Table of Contents 1. Introduction 2.

Safety Note
1.Introduction The Meter is a handheld and battery operated very The following safety notes should be observed
SMD METER 2.Safety note convenient small Tool, that is specially used to prior to using this Meter and any associated
3.Explanation of Controls and Indicators measuring SMD(Surface Mounting Device),there accessory.Although the Meter do not used to
3-1.Product Illustration are resistor, Capacitor, Diode, Zener and LED, measuring to exceed Safety Voltage ,but
3-2.Push Buttons Moreover, the Meter have the continuity checking there are situations where hazardous conditi
USER’S MANUAL 3-3.LCD display function And batery power Measurement. -on may be present.
4.Specification The Meter is designed to meet IEC1010-1 standard ● Inspect the Meter case before using.Do
4-1.General Feature and Stipulation of 2-Pollution Grade. Not use damaged device.
4-2.Electrical Specification The Meter conform to the European Union‟s ● Inspect the Pin Holder and Pin gold
5.Testing Operation following Requirement:CE regulation 89/336 -plated state.
MODEL: 990B 5-1.Resistance Measurement (EMC Electromagnetic Compatibility). ● Do not attempt use the Meter as tweezers
5-2.Capacitance Measurement The entire outer surface of the Meter case has been to prevent the pin tip from damage.
5-3.Diode Check with thermo plastic elastomer, and the two testing ● Do not used in the environment with
5-4.Continuity Check pins has been gold-plated, so that it is reduce pin explosive gas,vapor,or dust.
5-5. Zener/LED Measurement contact resistance and prevent to get rusty.
5-6. Battery Power Measurement This operating instruction covers information on Caution
6.Maintenance safety and caution,so please read relevant Never use the Meter on alive circuits .
6-1.Replacing The Battery information carefully and observe all the warming
6-2.Cleaning and note strictly.

-2- -3- -4-


3. Explanation of Control and Indicators
3.1 Product Illustration 3.2.Push Buttons Note: after auto power-OFF is active,
NO Indicato Meaning
[1]"FUNC":it is the function select key that pushing the "REL" key can turn on the Meter
6 5 4 2 1
3 acts trigger. again, and pushing the "FUNC" key can turn 1 AUTO Auto Ranging
Use the Push Button as switch of on again when the Meter on the “R/D/C”
2 DC Direct current
Resistance/Capacitance/Diode/Continuity Range, But the meter can not auto power off,
7 8 want to power off, must be break battery 3 REL Relative Testing
when the FUNCTION Switch turn on
“R/D/C” Range. connenction. Diode
4
The Meter is have not Power Key. When 3-3.LCD Display Checking Mode
install the 1.5V(AAA)×2 Battery,The Continuity
① LCD 5
Checking Mode
Meter immediately Power ON.
② "REL"Push Button Capacitance
[2]"REL" Key: Press "REL" Button to 6 nuF
③ "FUNC" Push Button Function Select Units(nF,uF)
Enter or exit the relative value measu Resistance
④ FUNCTION Switch 7 MKΩ
-ring mode . Units(Ω, KΩ,MΩ)
⑤ Pin Holder
Push the key, the present display value will be
⑥ Test Pin (Gold plated, 'INPUT' Terminal) 8 V Voltage Units
stored in memory, then the new display
⑦ Test Pin (Gold plated, 'COM' Terminal) 9
Low
value is the difference between input value Battery lndicator
⑧ Battery cover and stored data.
-5- -6–
-7- -8-

