PRODUCT DATA SHEET

EAZY BWT-1
Product Code: 1001 Product Group: Water Treatment
Packaging: 25L Issue/Date: 1.30 - 29/11/2007

PRODUCT DESCRIPTION
eazy BWT-1 is a uniquely blended liquid boiler treatment programme designed to inhibit scale
formation and corrosion within the boiler circuit. The product contains additives to inhibit scale when
hard water breakthrough occurs, inhibit corrosion in the boiler circuit as well as the condensate lines
and scavenge minor traces of oil. The conditioned feed water will form a loose, non-adhering sludge
that can easily be removed by blow down.

The polymeric phosphate dispersants and corrosion inhibitors meet FDA requirements and the product
does not contain hydrazine.

APPLICATION & USE


It is recommended that product be used with good quality feed water and dosed into the feed water
line after the feed water re-circulation off take. This should be done by diluting with distilled water or
condensate and dosed over a 24 hour period.

DIRECTIONS FOR USE


Dosage:
Initial dosage depends on the prevailing boiler condition and the quality of the feed water. In general
the dosage rate should be 2.5 to 5.0 litres per tonne of water.

Maintenance dosage should be 0.5 to 2.5 litres per day depending on test results.

Testing:
Eazychem boiler water test kits are used to monitor dosage and control parameters. These simplified
tests are listed on the dosage and control charts. It is recommended that regular testing be carried
out to ensure that levels of treatment and control are correct.

Blow Down:
Blow down may be necessary to reduce the amount of dissolved and suspended solids. This should be
done in accordance with the boiler manufacturer’s instruction.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY CWT-DE
Product Code: 1101 Product Group: Water Treatment
Packaging: 25L Issue/Date: 1.40 - 29/11/2007

PRODUCT DESCRIPTION
eazy CWT-DE is an easy to use and effective liquid corrosion inhibitor and treatment for diesel engine
cooling water systems, protecting them from corrosion and hard water scale.

Product has no detrimental effects on non-metallic system components such as seals, glands, hoses
or gaskets and is compatible with glycol-based antifreeze products.

APPLICATION & USE


Product is an effective corrosion inhibitor for both ferrous and non-ferrous metals in marine circulating
cooling water systems.

Prior to the addition of product sacrificial anodes (e.g. magnesium or zinc) in the cooling system
should be removed.

Note: Please contact Eazychem before using this product in systems containing aluminium alloys as
product may not be suitable.

DIRECTIONS FOR USE


Dosage
Good quality fresh or distilled water should be used to fill the cooling water system. The
recommended initial dosage is 10 litres per tonne of system capacity.

The initial treatment should be dosed into a suitable point in the cooling system and circulated for one
hour to ensure even distribution. For advice contact Eazychem.

Testing and Control


The correct concentration of product treatment should be maintained using Eazychem cooling water
test kits.

Testing should be carried out once per week to ensure that a minimum level of nitrite is maintained.
This should be 900 to 1400ppm as nitrite (NO2) and logged onto the control and dosage chart.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY MUDSOLV-C
Product Code: 1121 Product Group: Water Treatment
Packaging: 25L Issue/Date: 1.40 - 29/11/2007

PRODUCT DESCRIPTION
eazy Mudsolv-C is a concentrated and completely safe ballast water treatment specially formulated to
condition, remove and prevent the build up of silt and mud deposits.

APPLICATION & USE


Product can be effectively used in ballast tanks, cooling water systems and pipe lines and is also an
efficient antiscalant. Benefits of using product can include reducing the environmental risk of
transporting invasive marine species locked into mud deposits, maintaining optimum cargo carrying
capacity and stability, reducing the potential for corrosion and for survey or inspection purposes
avoiding the costly exercise of ‘mucking out’ and disposal.

DIRECTIONS FOR USE


In order to obtain optimum results product should be dosed into the filling line of the ballast or cooling
system at predetermined rates prior to the systems being filled in order to ensure product is
thoroughly dispersed. The loose deposits of silt and mud are easily discharged during deballasting.

The normal dosage rate for maintenance purpose is 1 litre per 20 tonnes of ballast water and the
treatment should be repeated each time the ballast tank or cooling system is filled.

In the case of existing accumulations, a dosage rate of 1 litre per 10 tonnes of ballast water is
recommended and should remain in the tank for at least 24 hours. It should be noted that depending
on the degree of mud accumulation it may take several treatments before any significant reduction is
achieved.

For severe mud build up results will be obtained in a shorter period if aided by direct
agitation/mechanical action prior to ballasting. This will allow product to penetrate more easily
following the next ballasting operation.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY MMBD
Product Code: 1201 Product Group: Water Treatment
Packaging: 25L Issue/Date: 1.30 - 29/11/2007

PRODUCT DESCRIPTION
eazy MMBD is liquid seawater dispersant to prevent marine growth adhering to surfaces in seawater
cooling systems. It will keep the system free from microbiological and macro biological growth thus
ensuring that the cooling capacity operates at maximum efficiency.

APPLICATION & USE


As this product is a marine growth preventative, it is essential that the cooling system be cleaned
prior to the beginning of any treatment program. For advice please contact Eazychem.

N.B. This product will disperse new growth but not existing growth.

Product should be dosed to the seawater cooling systems on a regular basis in order to maintain
optimal heat transfer condition and system cooling capacity.

DIRECTIONS FOR USE


Product should be mixed at a rate of 0.5 liters per 100 tonnes of water flow and fed by means of a
gravity tank and flow meter or eductor unit, to the external sea chest, for a period of one hour. The
dosage frequency will be dictated by the trading conditions.

Vessels which operate continuously in coastal waters should dose every three days. Vessels which are
ocean going should dose once per week and every two days when in coastal waters.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY VAPCARE
Product Code: 1301 Product Group: Water Treatment
Packaging: 25L Issue/Date: 1.30 - 29/11/2007

PRODUCT DESCRIPTION
eazy VapCare liquid evaporator treatment is a blend of polymers and antifoaming agents used to
prevent scale deposition in both high and low-pressure evaporators.

Product is easily dosed, economical to use and safe for potable water applications.

APPLICATION & USE


Product prevents the scale forming minerals in seawater from depositing on the heat transfer areas
and impairing the efficiency of the equipment. Gradual removal of low levels of existing scale deposits
can also be achieved. The removed solids are held in suspension and as such flushed from the system
with the evaporator brine discharge.

The antifoaming properties prevent foaming and any potential carry over.

Use of this product ensures that the operating efficiency of the plant will be maintained for maximum
water production.

DIRECTIONS FOR USE


Product should be diluted with fresh or seawater and fed continuously to the evaporator by means of
a dosing pump or flow meter.

The recommended dosage rate for product is 30mls per tonne of water.

Note: eazy Descaler Plus is recommended for the removal of existing high levels of scale
prior to commencing the treatment.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY ASH CONTROL
Product Code: 1807 Product Group: Fuel Treatment
Packaging: 25L Issue/Date: 1.40 - 22/10/2007

PRODUCT DESCRIPTION
eazy ASH Control is a unique blend of combustion catalysts, ash deposit modifiers and corrosion
inhibitors. It has been specially formulated for use in engines, both medium and slow speed, where
the presence of deposits in valves seats and turbocharger blades pose serious problems.

This product has been formulated to solve problems related to combustion as well as those caused by
high vanadium oxides, sulphur and sodium salt contaminants in the fuel.

Product is miscible in fuel, does not react with any other substances and is not affected by fuel
centrifugal separation.

APPLICATION & USE


The benefits of using the product are:

• Prevents high temperature corrosion by increasing the sodium sulphate and vanadium
pentoxide melting points from 675/880ºC respectively to around 1100ºC
• Minimises low temperature acid corrosion and reduces lube oil TBN (alkalinity) caused by the
presence of sulphur (sulphuric acid)
• Improves combustion efficiency and reduces fuel combustion
• Reduces smoking and emissions
• Reduces engine wear
• Improves combustion considerably by reducing carbon deposits
• Promotes lower fuel consumption

Deposit Ash Modifier


Due to the presence of the deposit modifiers, these prevent high and low temperature corrosion in the
high temperature surfaces such as valve seats and stems, thus prolonging the machinery parts life.
This is achieved by raising the melting point of the vanadium compounds, by transforming the
crystalline form of the ash making it light and friable so that it is easily exhausted.

By inhibiting the vanadium so that it cannot act as a catalyst in the oxidation process of SO2 to SO3,
this reduces considerably the sulphuric acid formation and minimises low temperature corrosion.

There have been cases that show use of this product has resulted in appreciable reductions of sulphur
trioxide by more than 70%.

Combustion Improver
The oil soluble organo-metallics that are present in the product, apart from enlarging the combustion
area and being effective in a better fuel-oxygen mixing, achieve a rapid oxidation of carbon in the fuel
thus improving combustion.

The combustion improver, together with the deposit modifier provides a synergistic effect and
prevents the buildup of deposits.

Furthermore, the ignition energy required to complete the combustion is dropped and so less carbon
deposits are formed.

DIRECTIONS FOR USE


Methods
Product can be introduced manually into the fuel tanks prior to or during bunkering. The fuel
movement on entering the tank will blend the product with the fuel.

It is preferable to introduce product by the use of a metering pump into the fuel line prior to the
suction of the low pressure feed pump in order to achieve optimum mixing and ensure that product is
fed continuously into the fuel. Depending on the engine design the dosing location may vary.

Dosage
The typical dosage rate for product is in the range of 1:1,000 liters to 1:8,000 liters of fuel. Rates
vary depending on the engine design, operating conditions and contaminant level in the fuel.

The following table shows appropriate dosage rate.


DIRECTIONS FOR USE cont’d

Contaminant Contaminant Level Treatment Rate


-------------------------------------------------------------------
Vanadium Up to 150ppm 1/6000
150-250ppm 1/4000
250-350ppm 1/2000
350ppm and over 1/1000

Sodium Up to 15ppm 1/8000


15-30ppm 1/6000
30ppm and over 1/4000

Sulphur Up to 1.5% 1/8000


2.5 to 3.5% 1/2000
3.5% and over 1/1000

Carbon Residue Up to 10% 1/6000


10% to 15% 1/4000
15% to 18% 1/3000
18% and over 1/2000

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY AUTOTREAT
Product Code: 1825 Product Group: Fuel Treatment
Packaging: 25L Issue/Date: 1.10 - 12/02/2005

PRODUCT DESCRIPTION
eazy AutoTreat is a specialist formulation designed to treat fuel systems in vehicles, marine, domestic
and industrial applications including permanent and temporary fuel storage tanks.

Light and medium grade fuels are particularly susceptible to microbiological growth as they provide a
source of food for bacteria. Moisture (water) in the tank provides the perfect condition necessary to
trigger growth through water contamination during storage or transportation, condensation due to the
natural warming and cooling of the tank or from leakage into the bunker tank.

