plate) 1 FBL3MET Metal – grey
1 SP3603 SP4603 37 x 22 mm – 6 cut-outs 1 FBL3SET Stainless steel
1 SP3408 SP4408 47·5 x 23·5 mm – 4 cut-outs 1 FBL3BET Brass

General
1 SP3205 -
x standard single outlet 60·3 mm
2
1 SP3105 -
Standard 2 gang
outlet plate 120·6 mm
1 SP3106 SP4106 50 x 50 mm –
1 cut-out plate
1 SP3206 SP4206 50 x 50 mm –
2 cut-out plate
1 SP3000 SP4000 Blank plate
1 SP3107 SP4107 58 x 53·5 mm – 1 cut-out
plate to accept Arteor
mounting frame (Cat. No. 576016)(1)
1 SP3207 SP4207 58 x 53·5 mm – 2 cut-outs plate to accept
2 x Arteor mounting frames Metal lids and trims can be powder coated
(Cat. No. 576016)(1) to any RAL reference. Other options, such as
Fasteners lockable lids, are available to special order
50 SPSCREW M3·5 x 6 spare socket plate screws
Contact us on +44 (0) 870 608 9020
(1) For Arteor mounting frames, refer to the latest
Wiring Devices catalogue

13

013_Floor_2012 v5.indd 13 21/09/2012 16:03


cavity floor grommets

0893 07

picto loupe-65765j.eps
AM1 C
LSG2

Dimensions and technical information (p. 16)

Pack Cat. Nos. 150 mm plastic grommets Pack Cat. Nos. 125 mm aluminium grommets
W
Hole size 152 mm ole size 127 mm
H
NE le 201 3 Carpet recess optional on power versions Body – cast aluminium
il a b
A va Secured by quarter-turn fasteners Lid – injection moulded plastic Nylon 66 with
neoprene cable gasket
1 SG6 Access grommet Secured by quarter-turn fasteners
Allows power, data and flexible conduit Floor depth 25 to 55 mm
up to 32 mm to pass safely through Access grommet depth 60 mm
raised access floor (95 mm when back box included)
Maximum number of conduit entries :
9 x 20 mm Ø 1 089307 Access grommet
5 x 25 mm Ø Allows power, data and flexible
3 x 32 mm Ø conduit up to 25 mm to pass safely
through raised access floor
1 PG6 13 A power grommet
Supplied complete with
13 A unswitched socket 1 AM1C 13 A power grommet
Supplied complete with 13 A
unswitched socket
1 PG6RCD RCD power grommet
Supplied complete with 13 A RCD socket
1 PG6PD 13 A power/data grommet 250 mm grommet
Supplied complete with 13 A socket and
1 x 37 x 22 mm cut-out ole size 250 mm
H
Manufactured from polycarbonate/ABS
1 PG6D Data grommet Colour : grey to BS 4800 18B25
Supplied complete with data plate Secured by quarter-turn fasteners
2 x 37 x 22 mm cut-out Floor depth 15 to 35 mm
7 mm lid recess
Depth 55 mm
1 LSG2 Access grommet
Allows power, data and flexible
conduit up to 32 mm to pass safely
through raised access floor

All power grommets are available


pre-wired

Refer to p. 15 for pre-wired Cat. Nos.

14

014_Floor_2012 v3.indd 14 21/09/2012 14:22


pre-wired cavity floor boxes, slab boxes and grommets NEW
configuration table

The table below details the elements required to correctly order a pre-wired floor box, slab box or grommet
Simply suffix the outlet unit Cat. No. with the relevant “PR” Cat. No. from the table
Outlet options are detailed in the cavity floor box section and the tap-offs are detailed within the power track section, eg :

4 compartment cavity floor box, 110mm deep pre-wired with 2 x clean earth twin switched sockets to a CTO3F tap-off = CAV4110PR23
3 compartment slab box, pre-wired with 1 x twin switched socket to a ST05F tap-off = SLAB3PR3

Tap-off Cat. Nos. ST03U ST03F ST05F CT03U CT03F CT05F

1 x 13 A standard socket outlet

13 A twin switched socket plate PR1 PR2 PR3

13 A twin unswitched socket plate PR4 PR5 PR6

13 A twin switched clean earth socket plate PR7 PR8 PR9

13 A triple unswitched socket plate PR10 PR11 PR12

13 A triple unswitched clean earth socket plate PR13 PR14 PR15

2 x 13 A standard socket outlets

13 A twin switched socket plate PR16 PR17 PR18

13 A twin unswitched socket plate PR19 PR20 PR21

13 A twin switched clean earth socket plate PR22 PR23 PR24

13 A triple unswitched socket plate PR25 PR26 PR27

13 A triple unswitched clean earth socket plate PR28 PR29 PR30

1 x 13 A non-standard

13 A twin NS switched socket plate PR31 PR32 PR33

13 A twin NS unswitched socket plate PR34 PR35 PR36

13 A twin NS switched clean earth socket plate PR37 PR38 PR39

2 x 13 A non-standard

13 A twin NS switched socket plate PR40 PR41 PR42

13 A twin NS unswitched socket plate PR43 PR44 PR45

13 A twin NS switched clean earth socket plate PR46 PR47 PR48

1 x RCD

2 gang RCD socket plate PR49 PR50 PR51

2 gang RCD socket plate – clean earth PR52 PR53 PR54

2 x RCDs

2 gang RCD socket plate PR55 PR56 PR57

2 gang RCD socket plate – clean earth PR58 PR59 PR60

15

015_Floor_2012 v3.indd 15 21/09/2012 15:25


cavity floor service outlet boxes and grommets
technical information

n Cavity floor 195


service outlet boxes 315
n 150 mm plastic grommets
Contractor floor box Access grommet
Cut-out 302-304 mm x 219-221 mm Cat. No. SG6
195
237 315
225

55
A 246 232
237
87 87 87
225
46 Ø148
85 A 246 232 Ø 169
35 87 87 87
Power grommet
46
85 132 Cat. No. PG6
35
60
132

102
Cavity Box
3Cutout
Compartment
D B C W L Plate Size
Ø148 90
CAV185 85 195 45 40 165 302 203 100 Ø 169
87 87 87
CAV275 75 Lid 35 40 263 203 100
35
75CAV285 85 45 40
265 263 203 100
220 n 125 mm aluminium grommets
195 40
CAV2110 110 237 45 65 263 Base
Steel 203
302 Box 100
CAV375 75 225
270 Lid 35 40 65340 65 203
65 65 100 Access grommet
CAV385
A 85
303 45 40 340 203 100 Cat. No. 089307
Carpet Trim Frame
CAV3110 110 237 45 65 340
Steel Base203
Box 100
80 4 Compartment
80 80
CAV475 75 225 35 40 340 203 75 60
41 Steel Base Box
CAV485
80 A 85 45
Carpet Trim Frame
40 340 203 75 60
CAV4110
39 110 45 65 80
340 80 203 80 75 40
95
41 Steel Base Box
Floor80box bases 165
90
Cat. Nos.39CAV1, CAV2, CAV3 and CAV4
144
195
W 302 13 A power grommet
165
Lid 3 compartment Cat. No. AM1C
195
237 302
100 100 100 60
225 40
Lid 95
C
D A Carpet Trim Frame 229
232 L 225
237 B
86 86 86
225 75 75 75 75 265
50 Steel Base Box 144
83 A Carpet Trim Frame 232 225
33 55
86 86 86
4 compartment
50 Steel Base Box
n 250 mm grommet
83 131 248
33
265
131
55

248

Cat. No. LSG2

All dimensions (mm) are nominal

16

016_017_Floor_2012 v3.indd 16 21/09/2012 16:05


cavity floor service outlet boxes and grommets
installation

Cut
Cut
CutCut
hole
hole
hole
hole in
inin
in floor
floor
floor
floor tile
tile
tile
tile
Minimum
Minimum
MinimumMaximum
Minimum Maximum
Maximum Minimum
Maximum Minimum
MinimumMaximum
Minimum Maximum
Maximum
Maximum

11
AA
AA BB
BB
11
1 compartment
compartment
1 compartment
compartment 165
165
165
165 mm
mm
mmmm 167
167
167
167 mm
mm
mmmm 203
203
203
203 mm
mm
mmmm 205
205
205
205 mm
mm
mmmm
22
2 compartment
compartment
2 compartment
compartment 263
263
263
263 mm
mm
mmmm 265
265
265
265 mm
mm
mmmm 203
203
203
203 mm
mm
mmmm 205
205
205
205 mm
mm
mmmm
33
3 compartment
compartment
3 compartment
compartment 340
340
340
340 mm
mm
mmmm 342
342
342
342 mm
mm
mmmm 203
203
203
203 mm
mm
mmmm 205
205
205
205 mm
mm
mmmm
44
4 compartment
compartment
4 compartment
compartment 340
340
340
340 mm
mm
mmmm 342
342
342
342 mm
mm
mmmm 203
203
203
203 mm
mm
mmmm 205
205
205
205 mm
mm
mmmm

PUSH
DOWN

Install
Install
Install
Install box
box
box
box

22
Lower
Lower
Lower
Lower base
base
base
base box
box
box
box into
into
into
into aperture
aperture
aperture
aperture and
and
and
and push
push
push
push firmly
firmly
firmly
firmly
down
down
down
down
This
This
This
This will
willwill
will engage
engage
engage
engage the
thethe
the fixing
fixing
fixing
fixing latches
latches
latches
latches

Fitting
Fitting
Fitting
Fitting lid
lid
lidlid
and
and
and
and trim
trim
trim
trim

33
Lid
Lid
LidLid
and
and
andandtrim
trim
trim
trim isis
is ais
a
a simple
simple
a simple
simple push
push
pushpush fit
fit
fit fit
11
1 The
1The
The
The rachets
rachets
rachets
rachets allow
allow
allow
allow the
the
thethe
trim
trim
trim
trim to
to
to find
to
find
find
find its
its
itsits
own
own
ownown
level
level
level
level on
on
onontop
top
toptop
ofof
of the
of
the
thethefinal
final
final
final floor
floor
floor
floor finish
finish
finish
finish
22
2 To
2To
ToTo
remove,
remove,
remove,
remove, lift
lift
liftlift
out
out
outoutby
by
bybyreleasing
releasing
releasing
releasing the
the
thethe
blue
blue
blue
blue
locking
locking
locking
locking handles
handles
handles
handles

FOR
FOR
FOR SAFETY
FOR
SAFETY
SAFETY ::: All
SAFETY All
All cables
: All
cables
cables
cables exiting
exiting
exiting boxes
exiting
boxes
boxes
boxes must
mustmust
must bebe
be
be positioned
positioned
positioned
positioned into
into
into thethe
into
the
the cable
cable
cable
cable routers
routers
routers
routers onon
on
on box
box
boxbox trim
trim
trim and
trim
and
andand exit
exit
exit box
exit
box
box viavia
box
via
via cable
cable
cable outlets
cable
outlets
outlets
outlets
LidLid
Lid
Lid and
andand
and lidlid
lid
lid handle
handle
handle
handle must
mustmust
must always
always
always
always bebe
be
be placed
placedplaced
placed in the
in
in thethe
in
the closed
closed
closed
closed positions
positions
positions
positions
When
When
WhenWhenusing
using
using
using metal
metal
metal
metal lidlid
lid
lid and
andand
and trims,
trims,
trims,
trims, thethe
the
the lifting
lifting
lifting device
lifting
device
device
device at at
at
at thethe
the
the centre
centre
centre
centre of the
of
of thethe
of
the lidlid
lid
lid is not
isis notnot
is
not to be
to
to bebe
to
be used
used
used asas
used
as
as a cable
aa cable
cable exit
a cable
exit
exit
exit

