Professional Documents
Culture Documents
Roper 2am06
Roper 2am06
Roper 2am06
12 Sizes available:
005 = .0005gpr
01 = 0.001gpr
02 = 0.002gpr
03 = 0.003gpr
06 = 0.006gpr
08 = 0.008gpr
12 = 0.013gpr
16 = 0.017gpr
21 = 0.022gpr
27 = 0.027gpr
32 = 0.033gpr
40 = 0.040gpr
◆ Example: 17AM32
17 indicates flange mount, plain cover
A series
M indicates mechanical seal
32 indicates flow through pump i.e. 0.033gallons per revolution
SERIES: A06
GRAPH 1
THEORETICAL GPM
ACTUAL DELIVERY IN GPM [l/min] = GRAPH 1 - GRAPH 2
14 [53]
12 [45.4]
10 [37.9]
8 [30.3]
6 [22.7]
4 [15.1]
0 [0]
0 200 400 600 800 1000 1200 1400 1600 1800
RPM
GRAPH 2
SLIP
ACTUAL DELIVERY IN GPM [l/min] = GRAPH 1 - GRAPH 2
4 [15.1]
1 [3.8]
.4 [1.51]
.2 [.76]
.04 [.15]
30 [.28]
400 [87.7]
200 [43.3]
100 [20.7]
1000 [220]
2000 [440]
4000 [880]
800 [175.8]
600 [131.8]
6000 [1320]
8000 [1760]
10000 [2200]
1.2 [.89]
1 [.75] ]
.2 kPa
[ 1034
I
PS ]
.8 [.60] 150 kPa
1.8
PS I [86
125 a]
.6 [.45] 89 .5 kP
P S I [6
100
]
[517 . 1 kPa
.4 [.30] 7 5 PS I
DISCHARGE PRESURE
]
44.7 kPa
50 PSI [3
SHOWN ON DIAGONAL LINES
0 [0]
0 200 400 600 800 1000 1200 1400 1600 1800
RPM
VISCOUS HP [kW]
2 [1.5]
.4 [.30]
1 [.75]
.04 [.03]
.1 [.07]
.2 [.15]
4 [2.98]
30 [.28]
40 [4.2]
60 [10.3]
80 [15.5]
100 [20.7]
200 [43.3]
400 [87.7]
600 [131.8]
800 [175.8]
1000 [220]
GRAPH 4
SERIES: A06
900
1200
1800
700 R
4000 [880]
RPM
PM
RPM
RPM
TOTAL INPUT HORSEPOWER [kW] = GRAPH 3 + GRAPH 4
6000 [1320]
8000 [1760]
10000 [2200]
RPM SHOWN ON DIAGONAL LINES
1, 2 AM, AP 06-16