APPLICATION & USE


Product will clean dirty injectors and fuel lines in both diesel and petrol systems. It mixes readily in
seconds giving an instant result.

Benefits include:

• Allows water to be absorbed into the body of the fuel (dispersion)


• Softens and dissolves gum, varnish and wax formed on metal surfaces
• Prevents waxing and fungal/bacterial growth
• Burns off with minimal residue
• Removes source of corrosion
• Does not contain kerosene or diesel
• Will not damage catalytic converters

DIRECTIONS FOR USE


Depending on the prevailing conditions in the tank, product should be dosed at 1 litre per 500 litres
(up to 1,000 litres) of fuel in order to absorb the free moisture. If water in fuel is a long term issue,
we highly recommend dosing on a continual basis during bunkering either manually or preferably
using an automated dosing system (contact us for further assistance and advice).

Note: Slight overdosing will not affect the fuel.

In systems already contaminated with “bugs” we highly recommend treating the system with eazy
MicroTreat prior to using this product.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY COMBUSTION IMPROVER
Product Code: 1804 Product Group: Fuel Treatment
Packaging: 25L Issue/Date: 1.30 - 22/10/2007

PRODUCT DESCRIPTION
eazy Combustion is the latest development of a fuel oil treatment acting as a combustion improver,
carbon catalyst, ash deposits modifier and smoke suppressant for diesel engines and boilers.

Product is in liquid form containing speciality solvents, emulsion breakers, anti-oxidants, anti-
corrosive agents, combustion catalysts, inhibitors, dispersants and ash modifiers. It is easily soluble in
all types of fuel.

Benefits of using the product include:

• Increased combustion efficiency


• Reduced carbon buildup in combustion zones
• Inhibited formation of carbonaceous ash deposits in exhaust and scavenging ports
• Minimised low temperature corrosion by inhibiting conversion of sulphur dioxide to sulphur
trioxide
• Reduced piston ring fouling resulting in longer life of piston rings and cylinder liner
• Reduced ash deposit formation in turbo-chargers and on exhaust valves
• Decreased smoke emissions
• Inhibited sludge formation in tanks, filter and pre-heater
• Improved water separation in settling tanks and separators

APPLICATION & USE


Product is a concentrated and specially formulated to treat heavy fuel oil in diesel engines and boilers.

DIRECTIONS FOR USE


Dosage point location varies depending on the engine / boiler fuel system layout. The most efficient
and economical method is obtained with a metering pump, dosing the additive into the suction side of
the booster pump (diesel engines) or into the burner feed line (for boilers).

Alternatively, the additive may be dosed directly to the day tank prior to refilling or directly to the
bunker tanks.

Dosage rates are dependant upon engine characteristics, operating conditions and the quality of fuel
oil.

A CCAI (Calculated Carbon Aromaticity Index) number exceeding 840 indicated a poor fuel oil quality
which justifies the use of a chemical fuel oil treatment to counteract the effects hereof.

Typical dosage rate varies between 1:1000, 1:6000 and 1:12000.

Contact Eazychem for recommendations of the dosage rate based on specific problems and
requirements onboard.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY FOT
Product Code: 1801 Product Group: Fuel Treatment
Packaging: 25L Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
eazy FOT fuel oil treatment is blend of solvents, emulsifying agents and detergents aimed at handling
the challenges of burning residual fuels.

Product is in a convenient liquid form and has many beneficial uses including but not limited to
preventing sludge formation, reduced cleaning cost, maximised bunker yield and is easily soluble in all
types of fuel.

APPLICATION & USE


Product is concentrated and formulated to treat heavy fuel oil in diesel engines and boilers by
emulsifying moisture present in fuel and dispersing excess sludge thereby homogenising the fuel for
complete combustion.

Product can also be used as an effective cleaner of baked on carbon and sludge deposits, varnishes
and wax residues present in residual fuel.

DIRECTIONS FOR USE


Dosage point location varies depending on the engine / boiler fuel system layout. The most efficient
and economical method is obtained with a metering pump, dosing the additive into the suction side of
the booster pump (diesel engines) or into the burner feed line (for boilers).

Alternatively, the additive may be dosed directly to the day tank prior to refilling or directly to the
bunker tanks.

Dosage rates are dependant upon engine characteristics, operating conditions and the quality of fuel
oil.

A CCAI (Calculated Carbon Aromaticity Index) number exceeding 840 indicated a poor fuel oil quality
which justifies the use of a chemical fuel oil treatment to counteract the effects hereof.

Typical dosage rate varies from 1:2000 to 1:8000 depending on fuel analysis results.

Contact Eazychem for recommendations of the dosage rate based on specific problems and
requirements onboard.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY MICROTREAT
Product Code: 1821 Product Group: Fuel Treatment
Packaging: 25L Issue/Date: 1.30 - 22/10/2007

PRODUCT DESCRIPTION
The Problem – Bugs in Fuel?
Light and medium grade fuels are particularly susceptible to microbiological growth as they provide a
source of food for bacteria. Additionally, the marine environment provides all the moisture necessary
to trigger growth through water contamination during storage or transportation, condensation due to
the natural warming and cooling of the tank or from leakage into the bunker tank.

Fuel contamination presents several problems for the operator. They include deposits, corrosion,
water emulsification and energy loss. Deposits can occur in tanks, fuels lines, filtration and
purification equipment, fuel heaters, and eventually all the way to the fuel injectors of the engine.

These deposits cause blockages and restrictions which affect the fuel handling and delivery system.
Corrosion caused by the presence of sulfate reducing bacteria can normally be found on tank bottoms.
Sulfate reducing bacteria produce hydrogen sulfide gas and acid conditions which severely corrode
metals in the fuel storage system.

The emulsification of water caused by bacteria and fungi is extremely troublesome. In the form of an
emulsion it cannot be removed by simple filtration or separating equipment and it can cause poor fuel
atomisation and contribute to the breakdown of lubricating oil films. It is therefore essential to
establish an effective program to control microbiological contamination.

The Solution – eazy MicroTreat


This product is a concentrated low toxicity micro biocide fuel treatment developed for use in fuel
storage systems or tanks for effective control of bacteria and fungi. It will kill a variety of different
microbiological contaminants.

APPLICATION & USE


Product is effective in water, oil and at the interface between oil and water. The micro organisms are
killed by exposure to the biocide and product can be used as a preventative measure or to give an
immediate effective cure for contaminated systems. Product prevents corrosion and blockages.

DIRECTIONS FOR USE


Sterilisation of Lube Oil Systems:
After severe contamination, all areas should be cleaned manually to remove sludge and silt. On large
engines cleaning with undiluted eazy Degreaser of the casing frame followed by opening and
thoroughly cleaning the sumps is strongly recommended. This should be followed by flushing the
entire lubricating oil system with flushing oil containing this product.

Sterilisation of Fuel Storage Tanks:


If bacteria are suspected, water drawn from the fuel storage tank bottoms should be tested and the
bacteria count established. If this is above 105 / ml, there is a good chance that colonisation has
taken place throughout the fuel. In which case this product should be dosed directly to the fuel tank
prior to bunkering ideally in tanks less than 25% of storage capacity to allow thorough dispersion.

In untreated tanks, a ‘kill dose’ of 1 litre per 2,000 litres of contaminated fuel will be required.

As part of an ongoing maintenance programme, use eazy AutoTreat to disperse any water present
in the tanks thus minimizing the potential for further contamination.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY SOOT REMOVER-L
Product Code: 1815 Product Group: Fuel Treatment
Packaging: 25L Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
eazy Soot Remover-L is a concentrated liquid formulated to prevent soot deposits in exhaust gas
boilers at low temperature and consequential corrosion both of which decrease the thermal efficiency
of the system.

Correct and regular use of the product can lower running costs associated with regular cleaning and
maintenance in untreated systems and eliminates the need to shutdown the boiler or plant during
dosing.

APPLICATION & USE


eazy Soot Remover-L is easily dosed into the system using a suitable injection unit which ejects a fine
powder towards the hottest part of the flame that vaporises on contact with the hot exhaust gas thus
dispersing product throughout the system.

Unlike powder based products which due to larger particle size and greater weight are more difficult
to inject efficiently, the liquid version is more efficient at treating the entire surface area. The
modified soot particles which are dry and non-adherent are friable and can therefore be removed far
more effectively by the soot blowers.

DIRECTIONS FOR USE


Dosage
Depending on the prevailing conditions at time of treating, 1-2 litres of product is required for every
1000m2 of heating surface area. This amount should be adjusted depending on the on economiser
specification and fuel consumption.

Frequency
Product should be injected once or twice daily before soot blowing.

Equipment Required
Injection Unit.

Location
For the majority of cases the injector is placed into the exhaust system immediately after the
turbocharger gas outlet.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY SOOT REMOVER-P
Product Code: 1811 Product Group: Fuel Treatment
Packaging: 25L Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
eazy Soot Remover-P is a powder based compound of mineral salts, carbon oxidation catalysts and
slag modifiers designed to prevent soot deposits in exhaust gas boilers at low temperature which
decrease thermal efficiency and increase the consequential cold end corrosion in the system.

Correct and regular use of the product can lower running costs associated with regular cleaning and
maintenance in untreated systems and eliminates the need to shutdown the boiler or plant during
dosing.

APPLICATION & USE


eazy Soot Remover-P is easily dosed into the system using a suitable injection unit which ejects a fine
powder towards the hottest part of the flame that vaporises on contact with the hot exhaust gas thus
dispersing product throughout the system.

The modified soot particles which are dry and non-adherent are friable and can therefore be removed
far more effectively by the soot blowers.

DIRECTIONS FOR USE


Dosage
Depending on the prevailing conditions at time of treating and the amount of fuel being burned an
average 1 to 2kg of product is required for every 25 tonnes of fuel being burned. This amount should
be adjusted depending on the on economiser specification and fuel consumption.

Frequency
Product should be injected once or twice daily immediately after soot blowing.

Equipment Required
Injection Unit.

Location
For the majority of cases the injector is placed into the exhaust system immediately after the
turbocharger gas outlet.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY ACC
Product Code: 2401 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.30 - 29/11/2007

PRODUCT DESCRIPTION
eazy ACC air cooler cleaner is a highly active combination of cleaning and corrosion inhibiting
compounds. When sprayed on soiled parts of an air cooler product penetrates and dissolves deposits
of oil and grease. These accumulations can then be removed using compressed air or rinsing with
fresh water.

The product has a low order of toxicity, contains no harmful chlorinated solvents and has a high flash
point.

APPLICATION & USE


Air coolers will, during normal operation, become fouled with oil, grease and other contaminants
present in the air in the engine room. These contaminates are deposited on the cooling surfaces as
the air from the turbochargers passes through the air cooler.

In-service cleaning of diesel engine air coolers can be achieved by injecting an emulsion of product
into the air cooler trunk followed by a clean water rinse. Major engine manufacturers approve this
method.