Opening
Opening
Opening
Opening lid
lid to
lidlid
to
to anan
to
anan angle
angle
angle
angle of
of 30°
of 30°
of
30°30° and
and
andand lifting
lifting
lifting
lifting
upwards
upwards
upwards
upwards will
will detach
willwill
detach
detach
detach lid
lid from
lidlid
fromfrom
from trim.
trim.trim.
trim. Inserting
Inserting
Inserting
Inserting
lid
lid into
lidlid
into
into the
into
the
thetheopposite
opposite
opposite
opposite side
side side
side of
of trim
oftrim
of
trimtrimwill
will change
willwill
change
change
change
direction
direction
direction
direction of
of the
of of
thethe
the lid
lidlid
lid

Cable
Cable
Cable
Cable routers
routers
routers
routers can
can
can also
can
also
also
also be
be
beberemoved
removed
removed
removed and
and
and
and
attached
attached
attached
attached to
to opposite
to opposite
to
opposite side
opposite
side
side of
side
of trim
oftrim
of trim
trim

A)
A) Base
A)A)
Base
BaseBase can
can
cancanbe
be
bebe detached
detached
detached
detached from
fromfrom
from
mounting
mounting
mounting
mounting frame
frame
frame
frame by
by
byby releasing
releasing
releasing
releasing screws
screws
screws
screws (A)
(A)
(A)(A)
This
This
Thisenables
enables
enables the
the thebase
basebase to
to
This enables the base to be connected be
be
to beconnected
connected
connected to
to
to to
the
the under
the services and left under floor tiles forfor
theservices
services
services and
and and left
leftleft
under
under floor
floor tiles
floor
tiles for
tiles
for
protection
protection
protection
protection until
until
until the
until
the
thethecarpet,
carpet,
carpet,
carpet, lid
lid and
lidlid
andand
and trim
trimtrim
trim
are
areare
are fitted
fitted
fitted
fitted

B)
B)B)
B) Box
Box
Box Box can
can
cancan be
bebe
be screw
screw
screw
screw fitted
fitted
fitted
fitted to
to floor
to to floor
floor
floor tile
tiletile
tile
by
byby
by using
using
using
using holesholes
holes
holes (B)
(B)(B)
(B) in
in mounting
in in mounting
mounting
mounting frame
frame
frame
frame
(If
(If hole
(If (If
hole
holehole in
in tile
in in
tiletile
tile isis
is outside
is outside
outside
outside maximum
maximum
maximum
maximum tolerance
tolerance
tolerance
tolerance
Use
Use
Use Use 44
4 xxx4No.8
x No.8
No.8
No.8 25
2525
25 mm
mm
mm mm selfself
self
self tapping
tapping
tapping
tapping screws)
screws)
screws)
screws)

17

016_017_Floor_2012 v3.indd 17 21/09/2012 16:53


Power track... delivering
power to the workspace
Legrand’s Arena-Walsall power track is the ultra compact, versatile choice to supply
power in cavity floor scenarios. When used with a Soluflex cavity floor system it creates
a flexible cable management system which can adapt to changing requirements.

This compact busbar system is


available in standard, clean earth,
dual circuit and three phase versions
- all of which are quick to install
and flexible:
• Push fit connections
• Easily reconfigured
• Overall height of just 47 mm
• ASTA certified and tested
to BS EN 60439-1:1999 and
BS EN 60439-2:2000

18

Feature Pages.indd 18 21/09/2012 17:58


The Arena-Walsall power track system has much to
offer the specifier, installer and end user:
Specifier - The modular system simplifies the wiring
plan to a linear grid which is easy to design and has built
in flexibility to cope with a wide range of final end user
requirements which are often unknown at the design
stage.
Installer - The principle of a linear grid simplifies the
estimating process. The system is quick and easy to install
on site and its modular nature helps reduce wastage
associated with trunking, tray and cable.
The end user - The availability of shuttered outlets
throughout the linear grid facilitates the movement,
addition and deletion of local power supplies. This facility
is beneficial, particularly in commercial environments
which experience frequent change.

PRODUCT RANGES

STANDARD CLEAN EARTH DUAL CIRCUIT THREE PHASE


Two bar and earth 63 A Three bar and earth 63 A Five bar and earth 50 A power Four bar and earth 50 A
power track system power track system including track system incorporating power track system. Three
an independent clean earth both standard and clean earth phased bars, one neutral bar
copper bar systems within one enclosure. and earth
Tap-offs from the standard,
clean earth and dual circuit
ranges can be used

19

Feature Pages.indd 19 21/09/2012 17:58


Arena-Walsall® power track system
standard

Standard track
length
STL12

Standard feeder
unit
SFU
Standard tap-off
STO3U Standard
flexible bend
SFB 1

picto loupe-65765j.eps

Dimensions and technical information (p. 24-25)

Two bar and earth 63 A power track system Pack Cat. Nos. Flexible bends and tee units
Standard flexible bend
Pack Cat. Nos. Track lengths and feeder unit
1 SFB1 Comprises a length of 25 mm conduit
Standard track lengths with a plug-in feed at each end,
Supplied complete with hold down clamps pre-wired with 10 mm2 tri-rated cable
Recommended spacing between two clamps no Cable length = 1 metre
greater than one metre Other lengths are available to special order
Can be used as a bend or an offset
1 STL12 1·2 metres, 4 tap-offs Standard tee units
1 STL18 1·8 metres, 6 tap-offs
1 STL24 2·4 metres, 8 tap-offs Supplied with slider and
1 STL30 3·0 metres, 10 tap-offs one end cap
1 STL36 3·6 metres, 12 tap-offs
1 STU A Left feed
Standard feeder unit 1 STU B Centre feed
Supplied with one end cap to be 1 STU C Right feed
fitted to track end Standard four way
1 SFU 2 x 20/25 mm knockout entries 1 SFW Supplied complete with
Terminal capacity 16 mm2 maximum slider and two end caps

Standard tap-offs
Accessories
All tap-offs conform to Section 607 of BS 7671 : 2001
Supplied with new cable colours to 1 SHC Spare hold down clamp
BS 7671 : 2001 amendment No. 2 ‘fixed wiring’ 128

These tap-offs can also be used with the dual circuit


power track
Hanger brackets
1 STO3U 3 metres, unfused 2B
ar 1 SVB Vertical hanger bracket
STO3F 3 metres, fused
+E

1 SHB Horizontal hanger bracket


art

1
h

1 STO5F 5 metres, fused

Cle
an
art E
h

1 SEC Spare end cap

Du
al C
irc
uit

Standard power track is denoted by a


Pha
se
g le
Sin
white label with a black flash

Ex
tra
Eart
h

20

020_Floor_2012 v2.indd 20 21/09/2012 09:55


Arena-Walsall® power track system
clean earth

Clean earth
track length
CTL12

Clean earth
feeder unit
CFU
Clean earth
tap-off
Clean earth
CTO3U
flexible bend
CFB 1

picto loupe-65765j.eps

Pack Cat. Nos. Flexible bends and tee units


Dimensions and technical information (p. 24-25)
Clean earth flexible bend
Three bar and earth 63 A power track system including an independent 1 CFB1 Comprises a length of 25 mm
clean earth copper bar conduit with a plug-in feed at
each end, pre-wired with 10 mm2
tri-rated cable
Pack Cat. Nos. Track lengths and feeder unit Cable length = 1 metre
Clean earth track lengths Other lengths are available to special order
Can be used as a bend or an offset
Supplied complete with hold down clamps
Recommended spacing between two clamps no Clean earth tee units
greater than one metre Supplied with slider and
one end cap
1 CTL12 1·2 metres, 4 tap-offs
1 CTL18 1·8 metres, 6 tap-offs 1 CTU A Left feed
1 CTL24 2·4 metres, 8 tap-offs 1 CTU B Centre feed
1 CTL30 3·0 metres, 10 tap-offs 1 CTU C Right feed
1 CTL36 3·6 metres, 12 tap-offs
Clean earth four way
Clean earth feeder unit
1 CFW Supplied with slider and
Supplied with one end cap to be two end caps
fitted to track end
1 CFU 2 x 20/25 mm knockout entries
Terminal capacity 16 mm2 maximum
Accessories
Clean earth tap-offs 1 SHC Spare hold down clamp
All tap-offs conform to Section 607 of BS7671 : 2001
2B
ar
+E
art
h

Supplied with new cable colours to


BS 7671 : 2001 amendment No. 2 ‘fixed wiring’ Hanger brackets
These tap-offs can also be used 1 SVB Vertical hanger bracket
with the dual circuit power track 1 SHB Horizontal hanger bracket
Cle
an
E

CTO3U 3 metres, unfused


art

1
h

1 CTO3F 3 metres, fused


1 CTO5F 5 metres, fused

Du
1 SEC Spare end cap
al C
irc
uit

Sin
g le
Pha
se

Clean earth power track is denoted by a


white label with a red flash
Ex
tra
Eart
h

21

021_Floor_2012 v1.indd 21 21/09/2012 09:56


Arena-Walsall® power track system
dual circuit

Dual circuit
track length
DTL12

Dual circuit
feeder unit
DFU
Dual circuit
tap-off
DTO3U Dual circuit
flexible bend
DFB 1

picto loupe-65765j.eps

Dimensions and technical information (p. 24-25)

Five bar and earth 50 A power track system incorporating both standard Pack Cat. Nos. Flexible bends and tee units
and clean earth systems within one enclosure
Dual circuit flexible bend
Pack Cat. Nos. Track lengths and feeder unit 1 DFB1 Comprises a length of 25 mm
conduit with a plug-in feed at
Dual circuit track lengths each end, pre-wired with
Supplied complete with hold down clamps 10 mm2 tri-rated cable
Recommended spacing between two clamps Cable length = 1 metre
no greater than one metre Other lengths are available to special order
Can be used as a bend or an offset
1 DTL12 1·2 metres, 4 tap-offs Dual circuit tee units
1 DTL18 1·8 metres, 6 tap-offs
1 DTL24 2·4 metres, 8 tap-offs Supplied with slider
1 DTL30 3·0 metres, 10 tap-offs and one end cap
1 DTL36 3·6 metres, 12 tap-offs
1 DTU A Left feed
1 DTU B Centre feed
Dual circuit feeder unit 1 DTU C Right feed
Supplied with one end cap to be
fitted to track end Dual circuit four way
1 DFU 2 x 20/25 mm knockout entries 1 DFW Supplied with slider
Terminal capacity 16 mm2 maximum and two end caps

Dual circuit tap-offs


2B
ar
+E
ar t

Accessories
h

All tap-offs conform to Section 607 of BS 7671 : 2001


Supplied with new cable colours to 1 SHC Spare hold down clamp
BS 7671 : 2001 amendment No. 2 ‘fixed wiring’
These tap-offs must only be used
Cle
an
Ear
th

with the dual circuit power track


All tap-offs from standard and Hanger brackets
clean earth track can also be used 1 SVB Vertical hanger bracket
Dua 1 SHB Horizontal hanger bracket
1 DTO3U 3 metres, unfused
lC
ircu
it

