Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 6

BASE PLATE DESIGN :

fy = 36 ksi
fc' = 2.5 ksi
P 4.83 kip 21.51 KN

Column depth d= 12.44 in 316 mm


web thk. tw = 0.20 in 5 mm
Column flange width bf= 7.87 in 200 mm
flange thk. tf= 0.31 in 8 mm
RCC column A 19.69 in 500 mm
RCC column B 11.81 in 300 mm

A2 = (AXB) A2 = 232.50 in2 if ≥ A2


A1=1/A2(P/0.35f"c)^2 A1 = 0.13 in2
A1 = [P/0.7f"c] or, A1 = 2.76 in2
use larger value A1 = 2.76 in2
∆=[0.5(0.95d-0.8bf)] ∆ = 1.1365
N=sqrt(A1)+∆ N= 2.8 14.4 in 71 mm
B=A1/N B= 1.0 9.8 in 25 mm
A1 = round (BxN) A1 = 141.82528

fp = P/(BxN) fp = 0.0340745

m = 1.2952756
n = 1.7716535
from table or equan : α= 0.325
n' = 3.6436676
take maximum value tp=
tp = 0.0796995 in 2.0243673 mm 6.02
tp = 0.1090115 2.7688914 mm 6.77
tp = 0.2241982 5.6946349 mm 9.69
(4 mm added for weather p
END OF BASE PLATE DESIGN
allowable bearing strength
Fb = 1.25 ksi Fb=0.35f'c when full concrete area coverred
Fb = 0.1362293 ksi Fb=0.35f'c when lessl concrete area coverred
Fb ≥ P/A = 1.75 ksi
(P/0.35f'c)^2 ≤ A1A2 ≤ A1^2
30.503515 642.04988 30.50351
A1 ≥

least padestal area should be (for optimum concrete bearing stress)


A2 ≥ 11.045997

minimum base plate area A1 ≥ P/0.7f'c


A1 ≥ 89.285714
366 A1 ≥ 2.7614993
250 89.29

take maximum value tp=

(4 mm added for weather protection)


275
10
50

b/t = 65/SQRT(Fy) 13.43503 13.75

LOCAL BUCKLING CHECK :

FLANGE
b= 200 mm
tw = 6 mm
b= 102 mm

WEB
b= 200 mm
tw = 4 mm
b= 280 mm
P= 22.52 kip 100 KN
fv = 2.691 ksi (from analysis)
tw = 0.236 in 6 mm
a= 39.370 in 1000 mm
h= 35.433 in 900 mm

fy= 50 ksi

k= 8.58

Cv = 0.3432
0.52471
Fv = 9.0781 ksi < 0.4Fy = 20 ksi
if
PURLIN DESIGN :

yield strength, Fy = 250,000 kN/m2


allowable strength, Fy = 187,500 kN/m2
Bay spacing = 7 m
Purlin spacing = 1.3 m
Purlin thickness = 1.6 mm
roof slope = 5.71 degree 1 10
Ix = 0.00000333 m4
Iy = 0.00000076 m4

IMPOSED LOAD
Live load, LL = 0.57 KN/m2
Weigth of roof sheeting, WR = 4.5 Kg/m2
Purlin mass per unit length, WLMP = 4.9 Kg/m
Colateral load = 0 KN/m2
WdL = 0.1055 kN/m
WLL = 0.741 kN/m

wind pressure pz = 1.140m KN/m2


Design wind pressure on wind ward roof, Pw = 1.48200 KN/m

(DL+LL)COSθ W1x for (DL+LL) = 0.8423 KN/m


DL+LL
(DL+LL)Sinθ W1y for (DL+LL) = 0.0842 KN/m
M = wL2/12 Mx = 3.439 kN-m
My = 0.344 kN-m
σ = Mx.y/Ix+My.x/Iy σ1 = 126,022 KN/m2

WL+DLCOSθ Wx for (DL+WL) = 1.3771 KN/m


DL+WL
DLSinθ Wx for (DL+WL) = 0.0737 KN/m
M = wL2/12 Mx = 5.623 kN-m
My = 0.301 kN-m
σ = Mx.y/Ix+My.x/Iy σ2 = 180,955 KN/m2

σ,max = 180,955 KN/m2

PURLIN DESIGN OK

CHECK FOR DEFLECTION


Elastic modulus, E = 199,949,200 KN/m2 29000 ksi
б= 0.0173 m 5wL4/384EI
б,allow = 0.0389 m span/180

DEFLECTION OK
Design of Purlin

PURLIN DESIGN :

yield strength, Fy = 250,000 kN/m2


allowable strength, Fy = 165,000 kN/m2
Bay spacing = 8.3 m
Purlin spacing = 1 m
Purlin thickness = 3.6 mm

Ix = 0.00000644 m4
Iy = 0.00000146 m4

IMPOSED LOAD
Live load, LL = 0.57 KN/m2
Weigth of roof sheeting, WR = 4.5 Kg/m2
Purlin mass per unit length, WLMP = 4.9 Kg/m
Colateral load = 0 KN/m2
Dead load of Purlin 0.3989727

WdL = 0.0922 kN/m 0.398973


WLL = 0.57 kN/m

wind pressure pz = 1.950m KN/m2


Design wind pressure on wind ward roof, Pw = 1.95000 KN/m

(DL+LL) W1x for (DL+LL) = 0.6622 KN/m


DL+LL

M = wL2/10 Mx = 3.802 kN-m


My = 0.000 kN-m
σ = Mx.y/Ix+My.x/Iy σ1 = 53,166 KN/m2

WL Wx for WL = 1.9500 KN/m


DL+WL
Wx for (WL+DLx) =
M = wL2/10 Mx = 11.195 kN-m
My = 0.000 kN-m
σ = Mx.y/Ix+My.x/Iy σ2 = 156,557 KN/m2

σ,max = 156,557 KN/m2

PURLIN DESIGN OK

CHECK FOR DEFLECTION


Elastic modulus, E = 199,949,200 KN/m2 29000 ksi
б= 0.0318 m 5wL4/384EI
б,allow = 0.0461 m span/180

DEFLECTION OK

You might also like