PowerSeries Visual Entry / Exit Delay Annunciation

PC1616 / PC1832 / PC1864

AUX + PGM1 PGM2

B
- C
W

R G
+ N/O
DSC RM-1 + -

Max. Current Draw on PGM2 >300mA

Purpose:
This application provides a strobe light for a visual Entry and Audible Exit Delay
annunciation.

Concerns:
Relays in general have limitation and have a potential for failure.

*** 24 hour Supervisory Buzzer Zone annunciation will trigger the strobe if the
panel is armed.

*** Entry Delay and Exit Delay will trigger strobe for the duration of the delays.

1 of 2
PowerSeries Visual Entry / Exit Delay Annunciation

Programming:
Section Data Reason

[009] 05 PGM1 is programmed as a System Armed Status (05)


- the panel applies power to the RM-1 relay when the system
is armed, this causes the relay to change state and close the
power leg of the strobe. As a result, the strobe will activate
on Entry Delay and Audible Exit Delay once the system is
armed (or begins to arm.)

07 PGM2 is programmed as a Keypad Buzzer Follower (07)


- the panel activates the PGM anytime the panel triggers the
specified KEYPAD BUZZ events listed below. This completes
the power circuit to the strobe.

PGM2 provides up to 300mA @12v DC

*** The Door Chime and Auto-arm Prealert will be blocked when panel is disarmed
by the control PGM1.

*** The 24 hour Supervisory Buzzer Zone will be blocked by the control PGM1 only
when the system is disarmed.

Disclaimer:
This is a design build for a particular application. DSC and/or Daniel Johnson do
not take responsibility for the reliability, operation, functionality or liability of using
the documented procedure. The installer is responsible for testing, verifying and
maintaining the operation.