1 DTO3F 3 metres, fused


1 DTO5F 5 metres, fused
gle
Pha
se
Sin
1 SEC Spare end cap

Ext
ra
Ear
h t

Dual circuit power track is denoted by a


white label with a black and red flash

For pre-wired floor boxes and grommets,


see p. 15

Contact us on +44 (0) 870 608 9020

22

022_Floor_2012 v1.indd 22 21/09/2012 10:02


Arena-Walsall® power track system
three phase

Single phase
track length
PTL12

Single phase
feeder unit
PFU
Single phase
tap-off
PTO3UR Three phase
flexible bend
PFB 1

picto loupe-65765j.eps

Dimensions and technical information (p. 24-25)

Four bar and earth 50 A power track system Pack Cat. Nos. Flexible bends and tee units
Three phased bars, one neutral bar and earth
Three phase flexible bend
Pack Cat. Nos. Track lengths and feeder unit 1 PFB1 Comprises a length of 25 mm
conduit with a plug-in feed at
Three phase track lengths each end, pre-wired with 10 mm2
Supplied complete with hold down clamps tri-rated cable
Recommended spacing between two clamps no Cable length = 1 metre
greater than one metre Other lengths are available to special order
Can be used as a bend or an offset
1 PTL12 1·2 metres, 4 tap-offs
1 PTL18 1·8 metres, 6 tap-offs Three phase tee units
1 PTL24 2·4 metres, 8 tap-offs Supplied with slider and
1 PTL30 3·0 metres, 10 tap-offs one end cap
1 PTL36 3·6 metres, 12 tap-offs
1 PTU A Left feed
1 PTU B Centre feed
Three phase feeder unit 1 PTU C Right feed
Supplied with one end cap to be
fitted to track end
2B
ar

Three phase four way


+E
ar t
h

1 PFU 2 x 20/25mm knockout entries 1 PFW Supplied with slider and


Terminal capacity 16 mm2 maximum two end caps
Cle
an

Tap-offs for three phase power track


Ear
th

Accessories
Single phase tap-offs
1 SHC Spare hold down clamp
All tap-offs conform to Section 607 of BS 7671 : 2001 Dua

Supplied with new cable colours to


lC
ircu
it

BS 7671 : 2001 amendment No. 2 ‘fixed wiring’ +E


2B
ar

These tap-offs must only be used Hanger brackets


ar t
h

with the 3 phase power track


Sin 1 SVB Vertical hanger bracket
SHB Horizontal hanger bracket
gle

1
Pha

1 PTO3UR 3 metres, unfused reconfigurable


se

1 PTO3FR 3 metres, fused reconfigurable th


Ear
Cle
an

1 PTO5FR 5 metres, fused reconfigurable


Three phase tap-off h
Ear
t
Ext
ra


All tap-offs conform to Section 607 of BS7671 : 2001ircu
lC
Dua
1 SEC Spare end cap
Supplied with new cable colours to
it

BS 7671 : 2001 amendment No. 2 ‘fixed wiring’


This tap-off must only be used
with the 3 phase power track Sin
gle
Pha
se

1 PTO3U 3 metres, unfused


(L1, L2 and L3 connected) Three phase power track is denoted by a
white label with a blue flash
Ext
ra
Ear
h t

For pre-wired floor boxes and grommets,


see p. 15

Contact us on +44 (0) 870 608 9020

23

023_Floor_2012 v1.indd 23 21/09/2012 10:04


Arena-Walsall® power track system
technical information

n Specification / technical data n Standards


Certification
Electrical data
Asta Certified and tested to BS EN 60439-1 : 1999 and
Rated current 63 A/50 A BS EN 60439-2 : 2000
Rated voltage 250 V/415 V Manufactured within an approved ISO 9001 : 2008 facility
Frequency 50/60 Hz IEE Wiring Regulations
Rated short circuit withstand 16 kA Legrand power track system is suitable for installation to BS7671 : 2001
Track conductor resistance – or BS 7671 : 2008
line and neutral 3 mΩ/m
Installations having high protective conductor currents (formerly
Track conductor impedance 1·43 mΩ/m
Section 607, BS7671 : 2001)
Legrand power track system allows compliance with regulation
Volt drops 543·7, BS7671 : 2008 and Section 607, BS7671 : 2001. However, this
Line and neutral : track 2·86 mV/A/m requirement must be stated at the time of order to ensure the correct
Tap-off (32 A - 4 mm2 cable) 10 mV/A/m system components are selected
Flexible bend (10 mm2 tri-rated cable) 3·7 mV/A/m
Feed unit 0·3 mV/A/m n Terminal block connections
Track connector 0·4 mV/A/m N L N L N2 L2 N1 L1

Earth fault loop


Impedance : L+N track conductors 1·5 mΩ/m
T T T
Earth track conductor 1·2 mΩ/m
Tap-off (32 A - 4 mm2 cable) 33 mΩ (3 metre L/N/E) Standard Clean earth Dual circuit
Feed unit 0·3 mΩ
The three types above are compatible and an installation can be
Track connector 0·4 mΩ downrated from the dual circuit to either standard or clean earth in
Flexible bend (10 mm2 tri-rated cable) 3·7 mΩ (1 metre L/N/E) mid-run by means of a flexible bend or direct connection
(see opposite)
Mechanical data L3 L2 N L1
Number of conductors PE + 2,3,4 and 5
Track conductor cross section area 13 mm2 T The three phase system is
Incoming cable termination capacity 16 mm2
not interchangeable
Tap-off cable 32 A unfused 4 mm2
Tap-off cable 13 A fused L/N : 2·5 mm2, E : 4 mm2 Three phase
Tap-off conduit 16 mm/20 mm diameter
Feeder conduit entry 20 mm/25 mm diameter
IP rating IP 40 (when fully
assembled) n Track length
Maximum profile height 47 mm including tap-off
Track height 17 mm

47
Material specification All dimensions in mm
Track housing Galvanised steel 17
Track conductors High conductivity copper
Track insulator Self extinguishing PVC 60
extrusion 75
Sockets, track connectors, track ends Nylon
Overall height : 47 mm with feeder unit and tap-off
Tap-off plugs Nylon
End shutters and track shutters Glass filled nylon
Tap-off / flexible bend cable LSF/PVC
Tap-off / feeder and connector pins Brass 47

17

60
75

Track Length End Cap


47
WITH
1
TAP-OFF
17

63 60
All dimensions (mm) are nominal 60
75 Simply push-fit 3e
unused ends of t
24

024_025_Floor_2012 v3.indd 24 21/09/2012 10:08


LENGTH
crop crop

125

47

crop crop

n Feeder units 283 n Tees and four ways


60
Two – 20/25 mm knockout entries Supplied complete with slider, lid, turnbuckle fasteners
Terminal capacity 16 mm2 maximum and end cap(s)
Supplied complete with terminal block, lid and turnbuckle fastener and crop crop
one end cap
125

47

Left feed tee unit Right feedcrop


tee unit crop
Component Cat. No./A Component Cat. No./C
283 Centre feed tee unit
60 Component Cat. No./B

n Flexible bends
n Tap-offs and pre-wired floor boxes
crop crop
80
Section 434.2.1 of the Wiring Regulations requires any conductor
exceeding 3 m in length to have a fault current protective device (e.g. fuse) 1 metre
at the point where current carrying capacity is reduced (tap-off plug)
All tap-offs over 3 m will be supplied with a BS 1362 13 A fuse fitted
within the plug n End cap
crop crop
If the system is to be protected by a 32 A breaker then unfused tap-offs Cat. No. SEC
exceeding 3 m may be specified at time of order
If a floor service unit, supplied by a single tap-off, contains more than 2 19
x 13 A socket outlets
43
then the total loading of the service box must not 1 metre
exceed 32 amps 63 60
Other pre-wired tap-off lengths are available on request,
contact us on +44 (0) 870 Cable
608 Length
9020- 3 or 5 metres
Unfused tap-offs are rated at 32 A
Fused tap-offs are supplied with a standard BS 1362 13 A fuse 80
n Hold down clamp
19
Each power track length is supplied
43 mm already fitted with sliding clamps 63 60
• 2 clamps on each 1·2, 1·8 and 2·4
metre length
Cable length - 3 or 5 m • 3 clamps on each 3·0 and 3·6
metre length
Tap-off length refers to the cable and not the conduit length A 128 A
The conduit is 250 mm shorter than the cable length
B B

n Tap-offs for three phase power track n Vertical hanger bracket


C
C
Single phase tap-offs Three phase tap-off Supplied in two parts complete with
clamping screws (A) A
Use one M8 Athreaded rod (B) and
four M8 nuts (C) (one above and B
B
below each bracket flange)
Recommended spacing between A
A
vertical hanger brackets is 1 metre
maximum C
C 128

n Horizontal hanger bracket A A

Supplied in two parts B B


PTO3FR / PTO5FR PTO3UR PTO3U Use two M8 threaded rods (A) and
(fused) (unfused) (unfused) four M8 nuts (B) (one above and
below each bracket flange)
Recommended spacing between
horizontal hanger brackets is
1 metre maximum

All dimensions (mm) are nominal

25

024_025_Floor_2012 v3.indd 25 21/09/2012 17:13


Soluflex ... innovation in ®

cable management flooring


Soluflex is much more than just a raised floor, it’s a quick and simple to install
cable management solution.
This innovative system integrates low-level flooring with Legrand’s market leading
cable management solutions, allowing cables for power, data and communication to be
structured in a logical, ready to use layout that remains hidden to end users.

26

Feature Pages.indd 26 21/09/2012 18:16


Perfect partners
Soluflex has been designed to integrate perfectly with
Legrand’s market leading cable management solutions
and wiring accessories...
From ultra-compact power track systems to steel wire
120mm

cable tray, and from cavity floor boxes to Arteor power and
data sockets, every solution can be installed in or under
90mm

the floor using Soluflex.


60mm

Quick and easy


37mm

installation
You don’t have to be a flooring expert to install Soluflex.
It’s simply a question of placing supports on the floor and
then clicking the durable steel tiles into place (without the

Ideal for renovation


need for glue or fixings).
Once the floor has been laid, the required cabling and
connections can be installed between the supports by Ideal for use in existing buildings, Soluflex’s non-invasive
removing the relevant tiles until cabling is complete. The installation technique avoids damaging historic floors
finished installation can then be covered with any type of and includes a specially developed, ultra low 37 mm
covering... carpet tiles, rubber, stone or wood. And if the system... the perfect lightweight solution to bring older
office layout changes, or even relocates, Soluflex can be buildings into the 21st century without compromising
reconfigured and reused. floor to ceiling height.

