Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

AMT 75 Series

High Speed Broadcast Modem

Introduction Forward Error Correction (FEC)


Advantech’s AMT 75 High Speed Broadcast Aside from the traditional FEC and modulations
Modem is a versatile and effective solution for supported in DVB-S and DVB-DSNG, the AMT75
provides advanced DVB-S2 methods to
any high speed environment.
improve the performance in satellite
conditions. DVB-S2 is the latest open standard
The AMT-75 Series modem is designed using
“Software Defined Radio” techniques to advanced satellite transmission technique from
ensure unrivalled flexibility, and upgrade paths the DVB community. Among the key elements
to meet the increasingly demanding of DVB-S2 is its use of powerful FEC system
requirements now and in the future. based on concatenation of BCH (Bose-
Chaudhuri-Hocquenghem) with LDPC (Low
Density Parity Check) inner coding. The result is
Features
performance which is at times only 0.7dB from
• Available as Modulator or Demodulator only
options the Shannon limit.
• Powerful Forward Error Correction (FEC) choices
compliant with DVB-S, DVB-DSNG, and DVB-S2. Additionally, for lower speed applications, the
The DVB-S2 implementation includes AMT75 provides enhanced Turbo Product
16APSK/32APSK and both 16k (SHORT) and 64k Code (eTPC).
(NORMAL) FEC Block sizes
• 64QAM support is backed with powerful LDPC Advanced Modulation modes
BCH implementation to provide 155Mbps high
The AMT75 was among the first to provide
efficiency link.
• Also supports eTPC Turbo code for lower speed advanced modulation modes such as
applications (up to 20Mbps). 16APSK/32APSK supports to the DVB-S2
• Symbol Rates 32ksps to 45Msps community. 64QAM is a new capability which
• Modulation and FEC options are all “soft key” is implemented using similar BCH and LDPC
controlled allowing simple field upgrades techniques originally intended for the high
• Excellent spurious performance speed DVBS2 community.
• L Band: 950 to 1750 MHZ IF ranges
• L Band+: 950 to 2000 Mhz IF ranges
Performance
• 70+/-18Mhz or 140+/-36Mhz IF ranges
• Wide range of Network Interface Cards (NIC): The AMT75 performance gain realized by the
o EIA530/RS422 combination of advanced modulation and
o HSSI and multi-HSSI interfaces FEC can be translated directly into higher data
o 10/100Mbps Ethernet (IP routing or
throughput, reduced antenna size or reduced
bridging support)
o G.703 interfaces satellite bandwidth, which significantly reduces
o Multi G703 interfaces transponder costs; provides more link margin or
o 1GigE L2 and bridging decrease antenna cost.
o OC3/STM1 support
Coupled with wide range of NIC, the AMT75
• 1:1 and 1:10 redundancy switches available.
• Monitoring and control via Ethernet using Web can perform virtually any function under any
Server, HTTP, Telnet or SNMP, or via terminal environment.
mode RS232.
The AMT75. Versatile. Effective. Affordable.

www.AdvantechAMT.com
AMT 75 Series
High Speed Broadcast Modem

Interface options
EIA530/RS422: traditional interfaces supporting G.703 interfaces (IBS/IDR)
mixed traffic loads. Can either be transported A powerful interface card providing both
transparently or can interface and 10/100BaseT Ethernet (IP Gateway) and up to
interoperate with Frame relay or HDLC. eight E1/T1 G703 interfaces. The versatility and
capabilities provided by the interfaces make
HSSI and Triple-HSSI interface: High-Speed the TG ideal for applications such as Cellular
Serial Interface (HSSI) is a serial interface that backhaul, point-to-point and point-to-
supports transmission rates up to 52 mbps. It is multipoint transmission for voice, video and
traditionally used to connect routers on local data services.
area networks over VSAT or over wide area
networks (WAN). This interface allows for the deployment of a
single G.703 interface respecting IBS/IDR or
10/100Mbps Ethernet (IP router/Bridge): A can operate in closed networks mode to
powerful IP router/Bridge interface supporting provide up to 8 G.703 interfaces and IP
numerous IP connectivity options: together over an optimized framing format
IP options: (Advanced Packet over Carrier – APOC).
• Static and Dynamic IP routing (RIPv1&2) Available options include the following:
• DHCP Server
• Network Address Translation Option 1: Default 1 G.703 support (APOC)
• Packet Filtering (Firewall) Option 2: 1 G.703 + IP/Bridge support
• Quality of Service support to Level 3 Option 3: 1 G.703 with IBS/IDR (IBS/IDR support
• Command line interface (Industry is limited to a single G703 interface)
Standard) Option 4: 2 G.703 support (APOC)
• SNMP v.1 & v.3, MIB II Option 5: 2 G.703 + IP/Bridge support (APOC)
• DHCP Server Option 6: 3 G.703 + IP/Bridge support (APOC)
• DNS Client Option 7: 4 G.703 + IP/Bridge support (APOC)
• FTP/TFTP Client Option 8: 8 G.703 + IP/Bridge support (APOC)
• AAA (Authentication, Authorisation &
Accounting) Very high speed interfaces:
• Local AAA (Access Rights Table) New interface provides four switched
• PAP, CHAP, MS-CHAP (Client/Server 10/100/1000BaseT ports and a Small Form
Authentication) Factor Pluggable (SFP) interface supporting a
• RADIUS, TACACS+ (Client, Remote variety of optical OC3/STM1 or 1GigE interface.
server authentication)
• Ping, Traceroute, Discovery Protocol When supporting OC3/STM1, the AMT75 can
• IP, TCP, UDP, ICMP Protocol Statistics provide transparent support for the
• Interface Statistics 155.52Mbps TDM data rate and format. In
• IPSec (up to 256bit AES) Ethernet mode, the AMT75 can provide L2
Bridging options: forwarding and/or use bridge protocols, such
• Spanning Tree Protocol (STP) as RSTP, to build local and remote forwarding
• Rapid STP (RSTP) MAC tables. In Ethernet mode, the AMT75 can
• MAC filtering support VLAN and even jumbo frames.