Product is highly effective in cleaning soiled parts of the air cooler. The parts should be immersed in
undiluted product. The cleaning action penetrates deposits, dissolving oil matter and hydrocarbon
materials and loosens insoluble solids, which can then be removed by rinsing in fresh water or with
the use of compressed air.

DIRECTIONS FOR USE


Product should be mixed in two parts of water to form an emulsion. When preparing, the correct order
is to add product to the water (not vice versa). The resulting emulsion is non-flammable, non-
explosive and has no flash point.

In-service Cleaning
The emulsion should be injected into the air cooler trunk over a period of 10 minutes. Fresh water
should then be injected to rinse off the emulsified deposits.

Soak Method
This requires the cooler to be removed from the engine and immersed in a bath or tank of cleaning
solution with agitation provide by a compressed air line. After 2 to 4 hours the cooler should be
removed and rinsed with fresh water or blown with compressed air.

Circulation Method
Certain coolers can be cleaned in-situ. This requires a circulation system to be connected and the
emulsion circulated through the cooler. After cleaning the cooler should be drained and flushed with
fresh water.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY AQUACLEAN
Product Code: 2001 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.60 – 02/11/2010

PRODUCT DESCRIPTION
eazy Aquaclean is a water based multipurpose cleaner containing an effective blend of active agents
suitable for a broad range of cleaning applications. It is non-flammable and may be used in ultrasonic
cleaning applications.

Product contains no petroleum solvents and is therefore safe to use on all alloys and metals including
aluminum. It is completely soluble in water and has a pleasant odour.

In accordance with MARPOL Annex II Regulation 13.5.2 and MEPC.1/Circ.590, Tank Cleaning Additives
Guidance Note and Reporting Form, eazy Aquaclean is approved as a cargo tank cleaning additive.

APPLICATION & USE


• Does not contain nonyl phenol ethoxylates
• Low order of toxicity
• IMO approved
• Non flammable
• Water based
• May be used as a traffic film remover

DIRECTIONS FOR USE


General Cleaning
Product should be applied as a 10 to 20% solution in water to soiled surfaces by brushing or spraying,
allowing at least 15 to 30 minutes for it to penetrate the soiled parts. The cleaning effect is maximized
when used with hot water. After cleaning items should be rinsed well with clean water.

Ultrasonic Cleaning
Product can also be used in a 25% solution of fresh water for use in all ultrasonic cleaning tanks. The
cleaning time will vary and will depend on the degree of soiled deposition. Heating the solution to 50
to 60°C will enhance the cleaning effect.

Tank Cleaning
After discharge of cargo, and depending on severity of deposition, a 2 to 10% solution with water
should be applied onto dry surfaces by low pressure spray. Allow product to penetrate for about ten
minutes (but do not allow to dry) before rinsing off with water using highest pressure available. If a
light powder dusting is still evident after drying we recommend a light rinse be applied using ½%
solution with water.

Cargo tank washing after cargo discharge using a mechanical recirculation process will require a
solution to be injected at a rate of 5 to 10 litres per tonne of water depending on severity of residue
to be removed.

A 1-2% solution with water can also be used for cleaning with high-pressure washing equipment.

Either fresh or seawater may be used in above cleaning methods. Some spot scrubbing may still be
required for stubborn stains.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY AQUACLEAN HD
Product Code: 2005 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.70 – 02/11/2010

PRODUCT DESCRIPTION
eazy Aquaclean HD is a multipurpose and concentrated heavy duty cleaner designed for use in
conditions requiring effective and economical removal of stubborn oily deposits. It is environmentally
sensitive, does not contain petroleum solvents and is suitable for hydrocarbon-free cleaning.

Product can be used for cleaning vegetable, animal and mineral oils after cargo discharges.

Product has been tested by Marinfloc and approval status is granted as “Can Be Separated”. Contact
technical@eazychem.co.uk or Marinfloc directly for specific details.

In accordance with MARPOL Annex II Regulation 13.5.2 and MEPC.1/Circ.590, Tank Cleaning Additives
Guidance Note and Reporting Form, eazy Aquaclean HD is approved as a cargo tank cleaning additive.

APPLICATION & USE


• Does not contain nonyl phenol ethoxylates
• Low order of toxicity
• Non flammable
• Water based
• May be used as a traffic film remover
• May be used in ultrasonic cleaning applications

DIRECTIONS FOR USE


General Cleaning
Product should be applied as a 5 to 10% solution in water to soiled surfaces by brushing or spraying,
allowing at least 15 to 30 minutes for it to penetrate the soiled parts. The cleaning effect is maximized
when used with hot water. After cleaning items should be rinsed well with water.

Ultrasonic Cleaning
Product can also be used in a 10 to 15% solution of fresh water for use in all ultrasonic cleaning
tanks. The cleaning time will vary and will depend on the degree of soiled deposition. Heating the
solution to 50 to 60°C will enhance the cleaning effect.

Tank Cleaning
After discharge of cargo, and depending on severity of deposition, a 2 to 10% solution with water
should be applied onto dry surfaces by low pressure spray. Allow product to penetrate for about ten
minutes (but do not allow to dry) before rinsing off with water using highest pressure available. If a
light powder dusting is still evident after drying we recommend a light rinse be applied using ½%
solution with water.

Cargo tank washing after cargo discharge using a mechanical recirculation process will require a
solution to be injected at a rate of 5 to 10 litres per tonne of water depending on severity of residue
to be removed.

A 1-2% solution with water can also be used for cleaning with high-pressure washing equipment.

Either fresh or seawater may be used in above cleaning methods. Some spot scrubbing may still be
required for stubborn stains.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY CITRACLEAN
Product Code: 2007 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.20 – 29/11/2007

PRODUCT DESCRIPTION
eazy Citraclean is a concentrated blend of surfactants, soil dispersants, sequestrants and naturally
derived citrus solvents, which gives the diluted product the capability to remove heavy soiling, which
would normally require a solvent type product.

It is suitable for range of dilutions to gives cost effective performance.

APPLICATION & USE


• Economical to use
• Easily and gently removes dirt and grime
• Safe on paintwork, metal surfaces, glass and rubber
• Universal application
• Effective in hard and soft waters
• Petroleum solvent free
• Non Caustic – neutral pH when diluted
• Pleasant citrus odour
• Biodegradable

DIRECTIONS FOR USE


General Cleaning
For accommodation areas, floors etc. use at up to 1:150 parts dilution in water depending on the
degree of dirt to be removed. Apply with brush, swab or spray and then rinse with clean water.

Heavy Duty Cleaning


Effective heavy duty degreasing can be achieved by applying the product neat or up to 1:50 parts
dilution in water to the areas to be cleaned. Apply to surface, work into dirt and allow a few minutes
contact time prior to rinsing with clean water.

A hot water bath (up to 60°C) will increase the efficiency of the product when cleaning heavily soiled
parts.

Graffiti Removal
May also be used neat on a cloth to remove felt tip pen, crayon etc.

Chain Degreasing
Dilute 1:1 with water or use neat with a cleaning machine.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY DEGREASER
Product Code: 2411 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.40 – 28/09/2010

PRODUCT DESCRIPTION
eazy Degreaser is a blend of emulsifying solvents and surfactants that can be used as an effective
cleaner for soiled surfaces, bilges, bulkheads, painted surfaces and machinery parts.

Product has been tested by Marinfloc and approval status is granted as “Can Be Separated”. Contact
technical@eazychem.co.uk or contact Marinfloc directly for specific details.

APPLICATION & USE


Product is applied neat by hand, brush or spray. The cleaning time should be 30 to 90 minutes before
washing off with hot or cold fresh water or seawater.

Product is also suitable for use in steam cleaning equipment.

DIRECTIONS FOR USE


Circulation Method
This method can be used to clean lube oil heat exchangers, oil pre-heaters and filters.

Spot Cleaning
Product should be sprayed neat onto dirty surfaces. Bulkheads can be washed down using high
pressure cleaning machines preferably using hot water at 60°C.

Soak Method
Dirty parts can be cleaned in a bath of neat product for at least 30 minutes and then rinsed with
plenty of fresh water.

Spray Method
Product should be sprayed neat onto dirty surfaces. The cleaning time should be 15 to 30 minutes and
then rinsed with plenty of fresh water after scrubbing if necessary.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY ELECTRIC
Product Code: 2421 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.30 - 29/11/2007

PRODUCT DESCRIPTION
eazy Electric is a solvent cleaner which is economical and can be used to clean and degrease almost
all electrical equipment and motor components.

Product is a highly effective concentrated solvent with a controlled evaporation rate and fast
penetrating action.

APPLICATION & USE


Product is applied neat by hand, brush or most effectively by spray. Once the deposition has been
removed any remaining solvent will evaporate slowly. This may be aided by using clean compressed
air of low pressure and high volume.

DIRECTIONS FOR USE


Product can be used in wipe or spray cleaning applications, and must be applied neat. Most oily
deposits will loosen and disperse after soaking for only a few minutes.

Product may also be used on heavily soiled parts by immersing them for up to two hours.

Once cleaning has been completed parts should be blown clean with compressed air.

CAUTIONARY NOTES
• Always maintain adequate ventilation when using this product and never use on running or
live equipment.
• When using a fine spray never use an open light source.
• It is possible that product may affect some types of rubber or plastic. Either remove these
parts from the component or test on small area first for suitability.
• After cleaning motors or generators insulation resistance to ground should be tested to check
that it is still within its specified limits.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY NEUTRALISE
Product Code: 2016 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.20 - 29/11/2007

PRODUCT DESCRIPTION
eazy Neutralise is a highly alkaline liquid designed to neutralise metal surfaces after acid based
cleaning.

APPLICATION & USE


Product may be used in the post acid cleaning of boilers, diesel engine cooling water systems, heat
exchangers, condensers, evaporators and calorifiers.

DIRECTIONS FOR USE


After the system is flushed from the acid cleaning solution (e.g. eazy Descaler Plus, eazy Descaler
or eazy SAFE Acid), fill the boiler with fresh water and add the required amount of product to obtain
a 1-2% concentration (exact amount depends on prevailing conditions).

Circulate for a minimum of two hours and flush.

Product will also neutralise any acid remaining in the equipment.

CAUTION: Do not use product in any systems containing non ferrous metals, stainless steel etc.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY OWS CLEANER
Product Code: 2441 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.40 – 28/09/2010

PRODUCT DESCRIPTION
eazy OWS Cleaner quick breaking degreaser is an emulsifying detergent for general engine room
degreasing and for use in conjunction with oily water separators.

It is a blend of surfactants and solvents with exceptional cleaning properties that breaks quickly
allowing oil to separate from water.

It will not harm the operation of oily water separators, reducing the potential for oil discharge which is
a requirement under the MARPOL regulations.

Product has been tested by Marinfloc and approval status is granted as “Can Be Separated”. Contact
technical@eazychem.co.uk or Marinfloc directly for specific details.

