GRUNDFOS WASTEWATER

S range 1.65 – 5.0 kW


50 and 60 Hz versions
Grundfos

Powerful pumps for handling


unscreened raw sewage
Grundfos offers a complete range of highly
dependable, powerful sewage pumps, designed
> High pump efficiency over time
Advanced technology makes the Grundfos pumps
for handling unscreened raw sewage. With more
extremely efficient and highly dependable. Innova-
than forty years’ experience in providing specia-
lised pumps and pumping equipment for all kinds tive features such as SmartTrim adjustment of the
of wastewater and sewage, we know better impeller clearance ensure long-term high pump
than anyone what our customers demand from efficiency and low life-cycle costs.
a wastewater pump.
> Less down time
The inherent non-clogging design of our SuperVortex
impeller pumps and the excellent solids handling
capability of our channel impeller pumps guarantee
maximum up time and substantial reduction in
service costs caused by pump jamming or clogging.

> Life-long reliability


The Grundfos wastewater pumps are of a well-
proven design that ensures life-long reliability
even under the most difficult operation conditions.

At Grundfos we strive to maintain a close dialogue


with our customers in order to constantly improve
our pump designs and performance. Only this way
are we able to build the long-lasting relationships
on which our business is founded.

2 >
Installation options

Submerged installation on auto-coupling, types S and C


Submerged installation on auto-coupling system requires a base plate with a
90° bend, fixed to the bottom of the pit. When lowered into the pit along the
guide rails, the pump automatically connects to the base plate. The flexible
neoprene SmartSeal ensures a leak-proof connection between the pump and
the auto-coupling.
Type S:
To prevent sedimentation of sludge at intermittent operation, we recommend a
stop level corresponding to the top of the pump housing. For sufficient cooling
at continuous operation, the liquid level must be kept above mid-motor level
at all times.
Type C:
Motor cooling is independent of the pumped liquid level.

Submerged installation, portable, types S and C


Certain applications, such as construction sites, require portable submersibles.
Where a portable submersible is required, hoses of varying lengths and materials
can be supplied.
Type S:
To prevent sedimentation of sludge at intermittent operation, we recommend a stop
level corresponding to the top of the pump housing. For sufficient cooling at con-
tinuous operation, the liquid level must be kept above mid-motor level at all times.
Type C:
Motor cooling is independent of the pumped liquid level.

Vertical dry installation, type D


The Grundfos sewage pumps can be installed vertically or horizontally to suit
specific application arrangements. The pumps are 100% watertight, allowing for
dry installation with the workspace around the pump remaining clean and dry.
If an unexpected flooding should occur, the Grundfos pumps are fully flood-proof.
Motor cooling is effected by internal cooling of the pump.

Horizontal dry installation, type D


Horizontal dry installation improves the overall efficiency of the pumping system
as unnecessary components and bends are avoided. As the system takes up slightly
more space than a vertically installed pump, the feasibility of horizontal dry
installation depends on the floor space available.
Motor cooling is effected by internal cooling of the pump.

3 >
Grundfos SuperVortex impellers

A unique impeller design


The unique design of the Grundfos SuperVortex
impellers provides high pumping efficiency and less
downtime. With a flow range from 4 l/s, the Grundfos
SuperVortex-impeller pumps are the optimum solu-
tion for all small pumping stations.

No clogging or jamming
In a SuperVortex-impeller pump, the flow is entirely
outside the impeller. The design of the impeller en-
sures that long fibres, rags, etc. pass freely through
the pumps without getting caught and without
causing clogging or jamming. This means less down-
time and, consequently, reduced service costs and
higher pumping efficiency.

The design of the SuperVortex-impeller pumps also


prevents the common problem of jamming between
wear rings. A Grundfos SuperVortex- impeller pump
needs no wear rings!

Conventional vortex impeller


In pumps fitted with a conventional vortex impeller,
turbulent disturbance is liable to form around the
impeller. This will disrupt the flow pattern and
result in lower pumping efficiency and reduced head.

