Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

SUMMARY

REINFORCEMENT Weight, kg
Concrete Hollow Blocks 540.41
G.I. Wires 32.003
Footing 113.77
Column 474.074
Lateral Ties 216.67
Stirrups 358.025
Slab 1340.78
TOTAL 3075.732

A. REINFORCEMENT OF CONCRETE HOLLOW BLOCKS

Using Area Method


1. Area (L x W)
Left Side: A = 3.05m x 6.7m = 20.435m2
Right Side: A = 3.05m x 6.7m = 20.435m2
Rear Side: Awall = 3.05m x 18m = 54.9m2
Adoors = 2.6m x 0.9m = 2.34m2
Awindows = (1.732m x 3.896m) (2) + (1.732m x 2.025m) + (1.419m x
1.295m) + (6.24m x 1.194m) (2) = 33.74m2
Atotal = Awall - Adoors - Awindows = 54.9 – 2.34 – 33.74 = 18.82m2
Front Side: Awall = 3.05m x 18m = 54.9m2
Adoors = (2.6m x 0.9m) (4) = 9.36m2
Awindows = (1.732m x 2.025m) (4) = 14.03m2
Atotal = Awall - Adoors - Awindows = 54.9 – 9.36 – 14.03 = 31.51m2
Total Area = 20.43 + 20.435 + 18.82 + 31.51 = 91.195m2
2. Refer to Table 3-4
i. Vertical Reinforcement in meters (Spacing: 80 cm)
91.195 m2 x 1.60 = 145.912m long
ii. Horizontal Reinforcement in meters (Spacing Layer: 3)
91.195 m2 x 2.15 = 196.069m long

3. Rebar Weight
d2 L (16)2 (145.912 + 196.069)
W= = = 540.41 kg
162 162

B. TIE WIRE FOR CONCRETE HOLLOW BLOCK REINFORCEMENT

Total Area of the Reinforced Concrete Hollow Blocks = 91.195m2


91.195m2 x 0.024 = 2.189 kg G.I. Wire
C. INDEPENDENT FOOTING REINFORCEMENT

1. F-1 (Quantity: 6)
Concrete Cover: 0.075m
Ln = 0.8m – 2(0.075m) = 0.65m
Reinforcement: 8 pcs of 16mmØ @ 0.65 m long
Nt = 8 x 6 = 48 x 0.65m = 31.2m
31.2m/6m = 5.2 = 6 pcs – 6m long 16mmØ
Rebar Weight
d2 L (16)2 (31.2)
W= = = 49.30 kg
162 162

Tie Wire
16 x 6 = 96 x 0.30 = 28.8m
28.8/53 = 0.543kg of G.I. Wire

2. F-2 (Quantity: 6)
Concrete Cover: 0.075m
Ln = 1m – 2(0.075m) = 0.85m
Reinforcement: 8 pcs of 16mmØ @ 0.85 m long
Nt = 8 x 6 = 48 x 0.85m = 40.8m
40.8m/6m = 6.8 = 7 pcs – 6m long 16mmØ
Rebar Weight
d2 L (16)2 (40.8)
W= = = 64.47 kg
162 162

Tie Wire
16 x 6 = 96 x 0.30 = 28.8m
28.8/53 = 0.543kg of G.I. Wire
D. COLUMN REINFORCEMENT

1. Total Height of Column = 4.65m


2. Reinforcement: C-1 = 4(6) = 24 main bars
C-2 = 6(6) = 36 main bars
3. Total = 24 + 36 = 60 pcs of 5m long, 16mmØ
4. Rebar Weight:
Total length of 16mm main bars = 60(5) = 300m
d2 L (16)2 (300)
W= = = 474.074 kg
162 162

E. LATERAL TIES
1. Spacing of lateral ties
16 x longitudinal bar dia. = 16 x 16mm = 256mm
48 x lateral tie bar diameter = 48 x 10mm = 480mm
Least dimension of the column = 200m

2. 4.65/0.2 = 23.25

3. 23 + 1 = 24 pcs

4. For C – 1: 24 x 6 = 144pcs

For C – 2: 24 x 6 = 144pcs

5. By inspection:
For C-1 = 1m
For C-2 = 1.4m
6. For C-1: 13/1 = 13
For C-2: 13/1.4 = 9.2857 = 9pcs

7. For C-1: 144/13 = 11.076


For C-2: 144/9.2857 = 15.508 = 9pcs
Total = 11.076 + 15.508
= 26.563 = 27pcs of 13 x 10mm bars

8. Rebar Weight

Total length of 10mm lateral ties = 27(13) = 351m


d2 L (10)2 (351)
W= = = 216.67 kg
162 162

F. STIRRUPS FOR BEAM AND GIRDER

a. RG-1:
Total length
Number of stirrups = Spacing
+1
18000(2)+7000(5)
Number of stirrups = + 1 = 356pcs
200
Length of one stirrup for RG-1:
(150 x 2) + (400 x 2) = 1100mm
Prefer to choose 9m steel bars for cutting.
356pcs × 1.1m = 391.6m
391.6m
= 78.32 or 79 pcs of 5m long;10mm diameter bars
5m

b. RG-2:
Total length
Number of stirrups = +1
Spacing
7000(2)
Number of stirrups = + 1 = 71pcs
200
Length of one stirrup for RG-2:
(150 x 2) + (400 x 2) = 1100mm
Prefer to choose 9m steel bars for cutting.
71pcs × 1.1m = 78.1m
78.1m
= 15.62 or 16 pcs of 5m long;10mm diameter bars
5m

c. EB-1:
Total length
Number of stirrups = +1
Spacing
3926.627(4)
Number of stirrups = + 1 = 79.532pcs
200
Length of one stirrup for B1:
(150 x 2) + (250 x 2) = 800mm
Prefer to choose 10.5m steel bars for cutting.
80pcs × .8m = 100m
100𝑚
= 9.52 or 10 pcs of 10.5m long;10mm diameter bars
10.5𝑚

Rebar Weight:
Total length of 10mm steel bars= 79(5) + 16(5) + 10(10.5) = 580m
d2 L (10)2 (580)
W= = = 358.025 kg
162 162

G. REINFORCED CONCRETE SLAB


Size of Reinforcement for temperature bar and main bar: 10 mm Ø
Type of reinforcement: One Way
Bar Spacing: (Assumed because the 400mm spacing in the plan is not included in the
given table) 150mm

Area Method
a. Area = L x W
Area = 18 x 7 = 126 m2

b. Refer to Table 3-8

126 m2 x 2.866 = 361.116 = 362 pcs of 6m long reinforcing bar


362 pcs x 6m =2172 m x 0.6173 = 1340.78 kg
c. Tie Wire, Refer to Table 3-11 (using 15cm bar spacing)

126 m2 x 0.228 = 28.728 kg of GI Wire