5/22/2021 API 571 Study Guide- Practice Questions for API 570 Exam- Boiler Water Condensate Corrosion

nsate Corrosion (4.3.5) Flashcards | Quizlet

API 571 Study Guide- Practice Questions for API 570


Exam- Boiler Water Condensate Corrosion (4.3.5)
Terms in this set (6)

Corrosion from Oxygen in B


boiler feed water usually
creates:
A. Uniform corrosion.
B. Isolated pitting.
C. Intergranular cracking.
D. Transgranular cracking.
E. Hard and brittle zones.

Which of the following is not a A


major factor associated with
Boiler Water Condensate
Corrosion?
A. Operating pressure.
B. Oxygen content
C. Carbon dioxide content.
D. Process ph
E. Temperature

API 571 Study Guide- Practice Questions for API 570 Exam- Boiler Water...
https://quizlet.com/479814603/api-571-study-guide-practice-questions-for-api-570-exam-boiler-water-condensate-corrosion-435-flash-cards/ 1/3
5/22/2021 API 571 Study Guide- Practice Questions for API 570 Exam- Boiler Water Condensate Corrosion (4.3.5) Flashcards | Quizlet

Protection in a boiler from D


Boiler Feed Water Corrosion is
accomplished by:
A. Injecting chlorines to kill
microbiological bugs.
B. Injecting caustic to lower the
pH to < 4.0.
C. Lowering solids content in
boiler feed water to less than
50 ppm.
D. Maintaining a protective
corrosion layer of magnetite
(Fe3 04).

Carbon Dioxide Corrosion D


usually creates:
A. Uniform corrosion.
B. Isolated pitting.
C. Intergranular cracking
D. Smooth grooving.
E. Hard and brittle zones

What treatment is used to B


prevent Boiler Feed Water
Corrosion?
A. Oxide scavengers are
added to process.
B. Oxygen scavengers are
added to process.
C. Sulfide scavengers are
added to process.
D. Sulfur scavengers are added
to process.

API 571 Study Guide- Practice Questions for API 570 Exam- Boiler Water...
https://quizlet.com/479814603/api-571-study-guide-practice-questions-for-api-570-exam-boiler-water-condensate-corrosion-435-flash-cards/ 2/3
5/22/2021 API 571 Study Guide- Practice Questions for API 570 Exam- Boiler Water Condensate Corrosion (4.3.5) Flashcards | Quizlet

What method is most used to D


assure Boiler Feed Water
Corrosion is not occurring?
A. Spot UT readings at
turbulent areas.
B. Profile RT at turbulent areas.
C. Profile RT at stagnant areas.
D. Laboratory analysis of boiler
feedwater.

https://quizlet.com/479814603/api-571-study-guide-practice-questions-for-api-570-exam-boiler-water-condensate-corrosion-435-flash-cards/ 3/3