Grundfos SuperVortex impeller


The liquid passes freely outside the impeller without
any turbulent disturbance.

Full performance curve without


operating limitations and vibrations
Due to the special power characteristics of the
Grundfos SuperVortex-impeller pumps, it is possible
to run the pumps right up to the maximum flow on
the curves without any risk of overloading the motor.
The steep performance curve means minimal flow
fluctuation with varying heads.

4 SuperVortex >
Grundfos channel impellers

Large free passage for superior solids handling


Compromising on the ability to handle solids in order
to obtain higher pumping efficiency substantially
increases the risk of clogging. More clogging means
more downtime and increased operating costs.
The Grundfos channel-impeller pumps provide high
efficiency and excellent non-clogging capabilities.
The channel impellers are designed with a large
free passage Ø 80 mm.

Self-cleaning impeller
On Grundfos wastewater pumps smaller than
12 kW, the bottom part of the channel impellers
feature specially designed auxiliary vanes. These
vanes are designed to create a powerful flow that
keeps the clearance between the impeller and the
pump housing free from solids or fibres.

Semi-axial impeller design with long vane


The length of an impeller vane is a key factor in
determining the length of fibres that can pass
through a pump without getting caught. The
Grundfos channel impellers are of a semi-axial
design with extra long vanes. This provides maxi-
mum performance and eliminates problems with
fibres or rags getting caught in the impeller.

5 Channel impellers >


Performance overview and general data

Performance overview Type Key


H
[m] ������������ �� �� �� ���� �� �� ���
30 ����������
��� ����������������������
����������������
�������������
20 �� ��������������������������
�� �������������
�������������������
15 �������������������������
�� ��������������
�� ������������������������
10 �����������
�����������������
8 ������������������ �������������������
� � � ������ �����
�� ������� � ����� ����
6 �� ������� � ����� ����
���������������
1 2 3 ��������������������
�� ����������������
4 �� ����������������������
����������������������������������������������������
��������������������������������������
3
����
�������������������������������������������������
������������������������������������
2
2 3 4 5 6 8 10 15 20 30 40 Q [l/s] The S pumps are identified by the type code stated in the confirmation
of order and other documentation supplied with the pump. The code
10 20 30 40 50 60708090 100 Q [m3/h] consist of the items shown in the table below.

1 SuperVortex impeller
ranges 34 – 42 Material specifications
2 SuperVortex impeller
DIN
range 42 Part Material AISI/ASTM
W.-Nr/EN

3 Channel impeller Stator housing Cast iron EN-JL1040 A48 30


range 42 Pump housing Cast iron EN-JS1050 A48 30
Impeller S1 Cast iron EN-JL1040 A48 30
Impeller SV Cast iron EN-JL1040 80-55-06
Operating conditions and Pump Shaft Stainless steel 1. 4460 329
maximum starting frequency Bolts & Nuts Stainless steel 1. 4436 316
Pump application is restricted by the following limits: O-rings NBR - -
• Maximum ambient temperature and pumped O-rings Shaft seal FMK - -
liquid temperature: +40°C Heavy-duty Pre
Bearings - -
lubricated
• Storage temperature range: –30°C to +60°C Primary
• Maximum installation depth: 20 m shaft seal
SiC/SiC - -

• Voltage tolerances: 60 Hz 380 V - +/–10% Secondary


shaft seal
SiC/Carbon - -
50 Hz 400-415 V - +/–10% Lifting bracket Stainless steel 1. 4408 316
Pump starting frequency should not exceed EPDM,
Cables - -
length 10 meter
15 starts per hour.
Cable Entry PA or Cast iron - -
For short periods of time, a starting frequency of Two component
Surface Protection - -
up to double the recommended is permissible. Epoxy
Oil SAE 10 W 30 - -

