Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

June 2015

Alarm.com Integration to NEO

NEO HS2016 / HS2032 / HS2064 / HS20128 v1.0 ~ v1.xx

3G8080(I) / CD8080(I) (U.S. Market)

3G8080(I)RG (Canada Market)

The Alarm.com platform opens a whole new world to the NEO’s capabilities:

• Z-Wave control of lights, locks and thermostats


• Partition controls – each partition independently or as groups
• Arming and Disarming control via smart devices (cell phone, computers, tablets)
• Notifications sent to the end users via SMS text or email messages
• Plus a whole lot more…

Visit www.dsc.com and www.alarm.com for more information.

 Tech Note: The panel MUST be a v1.1+ and the HS2LCD keypads should
be v1.11+.

 Tech Note: If the panel or keypads do not meet the minimum requirements
listed above, they should be replaced or Flash Upgraded using
the DLS5 Flash Wizard; before trying to install the Alarm.com
module.

 Tech Note: The Flash Upgrade must be done through the PCLink process
prior to installation the 8080 module.

 Tech Note: The panel and keypad versions can be verified in Section [900]

Section [900] [000] Panel Version


Section [900] [001] – [016] Keypad Versions

 Tech Note: See April 2015 Tech Tip for the Flash Upgrade process.

1 of 2
June 2015

Alarm.com Integration to NEO

Notes:

• All NEO panels must be v1.1+ for Alarm.com – Flash Upgrade is available.

• All LCD keypads must be v1.1+ for Alarm.com – Flash Upgrade is available
for hardwire keypad only.

• Wire Free LCD must be v1.1+ (which manufacturing started on Jan 13, 2015)
(no Flash Upgrade is available – hardware replacement only.)

• Alarm.com functionality is only compatible with LCD’s v.1.1+ and the


HS2TCHP’s.

• All HS2TCHP’s from original release are compatible with Alarm.com. However,
interactive “Press and Hold” for signal test, cell strength, etc. is not available on
the touchscreens – the Dealer can access these features from the Interactive
Menu within the*6 User Menu.

• Older keypad (<1.1) do not support the Alarm.com functions (“Press and Hold”
functions, Message Banner, access to Section 851), but can be used on the NEO
for standard panel operations not related to Alarm.com.

• The Alarm.com (8080) module can be installed up to 100 ft. from the control
panel and is wired using 6 Conductors. 2 Conductors for Power, 4 Conductors
for the RS-422 interface.

12vDC+ 12vDC+
12vDC – 12vDC –

TX + RX +
TX – RX –
RX + TX +
RX – RX –

• The approved extended antennas for the Alarm.com module are:


GS-15ANTQ ~ 15’ Indoor
GS-25ANTQ ~ 25’ Indoor / Outdoor
GS-50ANTQ ~ 50’ Indoor / Outdoor

2 of 2

You might also like