Vishay Telefunken
Applications
RF amplifier up to GHz range specially for wide band antenna amplifier.
Features
D High power gain
D Low noise figure
D High transition frequency
94 9308 13623
1
BFR91 Marking: BFR91
Plastic case (TO 50)
1 = Collector, 2 = Emitter, 3 = Base
Electrical AC Characteristics
Tamb = 25_C, unless otherwise specified
350
0.8
300
250 0.6
200
150 0.4
100
0.2
50
f=1MHz
0 0
0 20 40 60 80 100 120 140 160 0 4 8 12 16 20
12845 Tamb – Ambient Temperature ( °C ) 12893 VCB – Collector Base Voltage ( V )
Figure 1. Total Power Dissipation vs. Figure 3. Collector Base Capacitance vs.
Ambient Temperature Collector Base Voltage
6000 3.5
f T – Transition Frequency ( MHz )
5000 3.0
F – Noise Figure ( dB )
2.5
4000
2.0
3000
1.5
2000
1.0
VCE=5V
1000 VCE=5V f=500MHz
ZS=50W
f=500MHz 0.5
0 0
0 10 20 30 40 50 0 5 10 15 20 25 30
12892 IC – Collector Current ( mA ) 12894 IC – Collector Current ( mA )
Figure 2. Transition Frequency vs. Collector Current Figure 4. Noise Figure vs. Collector Current
S11 S12
j 90°
120° 60°
j0.5 j2
150° 30°
j0.2 2.0 GHz j5 2.0 GHz
ÁÁÁ
ÁÁÁ
ÁÁÁÁÁÁ
1.0
1.0
0
ÁÁÁ
ÁÁÁ
ÁÁÁÁÁÁ
0.2 0.5
0.3
1
0.1
2 5 1 180° 0.1 0.2 0.4 0°
–j0.2 –j5
–150° –30°
–j0.5 –j2
–120° –60°
13 514 –j 13 515 –90°
S21 S22
0.1 90° j
60°
j0.5 j2
ÁÁÁÁ
ÁÁÁÁÁÁ 1
180° 2.0 GHz 8 16 0° 0
ÁÁÁÁ
ÁÁÁÁÁÁ
0.2 0.5 1
2.0 GHz
2
0.5
0.1
5
–j0.2 –j5
–150° –30°
–j0.5 –j2
–120° –60°
13 516 –90° 13 517 –j
96 12244
1. Meet all present and future national and international statutory requirements.
2. Regularly and continuously improve the performance of our products, processes, distribution and operating
systems with respect to their impact on the health and safety of our employees and the public, as well as their
impact on the environment.
It is particular concern to control or eliminate releases of those substances into the atmosphere which are known as
ozone depleting substances ( ODSs ).
The Montreal Protocol ( 1987 ) and its London Amendments ( 1990 ) intend to severely restrict the use of ODSs and
forbid their use within the next ten years. Various national and international initiatives are pressing for an earlier ban
on these substances.
Vishay Semiconductor GmbH has been able to use its policy of continuous improvements to eliminate the use of
ODSs listed in the following documents.
1. Annex A, B and list of transitional substances of the Montreal Protocol and the London Amendments respectively
2 . Class I and II ozone depleting substances in the Clean Air Act Amendments of 1990 by the Environmental
Protection Agency ( EPA ) in the USA
3. Council Decision 88/540/EEC and 91/690/EEC Annex A, B and C ( transitional substances ) respectively.
Vishay Semiconductor GmbH can certify that our semiconductors are not manufactured with ozone depleting
substances and do not contain such substances.
We reserve the right to make changes to improve technical design and may do so without further notice.
Parameters can vary in different applications. All operating parameters must be validated for each customer application
by the customer. Should the buyer use Vishay-Telefunken products for any unintended or unauthorized application, the
buyer shall indemnify Vishay-Telefunken against all claims, costs, damages, and expenses, arising out of, directly or
indirectly, any claim of personal damage, injury or death associated with such unintended or unauthorized use.