Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

THIRD FLOOR BEAM DESIGN CALCULATION

Group : G1
Beam No : B1
Analysis Reference (Member) 7.7m : 30
Beam Length : 5000 mm
Breadth (B) : 250 mm
Depth (D) : 350 mm
Effective Depth (d) : 300 mm
Design Code : ACI 318M - 2011
Beam Type : Ductile Beam (Special Frame)
Grade Of Concrete (f'c) : C21 N/sqmm
Grade Of Steel : Fy230 N/sqmm
Clear Cover (Cmin) : 40 mm
Es : 2x10^5 N/sqmm
Mubal : 458.56 kNm
As,min (flex) (B) : 340.91 sqmm
As,nominal (Bn) : 97.5 sqmm
As,min(user input)(B') : 97.5 sqmm

For Longitudinal Reinf


Beam Bottom Beam Top
Left Mid Right Left Mid Right
Critical L/C - Analysis 11 7 17 9 15 7
Critical L/C - RCDC 7 3 13 5 11 3
Mu (kNm) 27.7 39.2 21.07 80.41 15.66 86.87
As (flex) (sqmm) (C) 188.06 267.06 142.77 554.75 105.97 600.54
Asc (flex) (sqmm) (A) - - - - - -
Tu (kNm) 1.55 1.56 0.46 0.06 1.16 1.56
Tcr/4 (kNm) 3.97 3.97 3.97 3.97 3.97 3.97
Al, min(sqmm)(Tor.) - - - - - -
Al (sqmm) (Tor.) (E) - - - - - -
Al (Dist) (sqmm) (D) - - - - - -
Ast (sqmm) 250.12 340.91 301.59 554.75 140.94 600.54
AstPrv (sqmm) 402.12 402.12 402.12 603.18 339.3 603.18
Reinforcement 2-#16 2-#16 2-#16 3-#16 3-#12 3-#16
Note: Calculation of Ast

Ast = Max {B, C+D, A+D} (for Mu > 0 and C x 1.33 > B)
Ast = Max{B', C x 1.33 + D, A+D} (for Mu > 0 and C x 1.33 < B)
Ast = Bn (for Mu = 0)
Where,
Compression reinforcement required for
A = Asc (flex) =
bending moment
B = As,min (flex) = Min area of flexural reinforcement
Bn = As,nominal = Nominal area of reinforcement
Total area of longitudinal reinforcement
C = As (flex) =
calculated at a given section
Distributed longitudinal torsional
D = Al (Dist) =
reinforcement at section considered
Max(Al,min (Tor), Al (Tor)) x ((2B) / (2B +
Ast (Dist) (sqmm) =
2D))

For Transverse Reinf


Left Mid Right
Critical L/C - RCDC 1 1 1
PtPrv (%) 0.804 0.804 0.804
Vu (kN) 49.48 38.31 51.92
Mu-Sect (kNm) 35.88 4.01 41.98
VD+L (kN) 42.21 0 42.08
Mh (kNm) 120.36 0 120.36
Ms (kNm) 81.14 0 81.14
Sway-Right (kN) 0.67 0 84.95
Sway-Left (kN) 85.08 0 0.79
Vu-Sway (kN) 85.08 0 84.95
Vud (kN) 85.08 0 84.95
Φ Vc (kN) 62.31 65.91 62.04
Vs (kN) - - -
Av (sqmm/m) 369.05 369.05 369.05
Tu (kNm) 0.73 0.73 0.73
Aoh (sqmm) - - -
At (sqmm/m) - - -
Legs 2 2 2
Stirrup Rebar 10 10 10
At Torsion (sqmm/m) 0 0 0
Av Total Reqd (sqmm/m) 369.05 369.05 369.05
Asv Reqd (sqmm/m) 369.05 369.05 369.05
SCalc (mm) 75 115 75
SPrv (mm) 75 115 75
Av Total Prv (sqmm/m) 2094.4 1365.91 2094.4
Maximum Spacing Criteria

Basic
Spc1 = 150 mm
Spc2 = 300 mm
For Torsion
(X1 = 180, Y1 = 280)
Spc3 = 300 mm
Spc4=(X1+Y1)/4 = 115 mm

For Ductility (Special Frames)


Left Section, Right Section

=
Spc5 = 6 x Small Longitudinal Dia 96 mm
Spc6 = d / 4 = 75 mm
Spc7 = 150 mm
Provided Spacing = 75 mm

Mid Section
Provided Spacing = 150 mm

Skin reinforcement

Beam Width = 250 mm


Beam Depth = 350 mm
Depth = 350 <= 900, Hence Skin Reinforcement is not required.

