Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Customer : ONE Manual : TSM

Type : A318/A319/A320/A321 Selected applicability : 010-010, 058-058


Rev. Date : Aug 01, 2017
27-51-00-810-814-A - FLAP SYSTEM 1 (2) FAULT, No CFDS Message (normal mode)

** ON A/C ALL

TASK 27-51-00-810-814-A
FLAP SYSTEM 1 (2) FAULT, No CFDS Message (normal mode)

1. Possible Causes
· transient fault
· external fault
· VALVE BLOCK-FLAP 1 ( 23CV )
· VALVE BLOCK-FLAP 2 ( 24CV )
· RELAY-FLAP 1 FAULT ( 91CV )
· RELAY-FLAP 2 FAULT ( 93CV )
· SLAT/FLAP CONTR.COMP. ( 21CV )
· SLAT/FLAP CONTR.COMP. ( 22CV )
· aircraft wiring
· SDAC-1 ( 1WV1 )
· SDAC-2 ( 1WV2 )
2 Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment

REFERENCE QTY DESIGNATION


No specific AR MULTIMETER - STANDARD

B. Referenced Information

REFERENCE DESIGNATION
(Ref. 27-51-00-810-802-A). SFCC - FLAP PCU VALVEBLOCK Fault
(Ref. 27-51-00-810-841-A). Wrong Inhibit Sign From Cargo Door Yellow System
Ref. ESPM 20-46-50
Ref. ASM 27-51-02
Ref. ASM 27-51-03
Ref. AMM 27-51-34-000-001 Removal of the SFCC
Ref. AMM 27-51-34-400-001 Installation of the SFCC
Ref. AMM 27-54-00-710-001 Operational Test of the Flap System
Ref. AMM 31-32-00-860-006 Procedure to Get Access to the SYSTEM REPORT/TEST F/CTL Page
Ref. AMM 31-55-34-000-001 Removal of the SDAC
Ref. AMM 31-55-34-400-001 Installation of the SDAC
Ref. AMM 31-60-00-860-001 EIS Start Procedure
Ref. AMM 31-60-00-860-002 EIS Stop Procedure

3. Fault Confirmation

** ON A/C 001-100, 304-350, 401-450


Subtask 27-51-00-740-054-B
A. Fault Analysis
(1) Do a check of the Post Flight Report (PFR):
· if the ECAM Warning message FLAP SYS 1 (2) FAULT is shown without a related FLP 1 (2) CFDS
message, do the next step.

Print Date: June 14, 2018 Page 1 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : ONE Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : 010-010, 058-058
Rev. Date : Aug 01, 2017
27-51-00-810-814-A - FLAP SYSTEM 1 (2) FAULT, No CFDS Message (normal mode)

· if a FLAP 1 (2) CFDS message is shown, do the trouble shooting procedure related to this fault
message.
· if the aircraft is operated with the SFCC channel related to the E/W under MMEL, do step (4).
(2) Do the EIS Start Procedure Ref. AMM 31-60-00-860-001 .
(3) At an MCDU, get access to the SYSTEM REPORT/TEST F/CTL page Ref. AMM 31-32-00-860-006 .
(a) Set F/CTL and get access to the SFCC 1 and SFCC 2 menus.
(b) For each SFCC, set LAST LEG REP FLP and do a check for one or more of the messages that
follow:
· SYSTEM STOP DUE TO LOW PRESSURE
· DC POWER INTERRUPT
· DC POWER BELOW 16 V
· SINGLE MOTOR OPERATION
· LEVER OUT OF DETENT FOR MORE THAN 10 SEC.
· INHIBIT SIGNAL FROM CARGO DOOR YELLOW SYSTEM.

NOTE: These messages are shown in the Last Leg Report (LLR) to help with trouble shooting
when the ECAM Warning message FLAP SYS 1 (2) FAULT is shown because of a tran-
sient fault or external fault .

(c) From the check of the LLR:


· if one or more of the applicable messages are shown, do the related fault isolation procedure:
Para 4.A.'Procedure (If one or more of the applicable Messages are
Shown)'.
· if none of the applicable messages are shown, do the related fault isolation procedure:
Para 4.B.'Procedure (If none of the applicable Messages is Shown)'.

NOTE: If the aircraft was under MMEL, do a check of the Previous Leg Reports (PLR). Use the
fault message which was shown before MMEL opening to do the trouble shooting. Refer
to step (4).

(4) Do a check of the PLR and identify the CFDS message, which was shown before MMEL. Do the
trouble shooting related to this CDFDS message.