6 Technical data >


Performance curves

SuperVortex impeller – Range 34 SuperVortex impeller – Range 42


� �
��� SV ��� SV
SV
�� 02
4C
H
50 Hz ��
50 Hz
����������������� �����������������
�� SV0
44D
H
�� ��
SV
024
�� C
�� SV0
34D
H
� SV
01 SV0
4C 44D
��

SV SV0
� 01 �� 34D
4C
L


� � � � � � � � �

� �

� �


� �
� � � � � �� �� �� �� �� �� �� �� ������� � � � �� �� �� �� �� �� �� �������

� �� �� �� �� �� �� �� �� �������� � �� �� �� �� ��� ��� ��������

SuperVortex impeller – Range 42 Single Channel impeller – Range 42


H �
[m] SV ��� S1
SV
24 04 50 Hz 50 Hz
2D ��
ISO 9906 Annex A �����������������
22
��
S1

20
04

SV
4D

03 ��
H

18 2D

16
��
S1

14
0 34

��
DH

12
S1
� 02
10 4D
H

8 �

9 10 �� �� ��
6

4

2

0 �
0 2 4 6 8 10 12 14 16 18 20 22 Q [l/s] � � �� �� �� �� �� �� �� �� �� ���������

0 10 20 30 40 50 60 70 80 Q [m3/h] � �� �� �� �� ��� ��� ��� ��� ��� ��������

7 Performance >
Performance curves

SuperVortex impeller – Range 34 SuperVortex impeller – Range 42


� �
��� SV ��� SV
SV 60 Hz �� 60 Hz
�� 03 ����������������� �����������������
4C
�� ��

SV
05
�� ��

2 D
��
SV �� SV
02
�� 4C 05
4D
�� �� H

��
SV ��

SV
01 SV
� 034

04
4C DH

4D
��

H
� SV ��
01
� 4C
L � � � � �

� � � �
� �

� �



� �
� � � � � �� �� �� �� �� �� �� �� �� ������� � � � �� �� �� �� �� �� �� �������

� �� �� �� �� �� �� �� �� �� �������� � �� �� �� �� ��� ��� ��������

Channel impeller – Range 42



��� S1
�� 60 Hz
�����������������

��
S1

��
05
4D
H

��

��

S1
�� 03
4D
H

� ��


� � �� �� �� �� �� �� �� �� �� �������

� �� �� �� �� ��� ��� ��� ��� ��� ��������

8 Performance >
Technical data

Frame size 34 and 42. Standard and Atex versions


50 Hz 400 – 415 V Installation

Product No. ATEX (A)1)


Product No. Standard

Type S (submerged)
Max. solids (mm)
Starting method

Cable length (m)

Type C (cooled)
Discharge DN
Impeller type
Pump Range
Pump Curve

Type D (dry)
Weight (kg)
Pump type

Inlet DN
P2 (kW)
P1 (kW)

Cos Fi
Poles

IN (A)

IS (A)
SV(A)014CL 1 34 96249067 96249071 2.3 1.7 4 4.4 27.7 0.75 ø80 100 80 74 x x x
SV(A)014C 2 34 96249068 96249072 2.3 1.7 4 4.4 27.7 0.75 ø80 100 80 74 x x x
SV(A)024C 3 34 96249069 96249073 2.3 1.7 4 4.4 27.7 0.75 ø80 100 80 74 x x x
SV(A)024CH* 4 34 96249070 96249074 3.4 2.5 4 5.8 26.7 0.84 ø80 100 80 74 x

SuperVortex
SV(A)034D 5 42 96249118 96249127 3.6 2.9 4 7.0 47.6 0.76 ø80 100 100 105 x x x
Direct on-line (DOL)
SV(A)044D* 6 42 96249119 96249128 3.6 2.9 4 7.0 47.6 0.76 ø80 100 100 105 x
SV(A)034DH 7 42 96249120 96249129 5.3 4.2 4 9.2 46.0 0.84 ø80 100 80 105 x x x
SV(A)044DH* 8 42 96249121 96249130 5.3 4.2 4 9.2 46.0 0.84 10 ø80 100 80 105 x
SV(A)032D 9 42 96249122 96249131 4.4 3.5 2 7.1 58.2 0.89 ø80 100 80 105 x x x
SV(A)042D* 10 42 96249123 96249132 5.9 4.7 2 9.2 58.0 0.92 ø80 100 80 105 x
S1(A)024DH 11 42 96249115 96249124 2.9 2.9 4 7.0 47.6 0.76 ø80 100 100 105 x x x
Channel

