Series GS40
Specifications
Pressure switch with digital display and Accuracy ±3% F.S. (5 to 40°C), ±5% F.S. (–5 to 60°C)
self-contained solid state sensor Voltage 12 to 24 VDC (Ripple ±10% or less)
Minimum allowable pressure indicator on Output Open collector 30 V, 80 mA or less
digital display Light turns ON when pressure drops below the set minimum.
Operating display
Set pressure display
Current consumption 15 mA (24 VDC when ON) or less
SET····Push button
Normally, the LCD displays line pressure. Max. operating pressure 0.98 MPa
When the SET button is pressed the set pres- Operating temperature range –5 to 60°C (No freezing)
sure is displayed. At this time, the user is ca-
pable of determining the difference between Sampling frequency 4 Hz
the line and set pressure. Bracket 15501 — —
Port size M5 x 0.8 (Female thread) R 1/8 R 1/4
Double alarm display
When LINE pressure is within 10% of the current
Mass (g) 42 54 57
minimum allowable setting, the ARROW at the
lower left corner of the LCD flashes.
666
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P0644-P0676-E.qxd 08.8.27 6:15 PM Page 667
Dimensions
14
10
Bracket (Option)
R 1/8,1/4
Dedicated mounting screw
M5 x 0.8 38 (M4 x 0.7) 22 14 (Hex. width across flats) G
26 2 x ø4.5 2 GS
600 ø8
PPA
19
(Lead wire length)
≅ 25
5
8
5
3
36
3
22
22
ø3.2
≅1
M5 type R type
40
- +
P.SET
667
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
P0644-P0676-E.qxd 08.8.27 6:15 PM Page 668
Series GS40
Specific Product Precautions
Be sure to read this before handling.
Refer to front matters 58 and 59 for safety precautions.
Circuit
Vcc D1
Pressure Setting
(+) Brown
Tr D3
Caution
Main circuit (O) Black
(Computer) 1. Pressure setting
While pressing q SET, turn pressure-setting slotted screw e “P.SET”
D2
(–) Blue (counterclockwise to decrease) and watch the LCD. When the LCD
shows the correct figure, stop turning “P.SET” and release the SET but-
Brown wire Connect to DC source (+) (positive) to enable switch ton. Set pressure is displayed on the pressure display panel r LCD.
operation. (Turning clockwise increases the pressure).
Black wire Connect (Switch output) to PLC Input Terminal or DC 2. Alarm display
relay, or other lead. When line pressure drops to within 10% of established minimum allow-
Blue wire Connect to DC source (–) (negatve) to enable switch able pressure, the LCD arrow indicator (on the front side) flashes to in-
operation. dicate the condition. When line pressure drops below the established
D1 Protection diode minimum pressure the red alarm LED labeled w ALM (on the front
D2 Surge supressor (Surge absorbing diode) side) comes ON and is continuously illuminated while the low pressure
D3 Surge supressor (Surge absorbing diode) condition exists.
Tr Output transistor 3. Keep within the maximum operating pressure range. If more pressure
than the maximum allowable operating pressure is applied, LCD dis-
plays “OF” and then it cannot be used. In that case, reset the pressure
Example of wiring and the power source one more time.
Relay, example of wiring for resistant load, etc.
w ALM: Alarm LED (Red)
Vcc D1 Brown (+)
q SET: Push button
Tr D3 Black (O) +
Main circuit Load
(Computer) – SMC DIGITAL PRESSURE SENSOR
D2 Blue (–) SET ALM.
D2 Blue (–)
– Operating Environment
COM
– + Warning
1. Do not use in locations where there is splashing or spraying of oils and
solvents. Since this unit is open type, if water or oil, etc. make an in-
gress etc., the internal circuit may be corroded and result in a mal-func-
tion or damage.
2. Ground the piping when induction noise is expected to be generated
from piping. When the noise is expected from power wire or high pres-
sure wire, install the switch away from the noise.
3. Operating fluid is restricted to air and inert gas. Liquid cannot be used.
4. Absolutely never use in an atmosphere where explosive liquid or gases
are used.
Unit does not have explosion-proof construction. If used in an atmos-
phere of explosive gases, there is a possibility of causing an explosion.