Log Sheet Water Treatment Plant PLTU MOLOTABU 2 X 12 MW Hari/tanggal :

Time(Hours) Charging Time


System Equipment Measurement Standard
Start Stop
Intake pump 1 atau 2
Pump 1 Preasure (bar)
Pump 2 Preasure (bar)
MMF
Pump 3 Preasure (bar)
1# 2# 3# Flow Output Sesuaikan UF Pool
UFD 1 Flow permeated (m3/jam)
UF Defice
UFD 2 Flow permeated (m3/jam)
UF Pool Level water (meter) 0.5-1.7
Pump 1 Preasure (bar)
UF Pump Pump 2 Preasure (bar)
Pump 3 Preasure (bar)
Flow permeated (m3/jam) 18-21
Flow feed (m3/jam) 48-52
Conductivity feed (µs/cm2)
HP Pump A Conductivity permeated (µs/cm2) <500
pH
Pressure HP Pump (bar) <50
Pressure Motor HP Pump >0.25
RO A/B
Flow permeated (m3/jam) 18-21
Flow feed (m3/jam) 48-52
Conductivity feed (µs/cm2)
HP Pump B Conductivity permeated (µs/cm2) <500
pH
Pressure HP Pump (bar) <50
Pressure Motor HP Pump >0.25
Fresh tank Level water (%)
Flow permeated (m3/jam) 9-11
Flow feed (m3/jam) 13-15
RO C HP Pump 2 Conductivity feed (µs/cm2) <20
pH
Pressure HP Pump 2 (bar) 0.5-1.7
Middle pool Level water (%)
Flow permeated (m3/jam) 9-10
Flow feed (m3/jam) 9-10
Conductivity (µs/cm2) <0.5
Mixed bed 1
pH 8.5-10
Pressure HP Pump 2 (bar)
Regenerasi (check)
Flow permeated (m3/jam)
Flow feed (m3/jam)
Conductivity (µs/cm2) <0.5
Mixed bed 2
pH 8.5-10
Pressure HP Pump 2 (bar)
Regenerasi (check)
Tank 1 Level water (meter) 0.5-3.5
Demin tank
Tank 2 Level water (meter) 0.5-3.5
Sea water tank Level water (%)
Level (meter)
Hidrant/fire fighting
Water pool
Service
Cooling tower
PAC
Chemical tank

NaClO #1
NaOH
Level (1,2,3,4,5,6) sesuai garis tangki
NaHSO3
Anti scalant
NaClO #2
Dicatat oleh : (diisi dengan kode:MSB/RR/HH/SD/SO)
Pengisian bahan kimia (isi dn nomer tangki, lihat petunjuk di buk logistik WTP

Catatan :

Tanda tangan
Tanda tangan
LOOG
SHEET
WTP

PLTU MOLOTABU
FEBRUARI 2021