Salient Pole Rotor vs. Non-Salient Pole Rotor

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

5/22/2021 Salient pole rotor vs. non-salient pole rotor | electricaleasy.

com

Follow:

Home Electrical Machines Power System Ask A Question Contact

Search
Advertisements

Index Labels Popular posts

Salient Pole Rotor Vs. Non- DCMachines


AC
Basic Machines
construction and working
Salient Pole Rotor Classi
of
DCaMachines
dc cation
generator
of DC machines
DC
Construction
Generatorand working of an
Transformers
By Kiran Daware AC Machines, DC
AC
DC generator or alternator
Motor motors
Induction
Machines, Synchronous Machines Transformers
Starting of DCmachines
motor
Synchronous
How
Speed DC motor works?
Share: Power control
System
Working
Electric principle and types of
braking
Power System Economics
an Induction motor
Rotors of an electrical machine are classi ed More...
Renewable Energy
as: (i) Salient pole rotors and (ii) Non-salient Transformer losses and
AC Machines
Electrical
e ciency
Laws
pole rotors. Both types are explained below.
Working
Basics of induction motors
Di erence between
Salient Pole Rotor 3 phase induction
Miscellaneous motor
machines
synchronous motor and
Starting ofmotor
3 phase IM
Miscellaneous
induction
Speed control
Overhead linesof
Characteristics ofIM
DC motors
Induction
Speed generator
Underground
control cables
methods of DC
Synchronous generator
motor

Advertisement

Popular Posts

Basic construction and working


of a DC Generator.
In salient pole type of rotor consist of large
number of projected poles (salient poles)
mounted on a magnetic wheel.
https://www.electricaleasy.com/2014/03/salient-pole-rotor-vs-non-salient-pole.html#:~:text=Salient pole rotors have large,100 RPM to 1500 RPM.&text… 1/5
5/22/2021 Salient pole rotor vs. non-salient pole rotor | electricaleasy.com

Construction of a salient pole rotor is as


shown in the gure at left. The projected Speed control methods of
poles are made up from laminations of induction motor
steel. The rotor winding is provided on these
poles and it is supported by pole shoes.
Speed control methods of DC
Salient pole rotors have large diameter and
motor
shorter axial length.
They are generally used in lower speed
electrical machines, say 100 RPM to 1500
Characteristics of DC motors
RPM.
As the rotor speed is lower, more number of Characteristics of DC Generators
poles are required to attain the required
frequency. (Ns = 120f / P   therefore, f = Labels
Ns*p/120   i.e. frequency is proportional to
number of poles). Typically number of Power System AC Machines
salient poles is between 4 to 60.
Miscellaneous DC Machines
Flux distribution is relatively poor than non-
salient pole rotor, hence the generated emf Transformer Overhead lines
waveform is not as good as cylindrical rotor.
Induction Motor
Salient pole rotors generally need damper
windings to prevent rotor oscillations during Miscellaneous machines

operation. Underground cables


Salient pole synchronous generators are
Synchronous machines
mostly used in hydro power plants.
Power System Economics
Non-Salient Pole (Cylindrical) Renewable Energy Basics
Rotor
Power Distribution Electrical laws

Advertise with us!

Advertisement

https://www.electricaleasy.com/2014/03/salient-pole-rotor-vs-non-salient-pole.html#:~:text=Salient pole rotors have large,100 RPM to 1500 RPM.&text… 2/5


5/22/2021 Salient pole rotor vs. non-salient pole rotor | electricaleasy.com

Non-salient pole rotors are cylindrical in


shape having parallel slots on it to place
rotor windings. It is made up of solid steel.
The construction of non-salient pole rotor
(cylindrical rotor) is as shown in gure
above. Sometimes, they are also called as
drum rotor.
They are smaller in diameter but having
longer axial length.
Cylindrical rotors are used in high speed
electrical machines, usually 1500 RPM to
3000 RPM.
Windage loss as well as noise is less as
compared to salient pole rotors.
Their construction is robust as compared to
salient pole rotors.
Number of poles is usually 2 or 4.
Damper windings are not needed in non-
salient pole rotors.
Flux distribution is sinusoidal and hence
gives better emf waveform.
Non-salient pole rotors are used in 
nuclear, gas and thermal power plants.