0 - Guia Revisión Uniones API
0 - Guia Revisión Uniones API
0 - Guia Revisión Uniones API
Scope
References
IDM Code GDL00382/3 / October 2019
Inspection
1. Inspection criteria for all API connections is as
outlined in API RP 5A5.
2
5. Ensure the pin and box have no dents, tears or
COMPLETE THREAD
IDM Code GDL00382/3 / October 2019
LENGTH
BUTTRESS GENERAL
BOX
PIN
3° 10°
RUNNING MANUAL
TenarisHydril
3
1. The triangle is located at the base of a 1" by 24"
API Buttress Connections
DOPE
4
Thread Lock Application
Make Up
1. API Buttress connection is designed to be made up
to a final position, there is no final torque specified.
5
API Buttress Connections
0.375" (3/8")
(9.525 mm) MAKE UP
TRIANGLE ADMISSIBLE
ZONE
0.200" (5.08 mm)
TOLERANCE
Connection Specific Running Guidelines
6
API Buttress Connections
Connection Specific Running Guidelines
FIELD END MILL END
Running
IDM Code GDL00382/3 / October 2019
7
Pulling
API Buttress Connections
Tenaris has produced this manual for general information only. While every effort has been made to
ensure the accuracy of the information contained within this publication, Tenaris does not assume any
TenarisHydril
responsibility or liability for any loss, damage, injury resulting from the use of information and data
herein. Tenaris products and services are only subject to the Company’s standard terms and Conditions
or otherwise to the terms resulting from the respective contracts of sale, services or license, as the case
may be. The information in this publication is subject to change or modification without notice. For more
complete information please contact a Tenaris’s representative or visit our website at www.tenaris.com.
This manual supersedes Version 03 / March 2018. ©Tenaris 2019. All rights reserved.