27

Feature Pages.indd 27 21/09/2012 17:52


Soluflex® cavity floor system
selection chart

Height Tile Support Double edge Single edge Step Step corner Ramp Earthing tile
(mm) plate plate

37 84000 10 84037 00 84000 60 84000 61 84037 22 84037 30 84037 40 84000 20

60 84000 10 84060 00 84000 60 84000 61 84060 22 84060 30 84060 40 84000 20

90 84000 10 84090 00 84000 60 84000 61 84090 22 84090 30 84090 40 84000 20

120 84000 10 84120 00 84000 60 84000 61 84120 22 84120 30 84120 40 84000 20

Height Floor box tile Floor box 3 comp. 4 comp. 3 comp. 4 comp. 3 comp. 4 comp.
(mm) lid + trim twin socket twin socket blank blank data module data module
module module module module

37 - - - - - - - -

60  84090 81 8218 21 8218 22 8218 23 8218 24 8218 25 8218 26 8218 27

90  84090 81 8218 21 8218 22 8218 23 8218 24 8218 25 8218 26 8218 27

120  84090 81 8218 21 8218 22 8218 23 8218 24 8218 25 8218 26 8218 27

(1) For use with accessory outlet tile or cable outlet tile
(2) For use with accessory outlet tile. Standard version shown. Requires back box, Cat. No. 8218 30. Other configurations available to special order.
Contact us on +44 (0) 870 608 9020

n Floor boxes with lid and trim assemblies :


Suitable for 60, 90 and 120 mm systems Specials also available, including RCD and RCBO options to
comply with 17th Edition requirements

28

028_029_Floor_2012 v4.indd 28 21/09/2012 10:12


Cable outlet Chrome outlet Accessory outlet Fixing bracket Semi-submerged Semi-submerged Fully submerged Fully submerged
tile grommet tile power unit data unit power unit data unit
2 x 240 V 2 x 2 data 2 x 240 V 2 x 2 data
(empty) (empty) (empty) (empty)

84000 30 81902 32 84000 40 84000 50  84037 50  84037 51 - -

84000 30 81902 32 84000 40 84000 50 - - 84060 72 84060 73

84000 30 81902 32 84000 40 84000 50 - - - -

84000 30 81902 32 84000 40 84000 50 - - - -

Cable snake – Cable snake – Power pole(2)


grey(1) black(1)

81906 40 81906 41 86502 10

81906 40 81906 41 86502 10

81906 40 81906 41 86502 10

81906 40 81906 41 86502 10

n Cable snake n Power pole


The cable snake creates neat, tidy work spaces by concealing Multiple configurations available to special order
cables between the floor and the desk Contact us on +44 (0) 870 608 9020
For more information, contact us on +44 (0) 870 608 9020

29

028_029_Floor_2012 v4.indd 29 21/09/2012 16:35


Soluflex®
ultra low cavity floor system

Accessory outlet tile


Cable outlet tile
8400040
8400030

Step
8406022
Step corner
8406030 Floor box tile
8409081
Support Ramp
8406000 8406040

Selection chart (p. 28-29)


Installation instructions (p. 33)
Dimensions (p. 34-35)

Cable management floor system


225 x 225 mm tiles manufactured from pre-galavanised steel with
13 mm return
Integrated earthing design
Click fit, no fixings required
Support manufactured from recycled polypropylene

Pack Cat. Nos. Floor components Pack Cat. Nos. Floor components (continued)
Tile Step corner
1 8400010 225 x 225 mm floor tile Width 900 mm
Height
Floor supports (mm)
1 8403730 37
1 8403700 3 7 mm height 1 8406030 60
(35 mm support – 37 mm inc. tile) 1 8409030 90
1 8406000 60 mm height 1 8412030 120
(58 mm support – 60 mm inc. tile)
1 8409000 90 mm height Ramp
(88 mm support – 90 mm inc. tile)
1 8412000 120 mm height 10% incline
(118 mm support – 120 mm inc. tile) Height Length Width
(mm) (mm) (mm)
Earthing tile 1 8403740 37 400 112
1 8406040 60 616 112
1 8400020 2
25 x 225 mm 1 8409040 90 898 112
Earthing clamp 6 mm2 (max.) 1 8412040 120 1 181 112
1 earthing tile per 100 mm2
Edge plates
Used to finish installation against wall
Trim to size on site
1 8400060 900 x 300 mm double edge plate
1 8400061 900 x 300 mm single edge plate

Step
Width 900 mm
Height
(mm)
1 8403722 37
1 8406022 60
1 8409022 90
1 8412022 120

30

030_031_Floor_2012 v8.indd 30 21/09/2012 10:17


Soluflex®
ultra low cavity floor system (continued)

Accessory outlet tile


Cable outlet tile
8400040
8400030

Step
8406022
Step corner
8406030 Floor box tile
8409081
Support Ramp
8406000 8406040

Selection chart (p. 28-29)


Installation instructions (p. 33)
Dimensions (p. 34-35)

Cable management floor system


225 x 225 mm tiles manufactured from pre-galavanised steel with
13 mm return
Integrated earthing design
Click fit, no fixings required
Support manufactured from recycled polypropylene

Pack Cat. Nos. F


loor box for 60, 90 and 120 mm high Pack Cat. Nos. Universal outlets
systems only
Accessory outlet tile
Floor box
1 8400040 2
25 x 225 mm
1 8409081 450 x 450 mm floor box tile Used to fix power poles,
cable snake or grommets

1 821821 Floor box lid and trim


Aluminium power pole

Outlet plate options 1 8650210 670 mm high


1 821830 Single power pole back box
1 821822 3 compartment twin switched
socket module
1 821824 3 compartment blank module
1 821826 3 compartment data module
(4 x 37 x 22 mm cut-outs)
1 821823 4 compartment twin switched 1 8400050 Accessory outlet tile fixing bracket
socket module
1 821825 4 compartment blank module
1 821827 4 compartment data module
(4 x 37 x 22 mm cut-outs)
Accessories
Outlet solutions for 37 mm high systems 1 8190232 Chrome outlet grommet

Semi-submerged
1 8190640 Grey cable snake
1 8403750 3 7 mm power outlet to accept
2 x Arteor double modules(1) 1 8190641 Black cable snake
1 8403751 37 mm data outlet to accept
2 x Arteor double modules(1)

1 8400030 Cable outlet tile

Outlet solutions for 60 mm high systems


Fully submerged
1 8406072 6 0 mm power outlet to accept
2 x Arteor double modules(1)
1 8406073 60 mm data outlet to accept
2 x Arteor double modules(1)

(1) For Arteor modules, refer to the latest


Wiring Devices catalogue

31

030_031_Floor_2012 v8.indd 31 21/09/2012 16:36


Soluflex® cavity floor system
technical information

n Specification / technical data n Safety


Construction • Safety against short circuits : Soluflex is earthed (as long as 1 earthing
The Soluflex cable floor system is constructed of a raised floor of tile is installed per 100 m2)
tiles and supports with integrated cabling and connection points for
• Fire resistance : due to its low plenum height Soluflex is
telecoms, power and data
self-extinguishing
Tested according to BS EN 13501-1, class B(fl)S1-d0
Materials
• The tiles are manufactured from pre-galvanised sheet steel in
Other characteristics
accordance with BS EN 10326
The Soluflex cable floor system feels extremely solid. Since the system
• The supports are made of polypropylene. Inflammability class B2
is not adjustable in height, it needs no later adjustment
according to DIN 4102
The grid layout of the system means the cables are perfectly parallel,
and you can cross data cables at the required angle of 90°
Weights and measures
• Dimensions of tiles : 225 x 225 mm n TNO-fire
• 4 different heights : 37 mm, 60 mm, 90 mm, 120 mm
Fire propagation
Other heights available on request Its low plenum height enables the cable floor system to be
• Weight of the Soluflex cable floor system : approx. 20 kg per m2 self-extinguishing

n Load bearing data NEN-EN 13501-1


• Point load per tile/support : 1 500 Newton/25 mm2 B(fl) S1-d0
• Equal divided load of 3 000 kg per m2
• Minimum safety factor : V = 1·71 NEN 1775 :
A – Inflammability – complies with the class
n Sound measurements T1 criteria for inflammability
The sound measurements have been carried out in the laboratory B – Horizontal fire propagation : all heights
of consultancy firm Peutz & Associes. The complete report can be maximum horizontal fire propagation = 0 cm, which implies a
obtained from our sales department critical density of heat flow of more than 11 kW/m2
Classification according to NEN 1775 : Class T1
Acoustic
• Flanking airborne sound insulation in accordance with NEN 6066 :
ISO 717-1 : 1996 With (highest) heat flow supply of 50 kW/m2 :
Tested according to ISO 140-12 : 2000 (highest) normative smoke density smaller than 0·5 m-1, which is very
Soluflex cable floor system + carpet tiles, without mineral wool little smoke production in case of fire
underneath the partition wall : Dn,f,w = 48 dB
DIN 4102 :
Soluflex cable floor system + carpet tiles, with mineral wool
underneath the partition wall : Dn,f,w = 48 dB Resistance to fire in accordance with DIN 4102 Class B1
• Flanking impact sound insulation in accordance with n Level floor
ISO 717-2 : 1996
Tested in accordance to ISO 140-12 : 2000 The sub-floor must be dry, clean and level,
suitable for laying carpet. If the floor is not level, it must be levelled
Soluflex cable floor system + carpet tiles, without mineral wool
before you start to install the Soluflex cable floor system. Please
underneath the partition wall : Ln,f,w = 49 dB
contact your floor specialist for professional advice
Soluflex cable floor system + carpet tiles, with mineral wool
underneath the partition wall : Ln,f,w = 39 dB
• Vertical impact sound insulation improvement in accordance n KEMA-certificate
with ISO 717-2 : 1996 Soluflex cable floor system has been
Tested in accordance with ISO 140-8 : 1978 certified by KEMA and meets the
requirements for mechanical and
Concrete floor 140 mm + Soluflex
electrical safety
rLw = 17 dB rllin = 7 dB
Concrete floor 140 mm + Soluflex + carpet tiles Earthing
rLw = 24 dB rllin = 12 dB The cable floor system is
automatically earthed, provided that
Tested to : PSA MOB PF2PS/SPU 1 earthing tile is installed per 100
BS EN 12825 : 2001 m2. Install an earthing tile every 14 m
length in gangways
Working load : 1·9kN

Ultimate Deflection Safety Class of


load above under factor tolerance in
12kN working manufacture
load

1 A 3 1

Working load : 2·9kN


Ultimate Deflection Safety Class of
load above under factor tolerance in
12kN working manufacture
load

1 B 2 1

32

032_Floor_2012 v1.indd 32 21/09/2012 10:21


Soluflex® cavity floor system
general installation instructions

n Installing the Soluflex cable floor system Ramp

• Start with a dry, clean and level sub-floor that is suitable


for laying normal carpet. If the floor does not meet these
requirements, level it first

• Start in the corner of the room and click the tiles into the
plastic supports. Leave a 10 mm gap between the wall and
Cable routes
tile to allow for expansion. Continue to build the floor like this
and cut fitting tiles or edge plates to size

• You are now ready to open the cable routes using your
cabling plan. Make sure that the cables are not placed under
proposed locations of filing cabinets or other furniture as this
limits flexibility

• The corners of the tiles have small recesses to enable them Completed Soluflex installation
to be lifted using a screwdriver. Once one tile has been
removed, the others can be removed by hand

• Now place the power track or cables into the cable routes,
taking into account any extra cabling requirements for future
flexibility

• By installing more outlet boxes you will be able to create Finished example with carpet tiles
extra connections without interruption later

• Dependent on the floor height being installed, a choice can


be made from various (pre-wired) outlet units in or on the
cable floor

• Earth the cable floor system every 100 m2 by means of an


earthing tile

• In stretched areas such as corridors, place an earthing tile at


least every 14 metres

• The electrical installation should always be carried out by a


qualified electrician in conjunction with the requirements of
the latest wiring regulations