Downloaded from www.Manualslib.com manuals search engine


4.Specification ● Operating temperature &Humidity:0-40'C 4-2.Electrical Specification 5.Testing Operation
4-1.General Feature (32-104'F) &<80%RH Function. Range Resolu Accuracy Caution
● 4000 count LCD display. ● Storage temperature & Humidity:-10-50 -tion when measuring SMD device on the PCB,
● Auto ranges. ● perating temperature &Humidity:0-40℃
● Over-rang indication display “OL” (32-104℉) &<80%RH Resistance 400Ω/4KΩ 0.1Ω ±(2.0%rdg+5dgt) you must be Disconnect power and discharge
●Zener diode Test ● Safety Class:IEC1010-1,CAT Ⅲ /40K/400K/ “ all high-voltage capacitors.
●LED Test ● Auto Power OFF:lf the Meter is idle for 4MΩ “
●Battery Power Test more than 15 minutes,the Meter 40MΩ ±(2.5rd%+5dgt)
5-1. Resistance Measurement
●Specialized SMD TEST or TEST automatically tums the power off. Capacitance 4nF/40nF/ 1pF ±(2.5%rdg+5dgt)
“ [1] Set the FUNCTION Switch to “R/D/C”
DIP Component with leade. ● EMC:According to CE regulation 400nF/4μF/
89/336. 40μF/200μF ±(3%rdg+5dgt) [2] Connect the Test Pins to across the
● Dimension(L×W×H) & Weight: 206 X Diode Test Open Voltage : 1.5V, Testing Current : 2mA resistance under measurement.
36 X 25mm,Approx.50 g [3] You can get reading from LCD.
Continuity When the resistance is less than
● Environmental condition:
Check approx.30Ω,The Buzzer is sounded. [4] When test low value of the resistance,
(1) Indoor use;
(2) Altitude up to 2000meter. Zener/LED Open Voltage : MIN 20V, You can short two Test Pins, And Press
Testing Current : Appr. 1mA
● Accessory: "REL" Button to clear zero, then testing
BATTERY Loading Current:
1. Spare Test Pin: 2PCS ±(1.5rd%+5dgt) to obtain volue of the resisitance.
● Low Batteery Indication POWER Approx. 10mA
● Power Supply: 1.5V(AAA)×2 Battery 2. Special Test Leads: electric rating 500V 10A
- 10 - –11 – - 12 -
-9-
5-3 Diode Check 5-5. Zener or LED Check [1] Open the battery cover on the bottom
5-2.Capacitance Measurement [1] Set the FUNCTION Switch to “R/D/C”, [1] Set the FUNCTION Switch to “ ” case by pushing the battery cover.
[1] Set the FUNCTION Switch at “R/D/C”, And press „FUNC‟ button until symbol of [2] Connect 'INPUT' Test Pin to the anode, [2] Remove old battery and put new two
And press ‘FUNC’ button until symbol of “ ” is displayed on LCD. and Connect 'COM' Test Pin to the into battery holder.
“ ” is displayed on LCD. [2] Connect 'INPUT' Test Pin to the anode, cathode of the ZENER/LED under testing.
[2] Connect the Test Pins to across the and Connect 'COM' Test Pin to the [3]The measured value of Zener Voltage
Note:
cathode of the diode under testing. show on the LCD, Or show LED working
Capacitance under measurement. Voltage on the LCD. Battery type: 1.5V(AAA)×2
[3] You can get reading from LCD.
[3] You can get reading from LCD. 5-7 Battery Power Measure If you do not use the meter a long
A good silicon junction drop between
[4] When test low value of the capacitance, [1] Set the FUNCTION Switch to “ ” time, pleseRemove the batteries from
0.5V-0.8V.
You can press "REL" Button to clear zero, 5-4.Continuity Check [2] Connect 'INPUT' Test Pin to the anode, the meter.
then testing to obtain precist volue of the [1] Set the FUNCTION Switch at “R/D/C”, and Connect 'COM' Test Pin to the 6-2.Cleaning
Capacitance. cathode of the Battery under testing. The meter can be cleaned with soft clean
And press „FUNC‟ button until symbol of
Caution [3]The measured value of Battery Voltage cloth to remove any oil,grease or grim.
“ ” is displayed on LCD. at DC10mA load show on the LCD,.
To avoid damage to the Meter or to the Do not use liquid solvent or detergent.
[2] Connect test pins across two points of 6.Maintenance
equipment under test, disconnect power
the circuit under testing. 6-1.Replacing The Battery
and discharge all high-voltage capacitors Above picture and content just for your
When the resistance reading is less than When meter display ,the battery
before measurement capacitance. reference. Please be subject to the actual
10~60 Ω, the buzzer generates 2KHz must be replace to maintain nomal
When testing large capacitance, it will take
beep to indicate continuity. operaion. products if anything different or updated.
longer time before the final indication(For
Please pardon for not informing in advance.
100uF , it will take about 15 seconds).
- 14 - - 15 - - 16 -