APPLICATION & USE


Product is easy to apply and can be used to clean machinery, floor plates, and bulkheads as well as
engine room bilges.

DIRECTIONS FOR USE


Product can be diluted with fresh or seawater. For general cleaning, dilute product in a 5 to 10%
solution of water depending upon the degree of cleaning required.

After allowing the solution to penetrate the soiled areas, rinse well with warm water.

The general recommendation by most separator manufactures is for degreasers to be diluted to a


0.1% solution prior to being passed through a separator. Advice on specific requirements should be
sought from the separator manufacturer.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY SAFE CR
Product Code: 2451 Product Group: Cleaning & Maintenance
Packaging: 25L Issue/Date: 1.30 - 29/11/2007

PRODUCT DESCRIPTION
eazy Safe CR is a powerful solvent that has been specifically designed to remove carbonized and
baked-on deposits typically found on engine parts, valves and burner tips as well as other
components fouled by carbon, varnishes or resins.

Product does not contain cresylic acid and the non-corrosive properties and high flash point make it
safe to use.

APPLICATION & USE


Product penetrates deposits such as oil, grease and varnish and dissolves them in a short period of
time. Insoluble materials such as carbon are sufficiently softened so that they can easily be removed
with a water rinse and light scrubbing.

DIRECTIONS FOR USE


A sufficient amount of product should be placed in a suitable container covering the parts to be
cleaned. Smaller parts can be placed in a wire basket.

The parts should be allowed to soak for at least 4 hours or until the deposits are sufficiently dissolved
or loosened. Agitation with compressed air will assist the cleaning process.

Parts should then be removed, rinsed with water and then dried with compressed air.

If the parts have carbonized deposits allow them to stand in the solution for 12 to 24 hours, heating
to 50 to 60°C until the deposits have loosened sufficiently.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY CEMENT REMOVER-C
Product Code: 2055 Product Group: Descaling
Packaging: 25L Issue/Date: 1.10 - 29/11/2007

PRODUCT DESCRIPTION
eazy Cement Remover-C is a highly active concentrated liquid based acid designed to effectively
remove cement and lime residues as well as lime bound soiling from steel superstructures and all acid
resistant surfaces.

The product contains an inhibitor to limit acid attack on metal surfaces.

APPLICATION & USE


Product can be used for removing cement and lime residues.

DIRECTIONS FOR USE


For moderate cleaning tasks a solution of 20% of product should be made up by adding product to
fresh water (not the reverse) in a plastic container and then applied by brush or spray taking into
consideration all the necessary health and safety precautions.

Once satisfactory results are achieved, rinse well with plenty of fresh water.

Repeat if necessary.

IMPORTANT NOTE!!!
All ventilation arrangements must be unobstructed throughout the entire cleaning process. As it is
extremely likely that potentially explosive gas will be produced, it is recommended that in enclosed
spaces that the atmosphere is tested for the presence of hydrogen at regular intervals.

Product must not be used on tin, aluminium, zinc or galvanised metal surfaces.

Contact Eazychem for further information and advice.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY DESCALER
Product Code: 2014 Product Group: Descaling
Packaging: 25L Issue/Date: 1.10 - 29/11/2007

PRODUCT DESCRIPTION
eazy Descaler is an aggressive liquid descaling acid. It is used for cleaning the surfaces of heat
exchangers and other areas where build up of calcium and magnesium salts (scale) occur and impair
the efficiency of heat exchangers.

The product contains an inhibitor to limit acid attack of the base metal after the cleaning program has
been completed.

APPLICATION & USE


Product can be used for general descaling of heat exchangers, boilers, evaporators, coolers and
condensers.

The degree and type of the deposits will determine the time required for the descaling programme In
general the scale will be removed in 4 to 12 hours.

DIRECTIONS FOR USE


For moderate cleaning tasks a solution of 10-20% of product should be made up by adding product to
fresh water (not the reverse) in a plastic container and then circulated through the equipment to be
cleaned.

The process should be repeated as many times as is required for heavily scaled surfaces up to a
maximum time of 24 hours.

After cleaning, the system must be completely emptied and then refilled with fresh water to purge it
of gas before opening the steam drum door. It is then recommended that a 1 to 2% solution of eazy
Neutralise be circulated for 2 to 4 hours to ensure that metal surfaces and any remaining acids are
neutralised or once an acceptable pH level is obtained.

IMPORTANT NOTE!!!
Prior to carrying out any cleaning programme, sacrificial anodes (if present) should be removed and
the system sufficiently vented to atmosphere at all times. All ventilation arrangements must be
unobstructed throughout the entire cleaning process. As it is extremely likely that potentially
explosive gas will be produced, it is recommended that boiler ventilation terminals are tested for the
presence of hydrogen.

Product must not be used on tin, aluminium, zinc or galvanised metal surfaces.

Contact Eazychem for further information and advice.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY DESCALER PLUS
Product Code: 2011 Product Group: Descaling
Packaging: 25L Issue/Date: 1.60 - 29/11/2007

PRODUCT DESCRIPTION
eazy Descaler Plus is a fast acting and effective liquid descaling acid. It is used for cleaning the
surfaces of heat exchangers and other areas where build up of calcium and magnesium salts (scale)
occur and impair the efficiency of heat exchangers.

The product contains an inhibitor to prevent attack of the base metal after the cleaning program has
been completed and a dye which visually indicates when the cleaning potential of the acid has been
neutralised.

An additional feature is that any rust present in the system will also be removed in the cleaning
process.

N.B. Product is non-hazardous and does not contain hydrochloric acid and is therefore safe for use
with stainless steel.

APPLICATION & USE


Product can be used for general descaling of heat exchangers, boilers, evaporators, coolers and
condensers.

The degree and type of the deposits will determine the time required for the descaling programme In
general the scale will be removed in 6 to 18 hours.

DIRECTIONS FOR USE


A solution of 10% of eazy Descaler Plus should be heated at 50 to 60°C and circulated through the
heat exchanger. The colour indicator will turn from red to orange when the acid has been neutralised.

In this case the process should be repeated as many times as is required for heavily scaled surfaces
up to a maximum time of 24 hours.

IMPORTANT NOTE!!!
Prior to carrying out any cleaning programme, sacrificial anodes (if present) should be removed and
the system sufficiently vented to atmosphere at all times. All ventilation arrangements must be
unobstructed throughout the entire cleaning process. As it is extremely likely that potentially
explosive gas will be produced, it is recommended that boiler ventilation terminals are tested for the
presence of hydrogen.

After cleaning, the system must be completely emptied and then refilled with fresh water to purge it
of gas before opening the steam drum door. It is then recommended that a 1 to 2% solution of eazy
Neutralise be circulated for 2 to 4 hours to ensure that metal surfaces and any remaining acids are
neutralised.

Contact Eazychem for further information and advice.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY DISCLEAN
Product Code: 2021 Product Group: Descaling
Packaging: 25L Issue/Date: 1.30 - 29/11/2007

PRODUCT DESCRIPTION
eazy Disclean is designed to remove carbonaceous and varnish deposits from lube and fuel oil
separator discs.

It is completely soluble in water, easy to mix, safe to use and does not attack stainless steel or
damage the separator discs.

APPLICATION & USE


Product should be used to clean separator discs from both lube and fuel oil separators.

DIRECTIONS FOR USE


Once removed from the separators, the disc stack should be immersed in dilute solution of eazy
Disclean.

The dilution rate will depend upon the severity of the deposition. A 20% by solution with fresh water
can be typically used. The cleaning solution can also be heated to 50 to 60°C for maximum cleaning
effect.

The cleaning period will vary depending on the degree of deposition but should be in the region of 1 to
4 hours.

After cleaning, parts should be rinsed thoroughly with fresh water to remove all traces of deposition
and product.

CAUTION: Only ferrous parts should be placed in the cleaning solution. Do not use eazy Disclean
with bronze, brass or other non-ferrous metals.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY RSR
Product Code: 2031 Product Group: Descaling
Packaging: 25L Issue/Date: 1.40 - 02/11/2009

PRODUCT DESCRIPTION
eazy RSR rust stain remover is a liquid blend of acids and emulsifiers for removing rust or rust stains
on all iron and steel surfaces. The product also passivates metal surfaces to help prevent flash
rusting and atmospheric corrosion.

In accordance with the requirements of Annex 12 of IMO MEPC.2/Circ.11 (17 Dec 2005), eazy RSR is
approved as a cleaning additive.

APPLICATION & USE


Product is recommended for cleaning all types of ferrous metals and for removing rust or rust stains
from paintwork.

Product is non-flammable and is completely soluble in water.

DIRECTIONS FOR USE


General Cleaning
To remove light rust, surfaces to be treated must be free from oil and grease. eazy Degreaser should
be used for this purpose.

Heavy rust deposits or flaking paint should be removed with a wire brush. A solution of product in 4
parts of water should be liberally applied and allowed to penetrate for 15 to 20 minutes. The treated
surface should then be flushed with plenty of fresh water to prevent the product from drying as this
may leave a powdered deposit on the metal surface.

Tank Cleaning
Product can also be used to remove lime scale deposits after a tank cleaning operation when cargo
residue slops are disposable at sea. After completion of the tank cleaning operation, inject 0.5L of
product per 100L of wash water directly into the automatic washing system for 20-30 minutes at a
temperature of 70-80°C.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY SAFE ACID
Product Code: 2013 Product Group: Descaling
Packaging: 25L Issue/Date: 1.10 - 29/11/2007

PRODUCT DESCRIPTION
eazy SAFE Acid is a fast acting and effective powder based descaling acid. It is used for cleaning the
surfaces of heat exchangers and other areas where build up of calcium and magnesium salts (scale)
occur and impair the efficiency of heat exchangers.

The product contains an inhibitor to prevent attack of the base metal after the cleaning program has
been completed.

APPLICATION & USE


Product can be used for general descaling of heat exchangers, boilers, evaporators, coolers and
condensers.

The degree and type of the deposits will determine the time required for the descaling programme In
general the scale will be removed in 6 to 18 hours.

DIRECTIONS FOR USE


A solution of 5-10% of product should (if possible) be heated at 50 to 60°C and circulated through the
heat exchanger.

In this case the process should be repeated as many times as is required for heavily scaled surfaces
up to a maximum time of 24 hours. If no heating is possible product may need substantially longer to
clean satisfactorily.

The acid solution strength can be further enhanced by adding 1 part sodium chloride (salt) to 20 parts
of product or alternatively dissolve the product in fresh sea water. Any enhanced cleaning solution
must NOT be used for cleaning diesel engine cooling water systems.

After cleaning, the system must be completely emptied and then refilled with fresh water to purge it
of gas before opening the steam drum door. It is then recommended that a 1 to 2% solution of eazy
Neutralise be circulated for 2 to 4 hours to ensure that metal surfaces and any remaining acids are
neutralised.