• To create ‘islands’, install steps with step corners to ensure a


neat finishing of the system

• The ramp provides a constant transition from an existing floor


to the Soluflex cable floor system

• The entire system can easily be dismounted and installed


again as required, giving Soluflex a virtually unlimited life

• The finished installation can then be covered with rubber,


stone, wood or carpet tiles

• Finishing with carpet tiles is advised for true flexibility and


accessibility of the system

33

033_Floor_2012.indd 33 21/09/2012 10:22


Soluflex® cavity floor system dimensions
37 mm, 60 mm, 90 mm, 120 mm height

n Dimensions (mm) Step corner


Tile For 37 mm height For 60 mm height

Cat. No. 8400010

Supports Cat. No. 8403730 Cat. No. 8406030


For 37 mm height For 60 mm height
For 90 mm height For 120 mm height

Cat. No. 8403700 Cat. No. 8406000


For 90 mm height For 120 mm height Cat. No. 8409030 Cat. No. 8412030

Ramp
For 37 mm height
13
37

Cat. No. 8409000 Cat. No. 8412000 400


112 13

Double edge plate


37

400

Cat. No. 8403740


37 112
60 13
13

For 60 mm height
13 13

400
Cat. No. 8400060 616
112 37

400
60
112112

616
13
13
112
60 9060
13

Single edge plate 616


Cat. No. 8406040
13

898
616
112 112
90

For 90 mm height
112

898
13

Cat. No. 8400061


13
13
90
112

898
13120
90

Cat. No. 8409040


898
1181
112
120

Steps
112

For 37 mm height For 60 mm height


13

1181
For 120 mm height
13
120
112
120

1181

1181
112

Cat. No. 8412040


112

Cat. No. 8403722 Cat. No. 8406022

For 90 mm height For 120 mm height

Cat. No. 8409022 Cat. No. 8412022

All dimensions (mm) are nominal

34

034_035_Floor_2012 v3.indd 34 21/09/2012 10:24


Soluflex® cavity floor system dimensions
37 mm, 60 mm, 90 mm, 120 mm height (continued)

Dimensions (mm)
Earthing tile Semi-submerged unit
For 37 mm range only

Cat. No. 8400020

Cat. Nos. 8403750 Power


8403751 Data
Cable outlet tile

Cat. No. 8400030 Fully submerged power unit 2 x 240 V (empty)


For 60 mm range only

Chrome outlet grommet


Cat. No. 8406072
Cat. No. 8190232

Accessory outlet tile

Fully submerged data unit 2 x 2 data (empty)


For 60 mm range only
Cat. No. 8400040

Cat. No. 8406073


Fixing bracket

Cat. No. 8400050

Floor box tile


For 60 mm, 90 mm, 120 mm ranges only
Cat. No. 8409081

All dimensions (mm) are nominal

35

034_035_Floor_2012 v3.indd 35 21/09/2012 10:24


NEW floor systems...
making the right choice
simple
With a large choice of flush and in-screed solutions available in a variety of sizes,
Legrand has all your cable management floor system requirements covered.

All outlet systems are


designed to accept a wide
range of mix and match lids
and trims.
Bespoke metal trims are
available in any RAL reference
to suit a building’s design
scheme.

36

036_037_Floor_2012.indd 36 21/09/2012 18:45


PRODUCT RANGES

NEW NEW NEW

FLUSH FLOOR TRUNKING SHALLOW FLUSH FLOOR TRUNKING UNDERFLOOR DUCT


• Commercial floor trunking system • Commercial floor trunking system • Commercial floor ducting system
• Ideal for distributing power, data and • Designed to distribute power, data and • Ducting is installed under the screed
communication in any commercial communication where the amount of providing a strong yet cost effective
environment screed that can be removed is limited solution
• Can be used if service outlets are • Can be used if service outlets are • Positions of service outlet and junction
required required boxes are fixed prior to installation
• Cables can be accessed after • Cables can be accessed after • Service outlet and junction boxes are
installation has been completed installation has been completed height adjustable to finish flush with
• Floor boxes can be positioned at any screed
point along the trunking and removed
and repositioned at a later date

FLUSH LID FLOOR TRUNKING RECESSED LID FLOOR TRUNKING CHEQUER PLATE FLOOR TRUNKING
• Commercial floor trunking system • Commercial floor trunking system • Industrial floor trunking system
• Floor finish is fitted over the flush lid • Floor finish is fitted recessed into the • Outward return flange for added
giving a neat finish trunking lid strength
• Available in a wide range of sizes • Suitable for use in environments where • Suitable for floors that are subjected to
• Suitable for long runs of cable where no access to cables may be required at a heavy loads, for example warehouses
outlets are required later date, for example hospitals

37

036_037_Floor_2012.indd 37 21/09/2012 19:04


screed floor service outlet boxes NEW
selection chart

No. of compartments
Floor box base
Service outlet flush floor trunking
Shallow flush floor trunking 150 x 25 mm – 2 compartment
Shallow flush floor trunking 150 x 38 mm – 2 compartment
Shallow flush floor trunking 150 x 25 mm – 3 compartment
Shallow flush floor trunking 150 x 38 mm – 3 compartment
System type Shallow flush floor trunking 225 x 25 mm – 3 compartment
Shallow flush floor trunking 225 x 38 mm – 3 compartment
Screed floor box to suit shallow 25 mm ducting
Screed floor box to suit deep 38 mm ducting
Screed floor box to suit 20 mm conduit
Screed floor box to suit 25 mm conduit
Socket plates
13 A twin switched socket plate
13 A twin unswitched socket plate
13 A standard 13 A twin switched clean earth socket plate
13 A triple unswitched socket plate
13 A triple unswitched clean earth socket plate
13 A twin NS switched socket plate
13 A non-standard 13 A twin NS unswitched socket plate
13 A twin NS switched clean earth socket plate
2 gang RCD socket plate(1)
RCD
2 gang RCD socket plate - clean earth(1)
37 x 22 mm – 2 cut-out plate
37 x 22 mm – 4 cut-out plate
Data 37 x 22 mm – 4 cut-out wave plate(1)
37 x 22 mm – 6 cut-out plate
47·5 x 23·5 mm – 4 cut-out plate
2 x standard single outlet 60·3 mm
Standard 2 gang outlet plate 120·6 mm
50 x 50 mm – 1 cut-out plate
General 50 x 50 mm – 2 cut-out plate
Blank plate
58 x 53·5 mm – 1 cut-out plate to accept Arteor mounting frame(2)
58 x 53·5 mm – 2 cut-out plate to accept 2 x Arteor mounting frames(2)
Lids and trims
ABS with carpet trim – 6 mm recess
Combination with edge trim – 6 mm recess
Metal, powder coated with carpet trim – 6 mm recess
Metal, powder coated with edge trim – 10 mm recess
Stainless steel with carpet trim – 6 mm recess
Stainless steel with edge trim – 10 mm recess
Brass with carpet trim – 6 mm recess
Brass with edge trim – 10 mm recess
(1) Due to overall depth, these items will NOT fit in the flush floor and shallow flush floor ranges (Cat. Nos. FFO and AFS). When using with underfloor duct systems
(Cat. No. AFU) the outlet box must be raised by 8 mm from the lowest point to allow for wiring
38 (2) For Arteor mounting frames, refer to the latest Wiring Devices catalogue

038_039_Floor_2012 v5.indd 38 21/09/2012 16:39


1 compartment 2 compartment 3 compartment 4 compartment

– – FFO3BB FFO4BB
– AFS2BB261 – AFS4BB261
– AFS2BB265 – AFS4BB265
– – AFS3BB361 AFS4BB361
– – AFS3BB365 AFS4BB365
– – AFS3BB391 AFS4BB391
– – AFS3BB395 AFS4BB395
– AFU2BB78 AFU3BB78 AFU4BB78
– AFU2BB90 AFU3BB90 AFU4BB90
AFU1CON78 AFU2CON78 AFU3CON78 AFU4CON78
AFU1CON90 AFU2CON90 AFU3CON90 AFU4CON90

SP3201 SP3201 SP3201 SP4201


SP3200 SP3200 SP3200 SP4200
SP3211 SP3211 SP3211 SP4211
SP3300 SP3300 SP3300 SP4300
SP3310 SP3310 SP3310 SP4310
SP3221 SP3221 SP3221 SP4221
SP3220 SP3220 SP3220 SP4220
SP3231 SP3231 SP3231 SP4231
SP3202 SP3202 SP3202 SP4202
SP3212 SP3212 SP3212 SP4212
SP3203 SP3203 SP3203 SP4203
SP3403 SP3403 SP3403 SP4403
SP3404 SP3404 SP3404 SP4404
SP3603 SP3603 SP3603 SP4603
SP3408 SP3408 SP3408 SP4408
SP3205 SP3205 SP3205 –
SP3105 SP3105 SP3105 –
SP3106 SP3106 SP3106 SP4106
SP3206 SP3206 SP3206 SP4206
SP3000 SP3000 SP3000 SP4000
SP3107 SP3107 SP3107 SP4107
SP3207 SP3207 SP3207 SP4207

– FBL2ABS FBL3ABS FBL3ABS


– FBL2COM FBL3COM FBL3COM
FBL1MCT FBL2MCT FBL3MCT FBL3MCT
FBL1MET FBL2MET FBL3MET FBL3MET
FBL1SCT FBL2SCT FBL3SCT FBL3SCT
FBL1SET FBL2SET FBL3SET FBL3SET
FBL1BCT FBL2BCT FBL3BCT FBL3BCT
FBL1BET FBL2BET FBL3BET FBL3BET

39

038_039_Floor_2012 v5.indd 39 21/09/2012 12:36


commercial floor trunking systems NEW
service outlet flush floor trunking

Trunking length
FFO332

picto loupe-65765j.eps

Dimensions and technical information (p. 46)


Screed floor outlet boxes selection chart (p. 38-39)
Installation details (p. 49)
Body and lid manufactured from pre-galvanised sheet steel to BS EN 10142 and 3
Standard lengths : trunking 2·0 m, lid 0·5 m
Standard lid thickness : 2·5 mm
Each 2 m length is fitted with 4 x 500 mm long lids and supplied complete with all necessary connectors and screws
Trunking to floor fixings not supplied
A service outlet floor box can be fitted at each lid position

Pack Cat. Nos. Flush floor trunking Pack Cat. Nos. Flush floor trunking (continued)
Trunking length – 2 m End cap
3 comp 4 comp 1 FFO3312 370 x 65 mm
1 FFO332 FFO342 370 x 65 mm
Junction box

Spare connector set Supplied with connections and plates


Can be configured as a fourway,
1 FFO330 370 x 65 mm – tee, bend or straight through
spare connector set connector box
3 comp 4 comp
1 FFO3313 FFO3413 370 x 65 mm
90° riser bend
Supplied with screeding cover
Provides conduit entry with
20 mm knockouts
3 comp 4 comp
1 FFO3311 FFO3411 370 x 65 mm Service outlet base boxes
Service outlet base boxes are supplied
Back entry skirting adaptor fitted into a 500 mm long cover
3 comp 4 comp
To complete the system, the outlet base
1 FFOS3SK6 FFOS4SK6 370 x 65 – box requires outlet plates, lid and trim
150 mm high skirting Outlet plates, lids and trims ordered
1 FFOS3SK8 FFOS4SK8 370 x 65 – separately, (see p. 44)
200 mm high skirting 3 comp 4 comp
1 FFO3BB FFO4BB
Cable trunking adaptor
3 comp 4 comp
1 FFOT332T FFOT342T 370 x 65 mm
To complete the Cat. No. specify :
T = standard cable trunking Cat. No.
Example : FFOT 332 MGR623C

Flush floor trunking can be supplied All trims for service outlet boxes can be
in widths and depths greater than ABS, stainless steel, brass or powder
370 x 65 mm to special order coated any colour

Contact us on +44 (0) 870 608 9020 See p. 44

40

040_Floor_2012 v5.indd 40 21/09/2012 16:42


commercial floor trunking systems NEW
shallow flush floor trunking

Trunking length

AFS361

picto loupe-65765j.eps

Dimensions and technical information (p. 47)


