Sensing Range 30 500 MM Unusable Range 0 30 MM
Sensing Range 30 500 MM Unusable Range 0 30 MM
Sensing Range 30 500 MM Unusable Range 0 30 MM
Technical data
General specifications
Sensing range 30 … 500 mm
Adjustment range 50 … 500 mm
Unusable range 0 … 30 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 380 kHz
Response delay approx. 50 ms
Electrical specification
Operating voltage 10 … 30 V DC, ripple 10 %pp
No-load supply current < 50 mA
• LED green permanent: Power on
flashing: TEACH-IN function object detected
• LED yellow permanent: switching state, switch output
flashing: TEACH-IN function
• LED red normal operation: fault
TEACH-IN function: no object detected
• Use the motor starter’s manual overrides to position the traverse axis
so that the valve body is directly under the ultrasonic sensor.
• Verify the inductive sensor B2 is triggered by the red metal tab on the
carriage.
• Move the traverse axis to the right by pressing motor starter M1’s
manual
override.