IMPORTANT NOTE!!!
Prior to carrying out any cleaning programme, sacrificial anodes (if present) should be removed and
the system sufficiently vented to atmosphere at all times. All ventilation arrangements must be
unobstructed throughout the entire cleaning process. As it is extremely likely that potentially
explosive gas will be produced, it is recommended that boiler ventilation terminals are tested for the
presence of hydrogen.

Product should not be used on tin, aluminium, zinc or galvanised metal surfaces.

Contact Eazychem for further information and advice.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY AQUALAC
Product Code: 2471 Product Group: Tank Cleaning
Packaging: 25L & 200L Issue/Date: 1.70 - 01/11/2011

PRODUCT DESCRIPTION
eazy AquaLAC is a heavy duty alkaline tank cleaner and degreaser suitable for cleaning cargo tanks
and holds after discharge of drying, semi-drying and non-drying natural oils and fats.

In accordance with MARPOL Annex II Regulation 13.5.2 and MEPC.1/Circ.590, Tank Cleaning Additives
Guidance Note and Reporting Form, eazy Tankwash is approved as a cargo tank cleaning additive.
This regulation applies regardless of whether a product is discharged to shore or sea. For discharge
to shore, Master is required to complete the cargo record book and identify any cleaning additives.

Product also approved as meeting resistance requirements for the Jotun Tankguard range of marine
coatings.

APPLICATION & USE


Suitable for removing deposits including but not limited to: animal oils, fish oils, vegetable oils,
waxes, greases, sludge, carbon deposits, inert gas soot (IGS) deposits as well as deodorising tanks
prior to loading foodstuffs in order to achieve a sufficient standard of cleanliness.

DIRECTIONS FOR USE


Boilers
When “boiling out”/commissioning of newly re-tubed boilers, pre-acid cleaning or if a boiler is
contaminated with oil a 5-10% solution should be circulated for a maximum of 24hrs at a temperature
of 70-80°C. After draining, rinsed well with plenty of clean fresh water.

Product may also be used for petcoke cleaning by spraying neat product onto the surface and soaking
for 15-20 minutes before rinsing with clean fresh water or for boiler furnace cleaning a 10-50%
solution (depending on severity) in fresh water at a temperature of at least 40°C.

Tanks
Pre-Wash
After cargo has been discharged, pre-wash with adequate clean fresh / seawater heated to 50-60°C.

For drying, semi drying and in order to prevent the evaporation and polymerisation of lighter oils, use
cold water.

General Cleaning
The recommended method is direct injection followed by recirculation using tank cleaning machines.

Other methods such as hand spraying are also feasible although not as efficient.

Product is used in a solution of clean fresh / seawater which is heated in accordance to the cargo
supplier’s guidelines. Typically for palm oil this is at 55-65°C, and in the case of cargo containing
stearic acid, 72-77°C.

NB. Certain types of oils require lower cleaning temperatures due to polymerisation issues. Consult
with the cargo supplier for guidance. Unsuccessful cleans are usually the result of using higher than
recommended temperatures which may “bake on” residues rather than remove them.

Typical Application & Dosage Rates using Fresh Water (Sea Water use 1.5x)
• Recirculation: 1-2%
• Direct Injection: 2-3%
• Handspray: 50% (drying/semi-drying oils, veg oils & 100% (fish oils, fatty acids/alcohols)
• Refrigerated Cargo: Remove animal or vegetable fat then spray a 5 to 10% solution in fresh
water and rinse off using hot water high pressure hose.

Post-Cleaning
If “white lime” deposits are noticed after cleaning, due to using sea water or left-over cargo residues,
inject a 0.5-1% solution of eazy RSR for 30 minutes before rinsing the tanks with plenty of clean fresh
water.

IMPORTANT!
Product is suitable for use on epoxy coatings and most common metals with exception to aluminium,
galvanised metal, tin, zinc and zinc silicate coating. In this case use our other IMO approved products
such as eazy NBD or eazy Aquaclean HD.
SUPERVISION
As well as a full range of globally available tank cleaning chemicals, we are also able to offer services
in upgrading vessels from “dirty” to “clean” cargoes. By attending a vessel during the discharge of its
oil, and then remaining with it through the subsequent cleaning operation, we ensure that it is in a
suitable condition to load the next cargo.

Our supervisors have been market leaders since 1981 in assisting clients to protect their financial
interests during clean up. Available at short notice to travel globally, a pool of personnel based in the
UK and USA include former Master Mariners with proven track records in tank cleaning.

By combining product and service our total package is not only competitive but offers excellent value
in providing a worry-free solution for the operator.

For more information, or to enquire about your chemical and/or service enquiry, please contact
sales@eazychem.co.uk

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY NBD
Product Code: 2475 Product Group: Tank Cleaning
Packaging: 25L Issue/Date: 1.50 - 02/11/2010

PRODUCT DESCRIPTION
eazy NBD is an effective non-caustic detergent designed for use in circumstances where caustic based
cleaners cannot be used.

It is safe to use on most metals including zinc, tin, aluminium and galvanised materials and zinc
silicate coated tanks.

In accordance with MARPOL Annex II Regulation 13.5.2 and MEPC.1/Circ.590, Tank Cleaning Additives
Guidance Note and Reporting Form, eazy NBD is approved as a cargo tank cleaning additive.

APPLICATION & USE


Product is suitable cleaning cargo tanks after discharge of drying, semi-drying and non-drying natural
oils and fats.

It can be used for tank cleaning and deodorising prior to changing to foodstuffs in order to achieve a
sufficient standard of cleanliness.

DIRECTIONS FOR USE


General Cleaning
Product should be applied undiluted for general maintenance applications such as deck areas and
bulkheads. Once applied, it should be allowed to soak for at least 15 to 20 minutes and agitated by
brushing, then rinsed thoroughly with water.

Tank Cleaning
For tank cleaning applications a pre-wash with hot water at a temperature of 60 to 70°C is
recommended. A solution rate of 2 to 5% should then be premixed in a holding tank and re-circulated
by automatic tank washing equipment for a period of 3 to 6 hours at 80°C

Product can also be used to degrease tanks by spray method. It should be applied undiluted and
allowed to soak for a period of at least 30 minutes and then rinsed with hot water at 60 to 70°C.

NOTE: Certain types of oils require lower cleaning temperatures due to polymerisation issues. Consult
with the cargo supplier for more information and guidance.

SUPERVISION
As well as a full range of globally available tank cleaning chemicals, we are also able to offer services
in upgrading vessels from “dirty” to “clean” cargoes. By attending a vessel during the discharge of its
oil, and then remaining with it through the subsequent cleaning operation, we ensure that it is in a
suitable condition to load the next cargo.

Our supervisors have been market leaders since 1981 in assisting clients to protect their financial
interests during clean up. Available at short notice to travel globally, a pool of personnel based in the
UK and USA include former Master Mariners with proven track records in tank cleaning.

By combining product and service our total package is not only competitive but offers excellent value
in providing a worry-free solution for the operator.

For more information, or to enquire about your chemical and/or service enquiry, please contact
sales@eazychem.co.uk

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY TANK DEODORISER
Product Code: 2481 Product Group: Tank Cleaning
Packaging: 1L, 5L, 20L, 25L Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
eazy Tank Deodoriser is a liquid based on perfumed oils in water.

It is suitable for eliminating unpleasant odours in tanks and domestic areas and is safe to use on most
common metals and coatings.

APPLICATION & USE


Product is used when malodour from previous cargo (e.g. fish oil) is distinguishable after tank
cleaning.

It is recommended that the source of the malodour is determined before applying the product. If bad
cleaning causes the smell, the tank should be cleaned again because application of the product into an
unclean tank may cause a surveyor to reject.

DIRECTIONS FOR USE


Product is sprayed in a 1:10 dilution with water.

Normally 1-2 litres of product is sufficient for one 400m³ tank.

Allow the product to evaporate for a reasonable period. It is also possible to dose 0.1 - 1% of the
product to the last rinsing water after cleaning the tank.

After treatment thoroughly ventilate the tank before entering.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY TANKWASH
Product Code: 2461 Product Group: Tank Cleaning
Packaging: 25L & 200L Issue/Date: 1.70 - 03/12/2010

PRODUCT DESCRIPTION
eazy Tankwash is a tank cleaner and degreaser for removing petroleum residues and mineral oils.

In accordance with MARPOL Annex II Regulation 13.5.2 and MEPC.1/Circ.590, Tank Cleaning Additives
Guidance Note and Reporting Form, eazy Tankwash is approved as a cargo tank cleaning additive.
This regulation applies regardless of whether a product is discharged to shore or sea. For discharge
to shore, Master is required to complete the cargo record book and identify any cleaning additives.

APPLICATION & USE


Suitable for use by direct injection, machine cleaning, spraying or the eazy Tankwash Method.

DIRECTIONS FOR USE


The following methods of cleaning are for guidance purposes only. They do not replace the
judgment of the crew or attending supervisor.

Pre-Wash
Prior to cleaning it is recommended to prewash the tanks with hot fresh / seawater at 50-60°C. For
crude oil, drying and semi-drying oils a pre-wash using cold water.

Direct Injection Method for Cargo Tanks


Product should be injected at the recommended rate of 1-2 litres per 1000 litres of wash water into
the pressure side of the automatic tank cleaning system by means of an air operated drum pump.

The cleaning process should take 3 to 6 hours after which rinse well with clean fresh / seawater.

Re-circulation Method
An adequate volume of solution to maintain recirculation of product and seawater is prepared in the
cargo or slop tank and circulated by the automatic tank washing system pump and heater to the tank
to be cleaned. The recommended concentration is 2 litres of product per 1000 litres of wash water.
Best results will be achieved by heating the solution to 60°C. The solution is then returned to the
mixing tank through the stripping line and the tank then rinsed with clean fresh / seawater.

NB. Depending on the size and condition of the tank, one solution is adequate for cleaning up to 3
tanks using this method, and any additional tanks should be cleaned with a new solution.

Hand Spraying Method


This method, whilst economical, is dependent upon the tanks being gas free to enable ship’s staff to
enter safely.

An air operated drum pump and hand spray equipment should be used. After spraying [neat] product
allow at least 30 minutes soak time. The tanks should then be rinsed with clean fresh / seawater.

eazy Tankwash Method


This method, used traditionally whilst the vessel is at sea, can also be used to clean and gas free
double bottom tanks.

1. The tanks should be heated by means of the steam coils to normal operating temperature
and then stripped of fuel. It may be necessary to trim the vessel to ensure as much fuel as
possible is removed.
2. All manifold valves should be closed and secured.
3. The first dose of product should be dosed (see dosage graph below) and the tank filled to
25% of its capacity with seawater.
4. The solution should be heated to 60°C and this condition should be maintained for 24 hours.
5. After cleaning strip the tanks and then refill to 75% capacity and add the second dosage of
product, continue heating and maintain for a further 72 hours.
6. Strip the contents of the tanks and pressure rinse with clean fresh / sea water through the
sounding pipes.