Group : G1
Beam No : B2
Analysis Reference (Member) 7.7m : 31
Beam Length : 1500 mm
Breadth (B) : 250 mm
Depth (D) : 350 mm
Effective Depth (d) : 300 mm
Design Code : ACI 318M - 2011
Beam Type : Cantilever Beam
Grade Of Concrete (f'c) : C21 N/sqmm
Grade Of Steel : Fy230 N/sqmm
Clear Cover (Cmin) : 40 mm
Es : 2x10^5 N/sqmm
Mubal : 458.56 kNm
As,min (flex) (B) : 340.91 sqmm
As,nominal (Bn) : 97.5 sqmm
As,min(user input)(B') : 97.5 sqmm
For Longitudinal Reinf
Beam Bottom Beam Top
Left Mid Right Left Mid Right
Critical L/C - Analysis - - - 14 14 14
Critical L/C - RCDC - - - 10 10 10
Mu (kNm) - - - 3.29 1.85 0.21
As (flex) (sqmm) (C) - - - 22.2 12.48 1.39
Asc (flex) (sqmm) (A) - - - - - -
Tu (kNm) - - - - - -
Tcr/4 (kNm) - - - - - -
Al, min(sqmm)(Tor.) - - - - - -
Al (sqmm) (Tor.) (E) - - - - - -
Al (Dist) (sqmm) (D) - - - - - -
Ast (sqmm) 97.5 97.5 97.5 97.5 97.5 97.5
AstPrv (sqmm) 226.2 226.2 226.2 603.18 603.18 603.18
Reinforcement 2-#12 2-#12 2-#12 3-#16 3-#16 3-#16

Note: Calculation of Ast

Ast = Max {B, C+D, A+D} (for Mu > 0 and C x 1.33 > B)
Ast = Max{B', C x 1.33 + D, A+D} (for Mu > 0 and C x 1.33 < B)
Ast = Bn (for Mu = 0)
Where,
Compression reinforcement required for
A = Asc (flex) =
bending moment
B = As,min (flex) = Min area of flexural reinforcement
Bn = As,nominal = Nominal area of reinforcement
Total area of longitudinal reinforcement
C = As (flex) =
calculated at a given section
Distributed longitudinal torsional
D = Al (Dist) =
reinforcement at section considered
Max(Al,min (Tor), Al (Tor)) x ((2B) / (2B +
Ast (Dist) (sqmm) =
2D))
For Transverse Reinf
Left Mid Right
Critical L/C - RCDC 1 1 1
PtPrv (%) 0.804 0.804 0.804
Vu (kN) 4.33 2.89 1.44
Mu-Sect (kNm) 3.25 1.44 0.36
Φ Vc (kN) 77.78 79.32 82.39
Vs (kN) - - -
Av (sqmm/m) 369.05 369.05 369.05
Tu (kNm) 0 0 0
Aoh (sqmm) - - -
At (sqmm/m) - - -
Legs 2 2 2
Stirrup Rebar 10 10 10
At Torsion (sqmm/m) - - -
Av Total Reqd (sqmm/m) 369.05 369.05 369.05
Asv Reqd (sqmm/m) 369.05 369.05 369.05
SCalc (mm) 150 150 150
SPrv (mm) 150 150 150
Av Total Prv (sqmm/m) 1047.2 1047.2 1047.2

Maximum Spacing Criteria

Basic
Spc1 =d/2 = 150 mm
Spc2 = 300 mm

Skin reinforcement

Beam Width = 250 mm


Beam Depth = 350 mm
Depth = 350 <= 900, Hence Skin Reinforcement is not required.

You might also like