Advantech Redundancy Modules:


ARM-71x: 1:1 redundancy for EIA530 or HSSI
and IF.
ARM-72x: 1:1 redundancy supporting 8 G703
and IP and IF.
ARM-81x: 1:10 redundancy for EI530 or HSSI.
ARM-82x: 1:4 redundancy for octal G703/IP.
AMT 75 Series
High Speed Broadcast Modem

PERFORMANCE SPECIFICATIONS
Rates Options 64kbps to 10Mbps
Data Rate 64 kbps to 155 Mbps 64kbps to 52Mbps
64kbps to 155Mbps
16 ksps to 40 Msps 32ksps to 45Msps DVB-S (128ksps to 45Msps DVB-
Symbol Rate
Modulator` S2)
Optional 10/100BaseT IP Gateway
Optional Octal G.703
Optional single or multiple ASI Interfaces
RS-530/422
Data Interfaces Optional HSSI or Triple HSSI
Optional IP encapsulator
Optional OC3/STM1
Optional 1GigE (optical) and 4 1GigE (switched ports)
Scrambling, Descrambling DVB (and no scrambling for BPSK, QPSK and OQPSK)

External M&C Interface: RS-232 Terminal mode, RS-485 Packet mode,


Monitoring and Control (M&C)
10/100BaseT for Web Server, SNMP, Telnet or HTTP
Interface
Configuration Parameter Storage: NVRAM

INTERFACE SPECIFICATIONS
Data Interface

RS-530/422 25 pin D connector

HSSI or triple HSSI 50-pin SCSI-2 type connector for HSSI and RJ-45 for Ethernet option
Receiver/Transmitter ASI BNC (f), 75 Ohms for ASI
Interface Encoded Line Rate: 270 Mbps +100 ppm
Min. Sensitivity (D21.5 idle pattern): 200 mV
Max. Input Voltage: 880 mV p-p
Min. Discrete Connector Return Loss: 15 dB
Max. Distance: 150 Meters
Multiple G.703 Encoded Line Rate: n x 2048 kbps (with Fractional E1) +102.4 bits/s (+50 ppm)
Line Coding: HDB3
Digital Interface: RJ45 balanced for bi-directional G.703
Dual 10/100BaseT RJ45 connections for simultaneous support of IP router/bridging.
OC3/STM1 and 1GigE OC3/STM1: SFP interface allowing varying package types
1Gig E: SFP interface allowing carrying package type
Four 10/100/1000BaseT switch: RJ45 connections
PHYSICAL AND POWER SPECIFICATIONS
Dimensions Standalone or rack-mountable 1U Rack or 1U EIA chassis
Height: 4.4 cm (1.75”)
Width: 48.26 with mounting ears or 43.2 cm without
(19” or 17”)
Depth: 40.0 cm (15.75”)
Weight: 8 lb (3.7 kg) maximum
Power, AC Power Supply Voltage 90 – 264 VAC, 50/60 H
Power, DC (Option) DC Power: -48 VDC (32 to 72 VDC)
Power Consumption: 50 Watts not including BUC power
supply
BUC Power Supply: 24 VDC @ 4.0 A, 48 VDC @ 2.3 or
4.0 A
ENVIRONMENTAL SPECIFICATIONS
Environmental Operating Temperature: 0oC to 45oC (32oF to 122oF)
Storage Temperature: -25oC to 85oC (-13oF to 185oF)
Relative Humidity: Operating: Up to 90% non-condensing
Non-Operating: Up to 95% non-condensing
Altitude: Operating: Up to 10,000’ (3,045 M)
During Transit: Up to 40,000’ (12,180 M)