Gas Freeing
7. In order to gas free the tanks add seawater through the sounding vent or sounding pipes and
press up the tanks.
8. Stop water supply and completely strip the tanks, trimming vessel to ensure that all the
water has been removed.
DIRECTIONS FOR USE cont’d
Dosage Table

Dosage per 1000L of Wash Water

<180 centistokes >180 centistokes

Primary Clean 0.75 1


Secondary Clean n/a 1

SUPERVISION
As well as a full range of globally available tank cleaning chemicals, we are also able to offer services
in upgrading vessels from “dirty” to “clean” cargoes. By attending a vessel during the discharge of its
oil, and then remaining with it through the subsequent cleaning operation, we ensure that it is in a
suitable condition to load the next cargo.

Our supervisors have been market leaders since 1981 in assisting clients to protect their financial
interests during clean up. Available at short notice to travel globally, a pool of personnel based in the
UK and USA include former Master Mariners with proven track records in tank cleaning.

By combining product and service our total package is not only competitive but offers excellent value
in providing a worry-free solution for the operator.

For more information, or to enquire about your chemical and/or service enquiry, please contact
sales@eazychem.co.uk

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
CORROHIB 2K / 5K
Product Code: 2501 2505 Product Group: Anticorrosion
Packaging: On Request On Request Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
Corrohib 2K / 5K is 100% solids modified sulfonate corrosion preventative coating that cures to a soft
and flexible film.

Product is suitable as an effective barrier against corrosive environments in areas such as ballast
tanks and void spaces and has excellent penetration and curing performance.

The typical performance and service life for the product is up to 2 years for 2K and up to 5 years for
5K.

APPLICATION & USE


Product can be applied on deep-sea vessels ballast tanks and void spaces, dry-docks, barges, ferries,
offshore rigs and platforms.

DIRECTIONS FOR USE


Surface Preparation
The unique benefit of the product formulation is that it does not have to be applied to specifically
prepared surfaces. The tank surfaces can be prepared by cleaning with a high-pressure water wash.
Loose scale and mud accumulations should be removed from the tank before application.

Application
Eazychem recommends that the product is stored at temperatures between 1 to 32°C (5 to 90°F).

The product can be applied with a low-pressure airless spray unit and carried out at temperatures
between 5 to 35°C (41 to 95°F). Product should then be allowed at least 48 hours to cure with good
ventilation at all times.

Contact Eazychem for further information, suitability and surface preparation requirements.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY RUST PREVENTER
Product Code: 2511 Product Group: Anticorrosion
Packaging: 25L Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
eazy Rust Preventer is a solvent deposited, water displacing, light corrosion preventive that provides
medium to short-term protection on ferrous or aluminium alloy components, sheets and tubes and is
particularly suited for inter-shop protection after machining operations.

It is formulated using low odour solvents to improve operator acceptability and reduce environmental
impact.

APPLICATION & USE


• Excellent de-watering properties
• Light film - no need to clean before assembly
• Contains fingerprint suppressant
• Excellent de-emulsification
• Low odour
• High flashpoint (>70°C)
• Non volatile content of 16%
• Cost effective

DIRECTIONS FOR USE


Dip Tank
Using a wire basket, submerge components for at least 30 seconds. Lift from fluid, allow to drain and
stack to dry for at least 2 hours. Drain tank of excess water periodically.

Brush or Spray
Liberally apply to components and allow to dry for at least 2 hours.

Coverage
70m/litre at 2.2 microns (dipped)

Protection Period
Indoors: 9 months
Covered Outdoors: 3 months
Outdoors: Not recommended for outdoors use

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY VCI POWDER
Product Code: 2522 Product Group: Anticorrosion
Packaging: 25Kg Issue/Date: 1.10 - 22/10/2007

PRODUCT DESCRIPTION
eazy VCI Powder is a water-soluble vapour corrosion inhibitor (V.C.I.) powder with superior corrosion
inhibitor for wet or dry corrosion protection of ferrous metals and aluminium.

Product offers low dosage effectiveness as a treatment for closed loop cooling system,
hydrotesting and wide variety of marine process applications.

APPLICATION & USE


Product is used for:

• Wet protection of internal cavities and voids that can be covered or closed after application.
• Protection of closed loop cooling systems-dry lay-up.
• Protection of pipes and equipment during hydrostatic testing.
• Protection of tubular structures, pipes, heat exchangers, tanks, vessel etc.

Benefits include:

• Wet corrosion protection.


• Low dosage provides economical treatment.
• Water soluble for easy application.
• Provides effective corrosion protection against aggressive attack from chloride, saltwater and
other dissolved halogens.
• Biodegradable.
• Does not contain phosphates, chromates or other heavy metals.

DIRECTIONS FOR USE


Wet Application
Product should be added at 1.5% by weight of water for severe applications and 0.75% by weight of
water for less corrosive environment.

Dry Application
Applying powder by dusting, fogging or sprinkling. After application seal all vents.

Fogging can be achieved by using a low pressure air hose and sandblast cup.

For powder application, use 10 grams of product per cubic foot (28 litres) of enclosed space.

Can be easily removed by using a low pressure air gun or by a water rinse.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY OSE
Product Code: 2431 Product Group: Antipollution
Packaging: 25L Issue/Date: 1.30 - 29/11/2007

PRODUCT DESCRIPTION
eazy OSE is a low toxic biodegradable and environmentally acceptable oil spill dispersant with high
dispersing efficiency. It is specifically designed for oil pollution on water and is a concentrated blend of
solvents and dispersants offering a cost effective means of dispersing oil.

Product will convert hydrocarbons into fine emulsions.

APPLICATION & USE


Product can be used on a wide range of oils, converting the oil slick into small droplets which are
rapidly distributed within the sea as part of natural water movement.

DIRECTIONS FOR USE


Product should be used neat and applied directly on the affected area by spraying.

Spills on Water
After containing the contaminated area, product should be sprayed uniformly over the surface of the
floating oil (10 to 25% by volume) using a pressurized spray system. Allow product to soak for 15 to
20 minutes and then use water jets over the treated area to vigorously agitate and aid the dispersion
of oil.

Spills on Solid Surfaces


After removing as much oil as possible, spray product neat over the affected area and allow adequate
time for absorption. The mixture can then be dispersed by means of a fire hose.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY BIOKLEEN
Product Code: 1421 Product Group: Hygiene & Sanitation
Packaging: 12x1L Issue/Date: 1.20 - 29/11/2007

PRODUCT DESCRIPTION
eazy BioKleen is a specially selected blend of non toxic natural microbes combined with surfactants
and perfume to digest oils, greases and other organic matter which may block drainage systems. This
enables solids to be flushed away leaving them grease and odour free.

It is especially useful for use as a toilet cleaner for Evac type systems where it will descale and
sanitize effectively.

Ideal for use as part of a waste treatment strategy when used with other products such as eazy
BioMSC and eazy BioTreat.

APPLICATION & USE


Some of the benefits include:

• Forms long lasting bio-film


• Gives a renewable source of highly effective enzymes
• Mild descaler
• Removes the need for hazardous chemicals
• Effective in hard and soft waters
• Can be used on a variety of applications
• Cost effective
• Significantly reduces effluent B.O.D. and C.O.D.

DIRECTIONS FOR USE


Toilet / Washroom Cleaning
Apply an initial dose of 1 litre to the system followed by a maintenance dose of 150mls/day. The dose
should be introduced into the head of the drainage system or immediately before the main entry point
of the organic waste. Automatic dispensing should be timed for 1 hour during low use periods and
injected directly into the line.

CAUTION: Avoid the use of concentrated disinfectants, acid descalers and bleaches, which will affect
the bio-film and eliminate the naturally occurring enzymes.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY BIOMSC
Product Code: 1411 Product Group: Hygiene & Sanitation
Packaging: 12x1L Issue/Date: 1.40 - 29/11/2007

PRODUCT DESCRIPTION
eazy BioMSC is a specially selected blend of non toxic natural microbes combined with surfactants and
perfume formulated to prevent the build up of uric acid scale in vacuum toilet systems. It is used for
promoting the breakdown of greases, oils fats and organic waste in drains which may lead to
blockages if left untreated.
It may also be used as a general purpose floor and wall cleaner and is ideal for use in Evac systems.

APPLICATION & USE


• Forms long lasting bio-film
• Gives a renewable source of highly effective enzymes
• Mild descaler
• Removes the need for hazardous chemicals
• Effective in hard and soft waters
• Can be used on a variety of applications
• Cost effective
• Significantly reduces effluent B.O.D. and C.O.D.

DIRECTIONS FOR USE


Waste Pipe Cleaning & Uric Acid Prevention
For the effective prevention of uric acid build-up, dose 50mls of product directly to the drains on a
daily basis.

Toilet Bowl Cleaning


Product should be liberally applied to the toilet bowls and agitated by means of hand brushing and
flushing.

General Cleaning
For general cleaning such as floors, sinks and tiled areas use 100mls in 5 litres of warm water.

Odour Control
For odour control in urinals, sinks etc spray product neat or up to 2:1 dilution.

CAUTION: Bleaches and other acid or caustic based cleaners are not recommended to be used as
they will destroy the microbes that make product effective.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY BIOTREAT
Product Code: 1431 Product Group: Hygiene & Sanitation
Packaging: 4x5L Issue/Date: 1.20 - 29/11/2007

PRODUCT DESCRIPTION
eazy BioTreat is an economical to use organic waste treatment specifically designed to maintain the
efficiency of marine sanitation systems. The biologically active liquid promotes the degradation of fats,
greases and other organic materials as well as the odours they produce.

When it is dosed directly to the sewage treatment plant (or via the nearest toilet) the biological
activity will be enhanced keeping the plant at peak operating efficiency.

APPLICATION & USE


Some of the benefits include:

• Gives a renewable source of highly effective enzymes


• Removes the need for hazardous chemicals
• Effective in hard and soft waters
• Can be used on a variety of applications
• Cost effective
• Significantly reduces effluent B.O.D. and C.O.D.

DIRECTIONS FOR USE


Tank Treatment
Dosage levels are determined by the number of people onboard the vessel and the condition of the
sewage plant. If the system requires to be reactivated, dose 1 litre of product directly to the tank or
via the nearest toilet.

For a vessel with up to 50 people onboard, a maintenance dosage of 100mls per week of product
should be used.

For a passenger vessel, repeat above for each tank in use.

Line Cleaning
Organic matter can be gradually removed from waste lines by dosing a solution of 100mls of product
mixed with warm water on a nightly basis until the line runs free. If it is possible to isolate a section
of line then fill the line with above solution and leave for at least 24 hours.

Tank Cleaning
Product can also be used to periodically clean holding tanks. In order to provide a low volume
circulation holding tanks must be fitted with and air manifold to gently agitate the water. The tank
should be filled to 75% capacity with fresh or salt water and the air supply turned on.