S1(A)034DH 12 42 96249116 96249125 2.9 2.9 4 7.0 47.6 0.76 ø80 100 100 105 x x x
S1(A)044DH* 13 42 96249117 96249126 5.3 4.2 4 9.2 46.0 0.84 ø80 100 100 105 x
*) Only to be used for submerged installation. (Version S only).
1) ATEX Aproval IIG / Exd. Temperature Class T4.

60 Hz **) 380 V Installation


Product No. ATEX (A)1)
Product No. Standard

Type S (submerged)
Max. solids (mm)
Starting method

Cable length (m)

Type C (cooled)
Discharge DN
Impeller type
Pump Range
Pump Curve

Type D (dry)
Weight (kg)
Pump type

Inlet DN
P2 (kW)
P1 (kW)

Cos Fi
Poles

IN (A)

IS (A)

SV(A)014CL 1 34 96249092 96249104 2.9 2.2 4 5.5 34.1 0.79 ø80 100 80 74 x x x
SV(A)014C 2 34 96249095 96249107 2.9 2.2 4 5.5 34.1 0.79 ø80 100 80 74 x x x
SV(A)024C 3 34 96249098 96249109 2.9 2.2 4 5.5 34.1 0.79 ø80 100 80 74 x x x
SuperVortex
Direct on-line (DOL)

SV(A)034C* 4 34 96249101 96249112 4.3 3.2 4 7.7 33.9 0.86 ø80 100 80 74 x
SV(A)034DH 5 42 96249191 96249212 4.0 3.3 4 8.1 58.3 0.76 ø80 100 80 105 x x x
10

SV(A)044DH 6 42 96249194 96249215 4.0 3.3 4 8.1 58.3 0.76 ø80 100 80 105 x x x
SV(A))054DH* 7 42 96249197 96249218 6.0 4.8 2 10.8 58.3 0.84 ø80 100 80 105 x
SV(A)052D* 8 42 96249200 96249221 6.3 5.2 2 10.5 70.4 0.92 ø80 100 80 105 x
Channel

S1(A)034DH 9 42 96249182 96249203 4.0 3.3 4 8.1 58.3 0.76 ø80 100 100 105 x x x
S1(A)054DH* 10 42 96249188 96249209 6.0 4.8 4 10.8 58.3 0.84 ø80 100 100 105 x
*) Only to be used for submerged installation. (Version S only).
**) Also availible as 220 and 460 V in 60 Hz version on request.
1) ATEX Aproval IIG / Exd. Temperature Class T4.

9 Technical data >


Dimensions and installation

Dimensions, auto-coupling installation


X
X1
X2

X4

Z1
DN3

U
Z2 Z3
Z
Z4
X3 V

M16 Z5

50 Hz Dimensions [mm]
Pump
Pump type U V X X1 X2 X3 X4 Z Z1 Z2 Z3 Z4 Z5 DN3 Weight
Range
SV(A)014CL 34 775 100 510 358 81 700 11⁄2" 345 171 220 95 160 13 80 74
SV(A)014C 34 775 100 510 358 81 700 11⁄2" 345 171 220 95 160 13 80 74
SV(A)024C 34 775 100 510 358 81 700 11⁄2" 345 171 220 95 160 13 80 74
SV(A)024C 34 775 100 510 358 81 700 11⁄2" 345 171 220 95 160 13 80 74
SV(A)034D 42 805 105 670 520 110 895 2" 413 220 260 110 270 0 100 105
SV(A)044D 42 805 105 670 520 110 895 2" 413 220 260 110 270 0 100 105
SV(A)034DH 42 745 80 645 465 81 840 11⁄2" 345 171 220 95 160 13 80 105
SV(A)044DH 42 745 80 645 465 81 840 11⁄2" 345 171 220 95 160 0 80 105
SV(A)032D 42 770 90 575 425 81 770 11⁄2" 345 171 220 95 160 13 80 105
SV(A)042D 42 770 90 575 425 81 770 11⁄2" 345 171 220 95 160 13 80 105
S1(A)024DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105
S1(A)034DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105
S1(A)044DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105

