Note. The following masses are between two adjacent stories or on the
nodes released from floor rigid diaphragm by *Diaphragm Disconnect command.
The masses are proportionally distributed to upper/lower stories according
to their vertical locations. For dynamic analysis, however, floor masses
and masses on vertical elements remain at their original locations.
* EQUIVALENT SEISMIC LOAD IN ACCORDANCE WITH UNIFORM BUILDING CODE 1997 [UNIT: kN, m]
_____________________________________________________________________________________________
Modeling, Integrated Design & Analysis Software Print Date/Time : 02/17/2020 11:59
http://www.MidasUser.com
Gen 2020 -1/3-
midas Gen SEIS LOAD CALC.
===========================
ECCENTRICITY RELATED DATA
===========================
X - D I R E C T I O N A L L O A D Y - D I R E C T I O N A L L O A D
---------------------------------------------------------------------------------------------------
----
The accidental amplification factors are automatically set to 1.0 when torsional amplification effe
ct
to accidental eccentricity is not considered.
The inherent amplification factors are automatically set to 0 when torsional amplification effect
to inherent eccentricity is not considered.
The inherent amplification factors are all set to 'the input value - 1.0'.(This is to exclude the t
rue
inherent torsion)
---------------------------------------------------------------------------------------------------
----
S E I S M I C L O A D G E N E R A T I O N D A T A X - D I R E C T I O N
STORY STORY STORY SEISMIC ADDED STORY STORY OVERTURN. ACCIDENT. INHERENT TOTA
L
NAME WEIGHT LEVEL FORCE FORCE FORCE SHEAR MOMENT TORSION TORSION TORS
ION
---------- -------- ------- -------- -------- -------- -------- --------- --------- --------- -----
----
Roof 2552.5 9.6 513.8014 0.0 513.8014 0.0 0.0 0.0 0.0
Modeling, Integrated Design & Analysis Software Print Date/Time : 02/17/2020 11:59
http://www.MidasUser.com
Gen 2020 -2/3-
midas Gen SEIS LOAD CALC.
0.0
4F 2821.837 6.6 390.5118 0.0 390.5118 513.8014 1541.404 0.0 0.0
0.0
3F 2375.4 3.6 179.3071 0.0 179.3071 904.3132 4254.344 0.0 0.0
0.0
2F 2819.46 0.6 35.47117 0.0 35.47117 1083.62 7505.205 0.0 0.0
0.0
G.L. -- 0.0 -- -- -- 1119.091 8176.66 --- --- --
-
---------------------------------------------------------------------------------------------------
----
S E I S M I C L O A D G E N E R A T I O N D A T A Y - D I R E C T I O N
STORY STORY STORY SEISMIC ADDED STORY STORY OVERTURN. ACCIDENT. INHERENT TOTA
L
NAME WEIGHT LEVEL FORCE FORCE FORCE SHEAR MOMENT TORSION TORSION TORS
ION
---------- -------- ------- -------- -------- -------- -------- --------- --------- --------- -----
----
Roof 2552.5 9.6 513.8014 0.0 0.0 0.0 0.0 0.0 0.0
0.0
4F 2821.837 6.6 390.5118 0.0 0.0 0.0 0.0 0.0 0.0
0.0
3F 2375.4 3.6 179.3071 0.0 0.0 0.0 0.0 0.0 0.0
0.0
2F 2819.46 0.6 35.47117 0.0 0.0 0.0 0.0 0.0 0.0
0.0
G.L. -- 0.0 -- -- -- 0.0 0.0 --- --- --
-
---------------------------------------------------------------------------------------------------
----
=================================================
COMMENTS ABOUT TORSION
=================================================
---------------------------------------------------------------------------------------------------
----
If torsional amplification effects are considered :
---------------------------------------------------------------------------------------------------
----
Accidental Torsion , Story Force * Accidental Eccentricity * Amp. Factor for Accidental Eccentricit
y
Inherent Torsion , Story Force * Inherent Eccentricity * Amp. Factor for Inherent Eccentricity
---------------------------------------------------------------------------------------------------
----
If torsional amplification effects are not considered :
---------------------------------------------------------------------------------------------------
----
Accidental Torsion , Story Force * Accidental Eccentricity
Inherent Torsion , 0
---------------------------------------------------------------------------------------------------
----
The inherent torsion above is the additional torsion due to torsional amplification effect.
The true inherent torsion is considered automatically in analysis stage when the seismic force is
applied to the structure.
---------------------------------------------------------------------------------------------------
----