Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

ELECTRONIC CONTROL

Optionals
Without USB
• Pressure switch and transducer input
• USB port for data logging exporting and
configuration importing
With USB • Expanding outputs/inputs using additional ECU
• Embedded or superposed installation
• CAN BUS ECU SAE J1939/1 Wire communication
• Battery voltage monitor
• Mobile phone interface
Characteristics • Bluetooth communication
• 6 Backlighted keys • Hourmeters
• Backlighted graphic display - 128X96 pixels • Custom design
• Configurable parameters • Customer Logo on Display
• Failure control and display • USB extension cable
• Data logger

Technical Information Dimensions


NOMINAL VOLTAGE 12 Vdc ~ 24 Vdc 72,4mm 9,865mm
(2.85 in) (0.39 in)
VOLTAGE RANGE 9 Vdc ~ 30 Vdc
MAXIMUM VOLTAGE 32 Vdc During 5 min.
COMSUMPTION 30mA

42,006mm
(1.65 in)
54mm
MAXIMUM OUTPUT CURRENT 500mA (2.12 in)

OUTPUTS SHORT CIRCUITS Protected


REVERSE POLARITY PROTECTION Protected
CONTROL TEMPERATURE -40°C ~ +80°C/-22ºF ~ +176ºF
OPERATION TEMPERATURE RANGE -40°C ~ +70°C/-40ºF ~ +158ºF
59,008mm
STORAGE TEMPERATURE -40°C ~ +70°C/-40ºF ~+158ºF (2.32 in)
clearance

TEMPERATURE SENSOR NTC 10KW 25° / 77°F


15,00mm
(0.59 in)

PROTECTION DEGREE IP 54
CONNECTORS MICRO-FIT MOLEX
1,365mm
(0.05 in)

COMMUNICATION SERIAL ONE WIRE OR CAN SAE J1939

A P P L I C A T I O N S

www.globuselectronics.com
REFRIGERATION
ELECTRONIC CONTROL
COOLING CONTROL

Part Number GL-P4RGL005


• Configurable defrost function by
RETURN
SENSOR
EXTERNAL
FUSE

time, temperature or differential


temperature - +
12/24VDC
RETURN
TEMP SENSOR

• Evaporator blower output


• Condenser fan output PRESSURE
SWITCH

• Clutch output GND

• Return temperature sensor


• Coil temperature sensor V+ V+ V+ V+

• Defrost output COMPRESSOR DEFROST SOFT START BLOWER

• Soft start output

Part Number GL-P4RGL006 NC


RETURN

• Configurable defrost function by SENSOR

EXTERNAL
time, temperature or differential FUSE

temperature - +
RETURN
TEMP SENSOR

12/24VDC
• Evaporator blower output
• Condenser fan output PRESSURE
SWITCH

• Clutch output GND


• Return temperature sensor
V+ V+ V+ V+
• Coil temperature sensor
• Defrost output COMPRESSOR DEFROST ELECTRIC COMMAND BLOWER

• Electric command enable output

HVAC CONTROL ELECTRONIC CONTROL

Part Number GL-P4HGL003 EXTERNAL


EXTERNAL
TEMP SENSOR

FUSE

• Cooling, heating and auto modes RETURN

• 3 speed blower, clutch, fresh air - +


12/24VDC
TEMP SENSOR

and heating output PRESSURE

• Return temperature sensor SWITCH

GND
• Exernal temperature sensor
• Pressure switch V+ V+ V+ V+

CLUTCH BLOWER HEATING FRESH AIR

www.globuselectronics.com PT0095E REV. 02


CAN
EXTERNAL
FUSE
Part Number GL-P4RGL007
• Configurable defrost function by -
12/24VDC
+
TWISTER
time, temperature or differential
temperature
• Evaporator blower output GND
• Condenser fan output CAN BUS
(SAE - J1939)
• Clutch output NETWORK

• Return temperature sensor


• Coil temperature sensor
ECU
• Defrost output CUSTOMER

• Soft start output


• CAN Bus communication
• USB port
• Data logger

REFRIGERATION
ELECTRONIC CONTROL

COOLING CONTROL

Part Number GL-P7HGL001


RETURN
SENSOR

• Configurable defrost function by EXTERNAL


FUSE

time, temperature or differential


- +
temperature 12/24VDC
RETURN
TEMP SENSOR

• Evaporator blower output


• Condenser fan output GND
PRESSURE
SWITCHES

• Clutch output (OPTIONAL)

• Return temperature sensor V+ V+ V+ V+


• Coil temperature sensor
• Defrost output COMPRESSOR DEFROST SOFT START BLOWER

• Soft start output

www.globuselectronics.com PT0095E REV. 02


ELECTRONIC CONTROL
HVAC CONTROL

Part Number GL-P7HGL001 EXTERNAL


EXTERNAL
TEMP SENSOR

FUSE

RETURN
- + TEMP SENSOR

• Cooling, heating and auto modes 12/24VDC

• 3 speed blower, clutch, fresh air PRESSURE


SWITCH

and heating output GND


• Return temperature sensor
• Exernal temperature sensor V+ V+ V+ V+

• Pressure switch CLUTCH BLOWER HEATING FRESH AIR

ELECTRONIC CONTROL
CAN
Part Number GL-P7HGL001 EXTERNAL
FUSE

• Configurable defrost function by


time, temperature or differential -
12/24VDC
+
TWISTER
temperature
• Evaporator blower output
• Condenser fan output GND

• Clutch output CAN BUS


(SAE - J1939)
NETWORK
• Return temperature sensor
• Coil temperature sensor
• Defrost output ECU

• Soft start output CUSTOMER

• CAN Bus communication


• USB port
• Data logger

www.globuselectronics.com PT0095E REV. 02

You might also like