The Alarm.com platform opens a whole new world to the NEO’s capabilities:
Tech Note: The panel MUST be a v1.1+ and the HS2LCD keypads should
be v1.11+.
Tech Note: If the panel or keypads do not meet the minimum requirements
listed above, they should be replaced or Flash Upgraded using
the DLS5 Flash Wizard; before trying to install the Alarm.com
module.
Tech Note: The Flash Upgrade must be done through the PCLink process
prior to installation the 8080 module.
Tech Note: The panel and keypad versions can be verified in Section [900]
Tech Note: See April 2015 Tech Tip for the Flash Upgrade process.
1 of 2
June 2015
Notes:
• All NEO panels must be v1.1+ for Alarm.com – Flash Upgrade is available.
• All LCD keypads must be v1.1+ for Alarm.com – Flash Upgrade is available
for hardwire keypad only.
• Wire Free LCD must be v1.1+ (which manufacturing started on Jan 13, 2015)
(no Flash Upgrade is available – hardware replacement only.)
• All HS2TCHP’s from original release are compatible with Alarm.com. However,
interactive “Press and Hold” for signal test, cell strength, etc. is not available on
the touchscreens – the Dealer can access these features from the Interactive
Menu within the*6 User Menu.
• Older keypad (<1.1) do not support the Alarm.com functions (“Press and Hold”
functions, Message Banner, access to Section 851), but can be used on the NEO
for standard panel operations not related to Alarm.com.
• The Alarm.com (8080) module can be installed up to 100 ft. from the control
panel and is wired using 6 Conductors. 2 Conductors for Power, 4 Conductors
for the RS-422 interface.
12vDC+ 12vDC+
12vDC – 12vDC –
TX + RX +
TX – RX –
RX + TX +
RX – RX –
2 of 2