** ON A/C ALL
4. Fault Isolation
Subtask 27-51-00-810-063-B
A. Procedure (If one or more of the applicable Messages are Shown)
(1) For the applicable message from the SFCC 1 (2) Flap LLR, do the related procedure step:
· for SYSTEM STOP DUE TO LOW PRESSURE, do step (2)
· for DC POWER INTERRUPT, do step (3)
· for DC POWER BELOW 16V, do step (4)
· for SINGLE MOTOR OPERATION, do step (5)
· for INHIBIT SIGNAL FROM CARGO DOOR YELLOW SYSTEM, do step (6).
(2) SYSTEM STOP DUE TO LOW PRESSURE:
· if the ECAM Warning FLAP SYS 1 (2) FAULT was shown because of a hydraulic low pressure
problem (green or yellow), no more maintenance work is necessary
· if there is no apparent hydraulic system problem, do the next step.
(a) Do the operational test of the flap system Ref. AMM 27-54-00-710-001 .
· if a permanent fault is found do the applicable fault isolation procedure

Print Date: June 14, 2018 Page 2 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : ONE Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : 010-010, 058-058
Rev. Date : Aug 01, 2017
27-51-00-810-814-A - FLAP SYSTEM 1 (2) FAULT, No CFDS Message (normal mode)

· if there is no apparent fault with the flap operation, or the operation is intermittent, do the next
step.
(b) Do the trouble shooting procedure for the applicable VALVE BLOCK-FLAP 1 ( 23CV ) or
VALVE BLOCK-FLAP 2 ( 24CV ) , (Ref. TSM 27-51-00-810-802) .

NOTE: When the hydraulic motor operates, the spool of the control valve is moved and flow oc-
curs. This flow can push particles, in the hydraulic fluid, against the valve block filter and
cause a blockage. If a blockage occurs, the flow decreases and the spool moves back.
This movement of the spool is sensed by the related SFCC, which stops the applicable
hydraulic motor. Flow then decreases and lets the particles become free from the filter.
This removal of the blockage then increases the flow, which moves the spool. This move-
ment of the spool is sensed by the related SFCC, which releases the applicable hydraul-
ic motor. This causes the flow to increase to the condition where a blockage can occur
again. This fault condition can cause the slats to operate intermittently.

(3) DC POWER INTERRUPT:


· if the ECAM Warning FLAP SYS 1 (2) FAULT was shown because of a DC power interrupt, no
more maintenance work is necessary
· if there is no apparent DC power problem, do step (7).

NOTE: The message DC POWER INTERRUPT is shown in the LLR when the DC power is less than
14VDC for more than 40 msec.

(4) DC POWER BELOW 16V:


· if the ECAM Warning FLAP SYS 1 (2) FAULT was shown because the DC power was less than
16.5 VDC, no more maintenance work is necessary
· if there is no apparent DC Power problem, do step (7).

NOTE: The message DC POWER BELOW 16V is shown in the LLR when the DC power is less than
16.5VDC, but more than 14VDC, for more than 20 msec.

(5) SINGLE MOTOR OPERATION:


· if the ECAM Warning FLAP SYS 1 (2) FAULT was shown because the flaps operated momentarily
on one motor only, no more maintenance work is necessary
· if there is no apparent flap motor problem, do step (7).
(6) INHIBIT SIGNAL FROM CARGO DOOR YELLOW SYSTEM.
· if the ECAM Warning FLAP SYS 2 FAULT was shown because the flap operation was prevented
by a Cargo Door fault, no more maintenance work is necessary
· if there is no apparent Cargo Door fault, do the next step.

NOTE: The cargo door inhibit signal is supplied by System 2 only.

(a) At the MCDU set RETURN to go back to the SFCC 2 menu page.
(b) Set CLASS 3 FAULTS FLP and do a check for the message WRONG INHIBIT SIGN FROM
CARGO DOOR YELLOW SYSTEM:
· if the message is shown, do the related trouble shooting procedure (Ref. TSM 27-51-00-810-
841)
· if the message is not shown, do the next step.
(7) Make a record in the aircraft logbook to monitor the operation of the flap system during the next flight.
Subtask 27-51-00-810-108-A
B. Procedure (If none of the applicable Messages Show)

Print Date: June 14, 2018 Page 3 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : ONE Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : 010-010, 058-058
Rev. Date : Aug 01, 2017
27-51-00-810-814-A - FLAP SYSTEM 1 (2) FAULT, No CFDS Message (normal mode)

(1) If the ECAM warning FLAP SYS 1 (2) FAULT is shown, but there is no related CFDS message on the
PFR, or on the SFCC 1 (2) Flap LLR, do step (2).

NOTE: Do not apply this procedure if the aircraft was under MMEL during last leg. Refer to fault isola-
tion to find the applicable trouble shooting procedure.