When ready, add 2 litres of product to 2 litres of warm water and dose directly into the tank or via the
nearest toilet. An additional solution of 1 litre of product mixed with 1 litre of warm water per 1000
litres of capacity should be added. The tank should be filled and left for 48 hours with the air
circulating.

CAUTION: Avoid the use of concentrated disinfectants, acid descalers and bleaches, which will affect
the bio-film and eliminate the naturally occurring enzymes.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
SODIUM HYPOCHLORITE
Product Code: 1445 Product Group: Hygiene & Sanitation
Packaging: 25L Issue/Date: 1.10 - 29/11/2007

PRODUCT DESCRIPTION
Sodium hypochlorite is a liquid chlorine product designed to disinfect drinking water.

APPLICATION & USE


Shock chlorination of water systems and disinfection of drinking water.

DIRECTIONS FOR USE


The initial dose of chlorine injected into water is likely to be consumed in the oxidation of any iron,
manganese or hydrogen sulphide present in the water. Once the chlorine demand from these
processes has been satisfied, which typically takes 30 minutes, what remains is residual chlorine. e.g.
Chlorine Residual (0.5ppm) = Chlorine Dosing (2.0ppm) less Chlorine Demand (1.5ppm).

Dose product until a free available chlorine residual of at least 0.2ppm (and no more than 0.6ppm) is
attained throughout the distribution system. The exact amount required depends on the water
chemistry, temperature, contact time, and presence or absence of sediment.

When taking water in a port in a new country, and especially in tropical regions, the chlorine
requirement may be much higher in which case dosage will need to be increased in order to obtain
the desired Chlorine content at the tap.

Check water daily for the first 7 days on initial dosing, thereafter weekly with our Chlorine LR Test Kit
(Product Code 4070).

Dosing at 1 - 2ppm level will provide disinfection with the capability to eliminate bacteria and organic
matter in the water.

If charcoal filters are installed in the hydrophore outlet pipe (i.e. after the tank and before the
consumption taps), a higher level of chlorine can be injected into the tank as any chlorine present in
the output line will be removed by the charcoal filter prior to domestic use. The charcoal filter should
be fitted with a bypass, so that a certain controlled amount of chlorinated water can be allowed to
bypass the charcoal, in order to maintain a small amount of chlorine in the outlet supply water. This
protects the pipe work after the charcoal filter from developing colonies of bacteria.

Caution: High concentrations of Chlorine increase the corrosion potential of the water.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY BWT TEST KIT COMPLETE
Product Code: 4011 Product Group: Test Kits & Equipment
Packaging: Case Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The eazy BWT-1 Test Kit, packed in a custom moulded case, contains all the necessary reagents and
equipment to monitor the condition of water in low pressure boilers.

Tablet and drop count tests provide an extremely simple yet effective method of analysis for an
important range of water parameters. These tests are particularly useful for the routine logging and
control of boiler water and cooling water systems when used in conjunction with our water
treatments.

CONTENTS
1 x 4001 - Alkalinity (P) HR Reagent
1 x 4004 - Chloride HR Reagent
1 x 4009 - Sulphite Reagent
1 x 4007 - pH Test Strips 4.5 - 10 (100pcs)
1 x 4008 - pH Test Strips 7 - 14 (100pcs)
1 x Carry case with sample container, test tube, stirrer and measuring syringes.

For replacement reagents please refer to above product codes.

DIRECTIONS FOR USE


The tests are carried out by taking a measured volume of water and adding one tablet/drop at a time
until a prescribed colour change takes place. The result of the test is given by the number of
tablets/drops used in relation to the volume of water sample taken. A wide range of test
concentrations can be measured by varying the sample size taken of the test.

Refer to specific test instructions contained within the case.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
ALKALINITY-P TEST KIT
Product Code: 4001 Product Group: Test Kits & Equipment
Packaging: Box Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The Alkalinity Test Kit offers an extremely simple and inexpensive method for determining alkalinity
levels in low pressure boilers.

Tablet and drop count tests provide an extremely simple yet effective method of analysis for an
important range of water parameters.

These tests are particularly useful for the routine control and logging of boiler water and cooling water
systems when used in conjunction with our water treatments.

CONTENTS
4001 – Alkalinity (P) HR Reagent
Sample container and/or measuring syringe

DIRECTIONS FOR USE


The tests are carried out by taking a measured volume of water and adding one tablet / drop at a
time until a prescribed colour change takes place. The result of the test is given by the number of
tablets/drops used in relation to the volume of water sample taken. A wide range of test
concentrations can be measured by varying the sample size taken of the test.

Refer to specific test instructions contained within the kit.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
CHLORIDE HR TEST KIT
Product Code: 4004 Product Group: Test Kits & Equipment
Packaging: Box Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The Chloride Test Kit offers an extremely simple and inexpensive method of determining chloride
levels in boiler, cooling water and make up water.

Tablet and drop count tests provide an extremely simple yet effective method of analysis for an
important range of water parameters. These tests are particularly useful for the routine logging and
control of boiler water and cooling water systems when used in conjunction with our water
treatments.

CONTENTS
4004 – Chloride HR Reagent
Sample container and/or measuring syringe

DIRECTIONS FOR USE


The tests are carried out by taking a measured volume of water and adding one tablet / drop at a The
tests are carried out by taking a measured volume of water and adding one tablet/drop at a time until
a prescribed colour change takes place. The result of the test is given by the number of tablets/drops
used in relation to the volume of water sample taken. A wide range of test concentrations can be
measured by varying the sample size taken of the test.

Refer to specific test instructions contained within the kit.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
CHLORIDE LR TEST KIT
Product Code: 4003 Product Group: Test Kits & Equipment
Packaging: Box Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The Chloride Test Kit offers an extremely simple and inexpensive method of determining chloride
levels in boiler, cooling water and make up water.

Tablet and drop count tests provide an extremely simple yet effective method of analysis for an
important range of water parameters. These tests are particularly useful for the routine logging and
control of boiler water and cooling water systems when used in conjunction with our water
treatments.

CONTENTS
4003 – Chloride LR Reagent
Sample container and/or measuring syringe

DIRECTIONS FOR USE


The tests are carried out by taking a measured volume of water and adding one tablet / drop at a The
tests are carried out by taking a measured volume of water and adding one tablet/drop at a time until
a prescribed colour change takes place. The result of the test is given by the number of tablets/drops
used in relation to the volume of water sample taken. A wide range of test concentrations can be
measured by varying the sample size taken of the test.

Refer to specific test instructions contained within the kit.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
EAZY CWT TEST KIT COMPLETE
Product Code: 4021 Product Group: Test Kits & Equipment
Packaging: Case Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The eazy CWT Test Kit, packed in a custom moulded case, contains all the necessary reagents and
equipment to monitor the condition of engine cooling water.

Tablet and drop count tests provide an extremely simple yet effective method of analysis for an
important range of water parameters. These tests are particularly useful for the routine logging and
control of boiler water and cooling water systems when used in conjunction with our water
treatments.

CONTENTS
1 x 4003 - Chloride LR Reagent
1 x 4005 - Nitrite Reagent
1 x 4007 - pH Test Strips 4.5 - 10 (100pcs)
1 x Carry case with sample container, test tube, stirrer and measuring syringes.

For replacement reagents please refer to above product codes.

DIRECTIONS FOR USE


The tests are carried out by taking a measured volume of water and adding one tablet/drop at a time
until a prescribed colour change takes place. The result of the test is given by the number of
tablets/drops used in relation to the volume of water sample taken. A wide range of test
concentrations can be measured by varying the sample size taken of the test.

Refer to specific test instructions contained within the case.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
NITRITE TEST KIT
Product Code: 4005 Product Group: Test Kits & Equipment
Packaging: Box Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The Nitrite Test Kit offers an extremely simple and inexpensive method for determining nitrite levels
in cooling water systems.

Tablet and drop count tests provide an extremely simple yet effective method of analysis for an
important range of water parameters. These tests are particularly useful for the routine control of
boiler water and cooling water systems when used in conjunction with our water treatments.

CONTENTS
4005 – Nitrite Reagent
Sample container and/or measuring syringe

DIRECTIONS FOR USE


The tests are carried out by taking a measured volume of water and adding one tablet/drop at a time
until a prescribed colour change takes place. The result of the test is given by the number of
tablets/drops used in relation to the volume of water sample taken. A wide range of test
concentrations can be measured by varying the sample size taken of the test.

Refer to specific test instructions contained within the kit.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
SULPHITE TEST KIT
Product Code: 4009 Product Group: Test Kits & Equipment
Packaging: Box Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The Sulphite Test Kit offers an extremely simple and inexpensive method of determining sulphite
levels in low pressure boilers.

Tablet and drop count tests provide an extremely simple yet effective method of analysis for an
important range of water parameters. These tests are particularly useful for the routine logging and
control of boiler water and cooling water systems when used in conjunction with our water
treatments.

CONTENTS
4009 – Sulphite Reagent
Sample container and/or measuring syringe

DIRECTIONS FOR USE


The tests are carried out by taking a measured volume of water and adding one tablet/drop at a time
until a prescribed colour change takes place. The result of the test is given by the number of
tablets/drops used in relation to the volume of water sample taken. A wide range of test
concentrations can be measured by varying the sample size taken of the test.

Refer to specific test instructions contained within the kit.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
PH TEST STRIPS 4.5 - 10
Product Code: 4007 Product Group: Test Kits & Equipment
Packaging: Box Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The PH Test Kit offers an extremely simple and inexpensive method for determining PH levels in boiler
and cooling water systems.

PH test strips provide an extremely simple yet effective method of analysis for an important range of
water parameters. These tests are particularly useful for the routine control of boiler water and
cooling water systems when used in conjunction with our water treatments.

CONTENTS
4007 – PH Test Strips 4.5 – 10 (100pcs)
Colour Chart

DIRECTIONS FOR USE


The tests are carried out by taking a small volume of water and dipping the test strip until a
prescribed colour change takes place. The comparison of colour with the colour chart provided
indicates the PH level in the water.

Refer to specific test instructions contained within the kit.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
PH TEST STRIPS 7 - 14
Product Code: 4008 Product Group: Test Kits & Equipment
Packaging: Box Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The PH Test Kit offers an extremely simple and inexpensive method for determining PH levels in boiler
and cooling water systems.

PH test strips provide an extremely simple yet effective method of analysis for an important range of
water parameters. These tests are particularly useful for the routine control of boiler water and
cooling water systems when used in conjunction with our water treatments.

CONTENTS
4008 – PH Test Strips 7 - 14 (100pcs)
Colour Chart

DIRECTIONS FOR USE


The tests are carried out by taking a small volume of water and dipping the test strip until a
prescribed colour change takes place. The comparison of colour with the colour chart provided
indicates the PH level in the water.