60 Hz Dimensions [mm]
Pump
Pump type U V X X1 X2 X3 X4 Z Z1 Z2 Z3 Z4 Z5 DN3 Weight
Range
SV(A)014CL 34 775 100 510 358 81 700 11⁄2" 345 171 220 95 160 13 80 74
SV(A)014C 34 775 100 510 358 81 700 11⁄2" 345 171 220 95 160 13 80 74
SV(A)024C 34 775 100 510 358 81 700 11⁄2" 345 171 220 95 160 13 80 74
SV(A)034CH 34 775 100 510 358 81 700 11⁄2" 345 171 220 95 160 13 80 74
SV(A)034DH 42 745 80 645 465 81 840 11⁄2" 345 171 220 95 160 13 80 105
SV(A)044DH 42 745 80 645 465 81 840 11⁄2" 345 171 220 95 160 13 80 105
SV(A)054DH 42 745 80 645 465 81 840 11⁄2" 345 171 220 95 160 0 80 105
SV(A)052D 42 770 90 575 425 81 770 11⁄2" 345 171 220 95 160 13 80 105
S1(A)034DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105
S1(A)054DH 42 780 85 685 520 110 910 2" 413 220 260 110 270 0 100 105

10 Technical data >


Dimensions, free-standing without accessories

J
B1

P
G

T1

ø19 T

50 Hz Dimensions [mm]
Pump
Pump type B1 G J P T T1 Y Weight
Range
SV(A)014CL 34 805 300 515 405 355 130 R3" 74
SV(A)014C 34 805 300 515 405 355 130 R3" 74
SV(A)024C 34 805 300 515 405 355 130 R3" 74
SV(A)024CH 34 805 300 515 405 355 130 R3" 74
SV(A)034D 42 830 300 620 445 355 130 R4" 105
SV(A)044D 42 830 300 620 445 355 130 R4" 105
SV(A)034DH 42 805 300 600 425 355 130 R3" 105
SV(A)044DH 42 805 300 600 425 355 130 R3" 105
SV(A)032D 42 805 300 560 415 355 130 R3" 105
SV(A)042D 42 805 300 560 415 355 130 R3" 105
S1(A)024DH 42 825 300 620 465 355 130 R4" 105
S1(A)034DH 42 825 300 620 465 355 130 R4" 105
S1(A)044DH 42 825 300 620 465 355 130 R4" 105

60 Hz Dimensions [mm]
Pump
Pump type B1 G J P T T1 Y Weight
Range
SV(A)014CL 34 805 300 515 405 355 130 R3" 74
SV(A)014C 34 805 300 515 405 355 130 R3" 74
SV(A)024C 34 805 300 515 405 355 130 R3" 74
SV(A)034CH 34 805 300 515 405 355 130 R3" 74
SV(A)034DH 42 805 300 600 425 355 130 R3" 105
SV(A)044DH 42 805 300 600 425 355 130 R3" 105
SV(A)054DH 42 805 300 600 425 355 130 R3" 105
SV(A)052D 42 805 300 560 415 355 130 R3" 105
S1(A)034DH 42 825 300 620 465 355 130 R4" 105
S1(A)054DH 42 825 300 620 465 355 130 R4" 105