Screed floor outlet boxes selection chart (p. 38-39)
Installation details (p. 49)
Body and lid manufactured from pre-galvanised sheet steel to BS EN 10142 and 3
Standard lengths : trunking 2.0 m, lid 0.5 m
Standard lid thickness : 2.5 mm
Each 2 m length is fitted with 4 x 500 mm long lids and supplied complete with all necessary connectors and screws

Pack Cat. Nos. Shallow flush floor trunking Pack Cat. Nos. Shallow flush floor trunking
(continued)
Trunking length – 2 m
2 comp 3 comp End cap
1 AFS261 AFS361 150 x 25 mm
1 AFS265 AFS365 150 x 38 mm 1 AFS2615 150 x 25 mm
1 AFS391 225 x 25 mm 1 AFS2655 150 x 38 mm
1 AFS395 225 x 38 mm 1 AFS3915 225 x 25 mm
1 AFS3955 225 x 38 mm
Spare connector set Junction box
1 AFS3611 150 mm wide Supplied with connections and plates
1 AFS3911 225 mm wide Can be configured as a fourway, tee,
bend or straight through connector box
2 comp 3 comp
90° riser bend 1 AFS2614 AFS3614 150 x 25 mm
1 AFS2654 AFS3654 150 x 38 mm
Supplied with screeding cover 1 AFS3914 225 x 25 mm
Provides conduit entry with 1 AFS3954 225 x 38 mm
20 mm knockouts
2 comp 3 comp
1 AFS2613 AFS3613 150 x 25 mm
1 AFS2653 AFS3653 150 x 38 mm Service outlet base boxes
1 AFS3913 225 x 25 mm Service outlet base boxes are supplied
1 AFS3953 225 x 38 mm empty
Back entry skirting adaptor Service outlet boxes are 65 mm deep
Due to shallow depth of trunking, box
1 AFSS FSKS To complete the Cat. No. specify : locations need to be defined and
F = shallow flush floor recessed locally before installation
trunking size code To complete the system, the outlet base
S = skirting trunking depth box requires outlet plates, lid and trim
in inches Outlet plates, lids and trims ordered
Example : AFSS 361 SK6 separately, (see p. 44)
2 comp 3 comp
1 AFS2BB261 AFS3BB361 To suit 150 x 25 mm trunking
Cable trunking adaptor 1 AFS2BB265 AFS3BB365 To suit 150 x 38 mm trunking
1 AFS3BB391 To suit 225 x 25 mm trunking
Supplied with turnbuckle fix lid 1 AFS3BB395 To suit 225 x 38 mm trunking
1 AFST F T To complete the Cat. No. specify :
F = shallow flush floor trunking size code
T = standard cable trunking
Cat. No.
Example : AFST 361 MGR623C
4 comp
1 AFS4BB261 To suit 150 x 25 mm trunking
1 AFS4BB265 To suit 150 x 38 mm trunking
1 AFS4BB361 To suit 150 x 25 mm trunking
1 AFS4BB365 To suit 150 x 38 mm trunking
1 AFS4BB391 To suit 225 x 25 mm trunking
Shallow flush floor trunking can be 1 AFS4BB395 To suit 225 x 38 mm trunking
supplied in different widths and depths

Contact us on +44 (0) 870 608 9020

41

041_Floor_2012 v5.indd 41 21/09/2012 17:57


commercial floor trunking systems
underfloor duct

Duct length
AFU391
Cable trunking
adaptor
AFUTFT
90° riser bend
AFU3918

Junction box
AFU3917

picto loupe-65765j.eps

Dimensions and technical information (p. 47)


Screed floor outlet boxes selection chart (p. 38-39)
Installation details (p. 49)
Body and lid manufactured from pre-galvanised sheet steel to
BS EN 10142 and 3
Standard length : 2·0 m. Standard lid thickness : 1·0 mm
Each 2 m length is supplied with 2 saddle clamps and screws
Duct to floor fixings are not supplied

Pack Cat. Nos. Underfloor duct Pack Cat. Nos. Underfloor duct (continued)
Duct length – 2 m End cap
2 comp 3 comp 1 AFU2615 150 x 25 mm
1 AFU261 AFU361 150 x 25 mm 1 AFU2655 150 x 38 mm
1 AFU265 AFU365 150 x 38 mm 1 AFU3915 225 x 25 mm
1 AFU391 225 x 25 mm 1 AFU3955 225 x 38 mm
1 AFU395 225 x 38 mm 1 AFU3115 300 x 25 mm
1 AFU311 300 x 25 mm 1 AFU3155 300 x 38 mm
1 AFU315 300 x 38 mm
Junction box
Spare saddle clamp an be configured as a fourway, tee, bend
C
1 AFU2612 150 x 25 mm or straight through connector box
1 AFU2652 150 x 38 mm When using with a conduit system, select
1 AFU3912 225 x 25 mm junction box depending on conduit size
1 AFU3952 225 x 38 mm For 20 mm conduit use junction box that
1 AFU3112 300 x 25 mm would suit a 25 mm ducting
1 AFU3152 300 x 38 mm For 25 mm conduit use junction box that
would suit a 38 mm ducting
90° flat bend
2 comp 3 comp To suit screed 63 mm to 78 mm deep
2 comp 3 comp 1 AFU2617 AFU3617 150 x 25 mm
1 AFU2613 AFU3613 150 x 25 mm 1 AFU3917 225 x 25 mm
1 AFU2653 AFU3653 150 x 38 mm 1 AFU3117 300 x 25 mm
1 AFU3913 225 x 25 mm
1 AFU3953 225 x 38 mm
1 AFU3113 300 x 25 mm
1 AFU3153 300 x 38 mm
90° riser bend To suit screed 75 mm to 90 mm deep
upplied with screeding cover
S 1 AFU2656 AFU3656 150 x 38 mm
Provides conduit entry with 1 AFU3956 225 x 38 mm
20 mm knockouts 1 AFU3156 300 x 38 mm
2 comp 3 comp
1 AFU2618 AFU3618 150 x 25 mm
1 AFU2654 AFU3654 150 x 38 mm
1 AFU3918 225 x 25 mm
1 AFU3954 225 x 38 mm
1 AFU3118 300 x 25 mm
1 AFU3154 300 x 38 mm
Back entry skirting adaptor
1 AFUS F SK S o complete the Cat. No. specify :
T
F = underfloor duct size code
S = skirting trunking depth
in inches (either 6 or 8)
Example : AFUS 391 SK6
Cable trunking adaptor
Supplied with turnbuckle fix lid
1 AFUT F T To complete the Cat. No. specify :
F = underfloor duct size code Underfloor duct can be supplied in
T = standard cable trunking
Cat. No. other widths, depths and compartment
Example : AFUT 395 MGR623C configurations to special order

Contact us on +44 (0) 870 608 9020

42

042_043_Floor_2012 v5.indd 42 21/09/2012 13:05


commercial floor trunking systems NEW pedestal units
underfloor duct (continued)

Service outlet box


2 compartment Service outlet box
3 compartment
AFU2BB78
AFU3BB78 PED2WHI

picto loupe-65765j.eps picto loupe-65765j.eps

PED3WHI PED8WHI

Dimensions and technical information (p. 47)


Screed floor outlet boxes selection chart (p. 38-39) Dimensions and technical information (p. 50)
Installation details (p. 49)
Body and lid manufactured from pre-galvanised sheet steel to Material : zinc coated mild steel to BS EN 10152
BS EN 10142 and 3 Colour : white epoxy powder coated, RAL 9003. For other colours,
Standard length : 2·0 m. Standard lid thickness : 1·0 mm please specify RAL number
Each 2 m length is supplied with 2 saddle clamps and screws Zintec finish is available on request (Zintec pedestal units are to be
Duct to floor fixings are not supplied painted on site)

Pack Cat. Nos. In-screed service outlet base boxes Pack Cat. Nos. Pedestal units
Service outlet base boxes are supplied 1 PED1WHI Single socket
empty
To complete the system, the outlet base
box requires outlet plates, lid and trim
Outlet plates, lids and trims ordered 1 PED2WHI Twin socket
separately, (see p. 44)
Use a 2 or 4 compartment service outlet
box with 2 compartment duct
2 compartment box can only be used with
150 and 225 mm wide ducting
To fit 25 mm deep ducting
1 PED3WHI Back-to-back single sockets
To suit screed 63 mm to 78 mm deep
1 AFU2BB78 2 compartment to suit
25 mm shallow ducting
1 AFU3BB78 3 compartment to suit
25 mm shallow ducting
1 AFU4BB78 4 compartment to suit
25 mm shallow ducting
1 PED4WHI Back-to-back twin sockets
To fit 38 mm deep ducting
To suit screed 75 mm to 90 mm deep
1 AFU2BB90 2 compartment box to suit
38 mm deep ducting 1 PED8WHI Pyramid box
1 AFU3BB90 3 compartment box to suit
38 mm deep ducting
1 AFU4BB90 4 compartment box to suit
38 mm deep ducting

20 mm conduit fed
To suit screed 63 mm to 78 mm deep
1 AFU1CON78 1 compartment box to suit
20 mm conduit
1 AFU2CON78 2 compartment box to suit
20 mm conduit
1 AFU3CON78 3 compartment box to suit
20 mm conduit
1 AFU4CON78 4 compartment box to suit
20 mm conduit

25 mm conduit fed
To suit screed 75 mm to 90 mm deep
1 AFU1CON90 1 compartment box to suit
25 mm conduit
1 AFU2CON90 2 compartment box to suit
25 mm conduit
1 AFU3CON90 3 compartment box to suit Pedestal units are available in other
25 mm conduit
1 AFU4CON90 4 compartment box to suit dimensions and finishes to special order
25 mm conduit

Contact us on +44 (0) 870 608 9020

43

042_043_Floor_2012 v5.indd 43 21/09/2012 18:40


outlet plates for floor trunking NEW lids and trims for floor trunking NEW
power and data

picto loupe-65765j.eps picto loupe-65765j.eps

Screed floor outlet boxes selection chart (p. 38-39) Screed floor outlet boxes selection chart (p. 38-39)
Installation details (p. 17) Installation details (p. 17)

Plates to fit 1, 2 and 3 compartment boxes are all 100 mm wide Moulded lids and trims are manufactured from durable ABS and feature a
4 compartment plates are 75 mm wide quick fit / release ratchet system
Non-standard sockets have a round earth pin Carpet trim versions are supplied with a 6 mm carpet recess
Due to overall depth, RCD sockets and wave type data plates will NOT Edge trim versions are supplied with a 10 mm recess
fit in the flush floor and shallow flush floor ranges (Cat. Nos. FFO/AFS). Metal trim versions are powder coated grey RAL7024 matt as standard
When using with underfloor duct systems (Cat. No. AFU) the outlet box Stainless steel is satin finish as standard
must be raised by 8 mm from the lowest point to allow for wiring Brass is polished finish as standard
Pack Cat. Nos. Power and data plates Pack Cat. Nos. Floor box lids and trims
1, 2, 3 comp. 4 comp. 1 and 2 compartment
100 mm wide 75 mm wide 1 comp. 2 comp.
13 A standard socket plates Carpet trim
1 SP3201 SP4201 Twin switched 1 – FBL2ABS BS
A
1 SP3200 SP4200 Twin unswitched 1 FBL1MCT FBL2MCT Metal – grey
1 SP3211 SP4211 Twin switched 1 FBL1SCT FBL2SCT Stainless steel
clean earth 1 FBL1BCT FBL2BCT Brass
1 SP3300 SP4300 Triple unswitched
1 SP3310 SP4310 Triple unswitched
clean earth Edge trim
13 A non-standard socket plates 1 – FBL2COM ABS lid/metal trim – ABS/grey
1 FBL1MET FBL2MET Metal – grey
1 SP3221 SP4221 Twin NS switched 1 FBL1SET FBL2SET Stainless steel
1 SP3220 SP4220 T win NS unswitched 1 FBL1BET FBL2BET Brass
1 SP3231 SP4231 Twin NS switched
clean earth