Refer to specific test instructions contained within the kit.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
CHLORINE LR TEST KIT
Product Code: 4070 Product Group: Test Kits & Equipment
Packaging: Box Issue/Date: 1.10 - 22/10/2007

PRODUCT DESCRIPTION
The Chlorine LR Test Kit offers an extremely simple and inexpensive method for determining Chlorine
levels in potable water systems.

CONTENTS
Chlorine LR (F&T) 0-3.5/0-1.17 ppm Cl2 x 2 pots
Comparator Disc

DIRECTIONS FOR USE


Refer to specific test instructions contained within the kit.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
FOAM CONCENTRATE TEST KIT
Product Code: 4115 Product Group: Test Kits & Equipment
Packaging: Case Issue/Date: 1.10 - 22/10/2007

PRODUCT DESCRIPTION

Enables foam
concentrates to be
checked for physical
conformance and for
foam induction systems
to be easily calibrated.

Suitable for the


determination of:

• SG
• 1/4 drainage
• Expansion ratio
• Induction %

Suitable for use with


AFFF, Protein and AR
Foams (not suitable for
testing SG of AR foams)

CONTENTS
250 ml Beaker Hydrometer 1.000 − 1.050
Conical Measure Hydrometer 1.050 − 1.100
3 × Sample Bottles Hydrometer 1.100 − 1.150
Refractometer Hydrometer 1.150 − 1.200
500 ml Beaker Thermometer
1 ml Syringe 3 × 100 ml Cylinders
Mechanical Scales Collection Cylinder
Masses for Scales Foam Testing Manual
Stopwatch Carrying Case

Physical Overall Dimensions: − 57.5 cm × 52.0 cm × 34.0 cm


Gross Weight: − 18 kg
Construction: − Packed in robust offshore suitable case.

DIRECTIONS FOR USE


Suitable for testing to the following International Produced Foam Test Standards:

- NFPA 11 2002 (paragraphs 10.6.2 and 3)


- BS 5306

Each kit contains a step by step manual together with worked examples.

For those with access to a laboratory the manual includes “how to” descriptions for tests using a pH
Meter, Surface Tension Balance and Viscometer.

NB. IF TESTING THE PREMIX (PRODUCED FOAM) A FOAM EXPANSION STAND AND FOAM
COLLECTION BOARD (SUCH AS PRODUCT CODE 4119) SHOULD BE USED.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
PRODUCT DATA SHEET
PRODUCED FOAM TEST KIT
Product Code: 4117 Product Group: Test Kits & Equipment
Packaging: Case Issue/Date: 1.10 - 22/10/2007

PRODUCT DESCRIPTION

This Produced Foam Test Kit enables foam


induction systems to be easily calibrated.

Each kit contains a step by step manual


together with worked examples.

Suitable for testing to the following


International Produced Foam Test
Standards:

- NFPA 11 2002 (paragraphs 10.6.2 and 3)


- BS 5306

Suitable for use with AFFF, Protein and AR


Foams.

CONTENTS
250 ml Beaker 3 × 100 ml Cylinders
3 × Sample Bottles Foam Testing Manual
Digital Refractometer Carrying Case
1 ml Syringe

Physical Overall Dimensions: − 42.0 cm × 32.0 cm × 19.0 cm


Gross Weight: − 7 kg
Construction: − Packed in robust offshore suitable case.

DIRECTIONS FOR USE


Each kit contains a step by step manual together with worked examples.

NB. IF TESTING THE PREMIX (PRODUCED FOAM) A FOAM EXPANSION STAND AND FOAM
COLLECTION BOARD (SUCH AS PRODUCT CODE 4119) SHOULD BE USED.

HEALTH & SAFETY


Please refer to the Material Safety Data Sheet and Product Label for specific information.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
PRODUCED FOAM EQUIPMENT
Product Code: 4119 Product Group: Test Kits & Equipment
Issue/Date: 1.10 - 22/10/2007

FOAM COLLECTION BOARD

The Foam Collection Board is required for


enabling produced foam samples to be taken
correctly for use in calculating:

• 25% Drainage Test


• Foam expansion

FOAM EXPANSION BOARD

The Foam Expansion Board is required for


enabling produced foam samples to be taken
correctly, for use in calculating:

• 25% Drainage Test


• Foam Expansion
• Holds collection pots, as included in
Foam Concentrate Kits
• Constructed from painted stainless
steel

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
DRIP SAMPLER
Product Code: 1861 Product Group: Engineering
Packaging: Case Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The Drip Sampler is a precision built device which allows
the crew to easily take fuel samples in a safe and efficient
manner.

The new IMO regulation and MEPC.96(47) Marpol Annex VI


requirements, enforced from 19 May 2005, demands that
all ship operators comply in strict accordance concerning
engine emissions that include collection, retention and
storage of bunker fuel oil samples. For full compliance to
this regulation we recommend the Fuel Sample
Retention System.
For physical long term storage of fuel oil samples we recommend our specially designed Fuel Sample
Storage Cabinets.

FEATURES BENEFITS
• Material: Chrome-Nickel Steel (1Cr18Ni9Ti) • Unattended operation
• Size range: 4-10” • Provides representative samples
• Sample tank: 5Ltrs • Simple to install between manifold and
• Weight: Approximately 10Kgs bunker hose

DIRECTIONS FOR USE


Flange types available: DIN (size) PN 10, ASA (size) 150lbs, JIS (size) 5K, JIS (size) 10K.
If specification is not known please provide as much information as possible e.g. pipe inner diameter,
pipe thickness, flange outer diameter, pitch circle diameter (PDC), number of holes and hole
diameter.

HEALTH & SAFETY


No Material Safety Data Sheet available for this product.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
FUEL SAMPLE RETENTION SYSTEM
Product Code: 1862 Product Group: Engineering
Packaging: Case Issue/Date: 1.20 - 22/10/2007

PRODUCT DESCRIPTION
The Sample Retention System is a professionally built
package designed to comply with the latest Marpol Annex
VI requirements enforced from 19 May 2005. It allows the
crew to easily follow the regulations in a safe and efficient
manner.

The new IMO regulation and MEPC.96(47) guideline


requires all ship operators to comply in strict accordance
concerning engine emissions that include collection,
retention and storage of bunker fuel oil samples.

For physical storage of the fuel oil samples we recommend


our custom designed Fuel Sample Storage Cabinets.

As a feature the MT-SRS cubitainer and sampler are each


fitted with sealing provision to prevent tampering during
sampling thus complying with 5.2.5 and 5.3 of
MEPC.96(47). This method does NOT restrict the manual
valve operation as with most other designs on the market.
This ensures the bunkering period enabling adjustment to
control and flow to the primary sample as required (see
5.2.4 of MEPC.96(47).

FEATURES BENEFITS
• Complies to Marpol 73/78 Annex VI • Includes sampler
• Secure storage for all items • Wide-neck sample bottles for easy handling
• Compact and space efficient • Unique sealing for every bottle and cubitainer
• Weighs 37Kgs (1.00 x 0.56 x 0.40m) • Equipped with leak protection, tools and
cleaning materials

CONTENTS
1 x Strong secure lockable storage chest 1 x Pouring tap and handling box for cubitainer
1 x Fuel oil drip sampler (DIN, ASA, JIS 5k/10K) 2 x Pairs oil resistant gloves
2 x Spanner to mount drip sampler 1 x Safety glasses
20 x One litre wide neck sample bottles complete 5 x Oil absorbing mats
with unique numbered sealings and labels 1 x Ring binder with instructions and log book for
5 x Cubitainers complete with unique sealings delivery notes

DIRECTIONS FOR USE


For price and availability please contact sales@eazychem.co.uk giving flange type e.g. DIN (size) PN
10, ASA (size) 150lbs, JIS (size) 5K, JIS (size) 10K.

If this is unknown please provide as much information as possible e.g. pipe inner diameter, pipe
thickness, flange outer diameter, pitch circle diameter (PDC), number of holes and hole diameter.

HEALTH & SAFETY


No Material Safety Data Sheet available for this product.

LIMITATION OF LIABILITY
IMPORTANT: Eazychem’s standard terms and conditions of sale apply and contain limitations on any liability that
may be incurred by Eazychem arising in any way from the sale and use of any Eazychem products. In particular
please note that Eazychem’s terms and conditions state the following:

Except in respect of death or personal injury caused by Eazychem’s negligence, or liability for defective products
under the Consumer Protection Act 1987, Eazychem shall not be liable to the Buyer by reason of any representation
(unless fraudulent), or any implied warranty, condition or other term, or any duty at common law, or under the
express terms of the Contract, for loss of profit or for any indirect, special or consequential loss or damage, costs,
expenses or other claims for compensation whatsoever (whether caused by the negligence of Eazychem, its
employees or agents or otherwise) which arise out of or in connection with the supply of the Products (including any
delay in supplying or any failure to supply the Products in accordance with the Contract or at all) or their use or
resale by the Buyer, and the entire liability of Eazychem under or in connection with the Contract shall not exceed
the price of the Products, except as expressly provided in these Terms.
PRODUCT DATA SHEET
FUEL SAMPLE / HAZARDOUS STORAGE CABINET
Product Code: 7200 Small Product Group: Engineering
Product Code: 7201 Medium
Product Code: 7202 Large Issue/Date: 1.30 - 24/08/2012

PRODUCT DESCRIPTION

Bunker collection, sampling and storage guidelines have been defined by Marpol Annex VI which came
into force 19 May 2005.

The IMO regulation and MEPC.96(47) states that a retained sample of all fuel oils, as supplied, is
drawn at the ships receiving manifold, sealed, signed on behalf of the supplier and the Master or
ship’s officer in charge of the bunkering operation and that the retained sample is kept under the
ship’s control until the subject fuel has been substantially consumed, but in any case for at least 12
months from the date of delivery.

The Fuel Sample / Hazardous Storage Cabinet, as supplied by Eazychem, is a robust welded
construction unit manufactured using high quality steel of 0.7mm – 1.5mm for extra rigidity and to
maintain its structural integrity under extreme conditions. This unique design comes with a welded
leak proof base sump, a tough epoxy polyester coated finish, reinforced doors with steel door
stiffeners and a chrome 3 point locking handle. It is ideal for the secure storage of chemicals, paints
and hazardous substances in addition to fuel samples.

Optional extras include additional shelves to those included, stand with adjustable feet and a sloping
top to prevent items inappropriately being placed on top of the cabinet.

Cabinets conform to health and safety executive guide HSG51 and DSEAR 2002.

SPECIFICATION Small Medium Large


Size (mm) 910 x 457 x 457 1000 x 915 x 457 1830 x 915 x 457
Sump capacity (litres) 15 30 36
No. of shelves 1 1 3
Extra shelf option N/A Yes Yes
Stand w/adj. feet (mm) 533 x 457 x 457 533 x 915 x 457 533 x 915 x 457
Sloping top option (mm) N/A 150 x 915 x 457 150 x 915 x 457