PB-AMT075-01 Rev 9 Issued on 05/09/2007 Specifications are subject to change without notice
www.satcom-services.com
AMT 75 Series AMT 70 Series
High Speed Broadcast Modem Universal SCPC Modem

MODULATOR SPECIFICATIONS
DVB-S and Intelsat 308/309
BPSK: 16 kbps to 36 Mbps QPSK: 16 kbps to 73 Mbps
DVB-DSNG
QPSK: 64 kbps to 73 Mbps 8PSK: 128 kbps to 110 Mbps
Data Rates OQPSK: 64 kbps to 72 Mbps 16QAM: 128 kbps to 140 Mbps
DVB-S2 (advanced BCH and LDPC)
8PSK: 256 kbps to 110 Mbps
16APSK: 340 kbps to 140 Mbps
QPSK: 64 kbps to 73 Mbps
32APSK: 470 kbps to 155 Mbps
64QAM: 1024kbps to 155Mbps
Modulator Roll-Off Factor 12% to 35% in 1% steps
Intelsat 308/309
DVB-S/DVB-DSNG Coding
Forward Error Correction DVB-S2 SHORT and NORMAL FEC Block
* 1 * 2 * 1 * 3 2 4 5 7 8
(FEC) Code Rates SHORT Block 16kbit ¼ , /3 , /5 , /2 , /5, /3, /5, /6, /8, /9
* 1 * 2 * 1 * 3
NORMAL Block 64kbit ¼ , /3 , /5 , /2 , /5, /3, /5, /6, /8,8/9,9/10
2 4 5 7
* Only available in QPSK according to DVB-S2 Specification

Type N (f) 50 Ohms for L band, BNC (f) for 70/140 MHz
IF Output Connector
Impedance: 50 Ohms; Return Loss: >12 dB
L Band: 950-1750 MHz variable in 1Hz steps
Optional: 950-2000 MHz variable in 1Hz steps
RF Output Frequency
IF Band: 70 +/-18 MHz or 950-2000MHz
140 +/-36 MHz or 950-2000MHz
Range: +0 to -25 dBm, adjustable in 0.10 dB increments
RF Output Power
Accuracy: +0.5 dB; Temp Stability: +0.25 dB
Frequency: 10 MHz, 0 dBm, +2 dB
BUC Reference Frequency -9 -9
Stability: 1 x 10 /per day; +/-150 x 10 long term,
and Stability
no frequency/phase hits for external ref.
Phase Noise (1 Hz bandwidth)
BUC 10 MHz Reference -115 dBc/Hz maximum @ 10 Hz
-150 dBc/Hz maximum @ 10 kHz
Frequency Phase Noise -135 dBc/Hz maximum @ 100 Hz;
-160 dBc/Hz maximum @ 100 kHz
-148 dBc/Hz maximum @ 1 kHz
Typical Eb/No Performance, QPSK 8PSK 16QAM/16APSK
DVB-S < 0.5dB margin N/A N/A
DVB-DSNG < 0.5dB margin < 0.7dB margin <1dB margin
DVB-S2 < 0.5dB Margin < 0.7dB margin <1dB margin
DEMODULATOR SPECIFICATIONS
IF Input Frequency L band 950-2150 MHz, variable in 100 Hz steps
Demodulator Roll-Off Factor 15% or 35%
Front-End BPF Tuneable Filter: 950 MHz < fo < 2150 MHz;
Flatness: < 0.8 dB in any 54 MHz bandwidth;
Nominal Input Level -45 dBm - 10log(400/R) dBm, where R = Symbol Rate in kSymbols
AGC Range +20 dB
Maximum Input Signal Level -10 dBm
IF Input Connector Type F (f) for L Band
Impedance: 75 Ohms;
Option: Type BNC (f) for 70/140MHz 50 Ohms
Return Loss: > 10 dB;
LNB Alarm for Short Circuit
Noise Figure 9 dB typical, 12 dB at maximum AGC gain
LNB Power Supply Output Selectable LNB Supply Voltage: ON/OFF, 18 VDC (Horizontal Pol.) or
and Control 13 VDC (Vertical Pol.)
LNB Control: 22 +4 kHz single tone burst, amplitude = 0.6 +0.2 V p-p
Symbol Rate Acquisition +200 ppm
Range
Synchronization and Depends on data rate, frequency uncertainty, and operating Eb/No. Following is a
Acquisition Time sample:
Average Acquisition Time: <5 sec, 256 kbps @ +/-30 kHz sweep range
<0.5sec, >2Msymbols/S inside +/- 2% of Symbol rate with DVB-S2
An ISO9001: 2000 Company

United States
SATCOM SERVICES
Mike Termondt
25 Creek Lane, Oak View, CA 93022 USA
Tel.: (805) 649-1284
Fax: (805) 500-4328
Email: mike@satcom-services.com

You might also like