RCD socket plates


3 and 4 compartment
1 SP3202 SP4202 2 gang
1 SP3212 SP4212 2 gang – clean earth Carpet trim
1 FBL3ABS ABS
1 FBL3MCT Metal – grey
Data plates 1 FBL3SCT Stainless steel
1 SP3203 SP4203 37 x 22 mm – 2 cut-outs 1 FBL3BCT Brass
1 SP3403 SP4403 3 7 x 22 mm – 4 cut-outs Edge trim
1 SP3404 SP4404 37 x 22 mm – 4 cut-outs 1 FBL3COM ABS lid/metal trim – ABS/grey
(wave plate) 1 FBL3MET Metal – grey
1 SP3603 SP4603 37 x 22 mm – 6 cut-outs 1 FBL3SET Stainless steel
1 SP3408 SP4408 47·5 x 23·5 mm – 4 cut-outs 1 FBL3BET Brass

General
1 SP3205 -
2 x standard single outlet 60·3 mm
1 SP3105 - Standard 2 gang
outlet plate 120·6 mm
1 SP3106 SP4106 50 x 50 mm –
1 cut-out plate
1 SP3206 SP4206 50 x 50 mm –
2 cut-out plate
1 SP3000 SP4000 Blank plate
1 SP3107 SP4107 58 x 53·5 mm – 1 cut-out
plate to accept Arteor
mounting frame (Cat. No. 576016)(1)
1 SP3207 SP4207 58 x 53·5 mm – 2 cut-outs plate to accept
2 x Arteor mounting frames Metal lids and trims can be powder coated
(Cat. No. 576016)(1) to any RAL reference. Other options, such as
Fasteners lockable lids, are available to special order
50 SPSCREW M3·5 x 6 spare socket plate screws
Contact us on +44 (0) 870 608 9020
(1) For Arteor mounting frames, refer to the latest
Wiring Devices catalogue

44

044_Floor_2012 v5.indd 44 21/09/2012 13:40


commercial floor trunking systems commercial floor trunking systems
flush lid floor trunking recessed lid floor trunking

Trunking length
FF63

Trunking length
FRFI63

picto loupe-65765j.eps picto loupe-65765j.eps

Dimensions and technical information (p. 48) Dimensions and technical information (p. 48)
Installation details (p. 49) Installation details (p. 49)

Body and lid manufactured from pre-galvanised sheet steel to Body and lid manufactured from pre-galvanised sheet steel to
BS EN 10142 and 3 BS EN 10142 and 3
Standard length : 2·0 m Standard length : 2·0 m
Standard lid thickness : 2·5 mm Standard lid thickness : 2·5 mm
Supplied complete with all necessary connectors and screws Lid recess : 3·5 mm
Internal dividers are fitted on all trunking lengths 225 mm and above Supplied complete with all necessary connectors and screws
to provide lid support Internal dividers are fitted on all trunking lengths 225 mm and above
Service outlet boxes are not available for this range to provide lid support
Service outlet boxes are not available for this range
Pack Cat. Nos. Flush lid floor trunking
Pack Cat. Nos. Recessed lid floor trunking
Trunking length – 2 m
Trunking length – 2 m
1 FF42 100 x 50 mm
1 FF63 150 x 75 mm 1 FRL42 100 x 50 mm
1 FF124 300 x 100 mm 1 FRL63 150 x 75 mm
1 FRL124 300 x 100 mm
90° riser bend
90° riser bend
Supplied with screeding cover
Provides conduit entry with Supplied with screeding cover
20 mm knockouts Provides conduit entry with
20 mm knockouts
1 FFRB42 100 x 50 mm
1 FFRB63 150 x 75 mm 1 FRLRB42 100 x 50 mm
1 FFRB124 300 x 100 mm 1 FRLRB63 150 x 75 mm
1 FRLRB124 300 x 100 mm
End stop
End stop
1 FFEB42 100 x 50 mm
1 FFEB63 150 x 75 mm 1 FRLEB42 100 x 50 mm
1 FFEB124 300 x 100 mm 1 FRLEB63 150 x 75 mm
1 FRLEB124 300 x 100 mm
Junction box
Junction box
Supplied with connectors and plates
To be configured as a fourway, tee, bend or Supplied with connectors and plates
straight through connector box To be configured as a fourway, tee, bend or
straight through connector box
1 FFI42 100 x 50 mm
1 FFI63 150 x 75 mm 1 FRLI42 100 x 50 mm
1 FFI124 300 x 100 mm 1 FRLI63 150 x 75 mm
1 FRLI124 300 x 100 mm

Flush lid and recessed lid floor trunking


can be supplied in other widths, depths and
compartment configurations to special order

Contact us on +44 (0) 870 608 9020

45

045_Floor_2012 v4.indd 45 21/09/2012 18:55


industrial floor trunking systems commercial floor trunking systems
chequer plate floor trunking dimensions and technical information

n Flush floor trunking


Trunking length
FTP63 65
overall

133 100 133


FFO332

65
overall

107 76 76 107
FFO342

90° riser bends

picto loupe-65765j.eps 60
overall

120 90 120
Dimensions and technical information (p. 48) AFL332
Installation details (p. 49)
60
overall
Body manufactured from pre-galvanised sheet steel to BS EN 10142 and 3
Lid manufactured from mild steel, powder coated grey 18B25
98 67 67 98 50
Other colours available to special order AFL342
Standard lengths : body 2.0 m, lid 1.0 m
Standard lid thickness : 6.5 mm
Chequer plate floor trunking is available in single compartment as Back entry skirting adaptor
standard complete with lid, all necessary connectors and screws
Internal dividers are fitted on all trunking lengths 225 mm and above to 50
provide lid support
Service outlet boxes are not available for this range

Pack Cat. Nos. Chequer plate floor trunking 150


or
Trunking length – 2 m 200

1 FTP42 100 x 50 mm
1 FTP63 150 x 75 mm
1 FTP124 300 x 100 mm
Cable trunking adaptors
90° riser bend
Supplied with screeding cover
Provides conduit entry with
20 mm knockouts 50

1 FTPRB42 100 x 50 mm
1 FTPRB63 150 x 75 mm
1 FTPRB124 300 x 100 mm 200
150
or
200
End stop
1 FTPEB42 100 x 50 mm Junction box
1 FTPEB63 150 x 75 mm 50
1 FTPEB124 300 x 100 mm
443 443

Junction box
Supplied with connectors and plates
To be configured as a fourway, tee, bend
or straight through connector box
1 FTPI42 100 x 50 mm 37 37
1 FTPI63 150 x 75 mm
1 FTPI124 300 x 100 mm
200

Service outlet boxes

37
65
403 403

Reduced cabling area when fitting


service outlet box
Chequer plate floor trunking can be supplied
in other widths, depths and compartment
configurations to special order 37
60
37 37

Contact us on +44 (0) 870 608 9020

46

046_050_Floor_2012 v4.indd 46 21/09/2012 13:57


commercial floor trunking systems
dimensions and technical information

D
n Shallow flush floor trunking n Underfloor duct = =
W
W D
D
D
W D D AFU261 150 25 == = ==
AFS261 153 25 = = AFU265 150 38 W
W
AFS265 153 38 W AFS261/5 D D
AFS361 153 25 == =
W D == =
AFS365 153 38 D
AFU361 150 25 W W
AFS391 228 25 = = =
AFU365 150 38 D
AFS395 228 38 W AFS361/5
AFU391 225 25 = = =
D
= = =
W
D AFU395 225 38 W
W = Overall trunking width
= = = AFU311 300 25 D
D = Overall trunking depth
W AFU315 300 38 = = =
AFS391/5 W
90° riser bends W = Overall ducting width
D = Overall ducting depth
D
= =
90° riser bends W
D Duct
depth A D
D
= =
50 == = = =50
W
25 78 W
W

D
38 A 90 D D A
== = == =
= = =
150
W W
W 50
150
D D
D = = =
= = =
Back entry skirting adaptor = = = W
W
90° flat bends
W
D
50 = = =
W

150
50 50
or
200

Junction box
302 Junction box B
Cable trunking adaptors trunking
width A B

150/225 302 336


300 477 411
A
50 A

100
15 max adjustment to bring 13 mm max 50adjustment50to bring
level with finished floor level with finished floor

Service outlet box Screed


Screed 150 65
60
25 Trunking or 25 duct
15 ribbon screed 200 L
Ribbon screed
302 221 Compartment W L
Structural floor slab B Structural floor slab
Junction box 15 max adjustment to bring 2C 272 270 15 mm max adjustment to bring
level with finished floor 50 3C 347 279 level with finished floor

Trunking Screed
3C 347 279 Screed
75 A A 75
width302 A 303 38 Trunking W 38 duct
15 ribbon screed B Ribbon screed
150
A 223 Structural floor slab A Structural floor slab
15 max adjustment to bring
15 max adjustment to bring level with finished floor Ø6 HOLES
225 298to bring
15 max adjustment
level with finished floor
13 mm max adjustment to bring 65-78 mm
level with finished floor level with finished floor 50 50
Screed
Screed 60 AFU2CON78
A = Trunking end to end 60 100 25 Trunking
25 Trunking
15 ribbon screed
AFU3CON78
Screed 15 ribbon screed
Screed AFU4CON78
60 A 65 A Structural floor slab
25 Trunking 37
Structural 37
floor slab 25 duct AFU2BB78
15 max adjustment to bring
15 ribbon screed to bring
15 max adjustment
15 max adjustment to bring
13 Ribbon
mm max screed
adjustment tolevel with finished floor AFU3BB78
bring
Structural floor slab level with finished floor Structural floor slab
level with finished floor level with finished floor AFU4BB78
15 mm maxduct,
adjustment to75bring Screed
15 max adjustment to bring Screed Using a 25 mm deep junction boxes 38 Trunking
level with finished floor Screed 75 level with finished floor Screed
38 Trunking and service outlet
65 boxes provide conduit
Service
60 outlet 25 boxes
Trunking 15 ribbon screed entry with 20 mm knockouts 25 only,
15 ribbon
and are
duct Structural
screed
floor slab
Screed Structural floor slab Screed
7515 ribbon screed adjustable from 63 toscreed
75 Ribbon 78 mm deep
38
Structural floor slab Trunking 38 duct
Structural floor slab
Compartment W L H
1515max
ribbon screed
adjustment to bring A A 15 Ribbon
mm max screed
adjustment to bring 75-90 mm
2CStructural
level 297slabfloor
floor
with finished 274 65 Structural
level floor slab
with finished floor AFU2CON90
3C 372 274 65 AFU3CON90
H
4C 372 274Screed
65 Screed AFU4CON90
75 75
38 Trunking L 38 duct AFU2BB90
15 ribbon screed W Ribbon screed AFU3BB90
Structural floor slab Structural floor slab AFU4BB90
37 37
Using a 38 mm deep duct, junction boxes
and service outlet boxes provide conduit
entry with 20/25 mm combination knockouts
All dimensions (mm) are nominal and are adjustable from 75 to 90 mm deep