(2) Remove the applicable flap fault relay 91CV or 93CV and use a MULTIMETER - STANDARD to do a
check at the base of the holder for a ground signal on pin Z and 28VDC on pin X:
· if there is a ground signal on pin Z and 28VDC on pin X, do step (3).
· if there is no ground signal on pin Z, do step (5).
· if there is no 28VDC on pin X, do step (6).
Ref. ASM 27-51-02 or Ref. ASM 27-51-03.
(3) Replace the applicable flap fault relay:
· for a FLAP SYS 1 FAULT message, replace RELAY-FLAP 1 FAULT ( 91CV ) .
· for a FLAP SYS 2 FAULT message, replace RELAY-FLAP 2 FAULT ( 93CV ) .
Ref. ESPM 20-46-50.
(a) Do a check of the upper ECAM DU for the ECAM warning FLAP SYS 1 (2) FAULT:
· if the message shows, do step (4).
· if the message does not show, no more maintenance work is necessary.
(4) Interchange SFCC 1 with SFCC 2, Ref. AMM 27-51-34-000-001 and Ref. AMM 27-51-34-400-001 .
(a) Do a check of the upper ECAM DU for the ECAM Warning FLAP SYS 1(2) FAULT.
(b) If the fault stays in the initial system:
1 Install the SFCCs in their initial positions.
2 Do step (5).
(c) If the fault moves to the opposite system:
1 Install the serviceable SFCC in its initial position.
2 Replace SLAT/FLAP CONTR.COMP. ( 21CV ) or SLAT/FLAP CONTR.COMP. ( 22CV )
that shows the fault.
3 Do a check of the upper ECAM DU for the ECAM warning FLAP SYS 1 (2) FAULT:
· If the message shows, do step (5).
· If the message does not show, no more maintenance is necessary.
(5) Do a check and repair as necessary the aircraft wiring between the applicable C/B and the
applicable fault relay and then between this relay and the applicable SFCC:
· For flap system 1: Do the check between C/B 6CV and relay 91CV and between relay 91CV and
SFCC 1 connector AA pin 2J Ref. ASM 27-51-02
· For flap system 2: Do the check between C/B 8CV and relay 93CV and between relay 93CV to
SFCC 2 connector AA pin 2J Ref. ASM 27-51-03.
(a) If the aircraft wiring is correct and the fault continues:
· Make sure that there is a ground signal on SFCC 1 (2) connector AA pin 3J.
(b) If there is no ground signal and the fault continues:
· Do the check and repair as necessary the aircraft wiring between SFCC 1 (2) connector AA pin
3J and the DC ground point.
(c) If the aircraft wiring is correct and the fault continues:
· Replace SFCC 1 (2) (because the internal connection between pins 2J and 3J is defective)
Ref. AMM 27-51-34-000-001 and Ref. AMM 27-51-34-400-001 .
(d) Do the operational test of the flap system Ref. AMM 27-54-00-710-001 .
(6) Check of SDAC-1 and SDAC-2

Print Date: June 14, 2018 Page 4 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
Customer : ONE Manual : TSM
Type : A318/A319/A320/A321 Selected applicability : 010-010, 058-058
Rev. Date : Aug 01, 2017
27-51-00-810-814-A - FLAP SYSTEM 1 (2) FAULT, No CFDS Message (normal mode)

(a) At SDAC-2: Remove connector AA pin 14A (connector AD pin 14G for flap system 2).
(b) Do a check of the upper ECAM DU for the ECAM warning FLAP SYS 1 (2) FAULT.
(c) If the fault continues:
· For flap system 1: Do a wiring check between SFCC 1 connector AB pin 6D and SDAC-1
connector AA pin 14A.
· For flap system 2: Do a wiring check between SFCC 2 connector AB pin 6D and SDAC-1
connector AD pin 14G.
1 If there is a fault, do the repair.
2 If the wiring is correct, replace SDAC-1 ( 1WV1 ) ,
Ref. AMM 31-55-34-000-001 and Ref. AMM 31-55-34-400-001 .
(d) At SDAC-2: Connect connector AA pin 14A (connector AD pin 14G for flap system 2) again.
(e) Do a check of the upper ECAM DU for the ECAM warning FLAP SYS 1 (2) FAULT:
· if the message does not show, no more maintenance is necessary.
· if the message shows, do step (7)(f).
(f) If the fault continues:
· For flap system 1: Do a wiring check between SFCC 1 connector AB pin 6D and SDAC-2
connector AA pin 14A.
· For flap system 2: Do a wiring check between SFCC 2 connector AB pin 6D and SDAC-2
connector AD pin 14G.
1 If there is a fault, do the repair.
2 If the wiring is correct, replace SDAC-2 ( 1WV2 ) ,
Ref. AMM 31-55-34-000-001 and Ref. AMM 31-55-34-400-001 .
(g) Do the operational test of the flap system Ref. AMM 27-54-00-710-001 and make sure that the
ECAM Warning FLAP SYS 1(2) FAULT does not show on the upper ECAM DU.
5. Close-up
Subtask 27-51-00-942-063-A
A. Put the aircraft back to its initial configuration.
(1) Do the EIS Stop Procedure, if not done before Ref. AMM 31-60-00-860-002 .
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other
items.

End of document

Print Date: June 14, 2018 Page 5 of 5


© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

You might also like