11 Technical data >


Dimensions and installation

Dimensions, dry vertical on base stand

C
E

S
K4
DN4
K3
K
S1 S2
K2

ø19

K1 M16

50 Hz Dimensions [mm]
Pump
Pump type B C E K K1 K2 K3 K4 S S1 S2 DN4 Weight
Range
SV(A)014CL 34 1020 345 219 341 106 136 443 15 255 311 198 100 74
SV(A)014C 34 1020 345 219 341 106 136 443 15 255 311 198 100 74
SV(A)024C 34 1020 345 219 341 106 136 443 15 255 311 198 100 74
SV(A)034D 42 1045 455 300 341 106 136 478 95 255 311 198 100 105
SV(A)034DH 42 1010 480 300 341 106 136 463 95 255 311 198 100 105
SV(A)032D 42 1025 415 260 341 106 136 463 55 255 311 198 100 105
S1(A)024DH 42 1040 470 300 341 106 136 498 95 255 311 198 100 105
S1(A)034DH 42 1040 470 300 341 106 136 498 95 255 311 198 100 105

60 Hz Dimensions [mm]
Pump
Pump type B C E K K1 K2 K3 K4 S S1 S2 DN4 Weight
Range
SV(A)014CL 34 1020 345 219 341 106 136 443 15 255 311 198 100 74
SV(A)014C 34 1020 345 219 341 106 136 443 15 255 311 198 100 74
SV(A)024C 34 1020 345 219 341 106 136 443 15 255 311 198 100 74
SV(A)034DH 42 1010 480 300 341 106 136 463 95 255 311 198 100 105
SV(A)044DH 42 1010 480 300 341 106 136 463 95 255 311 198 100 105
S1(A)034DH 42 1040 470 300 341 106 136 498 95 255 311 198 100 105

12 Technical data >


Dimensions, dry horizontal installation
A1

H DN2

R 3/8

Q2
R
R1
Q1

Q ø19

R2 M16

50 Hz Dimensions [mm]
Pump
Pump type A1 H Q Q1 Q2 R R1 R2 DN2 Weight
Range
SV(A)014CL 34 675 100 130 220 439 190 95 15 80 74
SV(A)014C 34 675 100 130 220 439 190 95 15 80 74
SV(A)024C 34 675 100 130 220 439 190 95 15 80 74
SV(A)034D 42 700 135 190 220 520 190 95 15 100 105
SV(A)034DH 42 665 120 130 220 520 190 95 15 80 105
SV(A)032D 42 680 110 130 220 480 190 95 15 80 105
S1(A)024DH 42 695 155 130 220 520 190 95 15 100 105
S1(A)034DH 42 695 155 130 220 520 190 95 15 100 105

60 Hz Dimensions [mm]
Pump
Pump type A1 H Q Q1 Q2 R R1 R2 DN2 Weight
Range
SV(A)014CL 34 675 100 130 220 439 190 95 15 80 74
SV(A)014C 34 675 100 130 220 439 190 95 15 80 74
SV(A)024C 34 675 100 130 220 439 190 95 15 80 74
SV(A)034DH 42 665 120 130 220 520 190 95 15 80 105
SV(A)044DH 42 665 120 130 220 520 190 95 15 80 105
S1(A)034DH 42 665 155 130 220 520 190 95 15 100 105

13 Technical data >


Accessories

DN DN Product
Pos. Picture Description Dimensions
80 100 number

DN 80 • 96090993
Auto-coupling system complete
with guide claw, base plate and
1 upper guide-rail holder. DN 80/DN 100 • 96102240
With gaskets and bolts.Cast iron,
epoxy-coated. DN 100 • 96090994

DN 80/DN 80/3" • 96102254


Ring stand with flanged 90° elbow
and hose connection.
DN 100/DN 80/3" • 96102313
With bolts, nuts, gaskets and
anchor bolts.Cast iron, epoxy-coated.
DN 100/DN 100/4" • 96102255
2
DN 80/DN 80/R 3 • 96102381
Ring stand with flanged 90° elbow
and outside thread connection.
DN 100/DN 80/R 3 • 96102382
With bolts, nuts, gaskets and
anchor bolts.Cast iron, epoxy-coated.
DN 100/DN 100/R4 • 96102383

Base stand for vertical dry installation,


including 90° elbow.
3 DN 100 • 96102259
With bolts, gaskets and anchor bolts.
Galvanized steel.

