DC Power System
Product Description
Version: V4.0R02M01
ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright © 2012 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.
Revision History
II
Intended Audience
This manual is intended for:
l Planning engineer
l Maintenance engineer
Chapter/Appendix Summary
Chapter 1, System Overview Introduces the system, the implementation example and
describes the system features.
Chapter 2, System Structure Describes the overall structure, power distribution parts,
temperature-controlling components, signal interface board,
slots configuration, requirements for embedded equipments
and dimensions.
Chapter 3, System Modules Describes the ZXD1500 rectifier and the monitoring unit.
Chapter 4, System Specifications Provides the technical specifications and compliant standards
of the system.
Appendix A, Electrical Connection Provides the electrical connection diagram of the system.
Diagram
Conventions
This document uses the following typographical conventions.
Typeface Meaning
Bold Menus, menu options, function names, input fields, option button names, check
boxes, drop-down lists, dialog box names, window names, parameters and
commands.
Warning: Indicates a hazard that, if not avoided, could result in serious injuries,
equipment damages or interruptions of major services.
II
l A wide range of input phase voltage (80 VAC - 300 VAC) makes the system suitable
for areas with unstable voltage.
1-1
l Integrating the power distribution, rectifiers, monitoring unit and batteries in a single
cabinet, and saving installation space.
l Hot-pluggable rectifiers, and convenient for installation and maintenance.
l Intelligent monitoring unit.
l With fans for heat dissipation.
l High reliability with MTBF ≥ 2.2 × 105 h.
l The ZXDU58 W121 system supports multiple networking modes, such as RS232,
RS485 and IP/SNMP (optional).
1-2
2-1
Part Description
Fan box For air ventilation of the equipment cabinet by the fans
Power equipment unit Integrated with the rectifiers, the monitoring unit and power distribution
unit
Power distribution part Provides electrical distribution through AC and DC branches and
connection terminals (refer to “Power Distribution Part” section of this
manual)
Monitoring unit Provides management of the power distribution parts (AC and DC),
rectifiers and batteries
2-2
and Figure 2-4 shows the terminal connection. Note that the AC input maybe configured
for either three-phase or single-phase system by modifying the AC input breaker. Refer to
Table 2-2 for the descriptions of the parts.
Part Description
2-3
Part Description
2-4
1. Voltage transmission board 3. Modem power board (MPB) 5. SNMP network interface
(TRB) 4. IP network interface board board (SNMP)
2. Fan control board (FCTL) (IP) 6. Signal interface board (SIB)
Board Function
Voltage transmission board (TRB) Provides AC voltage sampling signals for the monitoring unit.
Fan control board (FCTL) Controls the internal and external heat circulation fans of the
equipment cabinet.
Modem power board (MPB) Optional, used to provide 12 VDC power for the IP or SNMP
board.
2-5
Board Function
Signal interface board (SIB) Provides various signal interfaces, including battery
temperature detection interfaces, environment detection
interfaces and communication interfaces.
2-6
Note:
The IP board is an optional component that is installed according to the user requirement.
Interfaces
For the IP board interfaces, see Figure 2-9.
2-7
2 +12V
DIP Switches
For a description of the IP board Dual In-line Package (DIP) switches, refer to Table 2-6.
DIP Description
Switch
S2 1. S2[1,2,3] is used to set the baud rate for communication between the IP board and
the CSU, as shown in Table 2-7.
2. The S2[4] switch is used to set the communication mode between the IP board and the
CSU: RS485 or RS232.
l ON: RS485 communication mode.
l OFF: RS232 communication mode.
S3 Used to set working mode of the RS232 port, as shown in Table 2-8.
2-8
l The baud rate of two communication terminals should be consistent, otherwise the
communication will fail.
l The maximum baud rate supported by the CSU is 9600 bps.
ON ON OFF OFF When the RS232 interface and the SIB board are
interconnected, used in IP board in normal communication
working mode, making the communication between the IP
board and the SIB board more reliable.
2-9
Interface Description
For a description of the interfaces on the SNMP board, refer to Table 2-9.
Designation Description
RS232/RS485 RS232 and RS485 interface, to receive data from equipment at user end (It is a
Semi-duplex interface)
Indicator Description
For a description of the indicators on SNMP board, refer to Table 2-10.
Designation Description
TXD Not lit The ZXDU58 W121 system does not transmit data
2-10
2.7 Dimensions
The dimensions of the ZXDU58 W121 cabinet are shown in Figure 2-13.
• Unit: mm
The available battery installation space of each rack is shown in Table 2-11.
2-11
Item Dimension
2-12
For the appearance and structure of the ZXD1500 rectifier, see Figure 3-1.
3-1
CL Lit (yellow) Output current of the rectifier has reached its limit.
(Current limit)
Note:
When the rectifier is in sleep mode, only the IN indicator is lit.
Item Specifications
3-2
3-3
Item Specifications
Precision of the battery current and the output current of the system ±1%
Precision of the battery voltage and the output voltage of the system ±0.5%
l Collects the operational data and monitors the operation of the system.
l Provides alarm and necessary protection if the system is operating abnormally.
l Sends data to the background Supervision Center (SC) and receives the commands
from the SC. In this way, the system can be monitored remotely.
For details about using the CSU, refer to the ZXDU B121-CSU (SV2.20) Centralized
Supervision Unit Operation Guide.
3-4
Item Specification
Item Specification
4-1
Item Specification
Item Specification
Item Specification
4-2
Item Specification
Noise ≤ 55 dB(A)
Safety Standards
The ZXDU58 W121 system is in compliance with the UL/IEC/EN 60950 safety standards.
Other Standards
The ZXDU58 W121 system is also in compliance with the following standards:
l The Restriction of Hazardous Substances (RoHS) directive (2002/95/EC) of the
European Union.
l This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operations.
4-3
4-4
A-1
A-2
A-3
A-4
Manual Suite
Refer to the table below for the manual suite of the ZXDU58 W121 system.
DC Power System Safety Information This manual describes the personal health & safety
information and the system security information that you
should learn when working with the ZTE system products.
Intended Audience: This manual is intended for device
installation engineers, commissioning engineers and
maintenance engineers.
B-1
The following sections provide information on how to obtain support for the documentation.
For further questions, comments, or suggestions on the documentation, you can fax your
comments and suggestions to (86) 755 26770801. You can also browse our website at htt
p://ensupport.zte.com.cn, which contains various interesting subjects like documentation,
knowledge base, forum and service request.
B-2
MTBF
- Mean Time Between Failures
- 平均故障间隔时间
PC
- Personal Computer
- 个人电脑
RoHS
- Restriction of Hazardous Substances
- 有害物质限制
SIB
- Signal Interface Board
- 信号接口板
SNMP
- Simple Network Management Protocol
- 简单网络管理协议
SPD
- Surge Protection Device
- 电涌保护装置