47

60
046_050_Floor_2012 v4.indd 47 21/09/2012 13:57
commercial floor trunking systems
dimensions and technical information

n Flush lid and recessed lid floor n Chequer plate floor trunking
trunking d D

W w2 W1 = Overall trunking width


Flush lid D = Overall trunking depth
w2 = Overall width including
D trunking lid
W D d
1
W
FF42 102·5 50 47·5
FF63 152·5 75 72·5
FF124 302·5 100 97·5 W1 D w2 A

W = Overall trunking width


FTP42 100 50 150
d D
d = Depth to underside of d D FTP63 150 75 200
trunking lid
D = Overall trunking depth
W
FTP124
W 300 100 350

Recessed lid 90° riser bends


W D d Duct
depth A
FRL42 102·5 50 44
FRL63 152·5 75 69 50 50
FRL124 302·5 100 94 75 75
A

W = Overall trunking width


100 100
d = Depth to underside of d D
trunking lid
D = Overall trunking depth
W

Junction box
Trunking
90° riser bends width A
For flush lid and recessed lid floor trunking
100 150
d D
Duct 150 200
depth A
W 300 350 A
50 50
75 75
100 100 A

Junction box
For flush lid and recessed lid floor trunking

35 35 WIDTH WIDTH

All dimensions (mm) are nominal

48 35 35

046_050_Floor_2012 v4.indd 48 21/09/2012 18:28


Sufficient width to permit screwdriver access to the sides

65 mm 330 mm
65 mm
Ribbon screed
w Installation Ribbon screed
Retrofit
Structural floor slab
Structural floor slab

Sufficient width to permit screwdriver access to the sides


n Installation details
ng
Flush floor trunking in screeded floor
330 mm
25 or 38 mm
65 mm 60 mm
65 mm
Ribbon screed
tallation Ribbon screed
Retrofit
Ribbon screed
Structural floor slab
Installation
Structural floor slab Slab may need removing to
Structural floor slab
accept se rvice outlet box
g When fitting Off Set Tee / Four Way
Shallow flush flooratrunking
cavity depth of more than
in screeded floor105 mm is needed
nking Sufficient width to permit screwdriver access to the sides
Sufficient width to permit screwdriver access to the sides
25 or 38 mm
Off Set Tee / Four Way 25 or 38105
mmmm 60 mm
330 mm 60 mm
Ribbon screed
Installation Ribbon screed
Retrofit 65 mm

Ribbon screed
Retrofit Structural floor slab Slab may need removing to
Structural floor slab Slab may need removing to
Structural floor slab accept se rvice outlet box
accept Service Outlet Box
ng Underfloor duct inWhen fitting floor
screeded Off Set Tee / Four Way
3·5 mm deep
New Installation
Sufficient width
a cavity depthto permit
of morescrewdriver
than 105 mm access to the sides
is needed
recess Minimum 30 mm
Maximum 15 mm adjustment
screed above ducting
nking Recommended minimum 25 or 38 mm
Off Set Tee / Four Way screed depth = 60 mm
105 mm
trunking depth
25 or 38 mm Ribbon screed
Retrofit plus nominal 15 mm 60 mm Service outlet box / junction box
25 or 38 mm Ribbon screed Ribbon screed adjust height to final finished floor
Installation level before pouring screed
Ribbon screed
Structural floorStructural
slab Slab
slabmay need removing to
nstallation floor
accept Service Outlet Box
Structural
Structural floor
floor slab
slab Slab may need removing to
accept se rvice outlet box
ng 3·5 mm deep Minimum 30 mm
New Installation Maximum 15 mm adjustment recess
Flush
Newlid floor trunking in screeded floor
Installation screed above ducting
Whenwidth
Sufficient fittingtoOff Set Tee
permit / Four Way
screwdriver access to the sides
Recommended minimuma cavity depth of more than 105 mm is needed
screed minimum
Recommended depth =
trunking depth
screed depth 25=or 38 mm Service outlet box / junction box
plus nominal
trunking15depth
mm 25 or 38 mm 60 mm
Off Set Tee / Four Way adjust height to final finished floor
plus nominal 15 mm105 mm Ribbon screedRibbon screed level before pouring screed
Retrofit
Ribbon screed Ribbon screed
w Installation
Structural floor slab
Structural
Structural floor slab floor slab
Structural floor slab Slab may need removing to
accept Service Outlet Box

Recessed lid floor trunking in screeded floor


New Installation
Trunking New Installation Minimum 30 mm
ng Maximum 15 mm adjustment 3·5 mm deep
New Installation recess screed above ducting
Recommended minimum
Recommended
screed minimum
depth =
Recommended
screedminimum
trunking depth
depth=
screed depth
plus nominal 15depth
trunking mm= Service outlet box / junction box
plus trunking
nominal depth
15 mm 25 or 38 mm adjust height to final finished floor
plus nominal 15 mm Ribbon screed
Ribbon screed level before pouring screed
Ribbon screed
Ribbon screed
w Installation Structural floor slab
Structural floor slab
Structural Structural
floor slab floor slab

Trunking Chequer plate floor trunking in screeded floor


New Installation
New Installation
Recommended minimum
screed depth =
trunking
Recommended depth
minimum
plus screed
nominaldepth
15 mm=
trunking depth
plus nominal 15 mm Ribbon screed

Ribbon floor
Structural screed
slab

Structural floor slab

49

Trunking New Installation


046_050_Floor_2012 v4.indd 49 21/09/2012 14:00
pedestal units
technical information

n Pedestal units dimensions


Single socket
Cat. No. PED1WHI
A 54
B 89
A D
C 102
D 24 B C

Twin socket
Cat. No. PED2WHI
A A 54 D 24
54
B 89 D
B C
C 162 A 89 102
C
D 24 B

Back-to-back sockets
Cat. No. PED3WHI
single socket D
A 24
A 54 C 54
B A D
162
B 178 B
89 C
C 102
D 24

twin socket Cat. No. PED4WHI


A D 24
A 54 54
B
C D
B 178 178 102

C 162 A
B C
D 24

For all pedestal units above, hole diameter in base is 20 mm

Pyramid box Cat. No. PED8WHI


C C
A 55
B 368
D 24
C 184
A D
B
D 24C 54
162
A 178
B B

C C

A
B B

All dimensions (mm) are nominal

50

046_050_Floor_2012 v4.indd 50 21/09/2012 14:00


Protection classifications
Protection against solid bodies and liquids : Index of protection - IP xx Protection against mechanical impact :
Index of protection - IK
Degree of protection of enclosures of electrical equipment in accordance with standards
IEC 60529, BS EN 60529 According to standards IEC 62262 and
±
Up to 1 000 V and 1 500 V = BS EN 62262

1st figure : 2nd figure : Impact


protection against solid bodies protection against liquids IK Tests energy
(in Joules)
IP tests IP tests
0 s52/01/95F No protection 0 s52/07/95F No protection IK 00 0

0.2 kg
Ø 50 mm
Protected against solid Protected against IK 01 75 mm 0·15
bodies of 50 mm and 1 vertically falling drops
1 greater (e.g. accidental s52/08/95F
of water (condensation)
0.2 kg
contact with the hand)
IK 02 100 mm 0·2
s52/02/95F
15° Protected against drops 0.2 kg
2 of water falling up to 15°
IK 03 0·35
Ø 12·5 mm s52/09/95F from the vertical 175 mm
Protected against solid
2 bodies of 12·5 mm and 0.2 kg
greater (e.g. finger) IK 04 250 mm 0·5
60° Protected against water
s52/03/95F 3 sprayed up to 60° from
s52/10/95F the vertical 0.2 kg
IK 05 350 mm 0·7
Ø 2·5 mm Protected against solid 0.5 kg
3 bodies of 2·5 mm and Protected against
IK 06 1
greater (e.g. tools, wires) 4 splashing water from 200 mm
s52/11/95F all directions
s52/04/95F 0.5 kg
IK 07 400 mm 2

Protected against solid Protected against jets of 1.7 kg


Ø 1 mm bodies larger than 1 mm 5 water from all directions
4 s52/12/95F IK 08 295 mm 5
(e.g. thin tools and
s52/05/95F fine wires)
5 kg
IK 09 200 mm 10
Protected against
6 powerful jets of water
from all directions 5 kg
s52/13/95F
Protected against dust
IK 10 400 mm 20
5 (no harmful deposit)
s52/06/95F
Protected against the (1) A product previously classed as IP xx-7 can be assumed
7
1m

effects of temporary to fulfill the conditions of an IP xx - IK 08


15 cm
min.

immersion in water
s52/14/95F
This table can be used to ascertain the resistance
Protected against the of a product to an impact given in Joules from
Completely protected
6 continuous effects of the IK code (graduated from 00 to 10).
m

against dust
8 immersion in water It can also be used to ascertain the
having regard to correspondence with the old IP code 3rd digit
specific conditions
and the corresponding external “Ag” conditions.

The contents of the Protection Classifications charts are for guidance only. If you have any doubt as to the interpretation of the information
contained therein, please refer either to the standard itself or contact Legrand.

Health and Safety at Work, etc. Act. 1974 For information concerning wiring device
standards outside the UK contact :

BSI
Statement to Purchasers and Prospective Purchasers Customer Services
1. Section 6 of this Act provides that other applicable standards, regulations for the 09:00 to 17:00 – Monday to Friday
manufacturers, designers, importers or installation of equipment by the Institute of
suppliers of articles for use at work have a duty Electrical Engineers or any other applicable Tel : +44 (0) 20 8996 9001
to ensure so far as is reasonably practical, that Codes of Practice. Fax : +44 (0) 20 8996 7001
the article will be safe and without risk to health
when properly used. An article is not regarded Email : cservices@bsi-global.com
as being ‘properly used’ if it is used without
regard to any relevant information or advice Health and Safety at Work Act
relating to its use made available by the
manufacturer, designer, importer or supplier. The Electricity at Work marking appears on electrical or
Regulations, 1989 electronic products from Legrand
2. With regard to these provisions the following and enables the circulation of goods
is given as a guide to the information which is outside the UK.
readily available to you. This information relates 1. All installations and maintenance should be
to those products detailed in our catalogue(s) carried out within the provision of the above CELOGO-001
or associated literature or may be obtained by Act and by persons so qualified as defined in black
specific request to the Company. the Act.
3. All products should be installed and 2. Information and advice on the suitability of
maintained in accordance with good our products can be obtained from Legrand
engineering practice and relevant British or Electric Limited on specific request.

Conditions of sale
Please consult our current price list
In accordance with its policy of continuous improvement the Company reserves the right to change specifications and designs without notice.
All illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on the Company.

051_Floor_2012 v1.indd 51 21/09/2012 18:27


Contact details
United Kingdom
Great King Street North,
Birmingham, B19 2LF
Customer Sevices:
Tel: +44 (0) 845 605 4333 Fax: +44 (0) 845 605 4334
E-mail: legrand.sales@legrand.co.uk
Quotations and Technical Support:
Tel: +44 (0) 870 608 9020 Fax: +44 (0) 845 605 5334
E-mail: uk-cmsales@legrand.co.uk
Republic of Ireland:
Tel: 01 295 9673 Fax: 01 295 4671
E-mail: legrand.sales@legrand.co.uk

Distributor:

Head office (UK and Ireland):


Floor systems technical guide 10/2012.3.5k

Legrand Electric Limited


Great King Street North, Birmingham, B19 2LF
Tel: +44 (0) 870 608 9000 Fax: +44 (0) 870 608 9004
Website: www.legrand.co.uk

The Legrand logo is a registered trademark


This document is printed on sustainably sourced paper. Please recycle. of the Legrand group of companies.

Feature Pages.indd 10 21/09/2012 18:01