COMPONENT CODE D P

REF NO. AT99115


DATE Jul. 7, 1999
(C) Page 1 of 2

SUBJECT: REPAIR PROCEDURE OF MONITOR PANEL ON PC600/650/750/800/


1100-6

PURPOSE: To introduce modification procedures to repair functional failures which


may occur with the monitor panel on PC600-6 Series, PC750-6 Series,
PC800-6 Series and PC1100-6 Series hydraulic excavators such that
"progress of the service meter reading is too slow" or "the service meter
reading turns back from the previous reading". (The service meter read-
ing lags behind the actual operating hours.)

APPLICATION: PC600-6 Hydraulic Excavators, Serial Nos. 10001 and up


PC600LC-6 Hydraulic Excavators, Serial Nos. 10001 and up
PC650-6 Hydraulic Excavators, Serial Nos. 30001 and up
PC650LC-6 Hydraulic Excavators, Serial Nos. 30001 and up
PC750-6 Hydraulic Excavators, Serial Nos. 10001 and up
PC750LC-6 Hydraulic Excavators, Serial Nos. 10001 and up
PC800-6 Hydraulic Excavators, Serial Nos. 30001 and up
PC800LC-6 Hydraulic Excavators, Serial Nos. 30001 and up
PC1100-6 Hydraulic Excavators, Serial Nos. 10001 and up
PC1100LC-6 Hydraulic Excavators, Serial Nos. 10001 and up

FAILURE CODE: DPA050

DESCRIPTION:

1. Introduction
• With some of the monitor panels being used for the large-sized hydraulic excavators of
PC600-6 and up, functional failures such that "when the starting switch is turned on,
the service meter reading turns back from the previous reading which was appearing
when the starting switch was turned off" or "the service meter reading lags behind the
actual operating hours" may occur.
• When the aforementioned functional failures are found to be occurring, make the
modification following the procedures being outlined in this Service News to replace
the monitor unit with the improved one. After finishing the replacement work, set
the service meter referring to the Service News AT97087.
Remark) The aforesaid failure phenomenon can also occur when the power circuit to the
monitor panel goes out of order but, in this case, the error code "E1:02" will be
memorized in the error history. Therefore, check and make sure the error
code "E1:02" is not being stored in the error history before implementing this
modification.
2. List of parts

Part No. Part Name Purpose of part Q'ty Remarks

7834-77-5001 Monitor  1 PC750-6, PC800-6,


(7834-77-5000) (Monitor)  (1) PC1100-6
 Replacement
7834-76-5001 Monitor  1
PC600-6, PC650-6
(7834-76-5000) (Monitor)  (1)

Printed in Japan AT99115


(02)16
Page 2 of 2

Modification procedures

(Note) Consult the Shop Manual regarding disassembly and reassembly procedures not
being referred to in this Service News.

Replace the monitor unit with the improved one in conformity with the monitor model
designations for respective machine models as shown below.

AT99115