PowerSeries - Relay Triggered by a *73 Command

PC1616 / PC1832 / PC1864

AUX + PGM1
** The RM-1 provides a N/O circuit on the White and Green leads
** The RM-1 provides a N/C circuit on the White and Yellow leads

B
- C
W

The Normally Open circuit will close when the PGM is activated with *73.
R G
+ N/O
DSC RM-1

Purpose:
This application provides a Normally Open (N/O) trigger to a 3rd party application
in the event a *73 Command (Command Output #3) is activated.

The Command Output #3 can be triggered by either entering *73 on the keypad, or by
pressing a Function Key (2 second hold) on the keypad, or by using a keyfob that has
been programmed to send a *73 remotely via a button press.

Concerns:
Relays in general have limitation and have a potential for failure, thus resulting in
the circuit not working properly.

Caution should be observed if the relay is triggering an action that could cause harm
if the action is unattended or cannot be directly viewed or supervised.

All keyfobs assigned to the partition selected will have the same function key operations.

1 of 2
PowerSeries - Relay Triggered by a *73 Command

Panel Programming:
Section Data Reason

[009] 21 PGM1 is programmed as a (21) Command Output #3

- The panel will activates the PGM anytime the *73 Command is entered.
- PGM1 provides up to 50mA @12v DC of current draw.
- The RM-1 contacts are rated at 2amps @ 30vDC.

The *73 Command can be activated by:


~ Entering [*][7][3] at the keypad
~ Programming a Function Key on the keypad to activate *73
~ Programming a keyfob button to activate *73

* This PGM type can be programmed to require a passcode verification, and / or latch (toggle)
if desired. See PGM Attributes programming (Section 501 - 514.)

Keyfob Programming - Function Key 4 to trigger the *73 Command:


*** The following instruction are for the RF5132-433 v5.0 receiver.
*** Please verify the programming requirements for other versions.

Section Data Reason

[804] [61] 03 Stay Arm


04 Away Arm
27 Disarm
19 Command Output #3 - *73

1 9

Function Key 4 of the WS4939 requires a '3 second press & hold' to activate (default.)
This can be removed by following the installation instructions for the WS4939.

Disclaimer:
This is a design build for a particular application. DSC and/or Daniel Johnson do
not take responsibility for the reliability, operation, functionality or liability of using
the documented procedure. The installer is responsible for testing, verifying and
maintaining the operation.