Bracket for horizontal dry installation.


4 With bolts, gaskets and anchor bolts. DN 100 • 96255509
Galvanized steel.

10° adaptor with lift function for • 96572290


5 Grundfos base plate UV 35579 incl.
guide claw, bolt, nuts and gasket. • 96294872

Adaptor for Grundfos base plate • 96572291


6 UV 35586 B incl. guide claw, bolt,
nuts and gasket. • 96572292

Lifting chain with shackle.


7 6m • • 96497465
With certificates. Galvanized steel.

AMD.07.18.1410 mixer for Contact


8
flushing in pump sump. Grundfos

14 Accessories >
The Grundfos wastewater range

S range 5 – 29 kW S range 15 – 155 kW


Brochure covers the Grundfos range of Brochure covers the Grundfos range of
submersible channel-impeller pumps sewage pumps from 15 kW up to 155 kW
from 5 kW up to 21 kW and Super-Vortex for handling of raw sewage in
pumps up to 29 kW. All designed for heavy-duty applications.
handling unscreened raw sewage. Available in 50 Hz and 60 Hz versions.
Available in 50 Hz and 60 Hz versions.

S/SA ranges up to 520 kW SE range 90–220 kW


Brochure covers the Grundfos range of Brochure covers the Grundfos range of
super-heavy-duty channel pumps, axial updated heavy-duty submersible sewage
flow pumps, and propeller pumps from pumps. Includes descriptions of the new
7.5 kW up to 520 kW. built-in sensors.

SRP range 3.0 – 24 kW SEN range 1.0 – 21 kW


Brochure covers the Grundfos range of SRP Brochure covers the Grundfos range of
submersible recirculation pumps for waste- heavy-duty stainless steel pumps (SEN) for
water treatment plants and flood control. aggressive and corrosive environments.
Available in 50 Hz and 60 Hz versions.

Multilift M, MD, MDV, LC/LCD Ranges – level controllers


and MD1 ranges Brochure covers the Grundfos range of
Brochure covers Grundfos lifting stations controls for the wastewater pumping
for individual as well as multi-user systems.
applications.

AMD, AMG, and AFG ranges SEG range 0.9 – 4.0 kW


Brochure covers the new range of mixers Brochure covers the Grundfos range of
and flowmakers for optimal control of sewage grinder pumps (SEG) for pumping
liquids and solids throughout the of wastewater with toilet discharge.
wastewater treatment process.

DP, EF, SE1 and SEV ranges Prefabricated pumping stations


0.6 – 2.6 kW Brochure covers the Grundfos range of
Brochure covers the Grundfos range of prefabricated pumping stations for
submersible channel-impeller and Super- collecting and removing drainwater,
Vortex-impeller pumps from 0.6 to 2.6 kW. surface water, domestic and industrial
Designed for handling drainage, effluent wastewater and sewage.
and sewage from private dwellings.

SE1 and SEV ranges 1.1 – 11 kW


This brochure describes the innovative
SEV/SE1 pump lines. Fitted with Super-
Vortex or single-channel impellers,
these pumps can meet approximately
80% of all wastewater pumping needs.

15 The range >


Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

Business with an attitude


Knowledge The sharing of knowledge, experience
and expertise across our global network will always
lead our business forward.

Innovation Combining the best technology with


fresh ways of thinking, we will continue to develop
even better pumps, systems, services and standards.

Solution With a complete product range, capable


of providing every conceivable water solution, we are
the most complete player on the market.

VENTURE I/S
96610947 0606

www.grundfos.com